Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
JAMA ; 294(10): 1215-23, 2005 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-16160130

RESUMO

CONTEXT: Compared with bare metal stents, drug-eluting stents reduce restenosis in noncomplex lesions. The utility of drug-eluting stents has not been evaluated in more difficult stenoses. OBJECTIVE: To investigate the safety and efficacy of the polymer-based, slow-release paclitaxel-eluting stent in a patient population with more complex lesions than previously studied. DESIGN, SETTING, AND PATIENTS: Prospective, placebo-controlled, double-blind, multicenter randomized trial conducted from February 2003 to March 2004 at 66 academic and community-based institutions with 1156 patients who underwent stent implantation in a single coronary artery stenosis (vessel diameter, 2.25-4.0 mm; lesion length, 10-46 mm), including 664 patients (57.4%) with complex or previously unstudied lesions (requiring 2.25-mm, 4.0-mm, and/or multiple stents) and 9-month clinical and angiographic follow-up. INTERVENTIONS: Patients were randomly assigned to receive 1 or more bare metal stents (n = 579) or identical-appearing paclitaxel-eluting stents (n = 577). MAIN OUTCOME MEASURE: Ischemia-driven target vessel revascularization at 9 months. RESULTS: Baseline characteristics were well matched. Diabetes was present in 31% of patients. The mean (SD) reference vessel diameter was 2.69 (0.57) mm, the reference lesion length was 17.2 (9.2) mm, and 78% of lesions were type B2/C. A mean (SD) of 1.38 (0.58) stents (total mean [SD] length, 28.4 [13.1] mm) were implanted per lesion; 33% of lesions required multiple stents. Stents that were 2.25 mm and 4.0 mm in diameter were used in 18% and 17% of lesions, respectively. Compared with bare metal stents, paclitaxel-eluting stents reduced the 9-month rate of target lesion revascularization from 15.7% to 8.6% (P<.001) and target vessel revascularization from 17.3% to 12.1% (P = .02). Similar rates were observed for cardiac death or myocardial infarction (5.5% for bare metal stent group vs 5.7% for paclitaxel-eluting stent group) and stent thrombosis (0.7% in both groups). Angiographic restenosis was reduced from 33.9% to 18.9% in the entire study cohort (P<.001), including among patients receiving 2.25-mm stents (49.4% vs 31.2%; P = .01), 4.0-mm stents (14.4% vs 3.5%; P = .02), and multiple stents (57.8% vs 27.2%; P<.001). CONCLUSION: Compared with a bare metal stent, implantation of the paclitaxel-eluting stent in a patient population with complex lesions effectively reduces clinical and angiographic restenosis.


Assuntos
Doença da Artéria Coronariana/terapia , Imunossupressores/administração & dosagem , Paclitaxel/administração & dosagem , Stents , Idoso , Angioplastia Coronária com Balão , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/prevenção & controle , Método Duplo-Cego , Sistemas de Liberação de Medicamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polímeros , Radiografia
2.
J Am Coll Cardiol ; 51(16): 1543-52, 2008 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-18420096

RESUMO

OBJECTIVES: The aim was to compare safety and effectiveness of the CoStar drug-eluting stent (DES) (Conor MedSystems, Menlo Park, California) with those of the Taxus DES (Boston Scientific, Maple Grove, Minnesota) in de novo single- and multivessel percutaneous coronary intervention (PCI). BACKGROUND: Paclitaxel elution from a stent coated with biostable polymer (Taxus) reduces restenosis after PCI. The CoStar DES is a novel stent with laser-cut reservoirs containing bioresorbable polymer loaded to elute 10 microg paclitaxel/30 days. METHODS: Patients undergoing PCI for a single target lesion per vessel in up to 3 native epicardial vessels were randomly assigned 3:2 to CoStar or Taxus. Primary end point was 8-month major adverse cardiac events (MACE), defined as adjudicated death, myocardial infarction (MI), or clinically driven target vessel revascularization (TVR). Protocol-specified 9-month angiographic follow-up included 457 vessels in 286 patients. RESULTS: Of the 1,700 patients enrolled, 1,675 (98.5%) were evaluable (CoStar = 989; Taxus = 686), including 1,330 (79%) single-vessel and 345 (21%) multivessel PCI. The MACE rate at 8 months was 11.0% for CoStar versus 6.9% for Taxus (p < 0.005), including adjudicated death (0.5% vs. 0.7%, respectively), MI (3.4% vs. 2.4%, respectively), and TVR (8.1% vs. 4.3%, respectively). Per-vessel 9-month in-segment late loss was 0.49 mm with CoStar and 0.18 mm with Taxus (p < 0.0001). Findings were consistent across pre-specified subgroups. CONCLUSIONS: The CoStar DES is not noninferior to the Taxus DES based on per-patient clinical and per-vessel angiographic analyses. The relative benefit of Taxus is primarily attributable to reduction in TVR. Follow-up to 9 months showed no apparent difference in death, MI, or stent thrombosis rates.


Assuntos
Implantes Absorvíveis , Antineoplásicos Fitogênicos/administração & dosagem , Ligas de Cromo , Doença da Artéria Coronariana/tratamento farmacológico , Reestenose Coronária/tratamento farmacológico , Paclitaxel/administração & dosagem , Polímeros , Angioplastia Coronária com Balão , Antineoplásicos Fitogênicos/uso terapêutico , Clopidogrel , Angiografia Coronária , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Reestenose Coronária/mortalidade , Reestenose Coronária/fisiopatologia , Diabetes Mellitus , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/uso terapêutico , Inibidores da Agregação Plaquetária/administração & dosagem , Risco , Tromboembolia/prevenção & controle , Ticlopidina/administração & dosagem , Ticlopidina/análogos & derivados , Fatores de Tempo
3.
J Am Coll Cardiol ; 49(16): 1676-83, 2007 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-17448368

RESUMO

OBJECTIVES: The goal of this research was to assess non-inferiority of the next-generation TAXUS Liberté stent (Boston Scientific Corp., Natick, Massachusetts) versus the TAXUS Express stent (Boston Scientific Corp.). BACKGROUND: The introduction of drug-eluting stents (DES) has shifted clinical practice towards more complex lesion subsets, prompting the need for more deliverable DES. TAXUS Liberté was designed to combine the established polymer-based, paclitaxel-elution TAXUS technology with the more advanced Liberté stent platform. METHODS: The TAXUS ATLAS study is a global, prospective, single-arm trial evaluating outcomes in de novo coronary lesions visually estimated to be 10 to 28 mm in length in vessels 2.5 to 4.0 mm in diameter. The control group is an entry-criteria-matched population of TAXUS Express patients from the TAXUS IV and V trials. The primary end point is non-inferiority of TAXUS Liberté versus TAXUS Express for 9-month target vessel revascularization. RESULTS: Despite similar inclusion criteria, quantitative coronary angiography-determined baseline lesion characteristics were significantly more complex for TAXUS Liberté than TAXUS Express. The primary non-inferiority end point was met with the 1-sided 95% confidence bound of 2.98% less than the pre-specified non-inferiority margin of 3% (p = 0.0487). CONCLUSIONS: Despite the treatment of more complex lesions with TAXUS Liberté, the primary end point was met, demonstrating that TAXUS Liberté is non-inferior to TAXUS Express. The successful transfer of the proven TAXUS technology to the more advanced TAXUS Liberté platform was demonstrated. (TAXUS ATLAS: TAXUS Liberté-SR Stent for the Treatment of De Novo Coronary Artery Lesions; http://www.clinicaltrials.gov/ct/show/NCT00371709?order=1; NCT00371709).


Assuntos
Estenose Coronária/tratamento farmacológico , Neovascularização Fisiológica/efeitos dos fármacos , Paclitaxel/administração & dosagem , Stents , Moduladores de Tubulina/administração & dosagem , Idoso , Determinação de Ponto Final , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polímeros , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA