Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Acta Med Okayama ; 78(1): 71-78, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38419317

RESUMO

We retrospectively investigated the mid-term outcomes of arthroplasty using the AVANTA silicone implant for thumb metacarpophalangeal (MCP) joints with boutonniere deformity in patients with rheumatoid arthritis (RA). This study involved 36 thumbs of 33 RA patients with a mean follow-up period of 5.1 years (range, 2.0-13.3). Postoperatively, the mean extension was significantly increased and the mean flexion was significantly decreased (p<0.001, p<0.001, respectively), resulting in the mean arc of range of motion (ROM) shifting in the direction of extension after surgery. Implant fracture was observed in 10 thumbs (28%), and 4 of these (11%) underwent revision surgery. The survivorship with implant fracture and revision surgery as endpoints were 73.4% and 91.8% at 5 years, respectively. The preoperative arc of ROM and the postoperative flexion range of the implant-fracture group were significantly greater than those in the no-implant-fracture group (p=0.039, 0.034, respectively). These results suggest the importance of patient education and careful rehabilitation to prevent excessive flexion. Overall, the AVANTA silicone implant showed a relatively high rate of implant fracture at our institute.


Assuntos
Artrite Reumatoide , Deformidades Adquiridas da Mão , Prótese Articular , Humanos , Polegar/cirurgia , Prótese Articular/efeitos adversos , Estudos Retrospectivos , Articulação Metacarpofalângica/cirurgia , Artrite Reumatoide/complicações , Artrite Reumatoide/cirurgia , Artroplastia , Deformidades Adquiridas da Mão/cirurgia , Amplitude de Movimento Articular , Silicones
2.
Acta Med Okayama ; 71(1): 41-47, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28238009

RESUMO

We investigated the long-term clinical results of total elbow arthroplasty (TEA) by cementless fixation of alumina ceramic unlinked elbow prostheses (J-alumina ceramic elbows: JACE) for the reconstruction of elbow joints with rheumatoid arthritis (RA). Seventeen elbows in 17 patients (aged 44-72 years, average 54.8) replaced by JACE TEA without bone cement were investigated. The average follow-up period was 10.7 (range, 1.0-19.3) years. Clinical conditions of each elbow before and after surgery were assessed according to the Mayo Elbow Performance Index (MEPI). Radiographic loosening was defined as a progressive radiolucent line of more than 1 mm that was completely circumferential around the intramedullary stem. The average MEPI significantly improved from 46.8 points preoperatively to 66.8 points at final follow-up (p=0.0226). However, aseptic loosening was noted in 10 of 17 elbows (58.8%) and revision surgery was required in 7 (41.2%). Most loosening was observed on the humeral side. With radiographic loosening and revision surgery defined as the end points, the likelihoods of prosthesis survival were 41.2% and 51.8%, respectively, up to 15 years by Kaplan-Meier analysis. The clinical results of JACE implantation without bone cement were disappointing, with high revision and loosening rates of the humeral component.


Assuntos
Óxido de Alumínio/uso terapêutico , Artrite Reumatoide/cirurgia , Artroplastia de Substituição do Cotovelo/métodos , Cimentação/métodos , Articulação do Cotovelo/cirurgia , Adulto , Idoso , Prótese de Cotovelo , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Medição da Dor , Próteses e Implantes , Falha de Prótese , Amplitude de Movimento Articular , Reoperação , Estudos Retrospectivos
3.
Inflamm Res ; 63(2): 139-47, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24189711

RESUMO

OBJECTIVE: We have previously demonstrated the efficient and time-dependent transvascular localization of Sialyl Lewis X (SLX)-liposomes to inflammatory sites, but the final target of the SLX-liposomes remained uncertain. The aim of this study was to identify the target cells of the liposomes within the inflamed joints of collagen antibody-induced arthritis (CAIA) model mice. METHODS: SLX-liposomes and unlabeled liposomes encapsulating high-density colloidal gold were administered intravenously into the caudal vein of CAIA mice on day 5 after induction of arthritis when the inflammatory score was maximal (n = 6 per group). Six hours or 24 h after liposome administration, animals were euthanized and hind limbs and ankles were excised without perfusion. After fixation, synovial tissues were examined by light microscopy after silver enhancement of colloidal gold or by transmission electron microscopy. RESULTS: Silver-enhanced signals were detected within the cells around E-selectin-positive blood vessels in the synovium of the SLX-liposome group. These cells were positive for the macrophage/monocyte marker F4/80 or neutrophil marker Ly-6G. Transmission electron microscopy detected the colloidal gold signals together with liposome-like structures within the phagosomes of synovial macrophages. Transmission electron microscopy and energy dispersive X-ray spectrometry could determine gold elements in the lysosomes of synovial macrophages. CONCLUSIONS: The results of the current study demonstrate that SLX-liposomes primarily targeting E-selectin in activated endothelial cells could potentially deliver their contents into inflammatory cells around synovial blood vessels in arthritic joints.


Assuntos
Artrite Experimental/metabolismo , Selectina E/metabolismo , Articulações do Pé/metabolismo , Coloide de Ouro/administração & dosagem , Macrófagos/metabolismo , Animais , Artrite Experimental/patologia , Articulações do Pé/patologia , Articulações do Pé/ultraestrutura , Articulação do Joelho/metabolismo , Articulação do Joelho/patologia , Articulação do Joelho/ultraestrutura , Lipossomos , Lisossomos/metabolismo , Lisossomos/ultraestrutura , Macrófagos/ultraestrutura , Camundongos , Camundongos Endogâmicos DBA , Microscopia/métodos , Microscopia Eletrônica de Transmissão , Oligossacarídeos/metabolismo , Antígeno Sialil Lewis X
4.
J Orthop Sci ; 19(1): 55-63, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24197059

RESUMO

BACKGROUND: We determined mid to long-term results of total elbow arthroplasty (TEA) by use of unlinked elbow prostheses with solid alumina ceramic trochleae, and ceramic ulnar stems (stemmed Kyocera type I; SKC-I) for patients with rheumatoid arthritis. PATIENTS AND METHODS: Fifty-four elbows of 39 patients were available for detailed clinical and radiographic review after a follow-up period of at least 5 years. The mean follow-up period was 12.6 years (range 5-22 years). Clinical condition before and after surgery was assessed by use of a modified version of the Mayo Elbow Performance Score (MEPS; 0-100 points) and a Japan Orthopaedic Association Elbow score (JOA score; 0-100 points). The radiographs were reviewed and loosening was defined as a progressive radiolucent line >1 mm wide that was completely circumferential around the prosthesis. Clinical records of post-operative events affecting the elbows were used for survival analysis of the prostheses using the Kaplan-Meier method. RESULTS: The average modified MEPS and JOA scores improved significantly from 39.7 ± 14.3 to 44.7 ± 9.4, respectively, pre-operatively, to 89.7 ± 15.4 and 83.1 ± 12.8, respectively, post-operatively (P < 0.0001). The functional assessment score also improved from 4.9 ± 2.8 to 8.5 ± 3.3 points (P < 0.0001). With loosening or implant revision defined as end points, the likelihood of survival of the prosthesis for up to 20 years was 92.6% (95% confidence interval (CI), 85.6-100.0) or 86.3 % (95 % CI 75.0-97.6), respectively. CONCLUSION: Satisfactory clinical results were obtained after TEA using SKC-I prostheses, which provided excellent pain relief and functional range of motion. The results of our study reveal the high reliability over a long period of the cemented SKC-I prosthesis with an alumina ceramic component.


Assuntos
Óxido de Alumínio , Artrite Reumatoide/cirurgia , Artroplastia de Substituição do Cotovelo/métodos , Cimentos Ósseos , Articulação do Cotovelo/cirurgia , Previsões , Prótese Articular , Adulto , Idoso , Artrite Reumatoide/diagnóstico , Artrite Reumatoide/fisiopatologia , Articulação do Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Desenho de Prótese , Radiografia , Amplitude de Movimento Articular , Estudos Retrospectivos
5.
J Spinal Disord Tech ; 20(6): 462-7, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17970188

RESUMO

STUDY DESIGN: A human cadaveric biomechanical study of fixation strength of an improved novel pedicle screw (NPS) with cement and a conventional screw. OBJECTIVE: To clarify whether the NPS has adequate fixation strength without leakage in vertebrae with low bone quality. SUMMARY OF BACKGROUND DATA: The fixation strength of pedicle screws decreases in frail spines of elderly osteoporotic patients. Augmentation of screw fixation with bone cement must be balanced against increased difficulty of screw removal and risk of cement leakage. We developed the NPS consisting of an internal screw and an outer sheath to mitigate the disadvantages of cement augmentation. METHODS: The T12 and L1 vertebrae obtained from 18 formalin preserved cadavers (11 males and 7 females; mean age, 82.7 y) were used. The mean bone mineral density was 0.39 +/- 0.14 g/cm2. The NPS was inserted into one pedicle of each vertebra and the control screw, a Compact CD2 screw, was inserted into the contralateral pedicle. Both screws were 6mm in diameter and 40 mm in length. Pull-out tests were performed at a crosshead speed of 10 mm/min. Cyclic loading tests were performed with a maximum 250 N load at 2 Hz until 30,000 cycles. RESULTS: Cement leakage did not occur in any of the specimens tested. The mean maximum force at pull-out was 760 +/- 344 N for the NPS and 346 +/- 172N for the control screw (P < 0.01). Loosening of 50% of the screws was observed after 17,000 cycles of the NPS and after 30 cycles of the control screw. The hazard ratio of loosening was 19.6 (95% confidence interval 19.3-19.9) (P < 0.001). CONCLUSIONS: The NPS showed a significantly higher mechanical strength than the control screw in both pull-out tests and cyclic loading tests. The NPS showed more than adequate strength without cement leakage.


Assuntos
Cimentos Ósseos/uso terapêutico , Parafusos Ósseos , Fixadores Internos , Vértebras Lombares/cirurgia , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Vértebras Torácicas/cirurgia , Idoso , Idoso de 80 Anos ou mais , Cadáver , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Vértebras Lombares/fisiopatologia , Masculino , Vértebras Torácicas/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA