Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Clin Oral Implants Res ; 35(4): 427-442, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38314615

RESUMO

OBJECTIVE: This study aimed to synthesize zinc-incorporated nanowires structure modified titanium implant surface (Zn-NW-Ti) and explore its superior osteogenic and antibacterial properties in vitro and in vivo. MATERIALS AND METHODS: Zn-NW-Ti was synthesized via displacement reactions between zinc sulfate solutions and the titanium (Ti) surface, which was pretreated by hydrofluoric acid etching and hyperthermal alkalinization. The physicochemical properties of the Zn-NW-Ti surface were examined. Moreover, the biological effects of Zn-NW-Ti on MC3T3-E1 cells and its antibacterial property against oral pathogenic bacteria (Staphylococcus aureus, Porphyromonas gingivalis, and Actinobacillus actinomycetemcomitans) compared with sandblasted and acid-etched Ti (SLA-Ti) and nanowires modified Ti (NW-Ti) surface were assessed. Zn-NW-Ti and SLA-Ti modified implants were inserted into the anterior extraction socket of the rabbit mandible with or without exposure to the mixed bacterial solution (S. aureus, P. gingivalis, and A. actinomycetemcomitans) to investigate the osteointegration and antibacterial performance via radiographic and histomorphometric analysis. RESULTS: The Zn-NW-Ti surface was successfully prepared. The resultant titanium surface appeared as a nanowires structure with hydrophilicity, from which zinc ions were released in an effective concentration range. The Zn-NW-Ti surface performed better in facilitating the adhesion, proliferation, and differentiation of MC3T3-E1 cells while inhibiting the colonization of bacteria compared with SLA-Ti and NW-Ti surface. The Zn-NW-Ti implant exhibited enhanced osseointegration in vivo, which was attributed to increased osteogenic activity and reduced bacterial-induced inflammation compared with the SLA-Ti implant. CONCLUSIONS: The Zn-incorporated nanowires structure modified titanium implant surface exhibited improvements in osteogenic and antibacterial properties, which optimized osteointegration in comparison with SLA titanium implant surface.


Assuntos
Implantes Dentários , Nanofios , Animais , Coelhos , Titânio/farmacologia , Titânio/química , Staphylococcus aureus , Antibacterianos/farmacologia , Osseointegração , Bactérias , Zinco/química , Zinco/farmacologia , Propriedades de Superfície , Osteogênese
2.
J Prosthet Dent ; 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38278668

RESUMO

STATEMENT OF PROBLEM: Research has revealed that the crown-implant ratio (CIR) is a critical variable influencing the long-term stability of implant-supported prostheses in the oral cavity. Nevertheless, inefficient manual measurement and varied measurement methods have caused significant inconvenience in both clinical and scientific work. PURPOSE: This study aimed to develop an automated system for detecting the CIR of implant-supported prostheses from radiographs, with the objective of enhancing the efficiency of radiograph interpretation for dentists. MATERIAL AND METHODS: The method for measuring the CIR of implant-supported prostheses was based on convolutional neural networks (CNNs) and was designed to recognize implant-supported prostheses and identify key points around it. The experiment used the You Only Look Once version 4 (Yolov4) to locate the implant-supported prosthesis using a rectangular frame. Subsequently, two CNNs were used to identify key points. The first CNN determined the general position of the feature points, while the second CNN finetuned the output of the first network to precisely locate the key points. The network underwent testing on a self-built dataset, and the anatomic CIR and clinical CIR were obtained simultaneously through the vertical distance method. Key point accuracy was validated through Normalized Error (NE) values, and a set of data was selected to compare machine and manual measurement results. For statistical analysis, the paired t test was applied (α=.05). RESULTS: A dataset comprising 1106 images was constructed. The integration of multiple networks demonstrated satisfactory recognition of implant-supported prostheses and their surrounding key points. The average NE value for key points indicated a high level of accuracy. Statistical studies confirmed no significant difference in the crown-implant ratio between machine and manual measurement results (P>.05). CONCLUSIONS: Machine learning proved effective in identifying implant-supported prostheses and detecting their crown-implant ratios. If applied as a clinical tool for analyzing radiographs, this research can assist dentists in efficiently and accurately obtaining crown-implant ratio results.

3.
J Sep Sci ; 44(2): 636-644, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33216431

RESUMO

Polyethyleneimine-modified magnetic multi-walled carbon nanotubes were developed to extract 10 mycotoxins. Simple modification of polyethyleneimine was achieved on the magnetic substrate by using an epoxy-containing silane agent as a linker. The resultant magnetic adsorbent was integrated with reverse phase and anion exchange interaction sites. Under optimal extraction conditions, only 20.0 mg adsorbent was used to extract the mycotoxins from 50.0 mL loading solution. The maximum adsorption capacities of the adsorbent toward the mycotoxins ranged from 4.9 to 10.2 mg/g. Adsorption and desorption were completed within 3.0 and 2.0 min, respectively. The adsorbent could be used for six repeated runs without evident change in extraction performance. The adsorbent combined with liquid chromatography-tandem mass spectrometry was applied further to analyze the mycotoxins in milk. The absolute recoveries of the 10 mycotoxins ranged from 88.3 to 103.5% with relative standard deviations that ranged from 2.4 to 6.5%, and their limits of detection were 0.003 to 0.442 µg/kg. The proposed adsorbent has great potential in the routine analysis of mycotoxins in ordinary analytical chemistry laboratory.


Assuntos
Contaminação de Alimentos/análise , Leite/química , Micotoxinas/análise , Nanotubos de Carbono/química , Polietilenoimina/química , Extração em Fase Sólida , Adsorção , Animais , Cromatografia Líquida , Fenômenos Magnéticos , Tamanho da Partícula , Espectrometria de Massas em Tandem
4.
Mikrochim Acta ; 187(12): 648, 2020 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-33165743

RESUMO

An amphiphilic block copolymer consisting of poly(N-acryloyl-glucosamine) (PAGA) and poly(tert-butyl methacrylate) (PtBMA) was designed and grafted on magnetic multi-walled carbon nanotubes (Fe3O4MWCNTs). The resultant Fe3O4MWCNTs@copolymer was proposed as QuEChERS adsorbent for determination of 15 mycotoxins and 25 pesticides in grains via liquid chromatography tandem mass spectrometry. The adsorbent was characterized by a transmission electron microscope, scanning electron microscope, elemental analysis, and other techniques. The common matrix interferences were efficiently removed by the proposed adsorbent, such as pigment, fatty acids, and the saccharide. PAGA segment played an important role in removing the hydrophilic interferences through hydrogen bonding due to the high density of hydroxyl groups. PtBMA segment removed the fatty residues through its strong hydrophobic carbon moiety. In comparison with the commercially available QuEChERS adsorbents, the proposed adsorbent had higher adsorption capacities towards the typical matrix interferences. To achieve satisfactory recoveries of analytes, various parameters in the QuEChERS procedure were comprehensively investigated. Under the optimal conditions, 95.0% of the analytes showed satisfactory recoveries in the range 70.0-120% as well as negligible matrix effects. The limits of detection (LOD) were in the range 0.00015-1.3 µg kg-1. Compared with previously reported QuEChERS methods, the proposed method had improved sensitivity and benefited from low matrix effects. The recoveries of analytes in various grains were in the range 60.8-108% with relative standard deviations (RSD) less than 13%. Moreover, the Fe3O4MWCNTs@copolymer exhibited good synthetic reproducibility and rapid magnetic separation (less than 10 s). The research provides a versatile platform to develop multi-functional QuEChERS adsorbents based on the amphiphilic block copolymer.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Grão Comestível/química , Contaminação de Alimentos/análise , Magnetismo , Micotoxinas/análise , Nanotubos de Carbono/química , Praguicidas/análise , Polímeros/química , Espectrometria de Massas em Tandem/métodos , Adsorção , Limite de Detecção , Reprodutibilidade dos Testes
5.
Clin Oral Implants Res ; 30(10): 1038-1048, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31348555

RESUMO

OBJECTIVE: This study aims to investigate the influence of fluoride exposure on implant osseointegration. METHODS: A total of 24 male New Zealand white rabbits were randomly divided into the control group and the fluoride exposure group. Rabbits in the control group were fed with tap water, while those in the fluoride exposure group were given 200 mg/L sodium fluoride solution. After 2-month feeding, implants were inserted into the extraction socket immediately after extraction of rabbit mandibular anterior teeth. Four rabbits in each group were sacrificed to collect the implants samples at 1, 2, and 3 months post-implantation, respectively. Radiographic and histomorphometry examinations were performed to evaluate the condition of implant osseointegration. RESULTS: Bone volume around the implants increased in a time-dependent manner in both groups. Micro-CT images illustrated that the bone mineral density (BMD) in the fluoride exposure group was significantly lower than that in the control group after implantation for 2 and 3 months. The bone-implant contact ratio (BIC) in the fluoride exposure group was much lower than that of the control group at 3 months post-implantation according to histomorphometry examination. CONCLUSIONS: In rabbit animal model, high fluoride exposure affected the quality of bone surrounding the implant and significantly reduced bone integration of the implant, especially in the late stage of osseointegration.


Assuntos
Implantes Dentários , Osseointegração , Animais , Fluoretos , Masculino , Coelhos , Titânio , Microtomografia por Raio-X
6.
J Nanobiotechnology ; 17(1): 55, 2019 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-30992009

RESUMO

Titanium (Ti) and its alloys as bio-implants have excellent biocompatibilities and osteogenic properties after modification of chemical composition and topography via various methods. The corrosion resistance of these modified materials is of great importance for changing oral system, while few researches have reported this point. Recently, oxidative corrosion induced by cellular metabolites has been well concerned. In this study, we explored the corrosion behaviors of four common materials (commercially pure Ti, cp-Ti; Sandblasting and acid etching-modified Ti, Ti-SLA; nanowires-modified Ti, Ti-NW; and zinc-containing nanowires-modified Ti, Ti-NW-Zn) with excellent biocompatibilities and osteogenic capacities under the macrophages induced-oxidizing microenvironment. The results showed that the materials immersed into a high oxidizing environment were more vulnerable to corrode. Meanwhile, different surfaces also showed various corrosion susceptibilities under oxidizing condition. Samples embed with zinc element exhibited more excellent corrosion resistance compared with other three surfaces exposure to excessive H2O2. Besides, we found that zinc-decorated Ti surfaces inhibited the adhesion and proliferation of macrophages on its surface and induced the M2 states of macrophages to better healing and tissue reconstruction. Most importantly, zinc-decorated Ti surfaces markedly increased the expressions of antioxidant enzyme relative genes in macrophages. It improved the oxidation microenvironment around the materials and further protected their properties. In summary, our results demonstrated that Ti-NW-Zn surfaces not only provided excellent corrosion resistance properties, but also inhibited the adhesion of macrophages. These aspects were necessary for maintaining osseointegration capacity and enhancing the corrosion resistance of Ti in numerous medical applications, particularly in dentistry.


Assuntos
Peróxido de Hidrogênio/química , Nanofios/química , Titânio/química , Zinco/química , Animais , Materiais Biocompatíveis , Adesão Celular , Linhagem Celular , Proliferação de Células , Corrosão , Implantes Dentários , Macrófagos/metabolismo , Camundongos , Oxirredução , Propriedades de Superfície
7.
J Appl Toxicol ; 38(6): 824-833, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29377205

RESUMO

Titanium (Ti) and its corresponding alloys have been widely applied in dental and orthopedic implants. Owing to abrasion and corrosion of implants in the unfavorable electrolytic aqueous environment of the host body, Ti ions could be released from implants and accumulated in local tissues. Recent studies have found that excessive Ti ions were toxic to osteoblasts in adjacent bone tissues and subsequently influenced long-term effects on implant prostheses. However, the potential molecular mechanisms underlying the damage to osteoblasts induced by Ti ions remained unclear. Hippo signaling has been confirmed to be involved in organ size and tissue regeneration in many organs, while its roles in osteoblasts differentiation and bone repair remained elusive. Therefore, we hypothesize that YAP, a regulator of Hippo pathway, inhibited osteoblast growth, skeletal development and bone repair, as well as excessive Ti ions promoted the progression of YAP activation. This study aimed to explore the role of Hippo/YAP signaling pathway in the biotoxicity effect of Ti ions on osteoblast behaviors. Here, we confirmed that 10 ppm Ti ions, a minimum concentration gradient previously reported that was capable of suppressing osteoblasts growth, induced nuclear expression of YAP in osteoblasts in our study. Furthermore, 10 ppm Ti ion-induced YAP activation was found to downregulate osteogenic differentiation of MC3T3-E1 cells. Most importantly, the hypothesis we proposed that knockdown of YAP did reverse the inhibitory effect of 10 ppm Ti ions on osteogenesis has been verified. Taken together, our work provides insights into the mechanism of which YAP is involved in regulating osteoblast behaviors under the effect of Ti ions, which may help to develop therapeutic applications for Ti implant failures and peri-implantitis.


Assuntos
Proteínas Adaptadoras de Transdução de Sinal/metabolismo , Proteínas de Ciclo Celular/metabolismo , Osteoblastos/efeitos dos fármacos , Proteínas Serina-Treonina Quinases/metabolismo , Transdução de Sinais/efeitos dos fármacos , Titânio/toxicidade , Células 3T3 , Proteínas Adaptadoras de Transdução de Sinal/genética , Animais , Proteínas de Ciclo Celular/genética , Diferenciação Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Regulação da Expressão Gênica , Via de Sinalização Hippo , Camundongos , Osteoblastos/metabolismo , Osteoblastos/patologia , Osteogênese/efeitos dos fármacos , Osteogênese/genética , Fosforilação , Proteínas de Sinalização YAP
8.
J Mater Sci Mater Med ; 27(4): 78, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26896953

RESUMO

Corrosion of dental alloys is a major concern in dental restorations. Streptococcus mutans reduces the pH in oral cavity and induces demineralization of the enamel as well as corrosion of restorative dental materials. The rough surfaces of dental alloys induced by corrosion enhance the subsequent accumulation of plaque. In this study, the corrosion process of nickel-chromium (Ni-Cr) and cobalt-chromium (Co-Cr) alloys in a nutrient-rich medium containing S. mutans was studied using inductively coupled plasma atomic emission spectrometry (ICP-AES), X-ray photoelectron spectroscopy (XPS) and electrochemical corrosion test. Our results showed that the release of Ni and Co ions increased, particularly after incubation for 3 days. The electrochemical corrosion results showed a significant decrease in the corrosion resistance (Rp) value after the alloys were immersed in the media containing S. mutans for 3 days. Correspondingly, XPS revealed a reduction in the relative dominance of Ni, Co, and Cr in the surface oxides after the alloys were immersed in the S. mutans culture. After removal of the biofilm, the pre-corroded alloys were re-incubated in S. mutans medium, and the expressions of genes associated with the adhesion and acidogenesis of S. mutans, including gtfBCD, gbpB, fif and ldh, were evaluated by detecting the mRNA levels using real-time reverse transcription polymerase chain reaction (RT-PCR). We found that the gtfBCD, gbpB, ftf and Idh expression of S. mutans were noticeably increased after incubation with pre-corroded alloys for 24 h. This study demonstrated that S. mutans enhanced the corrosion behavior of the dental alloys, on the other hand, the presence of corroded alloy surfaces up-regulated the virulent gene expression in S. mutans. Compared with smooth surfaces, the rough corroded surfaces of dental alloys accelerated the bacteria-adhesion and corrosion process by changing the virulence gene expression of S. mutans.


Assuntos
Ligas de Cromo/química , Regulação Bacteriana da Expressão Gênica/fisiologia , Streptococcus mutans/metabolismo , Biofilmes/crescimento & desenvolvimento , Corrosão , Técnicas Eletroquímicas , Metais/química , Reação em Cadeia da Polimerase em Tempo Real , Streptococcus mutans/fisiologia , Propriedades de Superfície , Fatores de Tempo
9.
Chirality ; 27(1): 32-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25331721

RESUMO

The enantiomeric separation of eight pesticides including bitertanol (), diclobutrazol (), fenbuconazole (), triticonazole (), imazalil (), triapenthenol (), ancymidol (), and carfentrazone-ethyl () was achieved, using normal-phase high-performance liquid chromatography on two cellulosed-based chiral columns. The effects of isopropanol composition from 2% to 30% in the mobile phase and column temperature from 5 to 40 °C were investigated. Satisfactory resolutions were obtained for bitertanol (), triticonazole (), imazalil () with the (+)-enantiomer eluted first and fenbuconazole () with the (-)-enantiomer eluted first on Lux Cellulose-2 and Lux Cellulose-3. (+)-Enantiomers of diclobutrazol () and triapenthenol () were first eluted on Lux Cellulose-2. (-)-Carfentrazone-ethyl () were eluted first on Lux Cellulose-2 and Lux Cellulose-3 with incomplete separation. Reversed elution orders were obtained for ancymidol (7). (+)-Ancymidol was first eluted on Lux Cellulose-2 while on Lux Cellulose-3 (-)-ancymidol was first eluted. The results of the elution order at different column temperatures suggested that column temperature did not affect the optical signals of the enantiomers. These results will be helpful to prepare and analyze individual enantiomers of chiral pesticides.


Assuntos
Celulose/química , Cromatografia Líquida de Alta Pressão , Compostos Heterocíclicos/análise , Nitrogênio/química , Praguicidas/análise , Compostos Heterocíclicos/química , Estrutura Molecular , Estereoisomerismo
10.
Colloids Surf B Biointerfaces ; 240: 113966, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38781846

RESUMO

Dental Implants are expected to possess both excellent osteointegration and antibacterial activity because poor osseointegration and infection are two major causes of titanium implant failure. In this study, we constructed layer-by-layer self-assembly films consisting of anionic casein phosphopeptides-amorphous calcium phosphate (CPP-ACP) and cationic poly (L-lysine) (PLL) on sandblasted and acid etched (SLA) titanium surfaces and evaluated their osseointegration and antibacterial performance in vitro and in vivo. The surface properties were examined, including microstructure, elemental composition, wettability, and Ca2+ ion release. The impact the surfaces had on the adhesion, proliferation and differentiation abilities of MC3T3-E1 cells were investigated, as well as the material's antibacterial performance after exposure to the oral microorganisms such as Porphyromonas gingivalis (P. g) and Actinobacillus actinomycetemcomitans (A. a). For the in vivo studies, SLA and Ti (PLL/CA-3.0)10 implants were inserted into the extraction socket immediately after extracting the rabbit mandibular anterior teeth with or without exposure to mixed bacteria solution (P. g & A. a). Three rabbits in each group were sacrificed to collect samples at 2, 4, and 6 weeks of post-implantation, respectively. Radiographic and histomorphometry examinations were performed to evaluate the implant osseointegration. The modified titanium surfaces were successfully prepared and appeared as a compact nano-structure with high hydrophilicity. In particular, the Ti (PLL/CA-3.0)10 surface was able to continuously release Ca2+ ions. From the in vitro and in vivo studies, the modified titanium surfaces expressed enhanced osteogenic and antibacterial properties. Hence, the PLL/CPP-ACP multilayer coating on titanium surfaces was constructed via a layer-by-layer self-assembly technology, possibly improving the biofunctionalization of Ti-based dental implants.


Assuntos
Antibacterianos , Osseointegração , Polilisina , Propriedades de Superfície , Titânio , Titânio/química , Titânio/farmacologia , Osseointegração/efeitos dos fármacos , Animais , Polilisina/química , Polilisina/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Camundongos , Implantes Dentários/microbiologia , Coelhos , Porphyromonas gingivalis/efeitos dos fármacos , Caseínas/química , Caseínas/farmacologia , Proliferação de Células/efeitos dos fármacos , Aggregatibacter actinomycetemcomitans/efeitos dos fármacos , Testes de Sensibilidade Microbiana , Adesão Celular/efeitos dos fármacos , Diferenciação Celular/efeitos dos fármacos , Fosfatos de Cálcio
11.
Microbiol Spectr ; : e0367923, 2024 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-39240122

RESUMO

Bacterial biofilms are the major etiology agent of peri-implant disease. Chemical decontamination is a promising treatment strategy against bacterial biofilms; however, its applications are limited by its low efficiency and poor biocompatibility. In contrast to three conventional cleaners (sterile saline, hydrogen peroxide, and chlorhexidine), this study used resveratrol and naringin solutions to remove mature Staphylococcus aureus and Porphyromonas gingivalis biofilm on sandblasted (with large grit and acid-etched (SLA) titanium surface. To determine changes in surface characteristics, the surface wettability and roughness were measured, and micromorphology was observed by scanning electron microscopy. With crystal violet (CV) and live/dead bacterial staining, residual plaque quantity and composition were measured. The biocompatibility was tested using pH and cytotoxicity, as well as by osteoblasts (MC3T3-E1) adhesion, proliferation, and differentiation, and fibroblasts (L-929) proliferation were also analyzed. It was found that resveratrol and naringin solutions were more effective in restoring surface characteristics and also showed that less plaque and viable bacteria were left. Naringin removed S. aureus biofilms better than chlorhexidine. Alkaline resveratrol and naringin solutions increased cell adhesion, proliferation, and osteogenic differentiation without any cytotoxicity. Resveratrol increased the expression of mRNA and protein associated with osteogenesis. In conclusion, resveratrol and naringin effectively restored SLA titanium surface characteristics and decontaminated the biofilm with good biocompatibility, suggesting their therapeutic potential as chemical decontaminants. IMPORTANCE: Bacterial biofilms are considered the primary etiology of peri-implant disease. Physical cleaning is the most common way to remove bacterial biofilm, but it can cause grooving, melting, and deposition of chemicals that alter the surface of implants, which may hamper biocompatibility and re-osseointegration. Chemical decontamination is one of the most promising treatments but is limited by low efficiency and poor biocompatibility. Our study aims to develop safer, more effective chemical decontaminants for peri-implant disease prevention and treatment. We focus on resveratrol and naringin, two natural compounds, which have shown to be more effective in decontaminating biofilms on dental implant surfaces and exerting better biocompatibility. This research is groundbreaking as it is the first exploration of natural plant extracts' impact on mature bacterial biofilms on rough titanium surfaces. By advancing this knowledge, we seek to contribute to more effective and biocompatible strategies for combating peri-implant diseases, enhancing oral health, and prolonging implant lifespan.

12.
Colloids Surf B Biointerfaces ; 234: 113691, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38070369

RESUMO

SEMA4D-modified titanium surfaces can indirectly regulate macrophages through endothelial cells to achieve an anti-inflammatory effect, which is beneficial for healing soft tissues around the gingival abutment. However, the mechanism of surface-induced cellular phenotypic changes in SEMA4D-modified titanium has not yet been elucidated. SEMA4D activates the RhoA signaling pathway in endothelial cells, which coordinates metabolism and cytoskeletal remodeling. This study hypothesized that endothelial cells inoculated on SEMA4D-modified titanium surfaces can direct M2 polarization of macrophages via metabolites. An indirect co-culture model of endothelial cells and macrophages was constructed in vitro, and specific inhibitors were employed. Subsequently, endothelial cell adhesion and migration, metabolic changes, Rho/ROCK1 expression, and inflammatory expression of macrophages were assessed via immunofluorescence microscopy, specific kits, qRT-PCR, and Western blotting. Moreover, an in vivo rat bilateral maxillary implant model was constructed to evaluate the soft tissue healing effect. The in vitro experiments showed that the SEMA4D group had stronger endothelial cell adhesion and migration, increased Rho/ROCK1 expression, and enhanced release of lactate. Additionally, decreased macrophage inflammatory expression was observed. In contrast, the inhibitor group partially suppressed lactate metabolism and motility, whereas increased inflammatory expression. The in vivo analyses indicated that the SEMA4D group had faster and better angiogenic and anti-inflammatory effects, especially in the early stage. In conclusion, via the Rho/ROCK1 signaling pathway, the SEMA4D-modified titanium surface promotes endothelial cell adhesion and migration and lactic acid release, then the paracrine lactic acid promotes the polarization of macrophages to M2, thus obtaining the dual effects of angiogenesis and anti-inflammation.


Assuntos
Antígenos CD , Células Endoteliais , Semaforinas , Titânio , Ratos , Animais , Titânio/farmacologia , Ácido Láctico , Macrófagos , Anti-Inflamatórios
13.
J Mater Sci Mater Med ; 24(5): 1229-37, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23430335

RESUMO

It is well known that some microorganisms affect the corrosion of dental metal. Oral bacteria such as Actinomyces naeslundii may alter the corrosion behavior and stability of titanium. In this study, the corrosion behavior of titanium was studied in a nutrient-rich medium both in the presence and the absence of A. naeslundii using scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and electrochemical impedance spectroscopy (EIS). A. naeslundii was able to colonize the surface of titanium and then form a dense biofilm. The SEM images revealed the occurrence of micropitting corrosion on the metal surface after removal of the biofilm. The electrochemical corrosion results from EIS showed a significant decrease in the corrosion resistant (R(p)) value after immersing the metal in A. naeslundii culture for 3 days. Correspondingly, XPS revealed a reduction in the relative levels of titanium and oxygen and an obvious reduction of dominant titanium dioxide (TiO2) in the surface oxides after immersion of the metal in A. naeslundii culture. These results suggest that the metabolites produced by A. naeslundii can weaken the integrity and stability of the protective TiO2 in the surface oxides, which in turn decreases the corrosion resistance of titanium, resulting in increased corrosion of titanium immersed in A. naeslundii solution as a function of time.


Assuntos
Actinomyces/fisiologia , Titânio/química , Biofilmes/crescimento & desenvolvimento , Corrosão , Teste de Materiais , Microscopia Eletrônica de Varredura , Espectroscopia Fotoeletrônica , Propriedades de Superfície
14.
J Mater Sci Mater Med ; 24(11): 2519-28, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23881280

RESUMO

The aim of this study was to evaluate the effects of a simulated porcelain firing process on the surface, corrosion behavior and cell culture response of two nickel-chromium (Ni-Cr) dental alloys. A Be-free alloy and a Be-containing alloy were tested. Before porcelain firing, as-cast specimens were examined for surface composition using X-ray photoelectron spectroscopy and metallurgical phases using X-ray diffraction. Corrosion behaviors were evaluated using electrochemical impedance spectroscopy. 3T3 fibroblasts were cultured and exposed indirectly to specimens. MTT assays were counted after 3 and 6 days. The cell culture mediums exposed to specimens were analyzed for metal ion release. After porcelain firing, similar specimens were examined for the same properties. In both as-cast and fired conditions, the Be-free Ni-Cr alloy showed significantly more resistance to corrosion than the Be-containing Ni-Cr alloy, which exhibited BeNi phase. After porcelain firing, the corrosion resistance of the Be-free Ni-Cr alloy decreased statistically, corresponding with evident decreases of Cr and Ni oxides on the alloy surface. Also, the alloy's MTT assay decreased significantly corresponding with an obvious increase of Ni-ion release after the firing. For the Be-containing Ni-Cr alloy, the firing process led to increases of surface oxides and metallic Be, while its corrosion resistance and cell culture response were not significantly changed after porcelain firing. The results suggested that the corrosion resistance and biocompatibility of the Be-free Ni-Cr alloy decreased after porcelain firing, whereas the firing process had little effect on the same properties of the Be-containing Ni-Cr alloy.


Assuntos
Cromo , Corrosão , Ligas Dentárias , Porcelana Dentária/química , Espectroscopia Dielétrica/métodos , Níquel , Espectroscopia Fotoeletrônica/métodos , Células 3T3 , Animais , Camundongos , Propriedades de Superfície , Difração de Raios X
15.
Colloids Surf B Biointerfaces ; 224: 113217, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36868181

RESUMO

Osseointegration is a prerequisite for the function of dental implants, and macrophage-dominated immune responses triggered by implantation determine the outcome of ultimate bone healing mediated by osteogenic cells. The present study aimed to develop a modified titanium (Ti) surface by covalently immobilizing chitosan-stabilized selenium nanoparticles (CS-SeNPs) to sandblasted, large grit, and acid-etched (SLA) Ti substrates and further explore its surface characteristics as well as osteogenic and anti-inflammatory activities in vitro. CS-SeNPs were successfully prepared by chemical synthesis and characterized their morphology, elemental composition, particle size, and Zeta potential. Subsequently, three different concentrations of CS-SeNPs were loaded to SLA Ti substrates (Ti-Se1, Ti-Se5, and Ti-Se10) using a covalent coupling strategy, and the SLA Ti surface (Ti-SLA) was used as a control. Scanning electron microscopy images revealed different amounts of CS-SeNPs, and the roughness and wettability of Ti surfaces were less susceptible to Ti substrate pretreatment and CS-SeNP immobilization. Besides, X-ray photoelectron spectroscopy analysis showed that CS-SeNPs were successfully anchored to Ti surfaces. The results of in vitro study showed that the four as-prepared Ti surfaces exhibited good biocompatibility, with Ti-Se1 and Ti-Se5 groups showing enhanced adhesion and differentiation of MC3T3-E1 cells compared with the Ti-SLA group. In addition, Ti-Se1, Ti-Se5, and Ti-Se10 surfaces modulated the secretion of pro-/anti-inflammatory cytokines by inhibiting the nuclear factor kappa B pathway in Raw 264.7 cells. In conclusion, doping SLA Ti substrates with a modest amount of CS-SeNPs (1-5 mM) may be a promising strategy to improve the osteogenic and anti-inflammatory activities of Ti implants.


Assuntos
Quitosana , Nanopartículas , Selênio , Selênio/farmacologia , Titânio/farmacologia , Titânio/química , Quitosana/farmacologia , Propriedades de Superfície , Osteogênese , Anti-Inflamatórios/farmacologia
16.
Chirality ; 24(8): 628-33, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22581666

RESUMO

The enantioselective degradation of indoxacarb in cabbage and soil has been investigated in Beijing and Anhui under open conditions. Indoxacarb enantiomers in samples were extracted with acetonitrile, cleaned up by florisil SPE column, separated on high performance liquid chromatography with a cellulose-tris-(3, 5-dimethylphenylcarbamate)-based chiral stationary phase (CDMPC-CSP), and determined by a photodiode array detector. The validation of the developed method by fortification rac-indoxcarb in cabbage and soil showed good accuracy and precision. The results of field trials indicated that the dissipation of indoxacarb enantiomers followed pseudo-first-order kinetics or first-order kinetics in cabbage and soil at two locations. The half-lives of two enantiomers in cabbage ranged from 2.8 to 4.6 d which were shorter than those in soil ranging from 23 to 35 d. The changes of enantiomeric fraction values proved that enantioselective degradation of indoxacarb happened in cabbage and soil. The (-)-indoxacarb showed faster degradation in the Beijing cabbage, whereas in the Anhui cabbage, (+)-indoxacarb preferentially degraded. In soil, preferential degradation of (+)-indoxacarb was observed at two locations.


Assuntos
Brassica/metabolismo , Oxazinas/química , Oxazinas/metabolismo , Resíduos de Praguicidas/química , Resíduos de Praguicidas/metabolismo , Solo/química , Calibragem , Celulose/química , Cromatografia Líquida de Alta Pressão , Oxazinas/análise , Oxazinas/isolamento & purificação , Resíduos de Praguicidas/análise , Resíduos de Praguicidas/isolamento & purificação , Estereoisomerismo , Especificidade por Substrato
17.
J Mater Sci Mater Med ; 23(2): 527-36, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22143905

RESUMO

Recently, TiO(2) nanotube layers are widely used in orthopedics and dental applications because of their good promotion effect on bone cells. Furthermore, peptide sequences such as arginine-glycine-aspartic acid are used to modify Ti implant for binding to cell surface integrins through motif. In this study, a cellular adhesive peptide of arginine-glycine-aspartic acid-cysteine (RGDC) was immobilized onto anodized TiO(2) nanotubes on Ti to examine its in vitro responses on rat bone marrow stromal cells (BMSCs). Materials were characterized by scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy techniques. High-resolution C1s scans suggested the presence of RGDC on the surface and SEM images confirmed the nanotubes were not destroyed after modification. BMSCs adhesion and osteogenic gene expression were detected in TiO(2) nanotube layers with and without RGDC modification by fluorescence microscopy, confocal laser scanning microscopy, SEM, and realtime polymerase chain reaction (Real-time PCR). Results showed that the TiO(2) nanotube layers immobilized with RGDC increased BMSCs adhesion compared to nonfunctionalized nanotubes after 4 h of cultivation. Furthermore, the osteogenic gene expression of BMSCs was dramatically enhanced on the TiO(2) nanotube layers immobilized with RGDC (10 mM) compared to the TiO(2) nanotube layers immobilized with RGDC (1 mM) and non-functionalized anodized Ti. Our results from in vitro study provided evidence that Ti anodized to possess nanotubes and then further functionalized with RGDC should be further studied for the design of better biomedical implant surfaces.


Assuntos
Células da Medula Óssea/citologia , Nanopartículas Metálicas/química , Nanotecnologia/métodos , Nanotubos/química , Oligopeptídeos/química , Células Estromais/citologia , Titânio/química , Animais , Adesão Celular , Matriz Extracelular/metabolismo , Regulação da Expressão Gênica , Masculino , Microscopia Eletrônica de Varredura/métodos , Osteogênese , Peptídeos , Ratos , Ratos Wistar , Propriedades de Superfície
18.
Front Bioeng Biotechnol ; 10: 848769, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35528211

RESUMO

Zinc-modified titanium materials have been widely applied in oral implants. Among them, our previous studies have also successfully prepared a novel acid-etched microstructured titanium surface modified with zinc-containing nanowires (Ti-NW-Zn) and proved its excellent biocompatibility. It is well known that the functional regulation between angiogenesis and osteogenesis is of great importance for bone remodeling around implants. However, there are few reports concerning the biological safety of zinc ions released from materials and the appropriate concentration of released zinc ions which was more conducive to angiogenesis and bone regeneration. In this study, we investigated the effects of zinc ions released from Ti-NW-Zn surfaces on angiogenesis and osteogenesis using the zebrafish model and revealed the relationship between angiogenesis and osteogenesis via HUVECs and MC3T3-E1s in vitro. We found that the zinc ions released from Ti-NW-Zn surfaces, with a concentration lower than median lethal concentrations (LCs) of zebrafish, were biologically safe and promote osteogenesis and angiogenesis in vivo. Moreover, the proper concentration of zinc ions could induce the proliferation of HUVECs and osteogenic differentiation. The positive effects of the appropriate concentration of zinc ions on osteoblast behaviors might be regulated by activating the MAPK/ERK signaling pathway. These aspects may provide new sights into the mechanisms underlying zinc-modified titanium surfaces between osteogenesis and angiogenesis, to lay the foundation for further improving the materials, meanwhile, promoting the applications in dentistry.

19.
Eur J Oral Sci ; 119(1): 93-101, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21244518

RESUMO

This study evaluated the corrosion behaviour and surface properties of a commercial cobalt-chromium (Co-Cr) alloy and two nickel-chromium (Ni-Cr) alloys [beryllium (Be)-free and Be-containing] before and after a simulated porcelain-firing process. Before porcelain firing, the microstructure, surface composition and hardness, electrochemical corrosion properties, and metal-ion release of as-cast alloy specimens were examined. After firing, similar alloy specimens were examined for the same properties. In both as-cast and fired conditions, the Co-Cr alloy (Wirobond C) showed significantly more resistance to corrosion than the two Ni-Cr alloys. After firing, the corrosion rate of the Be-free Ni-Cr alloy (Stellite N9) increased significantly, which corresponded to a reduction in the levels of Cr, molybdenum (Mo), and Ni in the surface oxides and to a reduction in the thickness of the surface oxide film. The corrosion properties of the Co-Cr alloy and the Be-containing Ni-Cr alloy (ChangPing) were not significantly affected by the firing process. Porcelain firing also changed the microstructure and microhardness values of the alloys, and there were increases in the release of Co and Ni ions, especially for Ni from the Be-free Ni-Cr alloy. Thus, the corrosion rate of the Be-free Ni-Cr alloy increased significantly after porcelain firing, whereas the firing process had little effect on the corrosion susceptibility of the Co-Cr alloy and the Be-containing Ni-Cr alloy.


Assuntos
Ligas de Cromo/química , Técnica de Fundição Odontológica , Porcelana Dentária/química , Ligas Metalo-Cerâmicas/química , Berílio , Cobalto , Corrosão , Análise do Estresse Dentário , Dureza , Teste de Materiais , Molibdênio , Níquel , Óxidos , Espectroscopia Fotoeletrônica , Saliva Artificial , Propriedades de Superfície
20.
Regul Toxicol Pharmacol ; 61(1): 93-7, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21723903

RESUMO

The objective of the study was to obtain pharmacokinetic parameters for melamine and blend of melamine (MEL) and cyanuric acid (CYA) in rainbow trout (Oncorhynchus mykiss). The single target dosage of MEL (20mg/kg bw) and the blend of MEL and CYA (5 and 1.67 mg/kg bw, respectively) were designed and plasma samples were collected at 30 min, 1, 4, 8, 12, 20, 24, 36, 48, 72, 144 and 240 h sequentially. An optimized method for simultaneous determination of MEL and CYA in plasma and animal tissues by LC-MS/MS was used. The data were shown to best fit a non-compartment model with first order processes of linear characters for melamine, with half-life (t(½)) of 32.2-32.9h, clearance (Cl(z/F)) of 35.9-36.6 ml/h/kg, and volume of distribution (V(ss)) of 1.67-1.74 l/kg. Withdrawal of CYA was much more rapid than that of MEL with higher Cl(z/F) (783.56 ml/h/kg) and shorter t(½) (7.92 h). T(max) of MEL20 and MEL5 were 12 and 20 h, respectively, which showed that T(max) of MEL5 was delayed when MEL and CYA were given together. The results are quite different from those in mammals and showed much slower elimination of MEL and CYA from rainbow trout body.


Assuntos
Contaminação de Alimentos/análise , Oncorhynchus mykiss/metabolismo , Resinas Sintéticas/farmacocinética , Triazinas/farmacocinética , Administração Oral , Animais , Dieta , Distribuição Aleatória , Resinas Sintéticas/administração & dosagem , Resinas Sintéticas/análise , Triazinas/administração & dosagem , Triazinas/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA