Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Interv Cardiol ; 2020: 6340716, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33380923

RESUMO

AIMS: The goal of this study was to evaluate the performance of the InspironTM coronary stent (Scitech Medical™, Goiás, Brazil). The InspironTM sirolimus-eluting stent uses an ultrathin L-605 cobalt-chromium alloy with a 75 µm strut thickness platform coated with an abluminal biodegradable polymer. The polymer is eliminated from the body through the tricarboxylic acid cycle in 6-9 months, releasing 80% of the drug within 30 days after its deployment. METHODS: It was a prospective, single-center registry. To represent clinical practice, all patients undergoing percutaneous coronary intervention were included in this registry. There were no exclusion criteria. Clinical follow-ups were performed at twelve months. The endpoints were the occurrence of all-cause death, definite stent thrombosis, and new revascularization. RESULTS: Between November 2017 and May 2019, 790 patients were included (1067 lesions). The mean age was 60.42 ± 14.94 years, and 74.7% presented with acute coronary syndrome. Diabetes mellitus was present in 43.9% of patients, and previous myocardial infarction and previous percutaneous coronary intervention were present in 17.9% and 11.3%, respectively. Angiographic success was achieved in 99.1%. The incidence of all-cause death was 11.5% (6.2% in-hospital and 5.3% in the follow-up) and definitive stent thrombosis was 0.2%. New revascularization was performed in only 5.8% (target lesion revascularization: 2.2%; progression of disease in another lesion: 3.6%). Based on the multivariate regression analysis, only chronic renal failure was an independent predictor of adverse events (OR: 3.3; 95% CI: 1.22-8.92). CONCLUSION: The result of this single-center registry demonstrates the safety and excellent performance of the InspironTM stent in daily clinical practice with a low rate of adverse cardiac events.


Assuntos
Síndrome Coronariana Aguda , Plásticos Biodegradáveis/farmacologia , Ligas de Cromo/farmacologia , Stents Farmacológicos/efeitos adversos , Intervenção Coronária Percutânea , Sirolimo/farmacologia , Síndrome Coronariana Aguda/mortalidade , Síndrome Coronariana Aguda/cirurgia , Brasil/epidemiologia , Materiais Revestidos Biocompatíveis/farmacologia , Reestenose Coronária/epidemiologia , Reestenose Coronária/etiologia , Reestenose Coronária/cirurgia , Feminino , Humanos , Imunossupressores/farmacologia , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros/estatística & dados numéricos , Reoperação/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA