Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Medicina (Kaunas) ; 58(7)2022 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-35888588

RESUMO

Background and Objectives: We aimed to develop a cranial suture traction therapy program, a non-surgical therapeutic method for facial asymmetry correction. Materials and Methods: Six experts, including rehabilitation medicine specialists, oriental medical doctors, dentistry specialists, five experts, including Master's or doctoral degree holders in skin care and cosmetology with more than 10 years of experience in the field, 4 experts including educators in the field of skin care, a total of 15 people participated in the validation of the development of the cranial suture traction therapy program in stages 1 to 3. Open questions were used in the primary survey. In the second survey, the results of the first survey were summarized and the degree of agreement regarding the questions in each category was presented. In the third survey, the degree of agreement for each item in the questionnaire was analyzed statistically. Results: Most of the questions attained a certain level of consensus by the experts (average of ≥ 4.0). The difference between the mean values was the highest for the third survey at 0.33 and was the lowest between the second and third surveys at 0.47. The results regarding the perceived degree of importance for each point of the evaluation in both the second and third stages of the cranial suture traction therapy program were verified using the content validity ratio. The ratio for the 13 evaluation points was within the range of 0.40-1.00; thus, the Delphi program for cranial suture traction therapy verified that the content was valid. Conclusions: As most questions attained a certain level of consensus by the experts, it can be concluded that these questions are suitable, relevant, and important. The commercialization of the cranial suture traction treatment program will contribute to the correction and prevention of facial dislocations or asymmetry, and the developed treatment will be referred to as cranial suture traction therapy (CSTT).


Assuntos
Suturas Cranianas , Tração , Técnica Delphi , Assimetria Facial/terapia , Humanos , Inquéritos e Questionários
2.
Medicina (Kaunas) ; 56(11)2020 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-33207656

RESUMO

The complete removal of obturation material can be a challenge in nonsurgical root canal retreatment. The insufficient removal of obturation material is a reason for root canal retreatment failure. The purpose of this study was to assess the efficacy of different final root canal irrigation activation methods in removing debris and smear layers in the apical and middle portions of root canals during retreatment. Sixty-six distal roots of freshly extracted molars were randomly divided into six groups: (1) primary root canal treatment with no obturation (negative control); (2) retreatment with only conventional instrumentation and irrigation (positive control); (3) retreatment with additional ultrasonic irrigation using the Piezon Master 700; (4) ultrasonic irrigation with the ENDOSONIC Blue; (5) sonic irrigation with the EDDY; and (6) multisonic irrigation with the GentleWave system. Roots were split and prepared for scanning electron microscopic (SEM) evaluation. Acquired images were assessed to quantify the amount of debris and smear remaining. Among the treatment groups, Group 6 had a significantly lower debris score than Group 2 (positive control) in both the middle and apical regions (p = 0.004, p = 0.012). All treatment groups showed significantly lower smear scores than Group 2 in the middle and apical regions (p < 0.05). The GentleWave multisonic System showed a more optimal cleaning efficacy of the root canal debris but did not differ significantly with the tested passive ultrasonic or sonic irrigation method.


Assuntos
Camada de Esfregaço , Cavidade Pulpar , Humanos , Retratamento , Irrigantes do Canal Radicular , Preparo de Canal Radicular
3.
J Med Virol ; 91(11): 1995-2000, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31286531

RESUMO

There are no surrogate markers for the development of postherpetic neuralgia (PHN) in patients with herpes zoster (HZ). All patients with HZ were prospectively enrolled to evaluate the associations of saliva varicella zoster virus (VZV) DNA persistence and VZV-specific cell-mediated immunity (CMI) with the development of PHN. Slow clearers were defined if salivary VZV DNA persisted after day 15. Salivary VZV was detected in 60 (85.7%) of a total of 70 patients with HZ on initial presentation. Of 38 patients for whom follow-up saliva samples were available, 26 (68.4%) were classified as rapid clearers and 12 (31.6%) as slow cleares. Initial VZV-specific CMI was lower in slow clearers than rapid clearers (median 45 vs 158 spot forming cells/10 6 cells, P = .02). Of the 70 patients with HZ, 22 (31.4%) eventually developed PHN. Multivariate analysis showed that slow clearers (OR, 15.7, P = .01) and lower initial VZV-specific CMI (OR, 13.8, P = .04) were independent predictors of the development of PHN, after adjustment for age and immunocompromised status. Initial low VZV CMI response and persistence of VZV DNA in saliva may be associated with the development of PHN.


Assuntos
DNA Viral/análise , Herpes Zoster/complicações , Imunidade Celular , Neuralgia Pós-Herpética/etiologia , Saliva/virologia , Adulto , Idoso , Biomarcadores/análise , Feminino , Herpes Zoster/imunologia , Herpesvirus Humano 3 , Humanos , Masculino , Pessoa de Meia-Idade , Neuralgia Pós-Herpética/diagnóstico , Neuralgia Pós-Herpética/virologia , Estudos Prospectivos
4.
J Infect Dis ; 217(1): 51-57, 2017 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-29029120

RESUMO

Background: We evaluated the diagnostic usefulness of polymerase chain reaction (PCR) analysis for detecting varicella-zoster virus (VZV) infection and reactivation of VZV, using DNA extracted from saliva and plasma specimens obtained from subjects with suspected herpes zoster and from healthy volunteers during stressful and nonstressful conditions. Methods: There were 52 patients with a diagnosis of herpes zoster (group 1), 30 with a diagnosis of zoster-mimicking disease (group 2), and 27 healthy volunteers (group 3). Saliva and plasma samples were evaluated for VZV DNA by real-time PCR analysis. Results: Among patients with suspected herpes zoster (ie, patients in groups 1 and 2), the sensitivity of PCR analysis of salivary DNA for detecting VZV (88%; 95% confidence interval [CI], 74%-95%) was significantly higher than that of PCR analysis of plasma DNA (28%; 95% CI, 16%-44%; P < .001), whereas the specificity of PCR analysis of salivary DNA (100%; 95% CI, 88%-100%) was similar to that of PCR analysis of plasma DNA (100%; 95% CI, 78%-100%; P > .99). VZV DNA was not detected in saliva and plasma samples from group 3 (0%; 95% CI, 0%-14%). Conclusions: Real-time PCR analysis of salivary DNA is more sensitive than that of plasma DNA for detecting VZV among patients with suspected herpes zoster. We found no subclinical reactivation of VZV in group 3 following exposure to common stressful conditions.


Assuntos
DNA Viral/isolamento & purificação , Herpes Zoster/diagnóstico , Herpesvirus Humano 3/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , Plasma/virologia , Reação em Cadeia da Polimerase em Tempo Real/métodos , Saliva/virologia , Adulto , Idoso , Idoso de 80 Anos ou mais , DNA Viral/genética , Feminino , Herpesvirus Humano 3/genética , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Adulto Jovem
5.
ACS Appl Mater Interfaces ; 16(35): 46664-46676, 2024 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-39180554

RESUMO

Recent advances in numerous biological applications have increased the accuracy of monitoring the level of biologically significant analytes in the human body to manage personal nutrition and physiological conditions. However, despite promising reports about costly wearable devices with high sensing performance, there has been a growing demand for inexpensive sensors that can quickly detect biological molecules. Herein, we present highly sensitive biosensors based on organic electrochemical transistors (OECTs), which are types of organic semiconductor-based sensors that operate consistently at low operating voltages in aqueous solutions. Instead of the gold or platinum electrode used in current electrochemical devices, poly(3,4-ethylenedioxythiophene):poly(4-styrenesulfonate) (PEDOT:PSS) was used as both the channel and gate electrodes in the OECT. Additionally, to overcome the patterning resolution limitations of conventional solution processing, we confirmed that the irradiation of a high-power IR laser (λ = 1064 nm) onto the coated PEDOT:PSS film was able to produce spatially resolvable micropatterns in a digital-printing manner. The proposed patterning technique exhibits high suitability for the fabrication of all-PEDOT:PSS OECT devices. The device geometry was optimized by fine-tuning the gate area and the channel-to-gate distance. Consequently, the sensor for detecting ascorbic acid (vitamin C) concentrations in an electrolyte exhibited the best sensitivity of 125 µA dec-1 with a limit of detection of 1.3 µM, which is nearly 2 orders of magnitude higher than previous findings. Subsequently, an all-plastic flexible epidermal biosensor was established by transferring the patterned all-PEDOT:PSS OECT from a glass substrate to a PET substrate, taking full advantage of the flexibility of PEDOT:PSS. The prepared all-plastic sensor device is highly cost-effective and suitable for single-use applications because of its acceptable sensing performance and reliable signal for detecting vitamin C. Additionally, the epidermal sensor successfully obtained the temporal profile of vitamin C in the sweat of a human volunteer after the consumption of vitamin C drinks. We believe that the highly sensitive all-PEDOT:PSS OECT device fabricated using the accurate patterning process exhibits versatile potential as a low-cost and single-use biosensor for emerging bioelectronic applications.


Assuntos
Técnicas Biossensoriais , Lasers , Poliestirenos , Transistores Eletrônicos , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Poliestirenos/química , Humanos , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Ácido Ascórbico/análise , Ácido Ascórbico/química , Polímeros/química , Compostos Bicíclicos Heterocíclicos com Pontes/química , Eletrodos , Suor/química , Tiofenos
6.
Materials (Basel) ; 12(21)2019 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-31731396

RESUMO

The purpose of this study was to compare disinfection and the biofilm removal efficacy of the GentleWave System (Sonendo, Inc., Laguna Hills, CA, USA) with passive ultrasonic activation method. Forty-seven freshly extracted human molars were inoculated with Enterococcus faecalis and cultured for five weeks to establish biofilm. Eight molars were tested for confirmation of infection. Four of the eight teeth were not inoculated in order to provide a negative control. The remaining 39 inoculated molars were randomly separated into three treatment groups (n = 13 per group): Group 1-no treatment, Group 2-conventional rotary instrumentation and passive ultrasonic activation, and Group 3-minimal instrumentation and the GentleWave System treatment. Roots were subsequently prepared per standard histological tissue processing procedures. Modified Brown and Brenn stained sections and Hematoxylin and Eosin stained sections were visualized at 4× and 13.5× magnification using a stereomicroscope. The sections were scored and blindly analyzed by two independent evaluators, including a histopathologist, to evaluate the presence of biofilm on canal wall. A significant difference was found between Group 2 and Group 3 in both apical and middle regions (p = 0.001) of the mesial roots of mandibular molars and mesiobuccal roots of maxillary molars. Group 3 revealed significantly less biofilm than the controls (p = 0.003). The GentleWave System demonstrated significantly greater reduction in biofilm within the mesial roots of mandibular molars and mesiobuccal roots of maxillary molars than those treated with conventional rotary instrumentation and passive ultrasonic activation protocol.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA