RESUMO
BACKGROUND: Comparative data of durable polymer (DP) versus biodegradable polymer (BP) drug-eluting stents (DES) are limited in patients presenting with acute coronary syndrome (ACS) undergoing complex percutaneous coronary intervention (PCI). AIMS: We sought to evaluate the efficacy and safety of DP-DES and BP-DES in ACS patients receiving complex PCI. METHODS: This study was a post hoc analysis of the HOST-REDUCE-POLYTECH-ACS trial. ACS patients were randomly assigned 1:1 to DP-DES or BP-DES in the HOST-REDUCE-POLYTECH-ACS trial. Complex PCI was defined as having at least 1 of the following features: ≥3 stents implanted, ≥3 lesions treated, total stent length ≥60 mm, bifurcation PCI with 2 stents, left main PCI, or heavy calcification. Patient-oriented (POCO, a composite of all-cause death, non-fatal myocardial infarction, and any repeat revascularisation) and device-oriented composite outcomes (DOCO, a composite of cardiac death, target vessel myocardial infarction, or target lesion revascularisation) were evaluated at 12 months. RESULTS: Among 3,301 patients for whom full procedural data were available, 1,140 patients received complex PCI. Complex PCI was associated with higher risks of POCO and DOCO. The risks of POCO were comparable between DP-DES and BP-DES in both the complex (HR 0.87, 95% confidence interval [CI]: 0.57-1.33; p=0.522) and non-complex (HR 0.83, 95% CI: 0.56-1.24; p=0.368; p for interaction=0.884) PCI groups. DOCO was also not significantly different between DP-DES and BP-DES in both the complex (HR 0.74, 95% CI: 0.43-1.27; p=0.278) and non-complex (HR 0.67, 95% CI: 0.38-1.19; p=0.175; p for interaction=0.814) PCI groups. CONCLUSIONS: In ACS patients, DP-DES and BP-DES showed similar clinical outcomes irrespective of PCI complexity.
Assuntos
Síndrome Coronariana Aguda , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Stents Farmacológicos/efeitos adversos , Síndrome Coronariana Aguda/cirurgia , Síndrome Coronariana Aguda/complicações , Polímeros , Everolimo , Implantes Absorvíveis , Sirolimo , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento , Infarto do Miocárdio/etiologiaRESUMO
Background This study sought to investigate the safety of 3-month dual antiplatelet therapy (DAPT) in patients receiving ultrathin sirolimus-eluting stents with biodegradable polymer (Orsiro). Methods and Results The SMART-CHOICE (Smart Angioplasty Research Team: Comparison Between P2Y12 Antagonist Monotherapy vs Dual Anti- platelet Therapy in Patients Undergoing Implantation of Coronary Drug-Eluting Stents) randomized trial compared 3-month DAPT followed by P2Y12 inhibitor monotherapy with 12-month DAPT in 2993 patients undergoing percutaneous coronary intervention. The present analysis was a prespecified subgroup analysis for patients receiving Orsiro stents. As a post hoc analysis, comparisons between Orsiro and everolimus-eluting stents were also done among patients receiving 3-month DAPT. Of 972 patients receiving Orsiro stents, 481 patients were randomly assigned to 3-month DAPT and 491 to 12-month DAPT. At 12 months, the target vessel failure, defined as a composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization, occurred in 8 patients (1.7%) in the 3-month DAPT group and in 14 patients (2.9%) in the 12-month DAPT group (hazard ratio [HR], 0.58; 95% CI, 0.24-1.39; P=0.22). In whole population who were randomly assigned to receive 3-month DAPT (n=1495), there was no significant difference in the target vessel failure between the Orsiro group and the everolimus-eluting stent group (n=1014) (1.7% versus 1.8%; HR, 0.96; 95% CI, 0.41-2.22; P=0.92). Conclusions In patients receiving Orsiro stents, clinical outcomes at 1 year were similar between the 3-month DAPT followed by P2Y12 inhibitor monotherapy and 12-month DAPT strategies. With 3-month DAPT, there was no significant difference in target vessel failure between Orsiro and everolimus-eluting stents. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT02079194.
Assuntos
Aspirina , Plásticos Biodegradáveis/farmacologia , Clopidogrel , Doença da Artéria Coronariana/cirurgia , Reestenose Coronária , Stents Farmacológicos/efeitos adversos , Intervenção Coronária Percutânea , Sirolimo/farmacologia , Idoso , Aspirina/administração & dosagem , Aspirina/efeitos adversos , Clopidogrel/administração & dosagem , Clopidogrel/efeitos adversos , Reestenose Coronária/diagnóstico , Reestenose Coronária/etiologia , Reestenose Coronária/mortalidade , Terapia Antiplaquetária Dupla/métodos , Feminino , Humanos , Imunossupressores/farmacologia , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Inibidores da Agregação Plaquetária/administração & dosagem , Inibidores da Agregação Plaquetária/efeitos adversos , Antagonistas do Receptor Purinérgico P2Y/administração & dosagem , Antagonistas do Receptor Purinérgico P2Y/efeitos adversosRESUMO
BACKGROUND: There are limited data on the frequency of and factors associated with quantitative coronary angiography (QCA)-defined longitudinal stent deformation (LSD) in various contemporary drug-eluting stents platforms. This study sought to evaluate the predictors of LSD and its long-term clinical implication. METHODS AND RESULTS: A patient-level pooled analysis was performed with 7350 lesions in 5871 patients treated with platinum-chromium-based everolimus-eluting stent (Promus Element), cobalt-chromium-based everolimus-eluting stent (Promus/Xience V), or cobalt-chromium-based zotarolimus-eluting stent (Endeavor Resolute). QCA was performed to analyze differences of stent length between immediate post-deployment and final post-procedure. Independent factors associated with LSD were identified. Clinical outcomes at 3 years were compared between those with and without QCA-based LSD. The frequency of QCA-based LSD was 1.12% (82 cases). Nine of these cases were angiographically overt. Left main or ostial lesion, bifurcation treatment with provisional side branch stenting or ballooning, additional downstream intervention of a distal lesion, intravascular ultrasound use, and adjunctive post-dilatation were independently associated with QCA-based LSD. The type of stent was not associated with QCA-based LSD. Rates of target lesion failure were nominally higher in lesions with QCA-based LSD than in those without (8.97% versus 5.88%; hazard ratio, 1.415; 95% confidence interval, 0.631-3.175; P=0.399). CONCLUSIONS: LSD is uncommon with contemporary drug-eluting stents, regardless of the type of stent platform. LSD is mainly associated with procedural factors, especially with additional downstream procedures which require the passage of devices through the stent. Careful manipulation of poststent imaging or procedural devices is required to prevent LSD. More data are needed to clarify the impact of LSD on clinical events.
Assuntos
Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Fármacos Cardiovasculares/administração & dosagem , Ligas de Cromo , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Bases de Dados Factuais , Everolimo/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Platina , Desenho de Prótese , Falha de Prótese , República da Coreia , Fatores de Risco , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de IntervençãoRESUMO
BACKGROUND: Antiplatelet treatment is an important component in optimizing the clinical outcomes after percutaneous coronary intervention (PCI) especially in patients with acute coronary syndrome (ACS). Prasugrel, which is a new P2Y12 inhibitor, has been confirmed as efficacious in a large trial in Western countries, and a similar trial is also to be launched in Asian countries. Although a 60-mg loading dose of prasugrel followed by 10 mg per day should be acceptable, there have been no data regarding the optimal dose in Asian patients. Furthermore, serum levels of prasugrel and the rates of platelet inhibition are known to be higher in Asians than Caucasians with the same dose of the drug. Polymer, a key component of drug-eluting stents (DES), has been suggested as the cause of inflammation leading to late complications, and has driven many companies to develop biodegradable-polymer DES. Currently, there are limited data regarding the head-to-head comparison between BP-BES and the biostable polymer CoCr-EES or the newest platinum-chromium everolimus-eluting stent (PtCr-EES). Furthermore, the polymer issue may be more important in ACS where there is ruptured thrombotic plaque where polymer-induced inflammation may affect the local milieu of the stented artery. Therefore, the present study dedicated only to ACS patients, will offer important information on the optimal prasugrel dose in the Asian population by comparing a 10-mg versus a 5-mg maintenance dose beyond 1 month after PCI, as well as giving important insight into the polymer issue by comparing BP-BES versus biostable-polymer PtCr-EES. METHOD/DESIGN: Harmonizing Optimal Strategy for Treatment of coronary artery diseases--comparison of REDUCtion of prasugrEl dose or POLYmer TECHnology in ACS patients (HOST-REDUCE-POLYTECH-ACS) trial is a multicenter, randomized and open-label clinical study with a 2 × 2 factorial design, according to the type of stent (PtCr-EES versus BP-BES) and prasugrel maintenance dose (5 mg versus 10 mg), to demonstrate non-inferiority of PtCr-EES relative to BP-BES or the reduced prasugrel dose relative to conventional dose in an Asian all-comers PCI population presenting with ACS. Approximately 3400 patients will undergo prospective, random assignment separately to either stent or prasugrel arm (1:1 ratio, respectively). When the patients have contraindications to prasugrel, they are categorized into an antiplatelet observation group after stent-randomization. The primary endpoint is the patient-oriented composite outcome, which is a composite of all-cause mortality, any myocardial infarction (MI), any repeat revascularization in the stent arm at 12 months after index PCI. In the prasugrel arm, primary endpoint is any major adverse cardiovascular event, which is a composite of all-cause mortality, any MI, any stent thrombosis (Academic Research Consortium (ARC)-defined), any repeat revascularization, stroke, or bleeding (BARC class ≥ 2). DISCUSSION: The HOST-REDUCE-POLYTECH-ACS RCT is the first study exploring the optimal maintenance dose of prasugrel beyond 1 month after PCI for ACS in Asian all-comers. In addition, this is the largest study dedicated only to ACS patients to evaluate the polymer issue in the situation of ACS by directly comparing biostable-polymer PtCr-EES versus BP-BES. TRIAL REGISTRATION: ClinicalTrials.gov (ID: NCT02193971, 13 July 2014).