1.
Ann Surg ; 237(6): 885-92; discussion 892-3, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12796586

RESUMO

OBJECTIVE: To compare the late clinical outcome and incidence of recurrent stenosis after carotid endarterectomy (CEA) with polytetrafluoroethylene (PTFE) versus Hemashield patching. SUMMARY BACKGROUND DATA: Several randomized trials have confirmed the advantages of patching over primary closure when performing CEA. METHODS: Two hundred CEAs (180 patients) were randomized into 100 with PTFE patching and 100 with Hemashield. All patients underwent postoperative color duplex ultrasounds at 1, 6, and 12 months, and every year thereafter. The mean follow-up was 26 months. Kaplan-Meier analysis was used to estimate the risk of re-stenosis, stroke, and stroke-free survival. A multivariate analysis of various risk factors was also done. RESULTS: Demographic and clinical characteristics were similar in both groups. The incidence of all ipsilateral strokes (early and late) was 8% (7% perioperative) for Hemashield versus 0% for PTFE patching. Both groups had similar mortality rates. The cumulative stroke-free rates at 6, 12, 24, and 36 months were 93%, 93%, 93%, and 89% for Hemashield versus 100%, 100%, 100%, and 100% for PTFE patching. The cumulative stroke-free survival rates at 6, 12, 24, and 36 months were 90%, 89%, 87%, and 79% for Hemashield versus 98%, 98%, 92%, and 92% for PTFE patching. Kaplan-Meier analysis also showed that freedom from 50% or greater re-stenosis at 6, 12, 24, and 36 months was 89%, 81%, 73%, and 66% for Hemashield versus 100%, 100%, 100%, and 92% for PTFE. Similarly, the freedom from 70% or greater re-stenosis at 6, 12, 24, and 36 months was 93%, 91%, 86%, and 78% for Hemashield versus 100%, 100%, 100%, and 100% for PTFE. Univariate and multivariate analyses of demographic and preoperative risk factors showed that only Hemashield was significantly associated with a higher incidence of 70% or greater recurrent stenosis. CONCLUSIONS: PTFE patching was superior to Hemashield in lowering the incidence of postoperative ipsilateral strokes and late recurrent stenosis.


Assuntos
Angioplastia/métodos , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas , Polietilenotereftalatos/uso terapêutico , Politetrafluoretileno/uso terapêutico , Idoso , Estenose das Carótidas/epidemiologia , Colágeno/uso terapêutico , Comorbidade , Feminino , Seguimentos , Humanos , Tábuas de Vida , Masculino , Análise Multivariada , Estudos Prospectivos , Recidiva , Fatores de Risco
2.
J Vasc Surg ; 35(1): 125-30, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11802143

RESUMO

PURPOSE: Several studies have reported that carotid endarterectomy (CEA) with patch angioplasty has results that are superior to primary closure. Polytetrafluoroethylene (PTFE) patching has been shown to have results comparable with autogenous vein patching; however, it requires a prolonged hemostasis time. Therefore, many surgeons are using collagen-impregnated Dacron patching (Hemashield [HP]). This study is the first prospective randomized trial comparing CEA with PTFE patching versus HP patching. METHODS: Two hundred CEAs were randomized into two groups, 100 PTFE and 100 HP patching. All patients underwent immediate postoperative and 1-month postoperative color duplex ultrasound scanning studies. Demographic and clinical characteristics were similar in both groups, including the mean operative diameter of the internal carotid artery. RESULTS: The perioperative stroke rates were 0% for PTFE, versus 7% for HP (4 major and 3 minor strokes, P =.02). The combined perioperative stroke and transient ischemic attack rates were 3% for PTFE, versus 12% for HP (P =.047). The operative mortality rate for PTFE was 0%, versus 2% for HP (P =.477). Five perioperative carotid thromboses were noted in patients undergoing HP patching, versus none in patients undergoing PTFE patching (P =.07). After 1 month of follow-up, 2% of patients in the PTFE group had a 50% or more restenosis, versus 12% of patients in the HP group (P =.013). The mean operative time for PTFE patching was 119 minutes, versus 113 minutes for HP patching (P =.081). The mean hemostasis time was significantly higher for PTFE patching than for HP patching, 14.4 versus 3.4 minutes (P <.001). CONCLUSION: CEA with HP patching had a higher incidence of perioperative strokes, carotid thrombosis, and 50% or more early restenosis than CEA with PTFE patching. However, the mean hemostasis time was higher for PTFE patching than for HP patching.


Assuntos
Estenose das Carótidas/cirurgia , Colágeno/uso terapêutico , Endarterectomia das Carótidas/efeitos adversos , Polietilenotereftalatos/uso terapêutico , Politetrafluoretileno/uso terapêutico , Acidente Vascular Cerebral/etiologia , Idoso , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/cirurgia , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/mortalidade , Colágeno/efeitos adversos , Feminino , Seguimentos , Humanos , Masculino , Polietilenotereftalatos/efeitos adversos , Politetrafluoretileno/efeitos adversos , Complicações Pós-Operatórias , Estudos Prospectivos , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler em Cores