Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 298
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Orthod Craniofac Res ; 27(1): 102-109, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37496461

RESUMO

OBJECTIVE: This finite element analysis (FEA) aimed to assess the stress distribution in the mandible and fixation system with various directions of the intermaxillary fixation (IMF) using mini-implants (MIs) and elastics following mandibular advancement with a bilateral sagittal split ramus osteotomy (BSSRO). MATERIALS AND METHODS: A total of nine mandibular advancement models were set according to the position of the MIs (1.6 mm in diameter, 8 mm in length) and direction of the IMF elastics (1/4 inch, 5 oz). Major and minor principal stresses in the cortical and cancellous bones, von Mises stresses in the fixation system (miniplate and monocortical screws), and bending angles of the miniplate were analysed. RESULTS: Compressive and tensile stress distributions in the mandible and von Mises stress distributions in the fixation system were greater in models with a Class III IMF elastic direction and a higher IMF elastic force than in models with a Class II IMF elastic direction and a lower IMF elastic force. The bending angle of the miniplate was negligible. CONCLUSIONS: Stress distributions in the bone and fixation system varied depending on the direction, amount of force, and position of IMF elastics and MIs. Conclusively, IMF elastics in the Class II direction with minimal load in the area close to the osteotomy site should be recommended.


Assuntos
Implantes Dentários , Avanço Mandibular , Procedimentos de Ancoragem Ortodôntica , Osteotomia Sagital do Ramo Mandibular , Análise de Elementos Finitos , Placas Ósseas , Parafusos Ósseos , Estresse Mecânico , Mandíbula/cirurgia
2.
Int J Mol Sci ; 25(12)2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38928161

RESUMO

Magnoliae Flos (MF) is a medicinal herb widely employed in traditional medicine for relieving sinusitis, allergic rhinitis, headaches, and toothaches. Here, we investigated the potential preventive effects of MF extract (MFE) against 4-vinylcyclohexene diepoxide (VCD)-induced ovotoxicity in ovarian cells and a mouse model of premature ovarian insufficiency (POI). The cytoprotective effects of MFE were assessed using CHO-K1 or COV434 cells. In vivo, B6C3F1 female mice were intraperitoneally injected with VCD for two weeks to induce POI, while MFE was orally administered for four weeks, beginning one week before VCD administration. VCD led to a significant decline in the viabilities of CHO-K1 and COV434 cells and triggered excessive reactive oxygen species (ROS) production and apoptosis specifically in CHO-K1 cells. However, pretreatment with MFE effectively prevented VCD-induced cell death and ROS generation, while also activating the Akt signaling pathway. In vivo, MFE increased relative ovary weights, follicle numbers, and serum estradiol and anti-Müllerian hormone levels versus controls under conditions of ovary failure. Collectively, our results demonstrate that MFE has a preventive effect on VCD-induced ovotoxicity through Akt activation. These results suggest that MFE may have the potential to prevent and manage conditions such as POI and diminished ovarian reserve.


Assuntos
Cricetulus , Ovário , Extratos Vegetais , Insuficiência Ovariana Primária , Espécies Reativas de Oxigênio , Animais , Feminino , Camundongos , Células CHO , Insuficiência Ovariana Primária/induzido quimicamente , Insuficiência Ovariana Primária/prevenção & controle , Ovário/efeitos dos fármacos , Ovário/metabolismo , Ovário/patologia , Extratos Vegetais/farmacologia , Extratos Vegetais/química , Espécies Reativas de Oxigênio/metabolismo , Apoptose/efeitos dos fármacos , Compostos de Vinila/farmacologia , Cicloexenos/farmacologia , Proteínas Proto-Oncogênicas c-akt/metabolismo , Modelos Animais de Doenças , Transdução de Sinais/efeitos dos fármacos
3.
BMC Oral Health ; 24(1): 865, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39080607

RESUMO

BACKGROUND: Recent studies have reported the inhomogeneity in the light emitted by dental light-curing units (LCUs). It is essential to understand how this uneven light distribution affects the physical properties of resin-based composites (RBCs) at various points across their surfaces. This study aimed to evaluate the effect of LCU beam's inhomogeneity on the microhardness of RBCs with different shades and thicknesses. METHODS: Four body (A1B, A2B, A3B, and A4B), one dentin (A3D), and one enamel shade (A3E) of RBC (Filtek Z350 XT) were examined. The specimens were fabricated in four thicknesses (1, 2, 3, and 4 mm) and subjected to a 40-second light-curing. Vickers microhardness testing was performed at the center point, and 3 mm left and right from the center at the bottom surface of each sample. The LCU beam profile was characterized using a beam profiler, while irradiance after specimen passage was measured using a spectrometer. One-way analysis of variance (ANOVA) and Tukey's post-hoc tests were used to analyze the effects of shades and thicknesses on irradiance and microhardness, respectively. One-way repeated-measures ANOVA was used to compare the microhardness across different points. Pearson's correlation analysis examined the relationship between irradiance and microhardness. RESULTS: The beam profile of LCU revealed inhomogeneous light distribution. Light irradiance was decreased with both the increase in thickness and darker shade of the specimens (p < 0.05). Microhardness was found to decline with an increase in sample thickness (p < 0.05), and was consistently higher at the center point compared to the periphery, particularly in thicker (3 and 4 mm) and darker shades (A3B, A4B, and A3D). A positive correlation was found between the irradiance and microhardness across all evaluated points (p < 0.05). CONCLUSIONS: Inhomogeneous light emission from LCU significantly influences the microhardness of RBC samples, depending on the thicknesses and shades. The findings underline the importance of considering LCU beam inhomogeneity in clinical settings to ensure optimal polymerization of RBC.


Assuntos
Cor , Resinas Compostas , Lâmpadas de Polimerização Dentária , Dureza , Teste de Materiais , Resinas Compostas/efeitos da radiação , Resinas Compostas/química , Humanos , Propriedades de Superfície , Cura Luminosa de Adesivos Dentários/métodos , Esmalte Dentário/efeitos da radiação , Dentina/efeitos da radiação , Materiais Dentários/efeitos da radiação , Materiais Dentários/química , Polimerização , Luz
4.
Environ Res ; 220: 115229, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36610536

RESUMO

Mercury (Hg) exposure is a public health problem worldwide that is now being addressed through the Minamata Convention on Mercury. Fish containing methylmercury and dental amalgam containing elemental Hg are the major sources of exposure for most populations. There is some evidence that methylmercury impacts cardiovascular and metabolic health, primarily in populations with high exposure levels. Studies of elemental Hg and these outcomes are relatively rare. We aimed to examine associations between Hg exposure (both elemental and methylmercury) and blood pressure, as well as cholesterol and triglyceride levels. In 2012, we recruited dental professionals attending the Health Screening Program at the American Dental Association (ADA) Annual Session in California. Total Hg levels in hair and blood samples were analyzed as indicators of methylmercury exposure and in urine as an indicator of primarily elemental Hg exposure (n = 386; mean ± sd age 55 ± 11 years). We measured blood pressure (systolic and diastolic) and lipid profiles (total cholesterol, high-density lipoprotein cholesterol [HDL], low-density lipoprotein cholesterol [LDL] and triglycerides). The geometric means (geometric standard deviations) for blood, hair, and urine Hg were 3.64 (2.39) µg/L, 0.60 (2.91) µg/g, and 1.30 (2.44) µg/L, respectively. For every one µg/L increase in specific gravity-adjusted urine Hg, LDL increased by 2.31 mg/dL (95% CI = 0.09, 4.54), in linear regression adjusting for BMI, race, sex, polyunsaturated fatty acid intake from fish consumption, smoking status, and use of cholesterol-lowering medication. No significant associations between Hg biomarkers and blood pressure or hair or blood Hg with lipid levels were observed. Results suggest that elemental Hg exposure may influence LDL concentrations in adults with low-level exposure, and this relationship merits further study in other populations.


Assuntos
Mercúrio , Compostos de Metilmercúrio , Animais , Humanos , Compostos de Metilmercúrio/toxicidade , Estudos Transversais , Pressão Sanguínea , Mercúrio/análise , Odontólogos , Lipídeos , Exposição Ambiental
5.
Medicina (Kaunas) ; 59(11)2023 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-38003948

RESUMO

Background and Objective: There is a paucity of literature comparing unilateral instrumented transforaminal lumbar interbody fusion (UITLIF) with bilateral instrumented TLIF (BITLIF) regarding radiological alignment, including the coronal balance, even though UITLIF might have asymmetric characteristics in the coronal plane. This retrospective study aimed to compare the clinical and long-term radiological outcomes of 1-level UITLIF and BITLIF in lumbar degenerative diseases (LDD) including lumbar spinal stenosis with or without spondylolisthesis (degenerative or spondylolytic). Materials and Methods: Patients who underwent 1-level UITLIF with two rectangular polyetheretherketone (PEEK) cages or BITLIF between November 2009 and June 2016 by four surgeons with ≥5 years of follow-up at a single hospital were included. We compared the clinical and radiological outcomes between the UITLIF and BITLIF. Results: In total, 63 and 111 patients who underwent UITLIF and BITLIF, respectively, were enrolled. The median follow-up was 85.55 months (range: 60-130). The UITLIF group had a significantly shorter operation time (185.0 [170.0-210.0] vs. 225.0 [200.0-265.0], p < 0.001) and lower estimated blood loss (300.0 [250.0-500.0] vs. 550.0 [400.0-800.0], p < 0.001) than the BITLIF group. Regarding the clinical outcomes, there were no significant differences in the intermittent claudication score (p = 0.495) and Kirkaldy-Willis criteria (p = 0.707) at 1 year postoperatively. The interval changes in the local coronal Cobb angle at the index level, L1-S1 lordotic angle, and coronal off-balance from the immediate postoperative radiograph to the last follow-up were not significantly different (p = 0.687, p = 0.701, and p = 0.367, respectively). Conclusions: UITLIF with two rectangular PEEK cages may provide comparable clinical outcomes and radiological longevity including coronal alignment to BITLIF in 1-level LDD. In addition, UITLIF has advantages over BITLIF in terms of operative time and blood loss.


Assuntos
Vértebras Lombares , Fusão Vertebral , Humanos , Seguimentos , Resultado do Tratamento , Vértebras Lombares/cirurgia , Estudos Retrospectivos , Polietilenoglicóis , Cetonas
6.
Anal Bioanal Chem ; 414(10): 3205-3217, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34617153

RESUMO

Sensitive and selective determination of protein biomarkers with high accuracy often remains a great challenge due to their existence in the human body at an exceptionally low concentration level. Therefore, sensing mechanisms that are easy to use, simple, and capable of accurate quantification of analyte are still in development to detect biomarkers at a low concentration level. To meet this end, we demonstrated a methodology to detect thrombin in serum at low concentration levels using polypyrrole (PPy)-palladium (Pd)nanoparticle-based hybrid transducers using liposomes encapsulated redox marker as a label. The morphology of Ppy-Pd composites was characterized by scanning electron microscopy, and the hybrid structure provided excellent binding and detection platform for thrombin detection in both buffer and serum solutions. For quantitative measurement of thrombin in PBS and serum, the change in current was monitored using differential pulse voltammetry, and the calculated limit of quantification (LOQ) and limit of detection (LOD) for the linear segment (0.1-1000 nM of thrombin) were 1.1 pM and 0.3 pM, in serum, respectively. The sensors also exhibited good stability and excellent selectivity towards the detection of thrombin, and thus make it a strong candidate for adopting its sensing applications in biomarker detection technologies.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Nanocompostos , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/métodos , Humanos , Limite de Detecção , Lipossomos , Paládio/química , Polímeros/química , Pirróis/química , Trombina/química
7.
J Gastroenterol Hepatol ; 37(2): 319-326, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34562328

RESUMO

BACKGROUND AND AIM: The efficacy and safety of the recently introduced low-volume purgatives in elderly people are not well known. Therefore, in this trial, we aimed to evaluate and compare the efficacy of two low-volume agents, oral sulfate solution (OSS) and 2-L polyethylene glycol with ascorbic acid (PEG-Asc), in elderly people. METHODS: A prospective, randomized, single-blinded, multicenter, non-inferiority trial was performed at three university-affiliated hospitals in South Korea. Outpatients aged 65-80 years, who underwent elective colonoscopy, were enrolled. The primary outcome was the rate of adequate bowel preparation assessed using the Boston Bowel Preparation Scale. RESULTS: A total of 199 subjects were randomized into the OSS (n = 99) or the 2-L PEG-Asc (n = 100) group. Of them, 189 subjects were included in the analysis of the primary outcome (OSS group 95 vs PEG-Asc group 94). The proportion of adequate bowel preparation was 89.5% (85/95) in the OSS group and 93.6% (88/94) in the 2-L PEG-Asc group. OSS was not inferior to 2-L PEG-Asc according to the prespecified non-inferiority margin of -15% (95% confidence interval for the difference, -12.1 to 3.8). Vomiting (11.6% vs 2.1%) and thirst (24.2% vs 11.7%) were more common in the OSS group than in the 2-L PEG-Asc group. CONCLUSIONS: OSS is an effective low-volume purgative that is non-inferior to 2-L PEG-Asc in elderly people. Both the low-volume agents were identified to be well tolerated and safe in the healthy elderly population.


Assuntos
Ácido Ascórbico , Catárticos , Polietilenoglicóis , Sulfatos , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Ácido Ascórbico/administração & dosagem , Ácido Ascórbico/efeitos adversos , Catárticos/administração & dosagem , Catárticos/efeitos adversos , Colonoscopia , Humanos , Polietilenoglicóis/administração & dosagem , Polietilenoglicóis/efeitos adversos , Estudos Prospectivos , Sulfatos/administração & dosagem , Sulfatos/efeitos adversos , Resultado do Tratamento
8.
Plant Cell Rep ; 41(7): 1549-1560, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35562569

RESUMO

KEY MESSAGE: Nuclear-localized Arabidopsis MYB3 functions as a transcriptional repressor for regulation of lignin and anthocyanin biosynthesis under high salt conditions. Salinity stress is a major factor which reduces plant growth and crop yield worldwide. To improve growth of crops in high salinity environments, plant responses to salinity stress must be tightly controlled. Here, to further understand the regulation of plant responses under high salinity conditions, the function of the MYB3 transcription factor was studied as a repressor to control accumulation of lignin and anthocyanin under salt stress conditions. Nuclear-localized MYB3 forms a homodimer. It is ubiquitously expressed, especially in vascular tissues, with expression highly induced by NaCl in tissues such as roots, leaves, stems, and flowers. myb3 mutant plants exhibited longer root growth in high NaCl conditions than wild-type plants. However, several NaCl responsive genes were not significantly altered in myb3 compared to wild-type. Interestingly, high accumulation of lignin and anthocyanin occurred in myb3 under NaCl treatment, as well as increased expression of genes involved in lignin and anthocyanin biosynthesis, such as phenylalanine ammonia lyase 1 (PAL1), cinnamate 4-hydroxylase (C4H), catechol-O-methyltransferase (COMT), 4-coumaric acid-CoA ligase (4CL3), dihydroflavonol reductase (DFR), and leucoanthocyanidin dioxygenase (LDOX). According to yeast two-hybrid screenings, various transcription factors, including anthocyanin regulators Transparent Testa 8 (TT8) and Enhancer of Glabra 3 (EGL3), were isolated as MYB3 interacting proteins. MYB3 was characterized as a transcriptional repressor, with its repressor domain located in the C-terminus. Overall, these results suggest that nuclear-localized MYB3 functions as a transcriptional repressor to control lignin and anthocyanin accumulation under salinity stress conditions.


Assuntos
Proteínas de Arabidopsis , Arabidopsis , Antocianinas/metabolismo , Arabidopsis/genética , Arabidopsis/metabolismo , Proteínas de Arabidopsis/genética , Proteínas de Arabidopsis/metabolismo , Catecol O-Metiltransferase/genética , Catecol O-Metiltransferase/metabolismo , Regulação da Expressão Gênica de Plantas , Lignina/metabolismo , Estresse Salino/genética , Cloreto de Sódio/metabolismo , Cloreto de Sódio/farmacologia , Fatores de Transcrição/genética , Fatores de Transcrição/metabolismo
9.
J Prosthet Dent ; 127(5): 802.e1-802.e10, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35272842

RESUMO

STATEMENT OF PROBLEM: The beam profile of a light polymerization unit shows an inhomogeneous distribution. Therefore, the light passing through indirect restorations may be inhomogeneous and affect the polymerization of the resin cement. PURPOSE: The purpose of this in vitro study was to investigate the effects of the inhomogeneous distribution of irradiance passing through a computer-aided design and computer-aided manufacturing (CAD-CAM) block on the microhardness of resin cement. MATERIAL AND METHODS: IPS e.max CAD (A3 LT, A3 HT), Celtra Duo (A3 LT), LAVA Ultimate (A3 LT), and Vita Enamic (A3 T) blocks were tested and cut into 1.0-, 1.5-, 2.0-, and 4.0-mm thicknesses (N=100). The resin cements were Variolink N base (light-polymerized) and RelyX U200 (dual-polymerized). The light transmission, irradiance, and beam profile of each block were measured. For microhardness measurement, 5 points (-4 mm, -2 mm, 0 mm, +2 mm, and +4 mm) that coincided with the distance from the center to the periphery of the tip were marked on the specimen's surface. At each point, microhardness was measured 24 hours after polymerization. Repeated measured 1-way ANOVA with the LSD test was performed to analyze the effect of measuring points on the microhardness (α=.05). RESULTS: The microhardness of the resin cements decreased with an increase of the CAD-CAM block thickness (P<.05). Resin cements under a 1-mm CAD-CAM block showed relatively uniform microhardness, whereas those under 2-mm and 4-mm blocks showed inhomogeneous microhardness (P<.05). CONCLUSIONS: Inhomogeneous light transmission from a light polymerization unit through CAD-CAM blocks resulted in the nonuniform microhardness of resin cement.


Assuntos
Desenho Assistido por Computador , Cimentos de Resina , Cerâmica , Porcelana Dentária , Teste de Materiais , Polimerização , Cimentos de Resina/uso terapêutico , Propriedades de Superfície
10.
Vet Med (Praha) ; 67(8): 447-453, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-38716189

RESUMO

A ten-year-old indoor, castrated male Cardigan Welsh Corgi (Canis familiaris) presented with the chief complaints of chronic vomiting, retching, hypersalivation, and bilateral submandibular masses for two months. The systemic examinations, including serum chemistry, radiography, ultrasonography, and fluoroscopy, were unremarkable. A fine-needle aspiration revealed bilateral submandibular sialadenitis. Broad-spectrum antibiotics with phenobarbital were prescribed to alleviate the ptyalism. Thereafter, the left submandibular glands were normalised, and the right submandibular glands decreased to half their size. Three weeks later, the animal had an emergency visit because of a sudden left exophthalmos. Computed tomography and magnetic resonance imaging revealed enlarged left zygomatic and right mandibular salivary glands. The affected glands were surgically removed; the histopathologic examination confirmed non-septic sialadenitis, and the patient was finally diagnosed with idiopathic sialadenitis. Vomiting continued after the gland removal and the dog required a gradual increase in the phenobarbital dosage and an additional antiepileptic drug (potassium bromide) to manage the symptoms. The patient died eight months later from an unknown cause. This case report of bilateral submandibular sialadenitis concurrent with unilateral zygomatic sialadenitis in a Welsh Corgi dog suggests that when multiple salivary glands are involved, the response to anti-epileptic drugs and the prognosis is poor compared to that involving a single salivary gland.

11.
Anal Chem ; 93(24): 8638-8646, 2021 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-34110775

RESUMO

In situ wireless monitoring for cell proliferation and detachment kinetics was conducted using pH-responsive zwitterionic polymer dots (Z-PDs), based on changes in electrochemical signals derived from Z-PD-coated substrates via the interaction of charges transferred between Z-PDs and cells. Z-PD-coated substrates were found to be a potent means to monitor and manipulate cell adhesion and detachment because of their high sensitivity over a wide range of pH conditions, and modification of the coated substrates was confirmed using a wireless system. At neutral pH, Z-PD-coated wireless sensors exhibited π-π stacking involving aromatic rings with hydrophobic interactions, thereby promoting cell proliferation; consequently, an increase in the measured resistance was observed. In contrast, Z-PD-coated substrates triggered by acidic and basic conditions promoted cell detachment, which induced an increase in the resistance compared with Z-PD substrates at pH 6.8, as a result of charges transferred to support Z-PD internalization through cell membranes after detachment. Therefore, as a wireless biosensor with excellent pH responsiveness that facilitates cell proliferation and detachment and whose electrochemical signals could be additionally acquired via a smartphone, Z-PD biosensors demonstrated a more favorable approach for monitoring cell-surface interactions than conventional optically based methods.


Assuntos
Polímeros , Proliferação de Células , Condutividade Elétrica , Concentração de Íons de Hidrogênio , Interações Hidrofóbicas e Hidrofílicas
12.
Methods ; 177: 2-14, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31874237

RESUMO

Synthetic nanoparticles are extensively utilized in various biomedical engineering fields because of their unique physicochemical properties. However, their exogenous characteristics result in synthetic nanosystem invaders that easily induce the passive immune clearance mechanism, thereby increasing the retention effect caused by reticuloendothelial system (RES), resulting in low therapeutic efficacy and toxic effects. Recently, a cell membrane cloaking has been emerging technique as a novel interfacing approach from the biological/immunological perspective. This has been considered as useful technique for improving the performance of synthetic nanocarriers in vivo. By cell membrane cloaking, nanoparticles acquire the biological functions of natural cell membranes due to the presence of membrane-anchored proteins, antigens, and immunological moieties as well as physicochemical property of natural cell membrane. Due to cell membrane cloaking, the derived biological properties and functions of nanoparticles such as their immunosuppressive capability, long circulation time, and disease targeting ability have enhanced their future potential in biomedicine. Here, we review the cell membrane-cloaked nanosystems, highlight their novelty, introduce the preparation and characterization methods with relevant biomedical applications, and describe the prospects for using this novel biomimetic system that was developed from a combination of cell membranes and synthetic nanomaterials.


Assuntos
Aterosclerose/terapia , Membrana Celular/química , Sistemas de Liberação de Medicamentos/métodos , Isquemia/terapia , Nanopartículas/uso terapêutico , Neoplasias/terapia , Animais , Aterosclerose/metabolismo , Aterosclerose/patologia , Plaquetas/química , Plaquetas/metabolismo , Membrana Celular/metabolismo , Modelos Animais de Doenças , Eritrócitos/química , Eritrócitos/metabolismo , Humanos , Isquemia/metabolismo , Isquemia/patologia , Extração Líquido-Líquido/métodos , Camundongos , Mimetismo Molecular , Nanopartículas/química , Nanopartículas/metabolismo , Neoplasias/metabolismo , Neoplasias/patologia , Copolímero de Ácido Poliláctico e Ácido Poliglicólico/química , Sonicação/métodos , Células-Tronco/química , Células-Tronco/metabolismo , Linfócitos T/química , Linfócitos T/metabolismo
13.
Clin Infect Dis ; 71(16): 2236-2239, 2020 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-32297925

RESUMO

We report changes in viral load over time in a 27-day-old neonate with coronavirus disease 2019 who presented with fever, cough, and vomiting. Severe acute respiratory syndrome coronavirus 2 RNA was detected in the nasopharynx, oropharynx, stool, saliva, plasma, and urine. The highest viral RNA copies in nasopharynx decreased over time while viral load in stool remained high.


Assuntos
COVID-19/diagnóstico , Mães , RNA Viral/análise , Carga Viral , Líquidos Corporais/virologia , COVID-19/sangue , COVID-19/urina , Fezes/virologia , Feminino , Humanos , Recém-Nascido , Coreia (Geográfico) , Nasofaringe/virologia , SARS-CoV-2 , Saliva/virologia
14.
BMC Genomics ; 21(1): 417, 2020 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-32571211

RESUMO

BACKGROUND: Multipotent mesenchymal stromal cells (MSCs) can be isolated from numerous tissues and are attractive candidates for therapeutic clinical applications due to their immunomodulatory and pro-regenerative capacity. Although the minimum criteria for defining MSCs have been defined, their characteristics are known to vary depending on their tissue of origin. RESULTS: We isolated and characterized human MSCs from three different bones (ilium (I-MSCs), maxilla (Mx-MSCs) and mandible (Md-MSCs)) and proceeded with next generation RNA-sequencing. Furthermore, to investigate the gene expression profiles among other cell types, we obtained RNA-seq data of human embryonic stem cells (ESCs) and several types of MSCs (periodontal ligament-derived MSCs, bone marrow-derived MSCs, and ESCs-derived MSCs) from the Sequence Reads Archive and analyzed the transcriptome profile. We found that MSCs derived from tissues of the maxillofacial region, such as the jaw bone and periodontal ligament, were HOX-negative, while those derived from other tissues were HOX-positive. We also identified that MSX1, LHX8, and BARX1, an essential regulator of craniofacial development, were strongly expressed in maxillofacial tissue-derived MSCs. Although MSCs may be divided into two distinct groups, the cells originated from over the neck or not, on the basis of differences in gene expression profile, the expression patterns of all CD antigen genes were similar among different type of MSCs, except for ESCs. CONCLUSIONS: Our findings suggest that MSCs from different anatomical locations, despite meeting general characterization criteria, have remarkable differences in gene expression and positional memory. Although stromal cells from different anatomical sources are generally categorized as MSCs, their differentiation potential and biological functions vary. We suggested that MSCs may retain an original tissue memory about the developmental process, including gene expression profiles. This could have an important impact when choosing an appropriate cell source for regenerative therapy using MSCs.


Assuntos
Perfilação da Expressão Gênica/métodos , Redes Reguladoras de Genes , Ílio/citologia , Mandíbula/citologia , Maxila/citologia , Diferenciação Celular , Proliferação de Células , Células Cultivadas , Regulação da Expressão Gênica , Sequenciamento de Nucleotídeos em Larga Escala , Proteínas de Homeodomínio/genética , Humanos , Ílio/química , Mandíbula/química , Maxila/química , Células-Tronco Mesenquimais/química , Células-Tronco Mesenquimais/citologia , Especificidade de Órgãos , Análise de Sequência de RNA/métodos , Sequenciamento do Exoma
15.
Emerg Infect Dis ; 26(10): 2497-2499, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32497001

RESUMO

Along with positive SARS-CoV-2 RNA in nasopharyngeal swabs, viral RNA was detectable at high concentration for >3 weeks in fecal samples from 12 mildly symptomatic and asymptomatic children with COVID-19 in Seoul, South Korea. Saliva also tested positive during the early phase of infection. If proven infectious, feces and saliva could serve as transmission sources.


Assuntos
Betacoronavirus/isolamento & purificação , Infecções por Coronavirus/virologia , Fezes/virologia , Nasofaringe/virologia , Pneumonia Viral/virologia , RNA Viral/análise , Saliva/virologia , Adolescente , Infecções Assintomáticas , COVID-19 , Criança , Pré-Escolar , Infecções por Coronavirus/transmissão , Infecções por Coronavirus/urina , Humanos , Lactente , Recém-Nascido , Pandemias , Plasma/virologia , Pneumonia Viral/transmissão , Pneumonia Viral/urina , República da Coreia , SARS-CoV-2 , Urina/virologia , Carga Viral
16.
Clin Oral Implants Res ; 31(7): 585-594, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32125718

RESUMO

OBJECTIVES: Conventional guided bone regeneration (GBR) limits the amount of bone graft due to limited soft tissue expansion. We hypothesize that the use of tissue expander will successfully augment soft tissue prior to bone graft, allowing for sufficient amount of grafting which will lead to a more stable and effective vertical bone graft. The authors aimed to evaluate effectiveness of the novel self-inflating tissue expander for vertical augmentation in terms of soft tissue expansion, clinical outcomes, and related complications. MATERIAL AND METHODS: A prospective, multicenter, randomized controlled trial was performed on patients requiring vertical augmentation. For experimental group patients, the tissue expander was subperiosteally implanted and followed by a tunneling bone graft without full flap reflection. Control patients underwent conventional vertical GBR. Primary objectives were to evaluate the dimensional changes of soft tissue and radiographic vertical bone gain and retention. As a secondary outcome, clinical complications and thickness changes of expanded overlying tissue were assessed and analyzed. RESULTS: Twenty-three patients in each group were included. During a 4-week expansion, two of the experimental group showed over-expansion and one showed mucosal perforation associated with previous severe scars. The other patients showed uneventful expansion and mean tissue augmentation was 6.88 ± 1.64 mm vertically. Ultrasonographic measurements of overlying gingiva revealed no thinning after tissue expansion (p > .05). Significantly higher vertical bone gain was shown in the experimental group (5.12 ± 1.25 mm) compared with that in the control patients (4.22 ± 1.15 mm; p < .05). After a 6-month retention period, the mean vertical bone measurement of the controls had decreased to 1.90 mm (55.0% reduction), which was a significantly greater decrease than that in the experimental group (mean 3.55 mm, 30.7% reduction; p < .05). CONCLUSION: Our results demonstrated the effectiveness of tissue expanders followed by tunneling bone graft for vertical augmentation; however, studies comparing the two techniques without tissue expanders are needed to elucidate the net effect of tissue expansion.


Assuntos
Aumento do Rebordo Alveolar , Dispositivos para Expansão de Tecidos , Processo Alveolar , Regeneração Óssea , Transplante Ósseo , Implantação Dentária Endóssea , Humanos , Estudos Prospectivos , Expansão de Tecido
17.
Sensors (Basel) ; 20(22)2020 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-33218017

RESUMO

For wearable health monitoring systems and soft robotics, stretchable/flexible pressure sensors have continuously drawn attention owing to a wide range of potential applications such as the detection of human physiological and activity signals, and electronic skin (e-skin). Here, we demonstrated a highly stretchable pressure sensor using silver nanowires (AgNWs) and photo-patternable polyurethane acrylate (PUA). In particular, the characteristics of the pressure sensors could be moderately controlled through a micro-patterned hole structure in the PUA spacer and size-designs of the patterned hole area. With the structural-tuning strategies, adequate control of the site-specific sensitivity in the range of 47~83 kPa-1 and in the sensing range from 0.1 to 20 kPa was achieved. Moreover, stacked AgNW/PUA/AgNW (APA) structural designed pressure sensors with mixed hole sizes of 10/200 µm and spacer thickness of 800 µm exhibited high sensitivity (~171.5 kPa-1) in the pressure sensing range of 0~20 kPa, fast response (100~110 ms), and high stretchability (40%). From the results, we envision that the effective structural-tuning strategy capable of controlling the sensing properties of the APA pressure sensor would be employed in a large-area stretchable pressure sensor system, which needs site-specific sensing properties, providing monolithic implementation by simply arranging appropriate micro-patterned hole architectures.


Assuntos
Monitorização Fisiológica/instrumentação , Nanofios , Poliuretanos , Dispositivos Eletrônicos Vestíveis , Humanos , Pressão , Prata
18.
J Autoimmun ; 100: 114-119, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30922727

RESUMO

Despite advances in the understanding of the pathogenesis, disease-specific biomarkers have not been included in the classification criteria for Primary Sjogren's syndrome (pSS). Based on a microarray of peripheral blood mononuclear cells (PBMCs) from patients with primary Sjogren's syndrome (pSS), we aimed to investigate whether soluble sialic acid-binding immunoglobulin-like lectin (siglec)-5 in saliva might be a biomarker for pSS. The concentration of siglec-5 in saliva and sera was determined by ELISA. Clinical parameters related with pSS were obtained from pSS registry and correlation with salivary siglec-5 level was evaluated. Receiver operating curve (ROC) analysis was performed to determine cut off value. A separate validation cohort consisted of subjects with suspicious pSS was evaluated to determine the performance. The level of salivary siglec-5 was significantly higher in pSS patients (n = 170) compared with HCs (n = 25), non SS sicca patients (n = 78) or patients with systemic lupus erythematosus (SLE) (n = 43) (1346.8 [202.8-4280.0] pg/mL, 6.08 [0-134.0] pg/mL, 195 [0-947.5] pg/mL, and 0 [0-238.7] pg/mL, median [interquartile range], P < 0.001). Salivary siglec-5 level negatively correlated with salivary flow rate (spearman's rho: -0.420, P < 0.001), and positively correlated with ocular surface score (rho: 0.331, P < 0.001) and serum immunoglobulin G level (rho = 0.202, P = 0.008). In ROC analysis, area under the curve was 0.774[0.724-0.826]. With a cut off value of 400 pg/mL, sensitivity and specificity was 0.69 and 0.70 respectively. In validation cohort (45 pSS patients and 45 non SS sicca patients), sensitivity and specificity of siglec-5 was 64.4% and 77.8%, respectively. In conclusion, the level of soluble siglec-5 is significantly higher in the saliva from pSS patients, which reflects the severity of hyposalivation and ocular surface damage. This novel salivary biomarker may provide benefits for pSS diagnosis.


Assuntos
Antígenos CD/imunologia , Antígenos de Diferenciação Mielomonocítica/imunologia , Lectinas/imunologia , Saliva/imunologia , Adulto , Biomarcadores , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Síndrome de Sjogren/diagnóstico , Síndrome de Sjogren/imunologia , Síndrome de Sjogren/patologia
19.
Clin Exp Rheumatol ; 37 Suppl 118(3): 107-113, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31376264

RESUMO

OBJECTIVES: To investigate clinical characteristics of patients with primary Sjögren's syndrome (SS) who were negative for anti-Ro/SSA antibody but positive for minor salivary gland biopsy (MSGB) compared to patients who presented positivity for anti-Ro/SSA antibody. METHODS: The data of 355 patients from the Korean Initiative of primary Sjögren's Syndrome (KISS), a nationwide prospective cohort for primary SS in Korea, were analysed. All patients fulfilled the 2016 American College of Rheumatology/European League Against Rheumatism (EULAR) classification criteria. Of these patients, 326 were positive for anti-Ro/SSA antibody and 29 were antibody-negative, although they had positive findings in MSGB. Various clinical features including all kinds of tests for evaluating secretory function, disease-related clinical indices and serological values available in the cohort were compared between the two groups. RESULTS: The anti-Ro/SSA-negative group showed less rheumatoid factor positivity (p<0.001), leucopenia (p=0.003), hyper-gammaglobulinaemia (p<0.001), lower serum ß2-microglobulin level (p=0.034), more anti-centromere antibody positivity (p<0.001), higher score in dryness domain of EULAR SS patient-reported index (p=0.048) and more positivity for peripheral nervous system domain in EULAR SS disease activity index and loss of teeth in SS disease damage index (p=0.021 and 0.041, respectively) than patients who were positive for anti-Ro/ SSA antibody. CONCLUSIONS: Primary SS patients who are negative for anti-Ro/SSA antibody have different clinical characteristics compared to patients who are positive for such antibody in Korea. Therefore, clinicians should consider MSGB in patients with suspicious symptoms who are anti-Ro/SSA-negative.


Assuntos
Anticorpos Antinucleares/imunologia , Glândulas Salivares Menores/imunologia , Síndrome de Sjogren , Humanos , Estudos Prospectivos , República da Coreia , Fator Reumatoide , Glândulas Salivares Menores/patologia , Síndrome de Sjogren/diagnóstico , Síndrome de Sjogren/imunologia , Síndrome de Sjogren/patologia
20.
Nanotechnology ; 30(33): 335203, 2019 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-31026860

RESUMO

For the potential switching bio-memory device application using DNA composite thin film, we fabricated and characterized the transparent and biocompatible resistive switching random access memory (RRAM) device within the structure stacking of Pt/Cu2+ doped salmon DNA/FTO, where Cu2+ doping into salmon DNA was solution-processed. The device shows good bipolar switching characteristics with SET and RESET processes at negative and positive sweeps, respectively, with switching memory window greater than 103 ratios. The device was observed to be in low resistance state as its pristine state and an initial RESET state was necessary to achieve programmable SET and RESET cycles. Based on the electrical characteristics of the Cu2+-doped salmon DNA-based RRAM device we propose a switching mechanism with the formation and rupture of conductive filaments due to the migration of Cu2+ during the electrical stress. Our understanding could contribute to the engineering of biomaterial memory switching medium for the environmentally benign, biocompatible and biodegradable memory storage devices.


Assuntos
Materiais Biocompatíveis/química , Cobre/química , DNA/química , Animais , Cátions Bivalentes/química , Impedância Elétrica , Eletrodos , Desenho de Equipamento , Luz , Nanoestruturas/química , Nanotecnologia/instrumentação , Platina/química , Salmão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA