Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Oral Health ; 23(1): 324, 2023 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-37231447

RESUMO

OBJECTIVE: This study proposed a new classification method of bone quantity and quality at the dental implant site using cone-beam computed tomography (CBCT) image analysis, classifying cortical and cancellous bones separately and using CBCT for quantitative analysis. METHODS: Preoperative CBCT images were obtained from 128 implant patients (315 sites). First, measure the crestal cortical bone thickness (in mm) and the cancellous bone density [in grayscale values (GV) and bone mineral density (g/cm3)] at the implant sites. The new classification for bone quality at the implant site proposed in this study is a "nine-square division" bone classification system, where the cortical bone thickness is classified into A: > 1.1 mm, B:0.7-1.1 mm, and C: < 0.7 mm, and the cancellous bone density is classified into 1: > 600 GV (= 420 g/cm3), 2:300-600 GV (= 160 g/cm3-420 g/cm3), and 3: < 300 GV (= 160 g/cm3). RESULTS: The results of the nine bone type proportions based on the new jawbone classification were as follows: A1 (8.57%,27/315), A2 (13.02%), A3 (4.13%), B1 (17.78%), B2 (20.63%), B3 (8.57%) C1 (4.44%), C2 (14.29%), and C3 (8.57%). CONCLUSIONS: The proposed classification can complement the parts overlooked in previous bone classification methods (bone types A3 and C1). TRIAL REGISTRATION: The retrospective registration of this study was approved by the Institutional Review Board of China Medical University Hospital, No. CMUH 108-REC2-181.


Assuntos
Implantes Dentários , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Arcada Osseodentária , Tomografia Computadorizada de Feixe Cônico , Densidade Óssea
2.
J Dent Sci ; 19(1): 419-427, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38303847

RESUMO

Background/purpose: Before periapical surgery in the mandibular posterior teeth is performed, the thicknesses of the buccal alveolar bone wall and buccolingual root might be a critical issue. This study aimed to assess the anatomical structure of the posterior region of the mandible in Taiwanese individuals using cone-beam computed tomography (CBCT). Materials and methods: The CBCT images of 96 Taiwanese individuals (51 male and 45 female), which included 192 mandibular first molars and 192 mandibular second molars, were imported into medical imaging software to measure the buccal alveolar bone thickness and buccolingual root thickness at 3 mm above the root apex. Statistical analysis was conducted to examine the impact of tooth position, gender, and age on the anatomical position of mandibular molars. Results: The buccal alveolar bone thickness at 3 mm above the root apex of the mandibular second molar demonstrates a significantly higher value when compared to that of the first molar. Nonetheless, concerning the buccolingual root thickness, no significant differences were observed between these two teeth. In addition, the buccal alveolar bone thickness and buccolingual root thickness at 3 mm above the root apex may not be influenced by gender and age. Conclusion: The anatomical structures of the posterior region of the mandible in Taiwanese individuals exhibited variations between the mandibular first and second molars. However, these differences were not influenced by gender or age.

3.
Head Face Med ; 20(1): 33, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760840

RESUMO

BACKGROUND: Dental cone beam computed tomography (CBCT) is commonly used to evaluate cancellous bone density before dental implant surgery. However, to our knowledge, no measurement approach has been standardized yet. This study aimed to evaluate the relationship between three different regions of interest (ROI) methods on cancellous bone density at the dental implant site using dental CBCT images. METHODS: Patients' dental CBCT images (n = 300) obtained before dental implant surgery were processed using Mimics (Materialise, Leuven, Belgium). At the potential implant sites, the rectangle, cylinder, and surrounding cylinder ROI methods were used to measure bone density. Repeated measures one-way analysis of variance was performed to compare the three ROI methods in terms of measurement results. Pearson correlation analysis was performed to identify the likely pair-wise correlations between the three ROI methods. RESULTS: The density value obtained using the surrounding cylinder approach (grayscale value [GV],523.56 ± 228.03) was significantly higher than the values obtained using the rectangle (GV, 497.04 ± 236.69) and cylinder (GV,493 ± 231.19) ROI methods in terms of results. Furthermore, significant correlations were noted between the ROI methods (r > 0.965; p < 0.001). CONCLUSIONS: The density measured using the surrounding cylinder method was the highest. The choice of method may not influence the trends of measurement results. TRIAL REGISTRATION: This study was approved by the Institutional Review Board of China Medical University Hospital, No. CMUH111-REC3-205. Informed consent was waived by the Institutional Review Board of China Medical University Hospital, CMUH111-REC3-205, owing to the retrospective nature of the study.


Assuntos
Densidade Óssea , Tomografia Computadorizada de Feixe Cônico , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Idoso , Estudos Retrospectivos , Cuidados Pré-Operatórios/métodos , Implantação Dentária/métodos , Adulto Jovem , Implantes Dentários , Implantação Dentária Endóssea/métodos
4.
Diagnostics (Basel) ; 10(9)2020 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-32957724

RESUMO

Dental implant surgery is a common treatment for missing teeth. Its survival rate is considerably affected by host bone quality and quantity, which is often assessed prior to surgery through dental cone-beam computed tomography (CBCT). Dental CBCT was used in this study to evaluate dental implant sites for (1) differences in and (2) correlations between cancellous bone density and cortical bone thickness among four regions of the jawbone. In total, 315 dental implant sites (39 in the anterior mandible, 42 in the anterior maxilla, 107 in the posterior mandible, and 127 in the posterior maxilla) were identified in dental CBCT images from 128 patients. All CBCT images were loaded into Mimics 15.0 to measure cancellous bone density (unit: grayscale value (GV) and cortical bone thickness (unit: mm)). Differences among the four regions of the jawbone were evaluated using one-way analysis of variance and Scheffe's posttest. Pearson coefficients for correlations between cancellous bone density and cortical bone thickness were also calculated for the four jawbone regions. The results revealed that the mean cancellous bone density was highest in the anterior mandible (722 ± 227 GV), followed by the anterior maxilla (542 ± 208 GV), posterior mandible (535 ± 206 GV), and posterior maxilla (388 ± 206 GV). Cortical bone thickness was highest in the posterior mandible (1.15 ± 0.42 mm), followed by the anterior mandible (1.01 ± 0.32 mm), anterior maxilla (0.89 ± 0.26 mm), and posterior maxilla (0.72 ± 0.19 mm). In the whole jawbone, a weak correlation (r = 0.133, p = 0.041) was detected between cancellous bone density and cortical bone thickness. Furthermore, except for the anterior maxilla (r = 0.306, p = 0.048), no correlation between the two bone parameters was observed (all p > 0.05). Cancellous bone density and cortical bone thickness varies by implant site in the four regions of the jawbone. The cortical and cancellous bone of a jawbone dental implant site should be evaluated individually before surgery.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA