Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Oral Rehabil ; 49(6): 608-615, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35334120

RESUMO

BACKGROUND: The masseter muscle has a complicated multipennate internal structure and exhibits functional differentiation when performing various stomatognathic functions. It is important to understand the internal structural changes of the muscle during functioning to elucidate characteristic muscle disorders such as local myalgia. Diffusion tensor imaging (DTI) may be useful for investigating the internal structural features of muscle. OBJECTIVES: To evaluate the features of masseter muscle fibres in human participants using DTI fibre tractography, and to elucidate the structural differences in the masseter muscle between the mandibular rest and open positions. METHODS: Five healthy men (age 31 ± 7 years) underwent DTI and T1-weighted MRI of the right masseter muscle in the mandibular rest and open positions. MR images were used as a reference for muscle layer segmentation (superficial, intermediate, and deep). DTI fibre tractography of the masseter muscle was performed and the orientation of the DTI fibres was analysed in each layer using coordinates based on the Frankfurt horizontal plane. RESULTS: The DTI fibre orientation of the deep layer significantly changed between the mandibular rest and open positions in the frontal plane (p < 0.05, Wilcoxon rank sum test). However, no significant change was found in the superficial and intermediate layers. CONCLUSION: DTI fibre tractography confirmed regional differences in the orientation change of the masseter muscle fibres between different mandibular positions. The results may support the existence of functional partitioning inside the masseter muscle and suggest that DTI may be useful for the evaluation of muscle fibres in multipennate muscles.


Assuntos
Imagem de Tensor de Difusão , Músculo Masseter , Adulto , Imagem de Tensor de Difusão/métodos , Humanos , Imageamento por Ressonância Magnética , Masculino , Mandíbula/diagnóstico por imagem , Músculo Masseter/diagnóstico por imagem , Músculo Masseter/fisiologia , Fibras Musculares Esqueléticas , Adulto Jovem
2.
J Prosthet Dent ; 2022 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-35491260

RESUMO

STATEMENT OF PROBLEM: Loss of retention is a clinical complication for fixed partial dentures (FPDs). However, a method sensitive enough to measure the early retention loss of FPDs is lacking. PURPOSE: The purpose of this in vitro and finite element analysis (FEA) study was to determine whether resonance frequency analysis (RFA) with a newly developed system can detect lack of FPD retention caused by cement loss. MATERIALS AND METHODS: Two evaluation methods were used: RFA of an in vitro model of a 3-unit FPD from the second premolar to the second molar and FEA by using a simplified model. The in vitro model was used to evaluate 4 connecting conditions: both crowns cemented, only the premolar crown cemented, only the molar crown cemented, and both crowns uncemented. Tapping stimulation (16 impulsive forces, 4 Hz) was directly applied to the buccal side of the second molar or the second premolar, and an attached 3D accelerometer sensor was used to record the resonance frequency (RF) of the tapped tooth. The amplitude, frequency, Q-value, and total area under the curve (AUC) of the RF values in the buccolingual direction were compared between connecting conditions. The FEA was done by using a simplified model of a 3-unit FPD with similar connecting conditions as the in vitro model study, and the RF amplitude and frequency of each tooth were calculated. Statistical evaluation included 1-way analysis of variance and the Tukey HSD test to compare the differences among each connecting condition under each parameter for measurement sites on the molar and the premolar, respectively (α=.05). RESULTS: For both the molar and premolar measurements in both the in vitro and FEA models, when the measurement site was on the uncemented tooth, the amplitude of RF-1 increased, the Q-value of RF-2 decreased, and the area under the curve increased (P<.05). CONCLUSIONS: The same 3 trends found between the measurement sites of the in vitro study and FEA indicated that RFA may be useful for detecting an FPD with loosening caused by cement loss, even partial cement loss.

3.
Clin Oral Implants Res ; 32(5): 641-650, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33711168

RESUMO

OBJECTIVES: The aims of this study were (i) to compare the osteogenic impact of low-intensity pulsed ultrasound (LIPUS) and low-magnitude high-frequency (LMHF) loading achieved with whole-body vibration (WBV) on peri-implant bone healing and implant osseointegration in rat tibiae, and (ii) to examine their combined effect on these processes. MATERIAL AND METHODS: Titanium implants were inserted in the bilateral tibiae of 28 Wistar rats. Rats were randomly divided into four groups: LIPUS + WBV, LIPUS, WBV, and control. LIPUS was applied to the implant placement site for 20 min/day on 5 days/week (1.5 MHz and 30 mW/cm2 ). WBV was applied for 15 min/day on 5 days/week (50 Hz and 0.5 g). In the LIPUS + WBV group, both stimuli were applied under the same stimulation conditions as in the LIPUS and WBV groups. After 4 weeks of treatment, peri-implant bone healing and implant osseointegration were assessed using removal torque (RT) tests, micro-CT analyses of relative gray (RG) value, and histomorphometrical analyses of bone-to-implant contact (BIC) and peri-implant bone formation (BV/TV). RESULTS: The LIPUS + WBV group had significantly greater BIC than the WBV and control groups. Although there were no significant intergroup differences in RT, RG value, and BV/TV, these variables tended to be greater in the LIPUS + WBV group than the other groups. CONCLUSIONS: The combination of LIPUS and LMHF loading may promote osteogenic activity around the implant. However, further study of the stimulation conditions of LIPUS and LMHF loading is necessary to better understand the osteogenic effects and the relationship between the two stimuli.


Assuntos
Implantes Dentários , Osteogênese , Animais , Osseointegração , Ratos , Ratos Wistar , Ondas Ultrassônicas , Vibração
4.
Eur J Oral Sci ; 126(5): 400-410, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30059170

RESUMO

The aims were to test the hypotheses that experimental masseter muscle pain leads to recruitment and/or derecruitment of motor units at different sites within the masseter and that the patterns of change in motor unit activity differ between sites. Single motor unit (SMU) activity was recorded at two sites within the right masseter [superior/anterior, inferior/posterior (IP)] during isometric biting tasks (ramp, step level) on an intraoral force transducer in 17 participants during three experimental blocks comprising no infusion (baseline), 5% hypertonic saline infusion (pain), or isotonic saline infusion (control). A visual analog scale (VAS) was used to score pain intensity. The VAS scores were statistically significantly greater during infusion of hypertonic saline than during infusion of isotonic saline. No significant differences in force levels and rates of force change were found between experimental blocks. In comparison with isotonic saline infusion, SMUs could be recruited and derecruited at both sites during hypertonic saline infusion. The frequency of recruitment or derecruitment, in comparison with no change, was statistically significantly greater at the IP site than at the superior/anterior site. Experimental noxious masseter stimulation results in a reorganization of motor unit activity throughout the muscle, and the pattern of reorganization may be different in different regions of the muscle.


Assuntos
Força de Mordida , Músculo Masseter/fisiologia , Músculos da Mastigação/fisiologia , Mialgia/fisiopatologia , Recrutamento Neurofisiológico/fisiologia , Potenciais de Ação/fisiologia , Adulto , Eletromiografia/métodos , Feminino , Humanos , Contração Isométrica/fisiologia , Soluções Isotônicas , Masculino , Pessoa de Meia-Idade , Mialgia/psicologia , Medição da Dor , Estimulação Física/instrumentação , Solução Salina Hipertônica , Inquéritos e Questionários , Análise e Desempenho de Tarefas
5.
Clin Oral Investig ; 22(5): 2129-2134, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29705965

RESUMO

OBJECTIVE: The aim of this study was to evaluate implant screw loosening using resonance frequency (RF) analysis with triaxial piezoelectric pick-up in vitro and in vivo. METHODS: For the in vitro experiment, a titanium implant was inserted into a mandibular model. The abutment screws were tightened to 10 N torque and loosened from 0 to 90° for RF measurement using 13 different screw conditions. In the in vivo experiment, three titanium implants were installed in each tibia of a New Zealand white rabbit, and the RF values were recorded after 8 weeks. For the RF analyses, a small 3D accelerometer was mounted rigidly onto the implant abutment, and impulsive vibration was directly applied to the abutment to vibrate the implant in a direction perpendicular to the tibia and implant (x-axis). The y-axis was defined as parallel to the tibia. The RF values of the x- and y-axis directions (RF-X and RF-Y) were used for evaluation. RESULTS: The RF values significantly decreased according to the degree of screw loosening (p < 0.05, ANOVA). In the in vitro model, RF-Y with x- and y-axis vibrations (RF-Yx and RF-Yy) significantly differed from the initial value at 10 and 15°, respectively (p < 0.05, Dunnett's test). In the in vivo experiment, the RF-Yy significantly differed from the initial value between 5 and 20° (p < 0.05). CONCLUSION: The results suggest that RF analysis with triaxial piezoelectric pick-up can be used to detect implant screw loosening. CLINICAL RELEVANCE: RF analysis with the triaxial piezoelectric pick-up can be used to detect screw loosening after mounting the superstructure.


Assuntos
Parafusos Ósseos , Implantes Dentários , Falha de Restauração Dentária , Análise de Frequência de Ressonância , Acelerometria/instrumentação , Animais , Implantes Experimentais , Mandíbula/cirurgia , Teste de Materiais , Coelhos , Tíbia/cirurgia , Titânio , Vibração
6.
Odontology ; 106(1): 90-95, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28215005

RESUMO

Oral appliance (OA) can effectively treat obstructive sleep apnea; however, numerous types of oral appliances and designs are variable and the precise mechanisms behind differences in treatment outcomes are uncertain. The objective of this study was to evaluate the effects of different degrees of mandibular position [4° of bite openings (BO): 2, 4, 8 and 12 mm; and protrusion (P): 0, 50%, MAX], for both the upright and supine positions: BO2 mm_P0%, BO4 mm_P0%, BO4 mm_P50%, BO4 mm_PMAX, BO8 mm_P0%, BO12 mm_P0%; with an OA on the: (1) activity of the genioglossus (GG) muscle by electromyogram, (2) inspiration by airflow sensor, and (3) recording mandibular movements (incisor and mandibular condyle point) in each position. Nine healthy male adults (age 27.5 ± 1.30 years) were recruited. The results show that GG muscle activity increased significantly from BO 4 mm_P0% to BO12 mm_P0% during the supine position, and the strongest signal was found in BO4 mm_PMAX, compared to all of the other positions, and GG muscle activity in BO4 mm_P0% tended to be lower. From supine to upright position the inspiration increased significantly but GG muscle activity did not. These results might be a stimulus to augment a compensatory mechanism of GG muscle induced by OA, however, mainly in protrusion position. The increase of BO (2-12 mm) and even maximum protrusion might not negatively affect the temporomandibular joint.


Assuntos
Músculos Faciais/fisiologia , Mandíbula/fisiologia , Aparelhos Ortodônticos , Apneia Obstrutiva do Sono/terapia , Adulto , Oclusão Dentária , Eletromiografia , Músculos Faciais/fisiopatologia , Humanos , Registro da Relação Maxilomandibular , Masculino , Mandíbula/fisiopatologia , Postura , Apneia Obstrutiva do Sono/fisiopatologia , Resultado do Tratamento
7.
Odontology ; 106(3): 232-237, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29236176

RESUMO

This study aimed to examine the dynamic change in bone metabolism by immediate loading in several sites around implants using high-resolution Na18F-PET scan. Two titanium implants (Ø 1.2 mm) were inserted parallel to each other in the right tibiae of Wistar rats (n = 4). The left tibia was set as control side. One day after insertion, closed coil springs of 4.0 N were attached to the expose superior portions of the implants to apply a continuous mechanical stress. The rats with fluorine-18 (18F) ion (5 mCi/rat) intravenously injected were scanned by PET scanner at 4, 7, 14, 28 days after load application. Round region of interests (ROIs) were set around the distal implant of the right tibia (loaded side) and same site (control) of the left tibia. Furthermore, four rectangular ROIs were set at the superior and inferior parts of traction side (mesial) and opposite side (distal) of the distal implant. Longitudinal dynamic changes in bone metabolism were evaluated by examination of the accumulation count of 18F ion at each ROI. The uptake values of ROIs (loaded side) initially increased until 7 days, and they gradually decreased from the peak level to the pre-loading level despite a static force being applied to the implants. In cancellous bone, the uptake values at the superior part of traction side and inferior part of opposite side showed significantly high value compared with those at other parts. In conclusion, immediate loading to the implant initially enhanced bone metabolism around it, especially at the part with compressive stress. Peri-implant bone metabolism varies according to different loading conditions.


Assuntos
Implantes Dentários , Radioisótopos de Flúor/farmacocinética , Carga Imediata em Implante Dentário , Tomografia por Emissão de Pósitrons , Fluoreto de Sódio/farmacocinética , Tíbia/metabolismo , Tíbia/cirurgia , Animais , Força Compressiva , Implantes Experimentais , Modelos Animais , Ratos , Ratos Wistar , Propriedades de Superfície , Tíbia/diagnóstico por imagem , Titânio
8.
Clin Oral Investig ; 21(6): 2029-2037, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27838843

RESUMO

OBJECTIVE: This study aimed to examine the influence of immediate loading on the dynamic changes of bone metabolism around dental implants using a high-resolution semiconductor sodium 18F-fluoride (Na18F)-PET. METHODS: Tibiae of 12 adult male rats were divided into 4 groups: immediate loading (IL), no loading (NL), bone defect (BD), and control (CTR). For the IL group, a 4.0-N load was applied continuously by two closed-coil springs attached between two implants in tibia. Each rat received an intravenous injection of Na18F and was scanned by high-resolution Na18F-PET at day 1 and then at weeks 1, 2, 3, 4, 5, 6, and 8 after surgery. Bone metabolism around the implant was evaluated by standardized uptake value (SUV), which indicates the outcome of Na18F accumulation. CT scanning was also performed, and PET and CT images were superposed to determine the anatomical orientation in PET images. RESULTS: Bone metabolism peaked at 7 days after surgery and then gradually decreased in all three test groups (IL, NL, and BD). SUVs of all three test groups were significantly higher than the baseline at 1, 2, 3, and 4 weeks after surgery, with SUVs in the IL group returning to baseline levels earlier than those in the NL and BD groups. CONCLUSIONS: Fluorine integrates preferentially with the initial low-calcified bone; thus, our results suggest that immediate loading promotes the calcification of the bone tissue in the early stage on peri-implant bone formation. CLINICAL RELEVANCE: Na18F-PET allows for an estimate of bone metabolism change around the implant.


Assuntos
Implantes Dentários , Radioisótopos de Flúor , Carga Imediata em Implante Dentário , Implantes Experimentais , Tomografia por Emissão de Pósitrons , Tíbia/metabolismo , Tíbia/cirurgia , Animais , Masculino , Modelos Animais , Ratos , Ratos Wistar , Tíbia/diagnóstico por imagem
9.
Implant Dent ; 25(4): 515-9, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27356200

RESUMO

INTRODUCTION: The mechanisms by which the loads exerted on implants that support prostheses are modulated during mastication remain unclear. The purpose of this study was to evaluate the effects of food texture on 3-dimensional loads measured at a single implant using a piezoelectric transducer. MATERIALS AND METHODS: Two subjects participated in this study. The transducer and the experimental superstructure, which had been adjusted to the subject's occlusal scheme, were attached to the implant with a titanium screw. The foods tested were chewing gum and peanuts. RESULTS: The mean maximum load on the implant in each chewing cycle was significantly higher during peanut chewing than during gum chewing. The direction of maximum load was significantly more widely dispersed during peanut chewing than during gum chewing. The range of changes in load direction during the force-increasing phase of each chewing cycle was significantly wider during peanut chewing than during gum chewing. CONCLUSIONS: The load on the implant was affected by food texture in both subjects. This measurement method can be useful to investigate the mechanisms of load modulation on implants during mastication.


Assuntos
Implantes Dentários , Alimentos , Mastigação , Adulto , Arachis/efeitos adversos , Goma de Mascar/efeitos adversos , Análise do Estresse Dentário/métodos , Feminino , Alimentos/efeitos adversos , Humanos , Pessoa de Meia-Idade , Transdutores de Pressão , Suporte de Carga/fisiologia
10.
Clin Oral Implants Res ; 26(2): 191-6, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24325598

RESUMO

OBJECTIVE: To evaluate the effect of implant insertion torque on the peri-implant bone healing and implant osseointegration. MATERIAL AND METHODS: Bilaterally in the tibia of five adult New Zealand white rabbits, 20 implants were installed, subdivided into four groups, corresponding to two insertion torque conditions (low, < 10 Ncm vs. high > 50 Ncm) and 2 experimental periods (2 weeks vs. 4 weeks of healing). The implant insertion torque was determined by the surgical drill diameter relative to the implant diameter. Implant osseointegration was evaluated by quantitative histology (bone-to-implant contact with host bone [BIC-host], with neoformed bone [BIC-de novo], with both bone types [BIC-total], and peri-implant bone [BA/TA]). Every response was modelled over time using GEE (general estimation equation) with an unstructured variance-covariance matrix to correct for dependency between the measurements from one animal. The statistical significance level of α = 0.05 was applied. RESULTS: Significantly, more BIC-host and BIC-total were recorded for H implants compared with L implants after 2 week of healing (P = 0.010 and P = 0.0001, respectively). However, this result was no longer found for the extended healing period. Furthermore, BIC-total significantly increased over time for L implants (P < 0.00001). In contrast, the significant increase in BA/TA over time was found for H implants (P < 0.01). Finally, H insertion torque led to an increased BA/TA after 4 week of healing (P < 0.02) compared with the L insertion protocol. CONCLUSION: L insertion torque implants installed in the rabbit tibial bone osseointegrate with considerable de novo bone formation. This bone neoformation enables L implants to catch up, already during the early osseointegration stage, the initial inferior amount BIC contact compared with that of H implants. A negative impact of the created strain environment accompanying H insertion torque implant installation on the biological process of osseointegration could not be observed, at least not at tissue level.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários , Implantes Experimentais , Osseointegração , Tíbia/cirurgia , Animais , Masculino , Osteogênese , Coelhos , Estresse Mecânico , Tíbia/patologia , Titânio , Torque
11.
Sleep Breath ; 19(3): 857-63, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25578466

RESUMO

PURPOSE: Mandibular advancement splints (MAS) can effectively treat obstructive sleep apnea (OSA); however, treatment response is variable, and the mechanisms behind differences in treatment outcomes are still not well understood. The aims of this study were (1) to assess the effects of MAS on tongue shape and (2) to compare tongue shape changes with MAS between treatment responders and nonresponders. METHODS: Sixty-eight adults with symptomatic mild to severe OSA were included. A custom-made MAS was provided to patients, and treatment outcome was determined by polysomnography. Two-dimensional tongue measurements were evaluated using sagittal and axial MRI image slices without and with MAS in situ. Tongue measurements of height, length, width, area, and shape (height/length) were collected. Additional measurements of surrounding upper airway structures, soft palate length width and area and upper airway area, length and minimum width were measured on sagittal image slices. RESULTS: Based on polysomnography with MAS in situ, 47 patients were classified as responders (≥50% reduction in apnea-hypopnea index [AHI] from baseline), and 21 were nonresponders (<50% AHI reduction). There was no change in sagittal tongue area with insertion of MAS, although there was a change in most of parameters of tongue shape. Responders showed a greater decrease in tongue length with MAS in situ compared to nonresponders (-0.64 ± 0.46 vs -0.32 ± 0.51 cm, p = 0.016). CONCLUSION: This study reports a detailed two-dimensional analysis of tongue dimensions as well as assessment of adjacentsoft palate shape and upper airway structures without and with MAS treatment for OSA. Our finding suggests that MAS does induce changes in tongue shape. MAS treatment responders showed a greater decrease in tongue length (between the tongue tip and hyoid bone) with MAS in situ; whether differences in alteration of tongue position with MAS explain differences in treatment response requires further investigation.


Assuntos
Avanço Mandibular/instrumentação , Placas Oclusais , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/terapia , Língua/fisiopatologia , Adulto , Idoso , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão/fisiologia , Polissonografia , Apneia Obstrutiva do Sono/diagnóstico , Resultado do Tratamento
12.
Clin Oral Implants Res ; 25(9): 1084-90, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23802506

RESUMO

OBJECTIVES: The aim of this study was to examine the influence of immediate and early loading on dynamic changes in bone metabolism around dental implants using bone scintigraphy. MATERIAL AND METHODS: Two titanium implants were inserted in the right tibiae of 21 rats. Closed coil springs with 4.0-N loads were applied parallel to the upper portion of the implants for 35 days. According to the load application timing, rats were divided into three groups: immediate loading (IL) group, early loading 1 day after implant insertion (1-D early loading [EL]) group, and loading 3 days after implant insertion (3-D EL) group. Rats were intravenously injected with technetium-99 m-methylene diphosphonate (Tc99 m-MDP) (74 MBq/rat) and scanned by bone scintigraphy at 1, 4, 7, 11, 14, 21, 28, and 35 days after load application. The ratio of accumulation of Tc99 m-MDP around the implants to that of a reference site (uptake ratio) was calculated to evaluate bone metabolism. RESULTS: In every group, the uptake ratio increased until 7 days after load application and then gradually decreased. It was significantly higher than baseline at 4, 7, 11, and 14 days (P < 0.001). The uptake ratio in the 1-D EL and 3-D EL groups were significantly higher than that in the control group and also that in the IL group (P < 0.001). CONCLUSIONS: Bone metabolism initially increased and then gradually decreased to baseline despite differences in load timing. Increases in bone metabolic activity differed according to load application timing; the later the load application, the more enhanced the bone metabolism.


Assuntos
Implantes Dentários , Carga Imediata em Implante Dentário , Implantes Experimentais , Tíbia/metabolismo , Tíbia/cirurgia , Animais , Planejamento de Prótese Dentária , Masculino , Cintilografia , Compostos Radiofarmacêuticos , Ratos , Ratos Wistar , Medronato de Tecnécio Tc 99m , Tíbia/diagnóstico por imagem , Titânio
13.
J Prosthodont Res ; 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38383001

RESUMO

PURPOSE: This study aimed to determine the usefulness of machine learning techniques, specifically supervised and unsupervised learning, for assessing the cementation condition between a fixed partial denture (FPD) and its abutment using a resonance frequency analysis (RFA) system. METHODS: An in vitro mandibular model was used with a single crown and three-unit bridge made of a high-gold alloy. Two cementation conditions for the single crown and its abutment were set: cemented and uncemented. Four cementation conditions were set for the bridge and abutments: both crowns were firmly cemented, only the premolar crown was cemented, only the molar crown was cemented, and both crowns were uncemented. For RFA under cementation conditions, 16 impulsive forces were directly applied to the buccal side of the tested tooth at a frequency of 4 Hz using a Periotest device. Frequency responses were measured using a 3D accelerometer mounted on the occlusal surface of the tested tooth. Both supervised and unsupervised learning methods were used to analyze the datasets. RESULTS: Using supervised learning, the fully cemented condition had the highest feature importance scores at approximately 3000 Hz; the partially cemented condition had the highest scores between 1000 and 2000 Hz; and the highest scores for the uncemented condition were observed between 0 and 500 Hz. Using unsupervised learning, the uncemented and partially cemented conditions exhibited the highest anomaly scores. CONCLUSIONS: Machine learning combined with RFA exhibits good potential to assess the cementation condition of an FPD and hence facilitate the early diagnosis of FPD retention loss.

14.
J Biomed Mater Res B Appl Biomater ; 112(7): e35447, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38997799

RESUMO

With dental implant treatment becoming the gold standard, the need for effective bone augmentation prior to implantation has grown. This study aims to evaluate a bone augmentation strategy integrating three key growth factors: bone morphogenetic protein-2 (BMP-2), insulin-like growth factor 1 (IGF-1), and vascular endothelial growth factor (VEGF). Collagen scaffolds incorporating BMP-2, IGF-1, or VEGF were fabricated and categorized into five groups based on their content: scaffold alone; BMP-2 alone (BMP-2); BMP-2 and IGF-1 (BI); BMP-2, IGF-1, and VEGF (BIV); and BMP-2 and IGF-1 with an earlier release of VEGF (BI + V). The prepared scaffolds were surgically implanted into the calvarias of C57BL/6JJcl mice, and hard tissue formation was assessed after 10 and 28 days through histological, tomographic, and biochemical analyses. The combination of BMP-2 and IGF-1 induced a greater volume of hard tissue augmentation compared with that of BMP-2 alone, regardless of VEGF supplementation, and these groups had increased levels of cartilage compared with others. The volume of hard tissue formation was greatest in the BIV group. In contrast, the BI + V group exhibited a hard tissue volume similar to that of the BI group. While VEGF and CD31 levels were highest in the BIV group at 10 days, there was no correlation at the same time point between hard tissue formation and the quantity of M2 macrophages. In conclusion, the simultaneous release of BMP-2, IGF-1, and VEGF proved to be effective in promoting bone augmentation.


Assuntos
Proteína Morfogenética Óssea 2 , Fator de Crescimento Insulin-Like I , Fator A de Crescimento do Endotélio Vascular , Animais , Proteína Morfogenética Óssea 2/farmacologia , Camundongos , Fator de Crescimento Insulin-Like I/farmacologia , Fator de Crescimento Insulin-Like I/metabolismo , Fator A de Crescimento do Endotélio Vascular/metabolismo , Fator A de Crescimento do Endotélio Vascular/farmacologia , Alicerces Teciduais/química , Crânio/metabolismo , Camundongos Endogâmicos C57BL , Masculino
15.
Odontology ; 101(2): 222-6, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22743716

RESUMO

The aim of this study was to evaluate stress distribution in peri-implant bone and to investigate the influence of splinting implants by finite element analysis (FEA) with in vivo loading data. The magnitude and direction of the force exerted on implants during maximal voluntary clenching of a subject were recorded with 3-D piezoelectric force transducers. FEA using in vivo loading data was conducted on splinted and non-splinted models with two implants. Overall, the splinted model reduced stress in peri-implant bone in comparison with the non-splinted model.


Assuntos
Implantes Dentários , Análise de Elementos Finitos , Mandíbula/patologia , Estresse Fisiológico , Idoso , Feminino , Humanos
16.
Int J Implant Dent ; 9(1): 31, 2023 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-37725286

RESUMO

BACKGROUND: Appropriate load distribution among the supporting elements is essential for the long-term success of implant-assisted removable partial dentures; however, there is little information available on load distribution. PURPOSE: This study aimed to evaluate the effect of implant location on load distribution in implant-assisted removable partial dentures by reviewing in vitro models and finite-element analysis studies. MATERIALS AND METHODS: English-language studies which examined the load distribution of implant-assisted removable partial dentures and were published between January 2001 and October 2022 were extracted from PubMed, ScienceDirect, and Scopus online databases, and manual searching. Two reviewers selected the articles based on the predetermined inclusion and exclusion criteria, followed by data extraction and analysis. RESULTS: Forty-seven studies were selected after evaluating the titles and abstracts of 264 articles; two were identified manually. After screening the text, 12 studies were included: six in vitro model experiments and six finite-element analysis studies. All included studies used a mandibular free-end missing model (Kennedy Class I or II). The influence of implant location on load distribution to the abutment tooth, implant, and mucosa under the denture base was summarized in three cases: implant at the premolar, first molar, and second molar region. Due to differences in the measurement method of load distribution and loading condition to the denture, the results differed among the studies. CONCLUSIONS: The implant location in implant-assisted removable partial dentures can affect load distribution to the supporting elements, such as the abutment tooth, implant, and mucosa under the denture base.


Assuntos
Implantes Dentários , Prótese Parcial Removível , Dente Molar , Bases de Dados Factuais , Análise de Elementos Finitos
17.
Front Oral Health ; 4: 1170966, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37521175

RESUMO

Background: Orofacial pain conditions are complex disorders that involve biological, social, and psychological factors. Temporomandibular Disorders (TMDs) are one of the most common orofacial pain conditions, and our previous literature review indicated that exercise therapy has shown promise in reducing TMD-related pain. However, more evidence is needed to firmly establish its effectiveness. Objectives: This systematic review aims to investigate the effectiveness of exercise therapy on pain relief and jaw mobility in patients with pain-related TMDs. Methods: To include randomized controlled trials (RCTs) written in English, a literature search was performed using PubMed, Scopus, Web of Science, Cochrane Library, Ovid, EBM reviews, and Academic Search Complete initially from 4th November 2020 until March 2022. A PICOS for this review was as follows; P: Patients with TMD myalgia or arthralgia, I: Excursion exercise, Stretch exercises, Resistance exercise, or Coordination exercise, C: No treatment or education only. O: Pain intensity and Range of Motion (ROM), S: RCTs. After title screening, a full-text assessment was done to extract data. According to Risk of Bias (RoB) 2.0, risk of bias was assessed in each included paper by 2 reviewers independently. Results: A total of 3,388 titles were identified from the electronic database search. After the screening and full-text evaluation, only 5 studies (145 participants) were eligible to be included. Among the exercise modalities, coordination exercise showed a significant effect on pain relief and improvement of joint mobility. Discussion: Due to the heterogeneity and small sample size of the included studies, a meta-analysis was not feasible. However, this systematic review suggested that exercise therapy, especially coordinate exercise, can be effective in managing painful TMD conditions. Further research is needed to establish optimal parameters for this patient population, as well as standardization and consistency in terminology and treatment structure.

18.
J Prosthodont Res ; 66(1): 12-18, 2022 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-33692284

RESUMO

PURPOSE: Dental implant therapy is a common clinical treatment for missing teeth. However, the esthetic result is not as satisfactory as expected in some cases, especially in the anterior maxillary area. Poor esthetic results are caused by inadequate preparation of the hard and soft tissues in this area before treatment. The socket shield technique may be an alternative for a desirable esthetic outcome in dental implant treatments. STUDY SELECTION: In the present systematic review, PubMed-Medline, Google Scholar, and ScienceDirect were searched for clinical studies published from January 2000 to December 2018. RESULTS: Twenty studies were included, comprising one randomized controlled trial, two cohort studies, 14 clinical human case reports, and three retrospective case series. In total, 288 patients treated with the socket shield technique with immediate implant placement and follow-up between 3-60 months after placement were included. A quality assessment showed that 12 of the 20 included studies were of good quality. Twenty-six of the 274 (9.5%) cases developed complications or adverse effects related to the socket shield technique. Most studies reported implant survival without the complications (90.5%); most of the cases that were followed up for more than 12 months after implant placement achieved a good esthetic appearance. The failure rate was low without the complications, although there were some failures due to failed implant osseointegration, socket shield mobility and infection, socket shield exposure, socket shield migration, and apical root resorption. CONCLUSIONS: The socket shield technique can be used in dental implant treatment, but it remains difficult to predict the long-term success of this technique until high-quality evidence becomes available.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Carga Imediata em Implante Dentário , Implantação Dentária Endóssea , Estética Dentária , Humanos , Estudos Retrospectivos , Extração Dentária , Alvéolo Dental , Resultado do Tratamento
19.
Geriatr Gerontol Int ; 22(12): 1032-1039, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36408675

RESUMO

AIM: To examine the relationship between the number of present and functional teeth at baseline and future incidence of loss of independence. METHODS: Participants were community-dwelling older individuals who participated in a comprehensive geriatric health examination conducted in Kusatsu town, Japan, between 2009 and 2015. The primary endpoint was the incidence of loss of independence among participants, defined as the first certification of long-term care insurance in Japan. The numbers of present and functional teeth at baseline were determined via an oral examination. Demographics, clinical variables (e.g., history of chronic diseases and psychosocial factors), blood nutritional markers, physical functions, and perceived masticatory function were assessed. RESULTS: This study included 1121 individuals, and 205 individuals suffered from loss of independence during the follow-up period. Kaplan-Meier estimates of loss of independence for participants with smaller numbers of present and functional teeth were significantly greater than for those with larger numbers of teeth. Cox proportional hazard analyses indicated that a smaller number of present teeth was not a significant risk factor after adjusting for demographic characteristics. However, the number of functional teeth was a significant risk factor after the adjustment (hazard ratio: 1.975 [1.168-3.340]). Additionally, higher hazard ratios were observed in other adjusted models, but they were not statistically significant. CONCLUSIONS: The number of functional teeth may be more closely related to the future incidence of loss of independence than the number of present teeth. This novel finding suggests that prosthodontic rehabilitation for tooth loss possibly prevents the future incidence of this life-event. Geriatr Gerontol Int 2022; 22: 1032-1039.


Assuntos
Perda de Dente , Humanos , Idoso , Japão/epidemiologia , Perda de Dente/epidemiologia , Certificação , Vida Independente , Seguro de Assistência de Longo Prazo
20.
J Clin Periodontol ; 38(2): 180-5, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21062336

RESUMO

PURPOSE: to examine the influence of time of low-magnitude, high-frequency (LMHF) loading, whole-body vibration (WBV) on peri-implant bone healing. MATERIALS AND METHODS: a custom-made Ti implant was inserted into the medio-proximal site of one tibia of 95 rats and was left to heal for 1 or 4 weeks. The daily WBV consisted of 15 consecutive frequency steps (12, 20, 30, …, 150 Hz) at an acceleration of 0.3 g. The rats were divided into five groups with different loading times: 0 (control/non-loading), 1.25, 2.5, 5 and twice 1.25 min. (with an interim recovery period) of loading. Bone-to-implant contact (BIC) and peri-implant bone fraction were measured. RESULTS: BIC of every test group was significantly higher than that of the control group for both healing periods. In the 4-week healing group, BIC and BFs (in all region of interests) were significantly higher in the case of twice 1.25 min. of loading compared with 1.25 min. of loading. CONCLUSION: time of loading significantly influenced the effect of the WBV on peri-implant bone healing. Twice 1.25 min. of loading appears to have the most favourable effect. LMHF loading with a particular time sequence can stimulate peri-implant bone healing and formation.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários , Osseointegração/fisiologia , Osteogênese/fisiologia , Vibração , Análise de Variância , Animais , Masculino , Ratos , Ratos Wistar , Tíbia/cirurgia , Cicatrização/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA