Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur Cell Mater ; 33: 1-12, 2017 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-28054333

RESUMO

Atrophic non-unions are a major clinical problem. Mineral coated microparticles (MCM) are electrolyte-coated hydroxyapatite particles that have been shown in vitro to bind growth factors electrostatically and enable a tuneable sustained release. Herein, we studied whether MCM can be used in vivo to apply Bone Morphogenetic Protein-2 (BMP-2) to improve bone repair of atrophic non-unions. For this purpose, atrophic non-unions were induced in femurs of CD-1 mice (n = 48). Animals either received BMP-2-coated MCM (MCM + BMP; n = 16), uncoated MCM (MCM; n = 16) or no MCM (NONE; n = 16). Bone healing was evaluated 2 and 10 weeks postoperatively by micro-computed tomographic (µCT), biomechanical, histomorphometric and immunohistochemical analyses. µCT revealed more bone volume with more highly mineralised bone in MCM + BMP femurs. Femurs of MCM + BMP animals showed a significantly higher bending stiffness compared to other groups. Histomorphometry further demonstrated that the callus of MCM + BMP femurs was larger and contained more bone and less fibrous tissue. After 10 weeks, 7 of 8 MCM + BMP femurs presented with complete osseous bridging, whereas NONE femurs exhibited a non-union rate of 100 %. Of interest, immunohistochemistry could not detect macrophages within the callus, indicating a good biocompatibility of MCM. In conclusion, the local application of BMP-2-coated MCM improved bone healing in a challenging murine non-union model and, thus, should be of clinical interest in the treatment of non-unions.


Assuntos
Proteína Morfogenética Óssea 2/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Consolidação da Fratura/efeitos dos fármacos , Fraturas não Consolidadas/patologia , Microesferas , Minerais/farmacologia , Animais , Fenômenos Biomecânicos/efeitos dos fármacos , Líquidos Corporais/química , Proteína Morfogenética Óssea 2/administração & dosagem , Osso e Ossos/efeitos dos fármacos , Osso e Ossos/patologia , Calo Ósseo/efeitos dos fármacos , Calo Ósseo/patologia , Materiais Revestidos Biocompatíveis/administração & dosagem , Preparações de Ação Retardada , Fêmur/diagnóstico por imagem , Fêmur/efeitos dos fármacos , Fêmur/patologia , Fêmur/fisiopatologia , Fraturas não Consolidadas/fisiopatologia , Imuno-Histoquímica , Cinética , Camundongos , Microscopia Eletrônica de Varredura , Osteotomia , Microtomografia por Raio-X
2.
Eur J Trauma Emerg Surg ; 48(5): 3757-3764, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34618166

RESUMO

BACKGROUND: Various plate shapes and implant configurations are used for stabilization of acetabulum fractures via anterior approaches. Little is known about the biomechanical stability of a two-dimensionally shaped "conventional" plate ("J-Plate"-JP) in comparison to three-dimensionally shaped plate configurations (3DP). In addition, the augmentary effect of an infra-acetabular lag-screw (IACS) fixation for anterior column and posterior hemi-transverse acetabulum fractures has not been clarified in comparison of JP and 3DP constructs. This study analyzed the difference between the biomechanical stability of JP compared to 3DP and the role of an IACS in a standardized acetabular fracture model in a single-leg stance loading configuration. METHODS: In an artificial bone substitute pelvis model (Synbone© Malans, Switzerland), a typical and standardized fracture pattern (anterior column and posterior hemi-transverse) was created with osteotomy jigs. After anatomic reduction the stabilization was performed using JP or 3DP. Eight pelvises per group were axially loaded in a single-leg stance model up to 400 N. After the load cycle, an additional infra-acetabular screw was placed and the measurement repeated. Fragment displacement was recorded by an optical tracking system (Optitrack Prime 13®, Corvallis, USA). RESULTS: In the pure placement, 3DP provided significantly superior stability when compared to JP. Augmentation of JP by IACS increased the stability significantly, up to the level of 3DP alone, whereas augmentation of the 3DP did not result in further increase of overall stability. CONCLUSION: The anatomically shaped plate alone provides a superior biomechanical stability in fixation of an anterior column and posterior hemi-transverse fracture model. In a JP fixation the augmentation by IACS provides similar strength as the anatomically shaped 3DP. By use of the anatomically shaped 3DP the need of a clinically risky application of IACS might be avoidable. LEVEL OF EVIDENCE: IV, Experimental study.


Assuntos
Substitutos Ósseos , Fraturas Ósseas , Fraturas do Quadril , Fraturas da Coluna Vertebral , Acetábulo/lesões , Acetábulo/cirurgia , Fenômenos Biomecânicos , Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Humanos
3.
Nuklearmedizin ; 32(2): 73-81, 1993 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-8479933

RESUMO

Persisting postoperative pain of the thigh is a common problem of cementless hip endoprostheses occurring in about 15-20% of the patients. We performed a comparative study including patients with (n = 40) and without (n = 45) pain of the thigh. 85 cementless porous-coated anatomic (PCA) hip endoprostheses in 74 patients were examined. All patients underwent clinical examination including a standardized questionnaire, x-ray, and 3-phase bone scintigraphy. Slight or moderate 99mTc-MDP uptake in the area of the greater and lesser trochanter as well as at the tip was a common finding in PCA prostheses in patients without pain and was not a sign of loosening of the hip. Radiologically, there was no difference between patients with and without pain. However, persisting pain of the thigh in patients with PCA prosthesis corresponded with an increased uptake at the tip and the medial and lateral femur, not being a sign of loosening even in this group. The special biomechanical conditions of cementless prostheses causing inhomogeneous intraosseous stress distribution are supposed to be the reason for that.


Assuntos
Osso e Ossos/diagnóstico por imagem , Prótese de Quadril , Dor Pós-Operatória/diagnóstico por imagem , Coxa da Perna , Adulto , Idoso , Idoso de 80 Anos ou mais , Cimentos Ósseos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cintilografia , Medronato de Tecnécio Tc 99m
4.
Acta Biomater ; 5(6): 1991-2001, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19286433

RESUMO

Scaffolds for tissue engineering should be biocompatible and stimulate rapid blood vessel ingrowth. Herein, we analyzed in vivo the biocompatibility and vascularization of three novel types of biodegradable porous polyurethane scaffolds. The polyurethane scaffolds, i.e., PU-S, PU-M and PU-F, were implanted into dorsal skinfold chambers of BALB/c mice. Using intravital fluorescence microscopy we analyzed vascularization of the implants and venular leukocyte-endothelial cell interaction in the surrounding host tissue over a 14 day period. Incorporation of the scaffolds was analyzed by histology, and a WST-1 assay was performed to evaluate their cell biocompatibility in vitro. Our results indicate that none of the polyurethane scaffolds was cytotoxic. Accordingly, rolling and adherent leukocytes in venules of the dorsal skinfold chamber were found in a physiological range after scaffold implantation and did not significantly differ between the groups, indicating a good in vivo biocompatibility. However, the three scaffolds induced a weak angiogenic response with a microvessel density of only approximately 47-60 and approximately 3-10cm/cm(2) in the border and centre zones of the scaffolds at day 14 after implantation. Histology demonstrated that the scaffolds were incorporated in a granulation tissue, which exhibited only a few blood vessels and inflammatory cells. In conclusion, PU-S, PU-M and PU-F scaffolds may be used to generate tissue constructs which do not induce a strong inflammatory reaction after implantation into patients. However, the scaffolds should be further modified or conditioned in order to accelerate and improve the process of vascularization.


Assuntos
Implantes Absorvíveis , Regeneração Tecidual Guiada/instrumentação , Neovascularização Fisiológica/efeitos dos fármacos , Poliuretanos/farmacologia , Animais , Desenho de Equipamento , Regeneração Tecidual Guiada/métodos , Teste de Materiais , Camundongos , Camundongos Endogâmicos BALB C
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA