Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-29510082

RESUMO

Polyamides (PAs) are used in the production of various food contact materials (FCMs) and articles such as kitchen utensils and packaging material. Cyclic oligomers have been identified as potential migrants from PA. This study describes the development, validation and application of a multi-oligomer analytical method based on LC-ESI-MS/MS for the identification and quantification of eight cyclic oligomers of PA 6 and four PA 66 migrating from FCMs into food simulant B (3% acetic acid) and beverages. It was proved that doubly charged precursor ions of the cyclic PA 6 and PA 66 oligomers above a mass of 500 Da are formed during the ionisation process of the electrospray technique used. Direct injection of a diluted food simulant into the LC-ESI-MS/MS system after migration makes the validated method a valuable tool for investigating migration of cyclic PA oligomers. The validation results demonstrate that the multi-oligomer method is applicable for the analysis of cyclic PA 6 and PA 66 oligomers in food simulant B. For all investigated cyclic PA oligomers, detection limits were in the range of 0.1-1.1 µg/l. Linearity (r2 ≥ 0.99), trueness values between 91% and 122%, and intra-day (RSDr < 10%) and inter-day precision (RSDR < 19%) were determined and satisfied validation criteria set out by the European Reference Laboratory for FCMs. The method was extended to tap water and tea. Finally, the multi-oligomer method was successfully applied to determine cyclic PA oligomers in migration solutions originating from different PA FCMs. In all migration solutions, concentrations of cyclic PA oligomers were determined above the LOQ. A preliminary risk assessment based on in silico tools was performed. The results demonstrate the urgent need for toxicological data that would facilitate the evaluation of the health risk of cyclic PA oligomers.


Assuntos
Contaminação de Alimentos/análise , Embalagem de Alimentos , Nylons/análise , Cromatografia Líquida de Alta Pressão , Estrutura Molecular , Espectrometria de Massas em Tandem
2.
PLoS One ; 13(7): e0200778, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30036389

RESUMO

In order to investigate the release of aluminium ions from food contact materials, three different types of uncoated aluminium menu trays for single use were tested with the foodstuffs sauerkraut juice, apple sauce and tomato puree, as well as with the food simulants 5 g/L citric acid solution and artificial tap water. To mimic a consumer relevant exposure scenario, the aluminium trays were studied using time and temperature gradients according to the Cook & Chill method, also taking into account storage time at elevated temperatures during the delivery period. The release of aluminium was found to exceed the specific release limit (SRL) of 5 mg aluminium per kilogram of food specified by the Council of Europe by up to six times. Furthermore, a release of thallium was also detected unexpectedly. Kinetic studies showed a comparable behaviour in the release of aluminium, manganese and vanadium as components of the aluminium alloy itself. In contrast, thallium could be identified as a surface contaminant or impurity because of an entirely different kinetic curve. Kinetic studies also allowed activation energy calculations. Additional camping saucepans were tested as an article for repeated use. In three subsequent release experiments with citric acid (5 g/L), artificial tap water and tomato puree as benchmark foodstuffs, the results were comparable to those of the uncoated wrought alloy aluminium trays.


Assuntos
Ligas , Alumínio/química , Contaminação de Alimentos/análise , Embalagem de Alimentos , Íons , Tálio/química , Brassica , Ácido Cítrico , Culinária , Alimentos , Cinética , Solanum lycopersicum , Malus , Espectrometria de Massas , Temperatura , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA