Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Med Sci Monit ; 30: e943401, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38444156

RESUMO

BACKGROUND Several auxiliary features have been proposed to achieve sustainable retention for short-prepared dental crowns; however, achieving retention is challenging. This study aimed to assess the impact of increased total occlusal convergence and auxiliary preparation factors like box and groove on the retention form of short tooth preparations. MATERIAL AND METHODS Eighty resin machine-milled dies with a height of 3 mm and a deep chamfer margin of 1 mm were prepared to mimic the short-prepared molar. Initially, 2 teeth were prepared following the guidelines, and the total occlusal convergence was kept at 10° and 20°, respectively. Auxiliary features such as the proximal box and buccal groove were prepared on separate 20° dies. Eighty dies were prepared with 10 samples each for 10°, 20°, 20° with proximal box and 20° with buccal groove for zirconia (n=40) and metal crowns (n=40). Cementation was done with glass ionomer luting cement, and a pull-off test was conducted. Data were analyzed using one-way analysis of variance and post hoc fisher least significant difference test (P<0.05). RESULTS The highest mean was observed in the proximal box group with the metal crown (14.59), and the lowest in the group with 20° zirconia crowns (9.12). Within groups, the highest retentive values were found for the 20° taper with proximal box preparation; the lowest was for the 20° taper group. CONCLUSIONS Within the study limitations, it could be concluded that incorporating a proximal box or buccal groove in short tooth preparations with an increased total occlusal convergence improved retentive values.


Assuntos
Cimentos de Ionômeros de Vidro , Boca , Zircônio , Membrana Celular , Coroas
2.
Med Sci Monit ; 29: e940949, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37386761

RESUMO

BACKGROUND This study aimed to compare a composite resin (Duo-Shade) shade guide with Vita ceramic shades before/after chemical and autoclave sterilization. MATERIAL AND METHODS Color values (L*a*b*) were recorded directly from shade tabs of prefabricated composite resin (Brilliant NG Universal Duo-Shade) and ceramic (Vita classic) shade guide with a calibrated spectrophotometer (Vita Easy Shade Advance 4.0). Seventy-two composite resin disk samples with 6 different shades (A1/B1, A2/B2, A3/D3, A3.5/B3, A4/C4, and C2/C3) (n=12 each) were divided into 2 groups (Gp) - Gp A (Autoclave) and Gp C (Chemical) (15 cycles) - to assess their influence on respective shades. Mean values calculated the color differences (ΔE) while differences in color values (L*a*b*) were graded on the National Bureau of Standards (NBS) 6-grade scale and assessed for Clinical Acceptance/Perceptible Threshold (CAT), (CPT). All differences were considered significant if the color difference ΔE was ≥3.3. RESULTS Only 2 out of 12 Shade tabs (C2C3, A4C4) of composite resin matched to Vita shade tab C2 and C4 (ΔE ≤3.3). Both groups showed notable color differences after respective sterilization protocols, with color differences in Gp A significantly higher than Gp C (DE ³3.3). Within groups, all shades in Gp A showed remarkably different color changes, with shade C2C3 and A1B1 being denoted as clinically unacceptable. CONCLUSIONS Manufacturer-provided shade guides do not match ceramic shades as claimed and chemical sterilization using 10% Deconex was associated with less color changes than with autoclave sterilization.


Assuntos
Resinas Compostas , Esterilização , Resinas Compostas/uso terapêutico , Cerâmica/uso terapêutico
3.
Medicina (Kaunas) ; 59(3)2023 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-36984502

RESUMO

The coronal seal in root canal-treated teeth may be compromised depending on the accuracy of post space preparation and post cementation along with remaining gutta-percha. Root canal treatment can be compromised by endotoxins released by the coronal bacteria as a result of microleakage. The study was conducted by undergraduate students to measure the gap between the cemented post and residual gutta-percha. In total, 217 endodontically treated teeth were evaluated with intraoral peri-apical radiographs. Based on the intraoral periapical radiographic examination in the CS-R4 program, Group I had no gap, Group II had a gap of >0 to 2 mm, and Group III had a gap of more than 2 mm between the end of the cemented post and the remaining gutta-percha. In total, 40% (n = 87) of the teeth had no gap, 59% (127) had a gap of >0 to 2 mm, and 1% (n = 3) had a gap of more than 2 mm between the cemented post end and remaining gutta. Chi square test revealed a significant difference in the gap between the post and remaining gutta-percha between males and females students (p < 0.001). In terms of the gap between the cemented post end and the residual gutta-percha, the root canal treated teeth with post and core by undergraduates were clinically acceptable.


Assuntos
Materiais Restauradores do Canal Radicular , Dente não Vital , Humanos , Guta-Percha , Estudos Transversais , Estudos Retrospectivos
4.
Med Sci Monit ; 28: e936892, 2022 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-35711131

RESUMO

BACKGROUND Miswak is a form of chewing stick used to clean teeth in different parts of the world, including Saudi Arabia. We present a description of the effects of miswak derivatives, namely toothpaste, mouthwash, and brushing sticks, on the mean color changes (DE00), compressive fracture resistance values, and fracture modes of polymer-based computer-aided design (CAD) and computer-aided manufactured (CAM) prosthetic materials. MATERIAL AND METHODS Eighty-one rectangular-shaped samples were prepared from lithium disilicate glass-ceramic (IPS e.max CAD), zirconia-reinforced lithium silicate (Vita Suprinity), and monochromatic tooth-colored feldspar (Vitablocs Mark II) CAD/CAM ceramics. The color parameters were recorded using spectrophotometer before and after exposing the specimens to the different miswak oral hygiene derivatives for 15 days. Compressive fracture resistance values and fracture types were also assessed, and statistical analysis was performed. RESULTS Vita Suprinity and Vitablocs Mark II miswak sticks had the highest ΔE00 values. Moreover, miswak mouthwash had the lowest ΔE00 values, with significant differences among groups. IPS e.max CAD miswak sticks had the highest mean values of compressive fracture. Vitablocs Mark II had the lowest values for mouthwash and toothpaste. Significant differences were found within the IPS e.max CAD group. Reparable fractures were found in IPS e.max CAD, while semi-reparable fractures were seen in other groups. CONCLUSIONS Most ΔE00 values were within the acceptable clinical range, with IPS e.max CAD showing superior color stability. The mouthwash group showed minimal ΔE00. IPS e.max CAD had the highest mean compressive fracture resistance values with reparable fracture types.


Assuntos
Antissépticos Bucais , Polímeros , Cerâmica , Cor , Desenho Assistido por Computador , Computadores , Porcelana Dentária , Teste de Materiais , Antissépticos Bucais/farmacologia , Propriedades de Superfície , Cremes Dentais
5.
J Contemp Dent Pract ; 22(7): 784-792, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34615785

RESUMO

AIMS AND OBJECTIVES: This study compared the supraeruption of teeth for study casts (SCs) and panoramic radiographs (PRs) and its relation to tooth type, arch, facial sides, presence of occlusal interferences, and type of tooth movements. MATERIALS AND METHODS: A total of 65 patients with their SCs and PRs were recruited. Supraerupted tooth type, arches, sides involved, and the presence of occlusal interferences were recorded. The SCs for supraerupted teeth were photographed, and supraeruption from PRs was recorded from the patients' files. The values were transferred to a software program and assessed. RESULTS: The highest frequency was observed among the younger-age group and molars in both arches. Working side (WS) and retruded cuspal position (RCP) interferences were recorded the highest. Supraeruption values of 0.7-1.2 mm accounted for 47.5% (38) of the total. Tilting and tipping of teeth were the highest, followed by buccolingual displacement. Kappa tests showed good intraexaminer reliability and Bland-Altman plot showed 95% confidence interval band. CONCLUSIONS: No significant differences were observed in the supraeruption values between the type of tooth among different subgroups of SCs and PRs. Significant differences were recorded between the types and sites of teeth, with a higher ratio observed in molar teeth, mandibular arch, and young age group. RCP and WS were the most recorded occlusal interferences and buccolingual displacement, and tilting and tipping were the most noticeable occlusal tooth movements. CLINICAL SIGNIFICANCE: Diagnosis and measurements of supraeruption are essential, useful, and significant steps before treatments for replacement of missing tooth/teeth as well as corrections of occlusal interferences during different mandibular movements.


Assuntos
Má Oclusão , Erupção Dentária , Humanos , Reprodutibilidade dos Testes
6.
Med Sci Monit ; 26: e918219, 2020 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-31956260

RESUMO

BACKGROUND The habit of khat (Catha Edulis Forskal) chewing is widely practiced in the southern regions of Saudi Arabia, Yemen, and East Africa. This social habit has tremendous effects on oral and general health of khat chewers. Khat may affect bacterial species in plaque biofilms on oral rehabilitation materials. This preliminary case-controlled study aimed to assess and compare the effect of khat chewing on bacterial biodiversity between non-khat chewers (NKC) and khat chewers (KC) in oral biofilms on oral rehabilitation materials using polymerase chain reaction (PCR). MATERIAL AND METHODS Fifty participants were organized into 2 equal groups of NKC and KC, each containing 5 subgroups related to filling material type. Some participants had amalgam (A) or composite (C) restorations, while others had feldspathic porcelain (FP), nickel chromium (NC), and zirconia ceramic (ZC) crowns or bridges. Oral biofilm samples were collected from all participants, DNA was extracted, and samples were subjected to PCR. Bacterial species were then identified and counted. PCR products were sequenced to detect similarity. Partial 16S rRNA gene sequences of the current study samples were compared with 16S rRNA gene sequences from GenBank using BLAST on the National Center for Biotechnology Information website. RESULTS The Streptococcus sp. was the most common bacterial species among our participants (40; 80%), followed by Lactobacillus and Veillonella spp., accounting for 12% (6) and 8% (4), respectively. Streptococcus sp. was observed equally among NKC and KC, but Lactobacillus and Veillonella spp. were higher in KC and NKC, respectively. Lactobacillus was associated mainly with prosthetic materials, and Streptococcus was found among all examined dental restorative materials. CONCLUSIONS This research concluded that khat chewing significantly affects bacterial biodiversity in oral biofilms in the presence of different restorative and prosthetic dental materials.


Assuntos
Catha/química , Mastigação , Microbiota , Bactérias/isolamento & purificação , Materiais Dentários , Feminino , Humanos , Masculino , Filogenia
7.
Pharm Dev Technol ; 25(4): 416-431, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31852330

RESUMO

The present study was aimed to optimize capsulated unfolding type gastroretentive bilayer film constituting immediate release (IR) layer of amlodipine besylate and sustained release (SR) layer of atorvastatin calcium. A three-factor, three-level Box-Behnken-design was used to optimize bilayer film with dual-release characteristics. The selected independent variables were HPMC-K3, Eudragit RSPO, and Carbopol 934P and the responses were floating duration, swelling index, and in vitro release from SR layer in 8 h. The films were also assessed for pharmacotechnical characteristics, release kinetics, DSC, FTIR, and SEM. The pharmacokinetics of the drugs from the optimized formulation was compared with the marketed formulation in rabbits. The capsulated accordion film unfolded and provided SR of atorvastatin for 8 h (96.76% ± 0.71) and IR of amlodipine within 25 min (98.07% ± 0.62) for the optimized formulation (F14). The swelling index and floating duration for the optimized formulation were 140.48 ± 0.57 and 8.53 ± 0.10 h, respectively. Results of pharmacokinetics showed that faster absorption of amlodipine and improved bioavailability (2.16-fold) of atorvastatin in blood was made available through bilayer film. In vitro-in vivo correlation was established using numerical deconvolution method. It can be concluded that the capsulated gastroretentive system provided site specific simultaneous SR of antihyperlidemic drug and IR of antihypertensive drug as single pill that has therapeutic potential to manage cardiovascular risk.


Assuntos
Anlodipino/administração & dosagem , Anticolesterolemiantes/administração & dosagem , Anti-Hipertensivos/administração & dosagem , Atorvastatina/administração & dosagem , Preparações de Ação Retardada/química , Acrilatos/química , Anlodipino/farmacocinética , Animais , Anticolesterolemiantes/farmacocinética , Anti-Hipertensivos/farmacocinética , Atorvastatina/farmacocinética , Liberação Controlada de Fármacos , Lactose/análogos & derivados , Lactose/química , Masculino , Metilcelulose/análogos & derivados , Metilcelulose/química , Ácidos Polimetacrílicos/química , Coelhos
8.
J Prosthodont ; 28(1): e6-e12, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28102940

RESUMO

PURPOSE: To investigate the effect of cast modifications on denture base adaptation in coronal and sagittal projections following maxillary complete denture processing. MATERIALS AND METHODS: A total of 60 edentulous maxillary casts (n = 10) were distributed among six groups. Group 1 was the control group with no modification, groups 2 through 6 included a butterfly postdam preparation, groups 3 and 4 also included a 10-mm wide/4-mm deep box with addition of four round holes in group 4, and groups 5 and 6 also included a 20-mm wide/4-mm deep box with addition of four round holes in group 6. The boxes were prepared at the mid-heel area of the casts. Two layers of baseplate wax (1 mm each) were used to standardize denture base thickness across the groups. A standard technique was used to replicate the denture tooth set-up, and standardized processing was done for all the groups. Following deflasking, casts with the dentures were sectioned in the coronal and sagittal directions. Microscopic pictures were taken at preselected points. Data were organized in tables, and statistical analyses were performed using repeated measure ANOVA, Tukey post hoc tests, and post hoc comparison tests set at 5% level of significance. RESULTS: Maximum gaps were measured at the mid-palatal area followed by nearby areas and the areas near ridge crests in both coronal and sagittal projections. The analyses revealed significant differences between the groups in coronal projection (1/2, 3/4, 5/6) and sagittal projection (1, 2, 3/4, 5/6) without significant differences within the pairs. The groups were ranked from the highest group 1 to the lowest group 6 relative to the gap means. Post hoc comparisons showed that points 1C and 2A had the highest gap means across the study groups. CONCLUSIONS: Within the limitations of this study, it can be extrapolated that the denture base adaptation can be effectively increased with the box preparation at the mid-heel aspect of the casts. Significant reduction of gaps was seen when the box size increased from 10 to 20 mm in coronal and sagittal projections; however, the addition of four holes had no significant effect on gap size alterations.


Assuntos
Técnica de Fundição Odontológica , Adaptação Marginal Dentária , Bases de Dentadura , Prótese Total Superior , Planejamento de Dentadura , Humanos
9.
J Prosthodont ; 27(3): 232-239, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27060929

RESUMO

PURPOSE: The changing dynamics of an aging mouth influence the position of the neutral zone (NZ). While the advantage of the NZ concept in complete denture treatment is quite established, what is not clearly understood is its position in relation to the crest of the residual ridge due to conflicting reports from previous studies. The purpose of this study was to investigate the distance and direction of NZ position in relation to crest of the residual ridge in edentulous patients and its association with age, gender, and period of edentulism. MATERIALS AND METHODS: A cross-sectional study was conducted in 133 patients (70 males, 63 females) with a mean age of 58.81 ± 11.78 years. NZ recording was done using admix material by following standard procedures. Two metallic wires were adapted, one on the ridge and another on the center of the occlusal rims, and standardized digital radiographs were made. The position of NZ in relation to the crest of the residual ridge was recorded by noting the direction and measuring the distance between the adapted wires digitally at five locations (right molar, right premolar, incisor, left molar, left premolar regions). RESULTS: Age, gender, and period of edentulism had no significant association with the position of NZ. No specific trend was observed in the in NZ position with a non-significant correlation. CONCLUSIONS: Distance and the direction of neutral zone position in relation to crest of the residual ridge in edentulous patients bear no significant relationship with factors such as age, gender, and period of edentulism.


Assuntos
Processo Alveolar/anatomia & histologia , Prótese Total , Boca Edêntula/terapia , Adulto , Fatores Etários , Idoso , Processo Alveolar/diagnóstico por imagem , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Boca Edêntula/diagnóstico por imagem , Radiografia Dentária Digital , Fatores Sexuais
10.
J Contemp Dent Pract ; 19(3): 318-323, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29603706

RESUMO

INTRODUCTION: Ceramics are widely applied in dentistry owing to their excellent mechanical and physical attributes. The most popular ceramics are Lava™, KaVo Everest, and Cercon. However, it is unclear whether or not a different surface treatment along with low-temperature aging and mechanical loading (ML) affects the physical properties of computer-aided design (CAD)/computer-aided manufacturing (CAM)-machined yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) ceramic. AIM: The objective of this research was to assess the impact of various surface treatments as air-particle abrasion, ML, low-temperature degradation (LTD), and their cumulative effects on biaxial flexural properties of Y-TZP. MATERIALS AND METHODS: Totally, 50 specimens were fabricated by CAD-CAM machining from Cercon® and divided into five groups following different surface treatments as control (C), air-particle abrasion (Si), ML, LTD, and cumulative treatment (CT) group. Results were investigated by two-way analysis of variance (ANOVA) and Tukey honest significant difference (HSD) test. RESULTS: The highest biaxial flexural strength was observed in the Si group (950.2 ± 126.7 MPa), followed by the LTD group (861.3 ± 166.8 MPa), CT group (851.2 ± 126.5 MPa), and the least with ML (820 ± 110 MPa). A significant difference was observed in the two-way ANOVA test. X-ray diffraction (XRD) analysis showed that the control group consists of 100% tetragonal zirconia and the maximum amount of monoclinic phase was obtained after LTD. CONCLUSION: No negative effect on biaxial flexural strength was observed; indeed, it increases the biaxial strength. Hence, these surface treatments can be done in routine clinical practice to improve the performance of ceramic restoration.


Assuntos
Porcelana Dentária/uso terapêutico , Ítrio/uso terapêutico , Zircônio/uso terapêutico , Abrasão Dental por Ar/métodos , Desenho Assistido por Computador , Porcelana Dentária/química , Planejamento de Prótese Dentária , Análise do Estresse Dentário , Humanos , Propriedades de Superfície , Resistência à Tração , Difração de Raios X , Ítrio/química , Zircônio/química
11.
J Prosthodont ; 26(8): 659-663, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26883552

RESUMO

PURPOSE: To investigate the effect of different cast modifications on the vertical and horizontal tooth position following maxillary complete denture processing. MATERIALS AND METHODS: A total of 60 maxillary master casts were prepared and arranged in six groups (n = 10). Variation in modifications between study groups 1 through 6 were as follows: no modification, butterfly post palatal seal preparation only, butterfly post palatal seal preparation with 10 mm wide/4 mm deep box, butterfly post palatal seal preparation with 10 mm wide/4 mm deep box and four round holes, butterfly post palatal seal preparation with 20 mm wide/4 mm deep box, butterfly post dam preparation with 20 mm wide/4 mm deep box and four round holes, respectively. The boxes in the respective groups were prepared on the mid-heel area of the cast. The first group was included in the study as control. The initial master cast was indexed to standardize the measurement technique on all specimens before duplication. Maxillary denture tooth set-up was completed and indexed using laboratory putty to ensure a similar set-up on all specimens. Vertical and horizontal tooth positions were measured for the maxillary left central incisor, right and left first molars in waxed complete dentures, and following processing. The measurements were done using a digital vernier caliper with manufacturing accuracy of up to 0.01 mm. The study data were entered in a Microsoft Excel Spreadsheet. Statistical analysis was done using a paired Student t-test, ANOVA, and Tukey post hoc test set at 5% level of significance. RESULTS: The paired t-test (within groups) showed significant change in all linear tooth positions for groups 1 and 2. Groups 3 through 6 had significant change in vertical dimension only. One-way ANOVA indicated that no significant difference was seen in the vertical tooth movements between the groups; however, statistically significant reduction was seen in the horizontal tooth movements at the maxillary left central incisor, right and left first molars for groups 3 through 6 when compared to others without significant difference between them. CONCLUSIONS: Within the limitations of the study, it was concluded that the movement of the teeth horizontally could be reduced with master cast modification (box alone or box and round holes) whereas the vertical movement of the teeth was not affected by the cast modifications made across all groups.


Assuntos
Resinas Acrílicas , Técnica de Fundição Odontológica , Prótese Total Superior , Planejamento de Dentadura/métodos , Humanos , Maxila , Dimensão Vertical
12.
J Contemp Dent Pract ; 18(7): 541-548, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28713105

RESUMO

INTRODUCTION: Several techniques and methods have been proposed to estimate the anterior teeth dimensions in edentulous patients. However, this procedure remains challenging especially when preextraction records are not available. Therefore, the purpose of this study is to evaluate some of the existing extraoral and intraoral methods for estimation of anterior tooth dimensions and to propose a novel method for estimation of central incisor width (CIW) and length (CIL) for Saudi population. MATERIALS AND METHODS: Extraoral and intraoral measurements were recorded for a total of 236 subjects. Descriptive statistical analysis and Pearson's correlation tests were performed. Association was evaluated between combined anterior teeth width (CATW) and interalar width (IAW), intercommisural width (ICoW) and interhamular notch distance (IHND) plus 10 mm. Evaluation of the linear relationship between central incisor length (CIL) with facial height (FH) and CIW with bizygomatic width (BZW) was also performed. RESULTS: Significant correlation was found between the CATW and ICoW and IAW (p-values <0.0001); however, no correlation was found relative to IHND plus 10 mm (p-value = 0.456). Further, no correlation was found between the FH and right CIL and BZW and right CIW (p-values = 0.255 and 0.822). The means of CIL, CIW, incisive papillae-fovea palatinae (IP-FP), and IHND were used to estimate the central incisor dimensions: CIL = FP-IP distance/4.45, CIW = IHND/4.49. CONCLUSION: It was concluded that the ICoW and IAW measurements are the only predictable methods to estimate the initial reference value for CATW. A proposed intraoral approach was hypothesized for estimation of CIW and CIL for the given population. CLINICAL SIGNIFICANCE: Based on the results of the study, ICoW and IAW measurements can be useful in estimating the initial reference value for CATW, while the proposed novel approach using specific palatal dimensions can be used for estimating the width and length of central incisors. These methods are crucial to obtain esthetic treatment results within the parameters of the given population.


Assuntos
Incisivo/anatomia & histologia , Maxila/anatomia & histologia , Adulto , Estética Dentária , Face/anatomia & histologia , Feminino , Humanos , Arcada Edêntula , Masculino , Arábia Saudita , Adulto Jovem
13.
Int J Prosthodont ; 0(0): 1-24, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38466574

RESUMO

PURPOSE: To develop a system for assessment of the status of a tooth to receive a full coverage crown and depict it on a measurable scale, and to validate its use by assessing examiner reproducibility. METHODS: The index was developed based on the inputs from experts in the field with a consensus on factors (4 periodontal, 2 endodontic, and 4 prosthodontic), stages of severity (stage 1 to stage 4), assigned scores, and relative weights pertaining to varied clinical scenarios. Based on the selection of factor-stage combination, an overall tooth crownability index (TCI) score along with three-factor scores were computed. The validation study included clinical and radiological assessment of cases based on the index criteria by four independent examiners (periodontist, prosthodontist, endodontist, and general practitioner). RESULTS: Forty teeth were assessed. The distribution of repeated selection by the examiners was quite identical to the initial (kappa = 0.93). There was no statistically significant difference in the mean scores of examiners in TCI and factorial scores. An excellent agreement between the measurements was observed among the examiners (ICC =0.993; Crohnbach α = 0.993). CONCLUSIONS: A tooth crownability index has been developed for a tooth to receive a full coverage crown which has an excellent agreement and good reproducibility among the examiners. TCI will serve as a baseline tool in treatment plan decision-making based on the status of the teeth and in research for evaluating the efficacy of various treatment options available (standard criteria for outcome assessment).

14.
Int J Health Sci (Qassim) ; 18(4): 58-69, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38974649

RESUMO

Objectives: Dental implant procedures are crucial for replacing missing teeth, with various surgical techniques impacting the outcome. This systematic review and meta-analysis aimed to evaluate the effects of flapped and flapless surgical techniques on implant survival and marginal bone loss (MBL). Methods: We included clinical studies with at least ten subjects, excluding review articles, editorials, and conference abstracts. Studies were sourced from PubMed, Medline, ERIC, and Wiley, published between 2000 and 2022. Data were analyzed using random-effects models to compare implant survival and MBL between flapped and flapless techniques. Results: The review identified 21 studies meeting the inclusion criteria. Flapless techniques showed a higher implant survival rate with an approximate survival rate of 98.6% in prospective cohort studies and 95.9% in retrospective studies. MBL was consistently lower in the flapless group, averaging 0.6-2.1 mm, compared to 1.5-3 mm in the flapped group. Low-risk studies demonstrated more consistent and reliable results, supporting the efficacy of flapless procedures. Conclusion: Flapless implant surgery offers a viable alternative to traditional flapped surgery, showing higher rates of implant survival and less MBL. However, successful outcomes depend on advanced imaging, precise surgical techniques, and adequate training. Further high-quality studies are needed to confirm these findings and refine clinical recommendations.

15.
Technol Health Care ; 32(1): 343-359, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37125591

RESUMO

BACKGROUND: Various studies have been conducted to analyze data via bibliometric analysis in different dentistry, including prosthetic dentistry. However, these studies evaluated the most cited published articles in dentistry. OBJECTIVE: To analyze and evaluate the characteristic development of several mesh keywords in the Journal of Prosthodontics - Implant, Esthetic, and Reconstructive Dentistry between 1992 and 2022. METHODS: The Scopus databases was searched to retrieve the data related to 8 categories, including published articles, most cited documents, authors and organizations, and maximum articles cited during the evaluation period. The data retrieved were exported to a Microsoft Excel sheet and were analyzed using the bibliometrix package. The data were first analyzed for ten years and then for 30 years. The highest of 10 were reported for each category, and co-authorship, reoccurrence, and linked data were also reported. RESULTS: 2603 published documents were recorded from the Scopus databases. Articles comprised 87.9% of the total published work, followed by review articles at 5.46%. The most productive decade was between 2013 and 2022. 3793 terms were used during the evaluation period, with the maximum number in 2003-2012 (2481). A total of 5392 keywords were used during 1992-2022, with the highest number (3232) from 2013 to 2022. A total of 6108 authors were acknowledged, with the maximum number (3964) from 2013 to 2022 and the fewest (767) from 1992 to 2002. Authors from different countries increased from 17 countries in 1992-2002 to 52 countries in 2013-2022 (total = 63 countries). Similarly, the number of organizations increased from 312 organizations in 1992-2002 to 1315 organizations in 2013-2022 (total = 1976 organizations). CONCLUSION: The current bibliometric analysis delivered a comprehensive overview about more spread research topics and its impactful role in contemporary dentistry, especially prosthetic dentistry.


Assuntos
Odontologia , Prostodontia , Bibliometria , Estética , Publicações Periódicas como Assunto
16.
J Prosthet Dent ; 109(2): 129-34, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23395339

RESUMO

Several studies have been published on the neutral zone regarding materials, techniques, and different prostheses; however, the data are incongruent, and a literature review was necessary. This review summarizes the literature on the neutral zone and identifies deficiencies suggesting future research. The English language peer-reviewed dental literature was reviewed from the period January 1, 1900 to June 30, 2011. Articles were searched in Medline (PubMed) and Google scholar for the term "neutral zone" and were supplemented by a hand search in prosthodontic publications. Deficiencies in the literature were found, including materials and techniques for recording the neutral zone, the comparison of different neutral zone dentures, and the effect of the period of edentulism on the neutral zone.


Assuntos
Bochecha/anatomia & histologia , Planejamento de Dentadura , Prótese Total , Lábio/anatomia & histologia , Língua/anatomia & histologia , Humanos
17.
Cureus ; 15(7): e41694, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37575741

RESUMO

Diagnosing dental caries plays a pivotal role in preventing and treating tooth decay. However, traditional methods of diagnosing caries often fall short in accuracy and efficiency. Despite the endorsement of radiography as a diagnostic tool, the identification of dental caries through radiographic images can be influenced by individual interpretation. Incorporating artificial intelligence (AI) into diagnosing dental caries holds significant promise, potentially enhancing the precision and efficiency of diagnoses. This review introduces the fundamental concepts of AI, including machine learning and deep learning algorithms, and emphasizes their relevance and potential contributions to the diagnosis of dental caries. It further explains the process of gathering and pre-processing radiography data for AI examination. Additionally, AI techniques for dental caries diagnosis are explored, focusing on image processing, analysis, and classification models for predicting caries risk and severity. Deep learning applications in dental caries diagnosis using convolutional neural networks are presented. Furthermore, the integration of AI systems into dental practice is discussed, including the challenges and considerations for implementation as well as ethical and legal aspects. The breadth of AI technologies and their prospective utility in clinical scenarios for diagnosing dental caries from dental radiographs is presented. This review outlines the advancements of AI and its potential in revolutionizing dental caries diagnosis, encouraging further research and development in this rapidly evolving field.

18.
Materials (Basel) ; 15(11)2022 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-35683165

RESUMO

CAD/CAM technology is gaining popularity and replacing archaic conventional procedures for fabricating dentures. CAD/CAM supports using a digital workflow reduce the number of visits, chair time, and laboratory time, making it attractive to patients. This study aimed to provide a comparative review of complete dentures manufactured using CAD/CAM and conventional methods. The PubMed/Medline, Science Direct, Cochrane, and Google Scholar databases were searched for studies published in English within the last 11 years (from 2011 to 2021). The keywords used were "computer-engineered complete dentures", "CAD/CAM complete dentures", "computer-aided engineering complete dentures", and "digital complete dentures". The search yielded 102 articles. Eighteen relevant articles were included in this review. Overall, computer-engineered complete dentures have several advantages over conventional dentures. Patients reported greater satisfaction with computer-engineered complete dentures (CECDs) due to better fit, reduced chair time, shorter appointments, and fewer post-insertion visits. CAD/CAM allows for precision and reproducibility with fewer procedures compared to conventional dentures. Polymethyl methacrylate is used as the denture base material for conventional dentures. For CECDs, the resin can be modified and cross-linked to improve its mechanical properties. The advantages of CECDs include a reduced number of appointments, saving chairside time, a digital workflow allowing easy reproducibility and greater patient satisfaction with a better fit.

19.
Saudi J Biol Sci ; 29(1): 622-629, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35002459

RESUMO

OBJECTIVES: Peri-implantitis is a destructive inflammatory process that affects the soft and hard tissues around dental implants. porphyromonas gingivalis, an anaerobic gram-negative bacterium, appears to be the main culprit. Since there is no efficient and specific vaccine to treat peri-implantitis, the goal of our research has been to develop a multi-epitope vaccination utilizing an immunoinformatics approach that targeted P. gingivalis type I fim A. MATERIALS AND METHODS: P. gingivalis peptides 6JKZ and 6KMF are suitable for vaccine development. B- and T-cell epitopes from 6KMF and 6JKZ were detected and evaluated based on critical factors to produce a multi-epitope vaccine construct. It was assessed based on allergenicity, antigenicity, stability. The vaccine's dual major histocompatibility complex (MHC-I and MHC-II) binding epitopes allowed it to reach a larger population. P. gingivalis fimbriae induce immune subversion through TLR -CXCR4 receptor complex pathway. The ClusPro 2.0 server was used to do the molecular docking using TLR2 - CXCR4 and vaccine epitopes as receptor and ligand respectively. RESULTS: The designed vaccine was non-allergenic and had a high antigenicity, solubility, and stability. The 3D structure of the vaccine revealed strong interaction with CXCR4(TLR2) using molecular docking. The vaccine-CXCR4 interface was more consistent, possibly because the vaccination has a higher affinity for the CXCR4-TLR2 complex. CONCLUSION: This study details the vaccine's distinct and sustained interaction with the CXCR4(TLR2) immunological receptor and its consistent and effective utterance in the bacterial system. As a result, our vaccine formulation will evoke a significant memory response and induce an adaptive immune response against P. gingivalis.

20.
Biomimetics (Basel) ; 7(2)2022 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-35466260

RESUMO

The goal of the study was to evaluate marginal bone loss (MBL) after 1-year implant placement using a guided implant surgical (GIS) protocol in grafted sockets compared to non-grafted sites. We followed a parallel study design with patients divided into two groups: grafted group (Test group, n = 10) and non-grafted group (Control, n = 10). A bioactive glass bone graft was used for grafting. A single edentulous site with a minimum bone height ≥11 mm and bone width ≥6 mm confirmed by cone-beam computerized tomography (CBCT) was chosen for implant placement. Tapered hybrid implants that were sandblasted and acid-etched (HSA) were placed using the GIS protocol and immediately loaded with a provisional prosthesis. MBL and implant survival rates (ISR) were assessed based on standardized radiographs and clinical exams. Patients were followed up for 1-year post-loading. MBL after one year, in the control group, was −0.31 ± 0.11 mm (mesial) and −0.28 ± 0.09 mm (distal); and in the test group was −0.35 ± 0.11 mm (mesial) and −0.33 ± 0.13 mm (distal), with no statistical significance (p > 0.05). ISR was 100% in both groups after one year. ISR was similar between groups and the marginal bone changes were comparable one year after functional loading, without statistical significance, suggesting that bioactive glass permitted adequate bone formation. The GIS protocol avoided raising flaps and provided a better position to place implants, preserving the marginal bone around implants.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA