Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Endovasc Ther ; 27(6): 936-945, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32873131

RESUMO

PURPOSE: To report the outcomes after treating stenotic or occluded femoropopliteal lesions with a drug-coated balloon (DCB) followed by the implantation of a thin-strut self-expanding bare metal stent in the BIOLUX 4EVER trial (ClinicalTrials.gov identifier NCT02211664). MATERIALS AND METHODS: The prospective, multicenter, physician-initiated BIOLUX 4-EVER trial was conducted at 5 centers in Belgium and enrolled 120 patients (mean age 70.9±10.5 years; 79 men) with symptomatic stenotic or occluded de novo femoropopliteal lesions. A fifth of the patients had diabetes mellitus and nearly half had previous peripheral artery interventions. The lesions were a mean 83.3±49.5 mm long with a mean reference vessel diameter of 5.26±0.59 mm. Lesions were treated with a Passeo-18 Lux DCB followed by the implantation of a Pulsar-18 bare metal stent. Follow-up visits were conducted at 1, 6, 12, and 24 months postprocedure; the main outcome was primary patency at 12 months. RESULTS: Technical success was obtained in all patients. Primary patency was observed in 89.9% of patients (95% CI 84.0% to 95.8%) at 12 months and in 83.5% at 24 months (95% CI 89.9% to 97.3%), and freedom from target lesion revascularization was 93.6% (95% CI 89.9% to 97.3%) and 86.1% (95% CI 79.9% to 92.3%), respectively. Ten patients died throughout the course of the trial (90.7% survival at 24 months), all of noncardiovascular causes. The ankle-brachial index improved from 0.68±0.09 at baseline to 0.93±0.11 and 0.93±0.12 at 12- and 24-month follow-up visits (p<0.001). An improvement of at least 1 Rutherford category was observed in 91 of 94 patients (96.8%) at 12 months and 78 of 83 patients (93.4%) at 24 months (p<0.001). CONCLUSION: The combination of a Passeo-18 Lux DCB followed by a Pulsar-18 stent implantation produced safe and effective outcomes in the treatment of femoropopliteal lesions at up to 24 months. Adding paclitaxel to the bare nitinol stent platform by predilating with a Passeo-18 Lux DCB seems to increase efficacy at 1 and 2 years compared with the use of bare metal stents only, which were investigated in the precursor 4-EVER study.


Assuntos
Angioplastia com Balão , Artéria Femoral/cirurgia , Doença Arterial Periférica , Preparações Farmacêuticas , Stents , Idoso , Idoso de 80 Anos ou mais , Ligas , Angioplastia com Balão/efeitos adversos , Bélgica , Materiais Revestidos Biocompatíveis , Feminino , Artéria Femoral/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/uso terapêutico , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/cirurgia , Artéria Poplítea/diagnóstico por imagem , Estudos Prospectivos , Resultado do Tratamento , Grau de Desobstrução Vascular
2.
Catheter Cardiovasc Interv ; 91(3): 497-504, 2018 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-29086462

RESUMO

OBJECTIVES: The purpose of this study was to assess the safety and performance of Stellarex Drug-coated balloon (DCB). BACKGROUND: DCB coatings differ in excipients, paclitaxel dose, and coating morphologies. Due to these differences, a class effect with DCBs has not been demonstrated. Consequently, each DCB needs to be evaluated independently based on its own clinical study results. METHODS: The ILLUMENATE Global Study is a prospective, multicenter, single-arm study. Patients with intermittent claudication or ischemic rest pain due to superficial femoral artery (SFA) and/or popliteal peripheral artery disease (PAD) were treated with the Stellarex DCB. The primary efficacy endpoint was primary patency, defined as freedom from restenosis with peak systolic velocity ratio ≤2.5 or clinically-driven target lesion revascularization (CD-TLR) at 12 months. The primary safety endpoint was freedom from device and procedure-related death through 30 days postprocedure and freedom from target limb major amputation and CD-TLR through 12 months. RESULTS: In total, 417 lesions were treated in 371 patients. The mean lesion length was 7.5 ± 5.3 cm, 40.8% of lesions were severely calcified per core laboratory fluoroscopy criteria and 31.3% were total occlusions. Primary patency by independent duplex core lab evaluation was 81.4% and the freedom from CD-TLR was 94.8% day 365 per Kaplan-Meier estimate. The majority of patients experienced improvements in their Rutherford classification (90.3%) and walking impairment questionnaire score (83.6%) at 12 months compared to baseline. CONCLUSIONS: This study validated previous positive findings and confirms the strong safety profile and effectiveness outcomes.


Assuntos
Angioplastia com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Artéria Femoral , Paclitaxel/administração & dosagem , Doença Arterial Periférica/terapia , Artéria Poplítea , Dispositivos de Acesso Vascular , Idoso , Angioplastia com Balão/efeitos adversos , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Fluxo Sanguíneo Regional , Fatores de Tempo , Resultado do Tratamento
3.
Ann Vasc Surg ; 51: 37-47, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29678649

RESUMO

BACKGROUND: The DURABILITY Iliac clinical study evaluated the safety and effectiveness of 2 nitinol self-expanding stents for the treatment of atherosclerotic common and external iliac artery lesions up to 10 cm in length and >50% stenosis in subjects with Rutherford classification peripheral arterial disease stages 2-4. METHODS: DURABILITY Iliac was a prospective, multicenter, core lab adjudicated, nonrandomized clinical study enrolling 75 subjects from 15 sites in the United States and Europe. Clinical follow-up visits were at 30 days, 9 months, and 1, 2, and 3 years after procedure. The primary outcome measured was the major adverse event (MAE) rate at 9 months, defined as a composite of periprocedural death, in-hospital myocardial infarction (MI), clinically driven target lesion revascularization (CD-TLR), and amputation of the treated limb through 9 months after procedure. Secondary outcomes included primary patency rate at 9 months, clinically driven target vessel revascularization (CD-TVR), change in ankle-brachial index, and change in Walking Impairment Questionnaire score at 30 days and 9 months. Device success was defined as the ability to deploy the stent as intended at the treatment site. RESULTS: The MAE rate at 9 months was 1.3% (1/75), with 1 subject experiencing a CD-TLR. No periprocedural deaths, MIs, or amputations were reported. Primacy patency at 9 months was 95.8%. Freedom from CD-TVR was 98.6% at 9 months. Subjects improved in Walking Impairment Questionnaire scores for all categories (walking impairment, walking speed, walking distance, and stair climbing) at the 30-day and 9-month visit. Device success was 100%. CONCLUSIONS: The 9-month results of the DURABILITY Iliac study demonstrate the safety and effectiveness of 2 nitinol self-expanding stents for the treatment of atherosclerotic lesions of the common and external iliac arteries.


Assuntos
Procedimentos Endovasculares/instrumentação , Artéria Ilíaca , Doença Arterial Periférica/terapia , Stents Metálicos Autoexpansíveis , Idoso , Ligas , Índice Tornozelo-Braço , Constrição Patológica , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Europa (Continente) , Tolerância ao Exercício , Feminino , Mortalidade Hospitalar , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/fisiopatologia , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/mortalidade , Doença Arterial Periférica/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Fatores de Risco , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Grau de Desobstrução Vascular , Caminhada
4.
J Endovasc Ther ; 24(3): 311-316, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28351310

RESUMO

PURPOSE: To investigate the efficacy of the paclitaxel-coated, self-expanding, nitinol Stentys Stent System in tibioperoneal lesions ≤50 mm long. METHODS: The prospective, single-arm, multicenter PES-BTK-70 trial ( ClinicalTrials.gov identifier NCT01630070) evaluated the safety and efficacy of the coronary Stentys Stent System in the treatment of a stenotic or occlusive lesion ≤50 mm long in the tibioperoneal arteries of patients with critical limb ischemia (CLI). Between January 2012 and May 2013, 70 patients (mean age 74.6±9.4 years; 45 men) with CLI [Rutherford category 4 (37, 52.9%) or 5 (33, 47.1%)] received a Stentys drug-eluting stent for the treatment of infrapopliteal stenosis (60, 85.7%) or occlusion (10, 14.3%). The mean lesion length was 17.2 mm (4.0-58.5). The primary outcome measures were primary patency at 6 months (duplex ultrasound) and 12 months (angiography). Secondary outcomes included limb salvage and freedom from target lesion revascularization (TLR). Kaplan-Meier estimates of the outcomes are given with the 95% confidence intervals (CI). RESULTS: Technical and procedure success (<30% residual stenosis without major complications) was achieved in 68 (97.1%) of 70 cases. Primary patency was 87.6% (95% CI 83.5% to 91.7%) at 6 months and 72.6% (95% CI 66.9% to 78.3%) at 1 year. Freedom from TLR was 79.1% at 1 year (95% CI 73.9% to 84.3) and limb salvage was 98.5% (95% CI 97.0 to 100.0). No stent fractures were found by core laboratory review of all follow-up imaging data available up to 12 months. CONCLUSION: In this study, the self-expanding, nitinol, paclitaxel-eluting, coronary Stentys stent was found to be safe and effective in the below-the-knee region, with results similar to the most recent limus-eluting stent trials.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Stents Farmacológicos , Procedimentos Endovasculares/instrumentação , Isquemia/terapia , Paclitaxel/administração & dosagem , Doença Arterial Periférica/terapia , Artéria Poplítea , Stents Metálicos Autoexpansíveis , Idoso , Idoso de 80 Anos ou mais , Ligas , Angiografia , Bélgica , Fármacos Cardiovasculares/efeitos adversos , Constrição Patológica , Estado Terminal , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Isquemia/diagnóstico por imagem , Isquemia/fisiopatologia , Estimativa de Kaplan-Meier , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
5.
J Endovasc Ther ; 22(1): 1-10, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25775672

RESUMO

PURPOSE: To evaluate the short- and midterm outcomes of the Viabahn endoprosthesis with Propaten Bioactive Surface vs. standard balloon angioplasty for treatment of in-stent restenosis in the superficial femoral artery. METHODS: Between June 2010 and February 2012, 83 patients with superficial femoral artery in-stent and Rutherford category 2 to 5 ischemia were enrolled at 7 sites participating in this prospective randomized controlled study (RELINE; ClinicalTrials.gov; identifier NCT01108861). The patients were randomized to treatment with either the heparin-bonded Viabahn endoprosthesis (n = 39: 29 men; mean age 67.7 ± 9.8 years) or a standard angioplasty balloon (n = 44: 32 men; mean age 69.0 ± 9.7 years). The primary effectiveness outcome was primary patency at 12 months, defined as no restenosis/occlusion within the target lesion based on duplex ultrasound and no target lesion revascularization. The primary safety endpoint was the incidence of serious device-related adverse events within 30 days of the procedure. RESULTS: All patients randomized to receive dilation or the Viabahn stent-graft were treated according to their assignment. The technical success was 100% for the Viabahn group and 81.8% for the angioplasty group (p = 0.002) owing to 9 patients requiring a bailout procedure after unsuccessful angioplasty. The 12-month primary patency rates were 74.8% for the Viabahn group and 28.0% for the angioplasty group (p < 0.001). Excluding the 9 angioplasty patients who received bailout stenting, the primary patency for optimal balloon angioplasty was 37.0% (p < 0.001). Three patients experienced device-related adverse events within 30 days: occlusion of the target lesion (Viabahn group), peripheral embolization (angioplasty group), and reocclusion of the target lesion (angioplasty group). CONCLUSION: In this study, the treatment of femoropopliteal in-stent restenosis with a Viabahn endoprosthesis showed significantly better results than treatment with a standard balloon at 1 year.


Assuntos
Angioplastia com Balão , Stents Farmacológicos , Artéria Femoral , Doença Arterial Periférica/terapia , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/métodos , Bélgica , Materiais Revestidos Biocompatíveis , Constrição Patológica , Feminino , Seguimentos , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/patologia , Estudos Prospectivos , Recidiva , Método Simples-Cego , Stents/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
6.
J Endovasc Ther ; 21(6): 765-74, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25453876

RESUMO

Purpose: To confirm the performance and safety of the 25-cm Viabahn endoprosthesis with Propaten bioactive surface when used in the treatment of de novo and/or restenotic TransAtlantic Inter-Society Consensus II C and D lesions of the superficial femoral artery and proximal popliteal artery. Methods: The 25-cm Gore Viabahn Endoprosthesis study (ClinicalTrials.gov identifier NCT01263665) is a prospective, multicenter, single-arm study that enrolled 71 patients (50 men; mean age 66.7 ± 8.34 years) with lifestyle-limiting claudication (Rutherford class 2 to 4) and lesions longer than 20 cm (mean length 26.5 ± 5.31 cm, range 20-40). The majority of lesions (92.9%) were total occlusions. The primary performance outcome was post-deployment stent length within ± 10% of the pre-deployment stent length determined angiographically by quantitative vascular analysis. The primary safety outcome was device- and procedure-related serious adverse events occurring within 30 days of the procedure. The patients underwent follow-up examinations at 1 month and 1 year. Results : The median follow-up was 12.3 months (mean 12.3 ± 0.6). Nine (12.7%) patients discontinued the study due to different reasons including 2 bypass surgeries. Angiography was available in 60 patients to determine the primary performance outcome, which was met in all cases. Two (2.8%) patients experienced a procedure-/device-related adverse event (dissection) during the 30-day follow-up. Kaplan-Meier estimates for 1-year primary and secondary patency were 67.0% [95% confidence interval (CI) 53.5% to 77.3%] and 96.9% (95% CI 88.0% to 99.2%), respectively. Changes in ankle-brachial index and Rutherford category at 1 and 12 months each showed sustained improvement. Conclusion : This study confirms that the 25-cm Viabahn endoprosthesis acutely performs as intended and is safe when used as indicated in complex femoropopliteal lesions. One-year primary and secondary patency rates are satisfying and comparable to historical prosthetic bypass graft outcomes.


Assuntos
Anticoagulantes/administração & dosagem , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Materiais Revestidos Biocompatíveis , Procedimentos Endovasculares/instrumentação , Artéria Femoral/cirurgia , Heparina/administração & dosagem , Doença Arterial Periférica/cirurgia , Artéria Poplítea/cirurgia , Stents , Idoso , Índice Tornozelo-Braço , Implante de Prótese Vascular/efeitos adversos , Constrição Patológica , Procedimentos Endovasculares/efeitos adversos , Europa (Continente) , Feminino , Artéria Femoral/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/fisiopatologia , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
7.
J Endovasc Ther ; 20(6): 746-56, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24325689

RESUMO

PURPOSE: To report the 1-year results of a prospective multicenter trial to evaluate the safety and efficacy of treating symptomatic femoropopliteal occlusive disease using 4-F-compatible materials and no closure device. METHODS: The non-randomized 4-EVER trial (4-F endovascular treatment approach to infrainguinal disease) was conducted at 5 European hospitals (ClinicalTrials.gov identifier NCT01413139). The protocol mandated the use of only 4-F sheaths, self-expanding nitinol stents (Astron Pulsar or Pulsar-18 stent), and balloons from a single manufacturer. Between June 2010 and June 2011, 120 symptomatic patients (82 men; mean age 71±9.7 years, range 47-90), primarily claudicants, treated for 120 femoropopliteal lesions (>90% TASC A/B) were enrolled. The mean lesion length was 71.0±45.9 mm. Follow-up evaluations were scheduled on day 1 and at 1, 6, 12, and 24 months. A duplex ultrasound was performed on all follow-up visits to determine vessel patency (primary outcome measure at 1 year), and biplanar radiography was performed at 12 and 24 months to assess stent fracture. RESULTS: Stents were successfully implanted in all patients: an Astron Pulsar stent in 70 (58.3%) lesions and a Pulsar-18 stent in 46 (38.3%); 4 (3.3%) patients had both stents implanted for flow-limiting dissection after predilation. No closure devices were used; the mean manual compression time was 8.1 minutes (2-15). Four (3.3%) patients developed significant hematoma at the puncture site, but none required surgical repair. The overall 12-month primary patency rate was 81.4%: 85.2% for the Astron Pulsar and 73.4% for the Pulsar-18 (p=0.236). Freedom from target lesion revascularization at 12 months for the entire cohort was 89.3%. CONCLUSION: Compared to published historical data for superficial femoral artery type A/B lesion stenting using 6-F devices, the 4-F devices applied in this trial showed similar patency at 12 months, fewer access site complications, and shorter manual compression times, supporting the supposition that 4-F endovascular treatment is safe and effective.


Assuntos
Angioplastia com Balão/instrumentação , Artéria Femoral , Doença Arterial Periférica/terapia , Artéria Poplítea , Dispositivos de Acesso Vascular , Idoso , Idoso de 80 Anos ou mais , Ligas , Angioplastia com Balão/efeitos adversos , Bélgica , Desenho de Equipamento , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Radiografia , Stents , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Dupla , Grau de Desobstrução Vascular
8.
J Vasc Surg ; 54(4): 1042-50, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21636239

RESUMO

OBJECTIVES: This study investigated the results with primary stenting using the Protégé EverFlex 200-mm-long self-expanding nitinol stent (ev3 Endovascular Inc, Plymouth, Minn) in femoropopliteal TransAtlantic Inter-Society Consensus (TASC) C and D lesions of at least 150 mm in length. METHODS: Between March 2008 and June 2009, 100 patients (66 men) presenting with 100 symptomatic TASC C and D femoropopliteal lesions were treated with at least one 200-mm-long Protégé EverFlex stent. The intention of this study was to treat all lesions with as few stents as possible. The primary study end point was primary patency at 12 months, defined as the absence of hemodynamically significant stenosis on duplex ultrasound imaging (systolic velocity ratio <2.4) at the target lesion and without target lesion revascularization (TLR) ≤12 months. Stent fracture occurrence was assessed at the 12-month follow-up by conventional x-ray imaging. RESULTS: Average patient age was 70 years. Preoperative symptom assessment reported 71 patients (71%) had claudication vs 29 (29%) with critical limb ischemia. Average lesion length was 242 mm (range, 160-450 mm), and 27 patients (27%) presented with popliteal involvement. A total of 158 Protégé EverFlex stents were used to treat 100 lesions. Kaplan-Meier estimation reported a 12-month freedom from target lesion revascularization of 68.2% and a primary patency rate of 64.8%. Stent fractures occurred in six patients (6.0%) when x-ray images taken immediately after the procedure were compared with those taken after 1 year. CONCLUSIONS: The results of our Durability-200 study show an acceptable primary patency rate after 1 year was obtained in this patient cohort with TASC C and D femoropopliteal lesions.


Assuntos
Ligas , Angioplastia com Balão/instrumentação , Arteriopatias Oclusivas/terapia , Artéria Femoral , Artéria Poplítea , Stents , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/efeitos adversos , Índice Tornozelo-Braço , Arteriopatias Oclusivas/diagnóstico , Arteriopatias Oclusivas/fisiopatologia , Bélgica , Constrição Patológica , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Dupla , Grau de Desobstrução Vascular
9.
J Endovasc Ther ; 16(3): 261-9, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19642788

RESUMO

PURPOSE: To evaluate the long-term efficacy and integrity of the PROTEGE EverFlex stent in superficial femoral artery (SFA) lesions in symptomatic patients with peripheral artery disease (PAD). METHODS: A prospective, multicenter, nonrandomized study enrolled 151 subjects (111 men; mean age 67.8 years, range 42-93) undergoing percutaneous treatment of de novo, restenotic, or reoccluded SFA lesions between August 11, 2006, and June 26, 2007. Subjects were scheduled to receive a single stent and be evaluated through 12 months following the implant procedure. Occlusions were present in 40% of the patients. Mean lesion length was 96.4 mm (range 10-150). RESULTS: A total of 161 stents (158 EverFlex) were implanted in the 151 patients: single stents in 93.4% (141/151) and a second stent in 6.6% (10/151). One-year follow-up information was available for 88.7% (134/151) of the study participants; of the remaining 17 subjects, 6 subjects withdrew from the study, 2 were lost to follow-up, and 9 died. Freedom from restenosis data were available for 99.3% (133/134) of the subjects who completed a 12-month follow-up visit. The mean Rutherford classification fell from 2.8+/-0.8 (range 1-5) at baseline to 0.6+/-1.1 (range 0-5) at 12 months. The mean ankle-brachial index rose from 0.6+/-0.2 (range 0-1.4) at baseline to 0.9+/-0.2 (range 0-1.2) at 12 months. The rates for freedom from >50% restenosis at 6 and 12 months were 91.3% (95% CI 84.9% to 95.2%) and 72.2% (95% CI 63.8% to 79.6%), respectively. The freedom from target lesion revascularization rate at 12 months was 79.1% (95% CI 71.2% to 85.6%). The 1-year stent fracture rate was 8.1% (95% CI 4.0% to 14.4%). CONCLUSION: The high freedom from >50% restenosis and low fracture rate at 12 months suggests that the PROTEGE EverFlex stent offers a safe and acceptably efficacious means of treating SFA lesions in symptomatic subjects with PAD.


Assuntos
Ligas , Angioplastia com Balão , Aterosclerose/terapia , Artéria Femoral , Doenças Vasculares Periféricas/terapia , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Seguimentos , Oclusão de Enxerto Vascular/epidemiologia , Oclusão de Enxerto Vascular/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
10.
J Am Coll Cardiol ; 73(6): 667-679, 2019 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-30765033

RESUMO

BACKGROUND: Randomized trials of drug-eluting stents (DES) and drug-coated balloons (DCB) for femoropopliteal interventions reported superior patency rates for both strategies compared to standard balloon angioplasty. To date, head-to-head comparisons are missing. OBJECTIVES: The authors sought to compare DES versus DCB for femoropopliteal lesions through 36 months. METHODS: Within a multicenter, randomized trial, 150 patients with symptomatic femoropopliteal disease were randomly assigned to primary DES implantation or DCB angioplasty with bailout stenting after stratification for lesion length (≤10 cm, >10 cm to ≤20 cm, and >20 cm to ≤30 cm). The primary effectiveness endpoint was primary patency at 12 months assessed by Kaplan-Meier. Secondary endpoints comprised major adverse events including death, major amputations, and clinically driven target lesion revascularization, and clinical outcomes. RESULTS: More than one-half of lesions were total occlusions, and the stenting rate was 25.3% in the DCB group. Kaplan-Meier estimates of primary patency were 79% and 80% for DES and DCB at 12 months (p = 0.96) but decreased to 54% and 38% through 36 months (p = 0.17), respectively. Freedom from clinically driven target lesion revascularization was >90% at 12 months but dropped to around 70% at 36 months in both groups. Overall, the mortality rate through 36 months was 7.3%, with 1 procedure-related death in the DCB group. Improvement of clinical outcomes was sustained through 36 months. CONCLUSIONS: Patency rates at 12 months suggest comparable effectiveness and safety of DES versus DCB plus bailout stenting in femoropopliteal interventions; a trend in favor of the DES was observed up to 36 months. (Randomized Evaluation of the Zilver PTX Stent vs. Paclitaxel-Eluting Balloons for Treatment of Symptomatic Peripheral Artery Disease of the Femoropopliteal Artery [REAL PTX]; NCT01728441).


Assuntos
Angioplastia com Balão/instrumentação , Materiais Revestidos Biocompatíveis , Stents Farmacológicos , Artéria Femoral , Doença Arterial Periférica/cirurgia , Artéria Poplítea , Idoso , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/mortalidade , Estudos Prospectivos , Resultado do Tratamento , Grau de Desobstrução Vascular
11.
J Cardiovasc Surg (Torino) ; 60(4): 490-495, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30698370

RESUMO

BACKGROUND: The EVOLUTION Study is a prospective, non-randomized study, investigating the iVolution stent (iVascular, Barcelona, Spain). The study was conducted at the vascular departments of four hospitals in Belgium. This manuscript reports the findings up to 12-month follow-up time for the total cohort. The primary endpoint of the study is primary patency at 12 months. Primary patency is defined as a target lesion without a hemodynamically significant stenosis on duplex ultrasound (>50%, systolic velocity ratio no greater than 2.4) and without Target Lesion Revascularization (TLR) within 12 months. METHODS: Between April 2015 and November 2016, 120 patients with TASC A&B femoropopliteal lesions were included. The mean lesion length was 89.63 mm. Most of the lesions were stenotic lesions (60.00%). RESULTS: Primary patency rate for the total patient population was 86.30% at 12-month follow-up. Freedom from TLR at 12-month was 88.00%. CONCLUSIONS: These results confirm the already existing enthusiasm of the use of bare metal self-expandable nitinol stents in the treatment of TASC A&B femoropopliteal lesions. Longer follow-up and a comparison or addition with drug-eluting technology has to be studied in the future.


Assuntos
Angioplastia com Balão , Doença Arterial Periférica/terapia , Stents Metálicos Autoexpansíveis , Adulto , Idoso , Idoso de 80 Anos ou mais , Ligas , Procedimentos Endovasculares , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Grau de Desobstrução Vascular
12.
Circulation ; 116(3): 285-92, 2007 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-17592075

RESUMO

BACKGROUND: Endoluminal treatment of superficial femoral artery lesions is a matter of controversy. The present study was designed to investigate the impact of nitinol stenting of superficial femoral artery lesions with a maximum length of 10 cm on restenosis and clinical outcomes at 1 year. METHODS AND RESULTS: Two hundred forty-four patients (168 men; 66+/-9 years) with a single superficial femoral artery lesion and chronic limb ischemia were randomized to implantation of a single Bard Luminexx 3 stent (123 patients) or stand-alone percutaneous transluminal angioplasty (PTA) (121 patients). Mean lesion length was 45 mm. Technical success (residual stenosis <50% for PTA, <30% for stenting) was achieved in 96 patients assigned to PTA (79%) and 117 patients assigned to stenting (95%); 13 PTA group patients (11%) "crossed over" to stenting. At 1 year, the primary end point of ultrasound-assessed binary restenosis was reached in 39 of 101 PTA group patients (38.6%) and 32 of 101 stent group patients (31.7%; absolute treatment difference, -6.9%; 95% CI, -19.7% to 6.2%; P=0.377). Target lesion revascularization rates at 1 year were 18.3% and 14.9%, respectively (absolute treatment difference, -3.3%; 95% CI, -13.0% to 6.4%; P=0.595). No statistically significant difference between treatment groups was observed at 12 months in the improvement by at least 1 Rutherford category of peripheral arterial disease. CONCLUSIONS: In the present study of patients with short superficial femoral artery lesions, the hypothesized absolute difference of 20% in binary restenosis at 1 year between the implantation of a single Luminexx nitinol stent and stand-alone PTA could not be demonstrated. A smaller difference requiring a larger trial might have been missed.


Assuntos
Ligas/administração & dosagem , Angioplastia com Balão , Implante de Prótese Vascular , Artéria Femoral/patologia , Stents , Idoso , Angioplastia com Balão/métodos , Implante de Prótese Vascular/métodos , Feminino , Artéria Femoral/diagnóstico por imagem , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/patologia , Oclusão de Enxerto Vascular/terapia , Humanos , Isquemia/diagnóstico por imagem , Isquemia/patologia , Isquemia/terapia , Masculino , Pessoa de Meia-Idade , Ultrassonografia
13.
Circ Cardiovasc Interv ; 11(10): e005654, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30354636

RESUMO

Background The IN.PACT Global Study was an international prospective single-arm clinical trial to evaluate the safety and effectiveness of a drug-coated balloon in the treatment of atherosclerotic disease of the superficial femoral and/or popliteal arteries (P1-P3) in subjects with intermittent claudication and/or rest pain. Prespecified subjects were selected for core-laboratory-adjudicated duplex ultrasound imaging, including a subcohort with long lesions (≥15 cm). Methods and Results Subjects were followed for 12 months. The primary safety end point was a composite of freedom from device- and procedure-related mortality through 30 days and freedom from major target limb amputation and clinically-driven target vessel revascularization through 12 months. An independent Clinical Events Committee adjudicated all adverse events. The primary effectiveness end point was primary patency at 12 months (by duplex ultrasound). The long lesion imaging cohort had 157 subjects (164 lesions). Mean lesion length was 26.40±8.61 cm. Provisional stents were implanted in 39.4% (63/160) of lesions. Primary patency by Kaplan-Meier estimate was 91.1%, and freedom from clinically-driven target lesion revascularization was 94.2% at 12 months. The primary safety composite end point was achieved by 94.0% (126/134) of subjects. There were no device- or procedure-related deaths or major target limb amputations. Conclusions The IN.PACT Admiral drug-coated balloon was safe and highly effective at 12 months after treatment in a rigorous independently adjudicated analysis of real-world subjects with lesions ≥15 cm in the superficial femoral and/or popliteal arteries (P1-P3). CLINICAL TRIAL REGISTRATION URL: https://www.clinicaltrials.gov . Unique identifier: NCT01609296.


Assuntos
Angioplastia com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Artéria Femoral , Paclitaxel/administração & dosagem , Doença Arterial Periférica/terapia , Artéria Poplítea , Dispositivos de Acesso Vascular , Idoso , Idoso de 80 Anos ou mais , Amputação Cirúrgica , Angioplastia com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Desenho de Equipamento , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Dupla
14.
JACC Cardiovasc Interv ; 11(10): 945-953, 2018 05 28.
Artigo em Inglês | MEDLINE | ID: mdl-29798770

RESUMO

OBJECTIVES: The IN.PACT Global Study is the largest prospective, multicenter, independently adjudicated trial to evaluate a paclitaxel drug-coated balloon in patients with lifestyle-limiting claudication and/or ischemic rest pain due to atherosclerotic disease of the femoropopliteal artery and includes complex lesions beyond what are typically included in randomized controlled trials. BACKGROUND: Randomized controlled trials have demonstrated the safety and efficacy of drug-coated balloons for the treatment of Trans-Atlantic Inter-Society Consensus Document II A and B lesions, but there is a need for large-scale prospective studies to evaluate a broader range of lesions. METHODS: The IN.PACT Global Study enrolled 1,535 subjects, and 1,406 (1,773 lesions) were included in the pre-defined clinical cohort analysis. Freedom from clinically driven target lesion revascularization was evaluated at 24 months. The safety composite endpoint was freedom from device- and procedure-related death through 30 days and freedom from target limb major amputation and clinically driven target vessel revascularization within 24 months. RESULTS: Mean lesion length was 12.1 cm, 35.5% were total occlusions, and 18.0% had in-stent restenosis. Freedom from clinically driven target lesion revascularization at 24 months was 83.3%, the composite safety endpoint was met in 81.7%, the 2-year all-cause mortality rate was 7.0%, and the major target limb amputation rate was 0.7%. Increased lesion length and the presence of de novo in-stent restenosis or coronary artery disease were associated with increased risk for clinically driven target lesion revascularization by 24 months. CONCLUSIONS: This real-world study of femoropopliteal artery disease treatment with drug-coated balloons confirmed positive findings reported from more strictly designed randomized controlled trials and showed that outcomes are durable in this population up to 2 years after treatment. (IN.PACT Global Clinical Study; NCT01609296).


Assuntos
Angioplastia com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Artéria Femoral , Claudicação Intermitente/terapia , Isquemia/terapia , Paclitaxel/administração & dosagem , Doença Arterial Periférica/terapia , Artéria Poplítea , Dispositivos de Acesso Vascular , Idoso , Angioplastia com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Constrição Patológica , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Claudicação Intermitente/diagnóstico por imagem , Claudicação Intermitente/fisiopatologia , Isquemia/diagnóstico por imagem , Isquemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Recidiva , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
15.
Circ Cardiovasc Interv ; 10(9)2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28916599

RESUMO

BACKGROUND: Studies assessing drug-coated balloons (DCB) for the treatment of femoropopliteal artery disease are encouraging. However, challenging lesions, such as severely calcified, remain difficult to treat with DCB alone. Vessel preparation with directional atherectomy (DA) potentially improves outcomes of DCB. METHODS AND RESULTS: DEFINITIVE AR study (Directional Atherectomy Followed by a Paclitaxel-Coated Balloon to Inhibit Restenosis and Maintain Vessel Patency-A Pilot Study of Anti-Restenosis Treatment) was a multicenter randomized trial designed to estimate the effect of DA before DCB to facilitate the development of future end point-driven randomized studies. One hundred two patients with claudication or rest pain were randomly assigned 1:1 to DA+DCB (n=48) or DCB alone (n=54), and 19 additional patients with severely calcified lesions were treated with DA+DCB. Mean lesion length was 11.2±4.0 cm for DA+DCB and 9.7±4.1 cm for DCB (P=0.05). Predilation rate was 16.7% for DA+DCB versus 74.1% for DCB; postdilation rate was 6.3% for DA+DCB versus 33.3% for DCB. Technical success was superior for DA+DCB (89.6% versus 64.2%; P=0.004). Overall bail-out stenting rate was 3.7%, and rate of flow-limiting dissections was 19% for DCB and 2% for DA+DCB (P=0.01). One-year primary outcome of angiographic percent diameter stenosis was 33.6±17.7% for DA+DCB versus 36.4±17.6% for DCB (P=0.48), and clinically driven target lesion revascularization was 7.3% for DA+DCB and 8.0% for DCB (P=0.90). Duplex ultrasound patency was 84.6% for DA+DCB, 81.3% for DCB (P=0.78), and 68.8% for calcified lesions. Freedom from major adverse events at 1 year was 89.3% for DA+DCB and 90.0% for DCB (P=0.86). CONCLUSIONS: DA+DCB treatment was effective and safe, but the study was not powered to show significant differences between the 2 methods of revascularization in 1-year follow-up. An adequately powered randomized trial is warranted. CLINICAL TRIAL REGISTRATION: http://www.clinicaltrials.gov. Unique Identifier: NCT01366482.


Assuntos
Angioplastia com Balão/instrumentação , Aterectomia , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Claudicação Intermitente/terapia , Paclitaxel/administração & dosagem , Doença Arterial Periférica/terapia , Dispositivos de Acesso Vascular , Calcificação Vascular/terapia , Grau de Desobstrução Vascular , Idoso , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/mortalidade , Aterectomia/efeitos adversos , Aterectomia/mortalidade , Fármacos Cardiovasculares/efeitos adversos , Desenho de Equipamento , Europa (Continente) , Feminino , Humanos , Claudicação Intermitente/diagnóstico por imagem , Claudicação Intermitente/mortalidade , Claudicação Intermitente/fisiopatologia , Masculino , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/mortalidade , Doença Arterial Periférica/fisiopatologia , Projetos Piloto , Estudos Prospectivos , Recidiva , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/mortalidade , Calcificação Vascular/fisiopatologia
16.
J Cardiovasc Surg (Torino) ; 57(6): 806-810, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27647337

RESUMO

Endovascular techniques have improved markedly over the past several decades. Plain old balloon angioplasty can only reach patencies around 40% after 1 year. Scaffolding stents have resulted in improved short-term results but encountered limitations for longer-term durability. With the introduction of drug-eluting technologies the process of intimal hyperplasia might be slowed, resulting in improved long-term patency results. At first, limus-eluting technologies were not able to transfer the enthusiasm from the coronaries to the infrainguinal vascular bed. However, the newer generation paclitaxel-eluting technologies perform significantly better in femoropopliteal arteries than their non-eluting or non-coated counterparts. The results of a prospective randomized trial comparing DES versus DCB is eagerly awaited. For the moment there seems, based on the meta-analysis, no difference between the two treatment modalities. Although, we need to keep in mind that DCB perform worse in long calcified lesions.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis/normas , Stents Farmacológicos/normas , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/normas , Artéria Femoral , Doença Arterial Periférica/terapia , Padrão de Cuidado , Constrição Patológica , Procedimentos Endovasculares/efeitos adversos , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Desenho de Prótese , Fatores de Risco , Resultado do Tratamento , Dispositivos de Acesso Vascular/normas , Grau de Desobstrução Vascular
17.
JACC Cardiovasc Interv ; 8(12): 1614-22, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26493253

RESUMO

OBJECTIVES: The aim of BIOLUX P-II (BIOTRONIK'S-First in Man study of the Passeo-18 LUX drug releasing PTA Balloon Catheter vs. the uncoated Passeo-18 PTA balloon catheter in subjects requiring revascularization of infrapopliteal arteries) trial was to compare the safety and efficacy of a novel paclitaxel-coated drug-eluting balloon (DEB) versus an uncoated balloon (percutaneous transluminal angioplasty [PTA]) in de novo or native restenotic lesions of the infrapopliteal arteries in patients with claudication and critical limb ischemia. BACKGROUND: DEB have shown promising results in femoropopliteal lesions, but data for infrapopliteal lesions are scarce. METHODS: In this prospective, multicenter, randomized first-in-man study, 72 patients were randomized 1:1 to either a Passeo-18 Lux DEB (Biotronik AG, Buelach, Switzerland) (n = 36) or Passeo-18 PTA (n = 36). Follow-up assessments were scheduled at 1, 6, and 12 months, with angiographic assessment at 6 months. Adverse events were adjudicated by an independent clinical events committee, and angiographic parameters were assessed by an independent core laboratory. RESULTS: The primary safety endpoint (a composite of all-cause mortality, target extremity major amputation, target lesion thrombosis, and target vessel revascularization at 30 days) was 0% in the DEB group versus 8.3% in the PTA group (p = 0.239). The primary performance endpoint (patency loss at 6 months) was 17.1% in the DEB group versus 26.1% in the PTA group (p = 0.298), and major amputations of the target extremity occurred in 3.3% versus 5.6% of the patients at 12 months, respectively. CONCLUSIONS: The Passeo-18 Lux DEB has been proven to be safe and effective in infrapopliteal lesions with comparable outcomes to PTA.


Assuntos
Angioplastia com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Claudicação Intermitente/terapia , Isquemia/terapia , Paclitaxel/administração & dosagem , Doença Arterial Periférica/terapia , Artéria Poplítea , Dispositivos de Acesso Vascular , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Amputação Cirúrgica , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/mortalidade , Estado Terminal , Desenho de Equipamento , Feminino , Humanos , Claudicação Intermitente/diagnóstico , Claudicação Intermitente/mortalidade , Claudicação Intermitente/fisiopatologia , Isquemia/diagnóstico , Isquemia/mortalidade , Isquemia/fisiopatologia , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/mortalidade , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Radiografia , Recidiva , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular , Adulto Jovem
18.
J Plast Reconstr Aesthet Surg ; 68(3): 362-71, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25488328

RESUMO

INTRODUCTION: Complex injuries to the central part of the face are difficult to reconstruct with the current plastic surgery methods. The ultimate one-staged approach to restore anatomy and vital facial functions is to perform a vascularized composite allotransplantation (VCA). METHODS: A 54-year-old man suffered from a high-energy ballistic injury, resulting in a large central facial defect. A temporary reconstruction was performed with a free plicated anterolateral thigh (ALT) flap. Considering the goal to optimally restore facial function and aesthetics, VCA was considered as an option for facial reconstruction. A multidisciplinary team approach, digital planning, and cadaver sessions preceded the transplantation. RESULTS: A digitally planned facial VCA was performed involving the bilateral maxillae, the hard palate, a part of the left mandible, and the soft tissues of the lower two-thirds of the face. Due to meticulous preparations, minimal adjustments were necessary to achieve good fitting in the recipient. At week 17, a grade 4 rejection was successfully treated; sensory and motor recovery was noted to occur from the fourth postoperative month. Several serious infectious and medical problems have occurred until 15-months postoperatively; following that, the clinical situation has remained stable. Two years postoperatively, the patient and his family are very satisfied with the overall outcome and social reintegration in the community is successful. CONCLUSION: The first face transplant in Belgium (#19 worldwide) was successful because of a meticulous 3-year preparation by a large multidisciplinary team. In our experience, preparatory cadaver dissections and three-dimensional (3D) computed tomographic (CT) modeling were valuable tools for an optimal intraoperative course and good alignment of the bony structures. Continuous long-term multidisciplinary follow-up is mandatory for surveillance of the complications associated with the immunosuppressive regime and for functional assessment of the graft.


Assuntos
Traumatismos Faciais/cirurgia , Transplante de Face , Cirurgia Assistida por Computador , Ferimentos por Arma de Fogo/cirurgia , Aloenxertos , Bélgica , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
19.
Trials ; 15: 63, 2014 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-24552184

RESUMO

BACKGROUND: The effectiveness and durability of endovascular revascularization therapies for chronic critical limb ischemia (CLI) are challenged by the extensive burden of infrapopliteal arterial disease and lesion-related characteristics (e.g., severe calcification, chronic total occlusions), which frequently result in poor clinical outcomes. While infrapopliteal vessel patency directly affects pain relief and wound healing, sustained patency and extravascular care both contribute to the ultimate "patient-centric" outcomes of functional limb preservation, mobility and quality of life (QoL). METHODS/DESIGN: IN.PACT DEEP is a 2:1 randomized controlled trial designed to assess the efficacy and safety of infrapopliteal arterial revascularization between the IN.PACT Amphirion™ paclitaxel drug-eluting balloon (IA-DEB) and standard balloon angioplasty (PTA) in patients with Rutherford Class 4-5-6 CLI. DISCUSSION: This multicenter trial has enrolled 358 patients at 13 European centers with independent angiographic core lab adjudication of the primary efficacy endpoint of target lesion late luminal loss (LLL) and clinically driven target lesion revascularization (TLR) in major amputation-free surviving patients through 12-months. An independent wound core lab will evaluate all ischemic wounds to assess the extent of healing and time to healing at 1, 6, and 12 months. A QoL questionnaire including a pain scale will assess changes from baseline scores through 12 months. A Clinical Events Committee and Data Safety Monitoring Board will adjudicate the composite primary safety endpoints of all-cause death, major amputation, and clinically driven TLR at 6 months and other trial endpoints and supervise patient safety throughout the study. All patients will be followed for 5 years. A literature review is presented of the current status of endovascular treatment of CLI with drug-eluting balloon and standard PTA. The rationale and design of the IN.PACT DEEP Trial are discussed. IN.PACT DEEP is a milestone, prospective, randomized, robust, independent core lab-adjudicated CLI trial that will evaluate the role of a new infrapopliteal revascularization technology, the IA-DEB, compared to PTA. It will assess the overall impact on infrapopliteal artery patency, limb salvage, wound healing, pain control, QoL, and patient mobility. The 1-year results of the adjudicated co-primary and secondary endpoints will be available in 2014. TRIAL REGISTRATION: NCT00941733.


Assuntos
Angioplastia com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Isquemia/terapia , Extremidade Inferior/irrigação sanguínea , Paclitaxel/administração & dosagem , Artéria Poplítea , Projetos de Pesquisa , Dispositivos de Acesso Vascular , Amputação Cirúrgica , Angioplastia com Balão/efeitos adversos , Protocolos Clínicos , Estado Terminal , Avaliação da Deficiência , Desenho de Equipamento , Europa (Continente) , Humanos , Isquemia/diagnóstico , Isquemia/fisiopatologia , Salvamento de Membro , Manejo da Dor , Medição da Dor , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Qualidade de Vida , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular , Cicatrização
20.
Circ Cardiovasc Interv ; 12(1): e007730, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30630355
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA