Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Heart ; 103(2): 111-116, 2017 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-27511446

RESUMO

OBJECTIVE: To evaluate the long-term follow-up of the unrestricted use of a biodegradable polymer-coated drug-eluting stent in patients undergoing percutaneous coronary intervention (PCI). METHODS: The Nobori 2 study was a prospective, multicentre, observational registry evaluating the safety and the efficacy of the biodegradable polymer biolimus-eluting stent (BP-BES) among 3067 patients recruited at 125 international sites. The primary combined endpoint was a composite of cardiac death, myocardial infarction and target-lesion revascularisation (TLR). RESULTS: Five-year follow-up was available in 2738 (89.3%) patients. The combined endpoint occurred in 268 patients (10%, 95% CIs 8.9% to 11.3%) at 5 years, with 3.9% of events during the first year and 6.2% during years 1-5 of follow-up. Cumulative rates of TLR and definite/probable stent thrombosis were 5.3% (95% CI 4.5% to 6.3%) and 1.1% (95% CI 0.8% to 1.6%), respectively. Between 1 and 5 years, TLR and very late stent thrombosis rates were 3.5% (95% CI 2.8% to 4.4%) and 0.6% (95% CI 0.3% to 1.1%), respectively. Previous PCI (HR, 2.05, 95% CI 1.68 to 2.50), moderate-to-severe renal disease (HR, 1.89, 95% CI 1.30 to 2.74) and peripheral vascular disease (HR, 1.86, 95% CI 1.38 to 2.52) were the three most powerful independent predictors of the combined endpoint at 5 years. CONCLUSIONS: The final 5-year follow-up of the Nobori 2 registry demonstrates the safety and effectiveness of the BP-BES in an unselected, broadly inclusive cohort of PCI patients, highlighting the excellent performance of this coronary stent technology after polymer biodegradation. TRIAL REGISTRATION NUMBER: ISRCTN81649913; Results.


Assuntos
Implantes Absorvíveis , Stents Farmacológicos , Imunossupressores/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Implantes Absorvíveis/efeitos adversos , Idoso , Trombose Coronária/epidemiologia , Trombose Coronária/etiologia , Stents Farmacológicos/efeitos adversos , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Nefropatias/epidemiologia , Nefropatias/etiologia , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Doenças Vasculares Periféricas/epidemiologia , Doenças Vasculares Periféricas/etiologia , Polímeros , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Retratamento/estatística & dados numéricos , Sirolimo/administração & dosagem , Resultado do Tratamento
2.
EuroIntervention ; 11(5): 541-8, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25136883

RESUMO

AIMS: To report the six-month angiographic and two-year clinical outcome data from the first-in-man study with the Ultimaster DES, a thin-strut cobalt-chromium sirolimus-eluting stent (SES) with an innovative abluminal-gradient-coated bioresorbable polymer. METHODS AND RESULTS: CENTURY is a multicentre, single-arm, prospective study that enrolled 105 patients (113 lesions) with coronary artery disease. All patients were scheduled to have an angiographic follow-up at six months, while 45 and 20 patients respectively had IVUS and OCT assessments. The primary endpoint was six-month in-stent late lumen loss. Secondary endpoints included clinical, IVUS and OCT outcomes. Clinical follow-up is available up to two years and will continue up to five years. Procedural success was 97.1% and device success was 100%. Angiographic late loss at six months was 0.04±0.35 mm, also reflected in a low binary restenosis rate of 0.9% and confirmed by IVUS-assessed neointimal volume obstruction of 1.02±1.62%. The mean strut coverage assessed by OCT was 96.2% with 1.66±4.02 malapposed stent struts. There were no deaths in the study, three (2.9%) periprocedural and one (0.9%) spontaneous myocardial infarction, not related to the target vessel. At one and two years, the target lesion failure rate was 3.8% and 5.7%, while the TLR rate was 1.9% and 2.8%, respectively. There was one acute definite stent thrombosis. CONCLUSIONS: The Ultimaster™ novel bioresorbable polymer sirolimus-eluting stent demonstrated good performance, including high procedural success and strong suppression of neointimal proliferation at six months. Good safety and effectiveness were shown up to two years in the studied population.


Assuntos
Antibióticos Antineoplásicos/uso terapêutico , Ligas de Cromo , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Neointima , Intervenção Coronária Percutânea , Polímeros , Sirolimo/uso terapêutico , Implantes Absorvíveis , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/terapia , Estudos Prospectivos , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção
3.
EuroIntervention ; 8(1): 109-16, 2012 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-22278136

RESUMO

AIMS: Previous studies for approved indications (on-label) have shown the good safety and efficacy profiles of the Nobori DES. We conducted a prospective, multicentre study to validate the clinical performance of this stent in a real-world setting. METHODS AND RESULTS: A total of 3,067 consecutive patients undergoing a percutaneous coronary intervention with the Nobori DES were enrolled in the NOBORI 2 registry. At one and two years, 97% and 95% of patients, respectively, were available for follow-up. The rates of target lesion failure (TLF), cardiac death, myocardial infarction and target lesion revascularisations were: 3.9%, 1.2%, 1.9% and 2.2% at one year and 5.1%, 1.6%, 2.4% and 3.0% at two years. Overall, 2,242 patients (73%) were treated for at least one off-label indication. When comparing off-label and on-label groups, the results were: TLF 4.5% vs. 2.2%, p=0.003 at one year and 5.9% vs. 2.8%, p=0.001 at two years. The rate of stent thrombosis was 0.68%, and 0.80% at one and two years, respectively with no difference between the off-label and on-label groups (0.76% vs. 0.48%, p=0.6 and 0.89% vs. 0.61%, p=0.5). CONCLUSIONS: The promising results previously observed in lower risk patients can be replicated in daily practice. As expected, in off-label indications, rates of adverse events were higher. Nevertheless, our results suggest the good and sustained performance of this stent system in high-risk patients with significant comorbidities and/or complex lesions.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Polímeros , Idoso , Análise de Variância , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Ásia , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/mortalidade , Europa (Continente) , Feminino , Fidelidade a Diretrizes , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Guias de Prática Clínica como Assunto , Rotulagem de Produtos , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA