Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Endovasc Ther ; 23(3): 424-32, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27044270

RESUMO

PURPOSE: To identify intravascular ultrasound (IVUS) measurements that can predict angiographic in-stent restenosis (ISR) following nitinol stent implantation in superficial femoral artery (SFA) lesions. METHODS: A retrospective review was conducted of 97 patients (mean age 72.9±8.9 years; 63 men) who underwent IVUS examination during endovascular treatment of 112 de novo SFA lesions between July 2012 and December 2014. Self-expanding bare stents were implanted in 46 lesions and paclitaxel-eluting stents in 39 lesions. Six months after stenting, follow-up angiography was conducted to assess stent patency. The primary endpoint was angiographic ISR determined by quantitative vascular angiography analysis at the 6-month follow-up. Variables associated with restenosis were sought in multivariate analysis; the results are presented as the odds ratio (OR) and 95% confidence interval (CI). RESULTS: At follow-up, 27 (31.8%) angiographic ISR lesions were recorded. The lesions treated with uncoated stents were more prevalent in the ISR group compared with the no restenosis group (74.1% vs 44.8%, p=0.02). Lesion length was longer (154.4±79.5 vs 109.0±89.3 mm, p=0.03) and postprocedure minimum stent area (MSA) measured by IVUS was smaller (13.9±2.8 vs 16.3±1.6 mm(2), p<0.001) in the ISR group. Multivariate analysis revealed that bare stent use (OR 7.11, 95% CI 1.70 to 29.80, p<0.01) and longer lesion length (OR 1.08, 95% CI 1.01 to 1.16, p=0.04) were predictors of ISR, while increasing postprocedure MSA (OR 0.58, 95% CI 0.41 to 0.82, p<0.01) was associated with lower risk of ISR. Receiver operating characteristic analysis identified a MSA of 15.5 mm(2) as the optimal cutpoint below which the incidence of restenosis increased (area under the curve 0.769). CONCLUSION: Postprocedure MSA can predict ISR in SFA lesions, which suggests that adequate stent enlargement during angioplasty might be required for superior patency.


Assuntos
Ligas , Angiografia , Angioplastia com Balão/instrumentação , Constrição Patológica , Artéria Femoral/diagnóstico por imagem , Doença Arterial Periférica/terapia , Stents , Ultrassonografia de Intervenção , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/efeitos adversos , Área Sob a Curva , Fármacos Cardiovasculares/administração & dosagem , Distribuição de Qui-Quadrado , Stents Farmacológicos , Feminino , Artéria Femoral/fisiopatologia , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Paclitaxel/administração & dosagem , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Valor Preditivo dos Testes , Desenho de Prótese , Curva ROC , Recidiva , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
2.
Cardiovasc Interv Ther ; 38(2): 210-222, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36255689

RESUMO

BACKGROUND: Mechanism of femoropopliteal in-stent restenosis has been underappreciated. AIM: The aim of this animal study was to elucidate vascular response after femoropopliteal bare nitinol self-expanding stents (SESs) implantation. METHODS: Misago, Smart Flex, or Innova stent was randomly implanted in 36 swine femoropopliteal arteries. At week 4, quantitative vessel analysis (QVA) was performed on 36 legs, of which 18 underwent histological evaluation after angiography. The remaining 18 legs underwent QVA and histological evaluation at week 13. RESULTS: Fibrin deposition was excessive at week 4. Internal elastic lamina (IEL) progressively enlarged over time, and vessel injury developed from mild level at week 4 to moderate level at week 13. Vessel inflammatory reaction was mild to moderate at week 4, and was moderate to severe at week 13. Increased fibrin deposition was an early-acting, IEL enlargement and increased vessel inflammation were long-acting, and increased vessel injury and giant cells infiltration were late-acting contributors to neointimal hyperplasia (NIH). Stent type altered time-dependent process of vessel injury, vessel inflammation, eosinophils and giant cells infiltration. Misago had less fibrin deposition and vessel enlargement, and less progressive vessel injury, vessel inflammation, and eosinophils and giant cells infiltration. Net lumen as assessed by percent diameter stenosis or minimum lumen diameter was preserved with Misago, but was not preserved with the other stents. CONCLUSIONS: In the context of bare nitinol SES platform with less progressive mechanical stress and inflammatory reaction, the advantage of less NIH outweighed the disadvantage of less vessel enlargement, leading to net lumen preservation.


Assuntos
Artéria Femoral , Stents , Animais , Ligas , Artéria Femoral/cirurgia , Artéria Femoral/patologia , Fibrina , Desenho de Prótese , Stents/efeitos adversos , Suínos , Resultado do Tratamento
3.
EuroIntervention ; 19(5): e402-e413, 2023 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-37395475

RESUMO

BACKGROUND: There are no randomised trials reporting clinical outcomes of biodegradable polymer biolimus-eluting stents (BP-BES) and durable polymer everolimus-eluting stents (DP-EES) at 10 years. AIMS: We aimed to compare the 10-year clinical outcomes between BP-BES and DP-EES. METHODS: The randomised NOBORI Biolimus-Eluting Versus XIENCE/PROMUS Everolimus-eluting Stent Trial (NEXT) was originally designed to evaluate the non-inferiority of BP-BES relative to DP-EES with the primary efficacy endpoint of target lesion revascularisation (TLR) at 1 year and the primary safety endpoint of death or myocardial infarction (MI) at 3 years. In this extended follow-up study, clinical outcomes were compared from 1 year after stent implantation up to 10 years between patients with BP-BES and DP-EES. RESULTS: From May to October 2011, NEXT enrolled a total of 3,241 patients from 98 centres in Japan. The current study population consisted of 2,417 patients (1,204 patients with BP-BES and 1,213 with DP-EES) from 66 centres that agreed to participate in the extended study. Complete 10-year follow-up was achieved in 87.5% of patients. The cumulative 10-year incidence of death or MI was 34.0% in the BP-BES group and 33.1% in the DP-EES group (hazard ratio [HR] 1.04, 95% confidence interval [CI]: 0.90-1.20; p=0.58). TLR occurred in 15.9% of patients in the BP-BES group and in 14.1% of the DP-EES group (HR 1.12, 95% CI: 0.90-1.40; p=0.32). In a landmark analysis at 1 year, the cumulative incidences of death or MI and TLR were not significantly different between the 2 groups. CONCLUSIONS: The safety and efficacy outcomes for BP-BES were not significantly different from those for DP-EES at 1 year and up to 10 years after stent implantation.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Implantes Absorvíveis , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/complicações , Stents Farmacológicos/efeitos adversos , Everolimo/uso terapêutico , Seguimentos , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Sirolimo/uso terapêutico , Resultado do Tratamento
4.
JACC Cardiovasc Interv ; 13(1): 116-127, 2020 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-31918929

RESUMO

OBJECTIVES: The aim of this study was to investigate the vascular responses and fates of the scaffold after bioresorbable vascular scaffold (BVS) implantation using multimodality imaging. BACKGROUND: Serial comprehensive image assessments after BVS implantation in the context of a randomized trial have not yet been reported. METHODS: In the ABSORB Japan trial, 400 patients were randomized to a BVS (n = 266) or a cobalt-chromium everolimus-eluting stent (n = 134). Through 3 years, patients underwent serial angiography and intravascular ultrasound or optical coherence tomography (OCT). RESULTS: Luminal dimension at 3 years was consistently smaller with the BVS than with the cobalt-chromium everolimus-eluting stent (mean angiographic minimal luminal diameter 2.04 ± 0.63 mm vs. 2.40 ± 0.56 mm, mean difference -0.37 mm [95% confidence interval: -0.50 to -0.24 mm]; p < 0.001), mainly because of smaller device area (6.13 ± 2.03 mm2 vs. 7.15 ± 2.16 mm2, mean difference -1.04 mm2 [95% confidence interval: -1.66 to -0.42 mm2]; p < 0.001), and larger neointimal area (2.10 ± 0.61 mm2 vs. 1.86 ± 0.64 mm2, mean difference 0.24 mm2 [95% confidence interval: 0.06 to 0.43 mm2]; p = 0.01) by OCT. BVS-treated vessels did not show previously reported favorable vessel responses, such as positive vessel remodeling, late luminal enlargement, and restoration of vasomotion, although the OCT-based healing score was on average zero (interquartile range: 0.00 to 0.00). At 3 years, intraluminal scaffold dismantling (ISD) was observed in 14% of BVS. On serial OCT, ISD was observed in 6 lesions at 2 years, where the struts had been fully apposed at post-procedure, while ISD was observed in 12 lesions at 3 years, where 8 lesions were free from ISD on 2-year OCT. In 5 cases of very late scaffold thrombosis, strut discontinuities were detected in all 4 cases with available OCT immediately before reintervention. CONCLUSIONS: In this multimodality serial imaging study, luminal dimension at 3 years was smaller with the BVS than with the cobalt-chromium everolimus-eluting stent. ISD, suspected to be one of the mechanisms of very late BVS thrombosis, was observed in a substantial proportion of cases at 3 years, which developed between post-procedure and 2 years and even beyond 2 years. (AVJ-301 Clinical Trial: A Clinical Evaluation of AVJ-301 [Absorb™ BVS] in Japanese Population [ABSORB JAPAN]; NCT01844284).


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Ligas de Cromo , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Everolimo/administração & dosagem , Imagem Multimodal , Intervenção Coronária Percutânea/instrumentação , Stents , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/etiologia , Everolimo/efeitos adversos , Humanos , Japão , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Método Simples-Cego , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA