Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Vasc Med ; 27(5): 457-465, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35943120

RESUMO

BACKGROUND: The objective of the RANGER II SFA long lesion cohort analysis was to evaluate the safety and effectiveness of the Ranger drug-coated balloon (DCB) in patients with lesion lengths greater than 100 mm. METHODS: Patients from the RANGER II SFA randomized controlled trial and long balloon sub-study were included in the long lesion cohort if their baseline lesion measurement was > 100 mm and if they had been treated with a RANGER DCB. Patients had symptomatic lower limb peripheral artery disease and Rutherford classification 2-4 symptomatology. The endpoints of interest included the 12-month target lesion primary patency and freedom from major adverse events (MAEs).Additional patient outcomes including changes in Rutherford classification were also evaluated. RESULTS: A total of 129 patients met the inclusion criteria and were included in the long lesion cohort. Mean lesion length was 144.5 ± 31.7 mm. Seventy-five lesions had Peripheral Arterial Calcium Scoring System (PACSS) grades 3 (33.3%, 43/129) and 4 (24.8%, 32/129). The Kaplan-Meier estimate of the primary patency rate at 12 months was 88.0%. The rate of freedom from MAEs at 12 months was 95.1% (117/123; 95% CI: 89.7%, 98.2%); all MAEs were clinically driven target lesion revascularization (4.9%, 6/123). The 12-month mortality rate was 2.4% (3/125). CONCLUSIONS: Patients with lesions > 100 mm treated with Ranger DCBs demonstrated excellent 1-year safety and efficacy results, comparable to those of the overall RANGER II SFA randomized clinical trial. This suggests that the Ranger DCB can provide consistent results regardless of lesion length. (ClinicalTrials.gov Identifier: NCT03064126).


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Angioplastia com Balão/efeitos adversos , Cálcio , Materiais Revestidos Biocompatíveis , Estudos de Coortes , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/patologia , Humanos , Paclitaxel/efeitos adversos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Artéria Poplítea , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
2.
Catheter Cardiovasc Interv ; 91(3): 497-504, 2018 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-29086462

RESUMO

OBJECTIVES: The purpose of this study was to assess the safety and performance of Stellarex Drug-coated balloon (DCB). BACKGROUND: DCB coatings differ in excipients, paclitaxel dose, and coating morphologies. Due to these differences, a class effect with DCBs has not been demonstrated. Consequently, each DCB needs to be evaluated independently based on its own clinical study results. METHODS: The ILLUMENATE Global Study is a prospective, multicenter, single-arm study. Patients with intermittent claudication or ischemic rest pain due to superficial femoral artery (SFA) and/or popliteal peripheral artery disease (PAD) were treated with the Stellarex DCB. The primary efficacy endpoint was primary patency, defined as freedom from restenosis with peak systolic velocity ratio ≤2.5 or clinically-driven target lesion revascularization (CD-TLR) at 12 months. The primary safety endpoint was freedom from device and procedure-related death through 30 days postprocedure and freedom from target limb major amputation and CD-TLR through 12 months. RESULTS: In total, 417 lesions were treated in 371 patients. The mean lesion length was 7.5 ± 5.3 cm, 40.8% of lesions were severely calcified per core laboratory fluoroscopy criteria and 31.3% were total occlusions. Primary patency by independent duplex core lab evaluation was 81.4% and the freedom from CD-TLR was 94.8% day 365 per Kaplan-Meier estimate. The majority of patients experienced improvements in their Rutherford classification (90.3%) and walking impairment questionnaire score (83.6%) at 12 months compared to baseline. CONCLUSIONS: This study validated previous positive findings and confirms the strong safety profile and effectiveness outcomes.


Assuntos
Angioplastia com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Artéria Femoral , Paclitaxel/administração & dosagem , Doença Arterial Periférica/terapia , Artéria Poplítea , Dispositivos de Acesso Vascular , Idoso , Angioplastia com Balão/efeitos adversos , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Fluxo Sanguíneo Regional , Fatores de Tempo , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 89(6): 1069-1077, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28296239

RESUMO

OBJECTIVES: The SuperNOVA trial was designed to evaluate performance of the Innova Vascular Self-Expanding Stent System (Boston Scientific, Marlborough, MA) for treating lesions in the femoropopliteal arteries. METHODS: Patients with chronic lower limb peripheral artery disease (Rutherford category 2, 3, or 4) and atherosclerotic lesions in the native superficial femoral and/or proximal popliteal artery (lengths 30-190 mm) were enrolled in this single-arm, multinational study. Major adverse events (MAEs) were defined as all-cause death through 1 month, target limb major amputation, and target lesion revascularization (TLR). Vessel primary patency was defined as core laboratory-adjudicated duplex ultrasonography-derived peak systolic velocity ratio ≤2.4 in the absence of TLR, surgical bypass of the target lesion, or major amputation of the target limb. Primary safety and efficacy endpoints were evaluated at 12 months, with follow-up through 24 months also reported. RESULTS: SuperNOVA patients (N = 299; mean age 67.4 ± 9.7 years, 74% men, 41% with diabetes) had a mean lesion length of 93.2 mm. The MAE-free rate was 99.7% at 30 days, 85.8% at 12 months, and 77% at 24 months. Kaplan-Meier estimates of primary patency and TLR-free rates were 68.7% and 78.0%, respectively, at 24 months. Clinical improvements were sustained through 2 years, with 80% of patients displaying no or minimal symptoms (Rutherford category 0-1) at 24 months. CONCLUSIONS: In the SuperNOVA study, the Innova Stent System demonstrated an excellent safety profile and acceptable clinical outcomes despite the challenging anatomical characteristics of the lesions. © 2017 Wiley Periodicals, Inc.


Assuntos
Angioplastia com Balão/instrumentação , Artéria Femoral , Doença Arterial Periférica/terapia , Artéria Poplítea , Stents Metálicos Autoexpansíveis , Idoso , Ligas , Angioplastia com Balão/efeitos adversos , Intervalo Livre de Doença , Europa (Continente) , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Japão , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , América do Norte , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Dupla , Grau de Desobstrução Vascular
4.
J Endovasc Ther ; 23(5): 701-7, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27193308

RESUMO

PURPOSE: To report the 12-month results of the MAJESTIC clinical study of the self-expanding Eluvia paclitaxel-eluting stent in the treatment of femoropopliteal lesions. METHODS: The prospective, single-arm, multicenter trial (clinicaltrials.gov identifier NCT01820637) enrolled 57 patients (mean age 69±9 years; 47 men) with chronic lower limb ischemia referable to de novo or restenotic lesions in the native superficial femoral and/or proximal popliteal arteries. A third of the patients had diabetes. Mean lesion length was 70.8±28.1 mm, and diameter stenosis was 86.3%±16.2%; 26 (46%) lesions were occluded. Primary patency was defined as duplex ultrasound peak systolic velocity ratio ≤2.5 and the absence of target lesion revascularization (TLR) or bypass. Major adverse events (MAEs) included all-cause death through 1 month and target limb major amputation and TLR through 12 months. RESULTS: All 57 patients had a single Eluvia stent implanted, employing pre- and postdilation in 93% (53/57) and 95% (54/57) of cases, respectively. Technical success was 97% (55/57; 2 failures due to residual stenosis >30%). At 12 months, primary patency was 96% (49/51) and the MAE rate was 4% (2/53); both MAEs were TLRs. No stent fractures were identified. There were no major amputations. One death occurred 368 days postprocedure, unrelated to the device or procedure. Improvements in the Rutherford category were sustained through 1 year, with 81% (43/53) exhibiting no symptoms (category 0) and 13% (7/53) presenting with mild claudication (category 1). Mean ABI improved from 0.73±0.22 at baseline to 1.02±0.20 at 12 months. CONCLUSION: MAJESTIC results showed that patients whose femoropopliteal arteries were treated with the Eluvia drug-eluting stent sustained high patency and low MAE rates through 12 months.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Stents Farmacológicos , Procedimentos Endovasculares/instrumentação , Artéria Femoral , Isquemia/terapia , Paclitaxel/administração & dosagem , Doença Arterial Periférica/terapia , Artéria Poplítea , Stents Metálicos Autoexpansíveis , Idoso , Ligas , Índice Tornozelo-Braço , Austrália , Velocidade do Fluxo Sanguíneo , Fármacos Cardiovasculares/efeitos adversos , Doença Crônica , Constrição Patológica , Procedimentos Endovasculares/efeitos adversos , Europa (Continente) , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Isquemia/diagnóstico por imagem , Isquemia/fisiopatologia , Estimativa de Kaplan-Meier , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Nova Zelândia , Paclitaxel/efeitos adversos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Fluxo Sanguíneo Regional , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Dupla , Grau de Desobstrução Vascular
5.
J Endovasc Ther ; 22(1): 1-10, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25775672

RESUMO

PURPOSE: To evaluate the short- and midterm outcomes of the Viabahn endoprosthesis with Propaten Bioactive Surface vs. standard balloon angioplasty for treatment of in-stent restenosis in the superficial femoral artery. METHODS: Between June 2010 and February 2012, 83 patients with superficial femoral artery in-stent and Rutherford category 2 to 5 ischemia were enrolled at 7 sites participating in this prospective randomized controlled study (RELINE; ClinicalTrials.gov; identifier NCT01108861). The patients were randomized to treatment with either the heparin-bonded Viabahn endoprosthesis (n = 39: 29 men; mean age 67.7 ± 9.8 years) or a standard angioplasty balloon (n = 44: 32 men; mean age 69.0 ± 9.7 years). The primary effectiveness outcome was primary patency at 12 months, defined as no restenosis/occlusion within the target lesion based on duplex ultrasound and no target lesion revascularization. The primary safety endpoint was the incidence of serious device-related adverse events within 30 days of the procedure. RESULTS: All patients randomized to receive dilation or the Viabahn stent-graft were treated according to their assignment. The technical success was 100% for the Viabahn group and 81.8% for the angioplasty group (p = 0.002) owing to 9 patients requiring a bailout procedure after unsuccessful angioplasty. The 12-month primary patency rates were 74.8% for the Viabahn group and 28.0% for the angioplasty group (p < 0.001). Excluding the 9 angioplasty patients who received bailout stenting, the primary patency for optimal balloon angioplasty was 37.0% (p < 0.001). Three patients experienced device-related adverse events within 30 days: occlusion of the target lesion (Viabahn group), peripheral embolization (angioplasty group), and reocclusion of the target lesion (angioplasty group). CONCLUSION: In this study, the treatment of femoropopliteal in-stent restenosis with a Viabahn endoprosthesis showed significantly better results than treatment with a standard balloon at 1 year.


Assuntos
Angioplastia com Balão , Stents Farmacológicos , Artéria Femoral , Doença Arterial Periférica/terapia , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/métodos , Bélgica , Materiais Revestidos Biocompatíveis , Constrição Patológica , Feminino , Seguimentos , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/patologia , Estudos Prospectivos , Recidiva , Método Simples-Cego , Stents/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
6.
JACC Cardiovasc Interv ; 14(10): 1123-1133, 2021 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-34016410

RESUMO

OBJECTIVES: This study sought to evaluate the safety and effectiveness of the Ranger drug-coated balloon (DCB) (paclitaxel dose density 2 µg/mm2) for treating superficial femoral artery or proximal popliteal artery lesions. BACKGROUND: Paclitaxel-coated balloon treatment prevents reinterventions, but dose and coating characteristics differ among balloons and necessitate discrete confirmation of safety and effectiveness. METHODS: Patients with symptomatic lower limb ischemia (Rutherford classification 2 to 4) were randomized 3:1 to treatment with the Ranger DCB or standard percutaneous transluminal angioplasty (PTA). Twelve-month primary target lesion patency, freedom from major adverse events (i.e., target lesion revascularization, major amputations, death within 1 month of the index procedure), and patient outcomes were analyzed. RESULTS: Mean lesion length was 82.5 ± 48.9 mm for the Ranger DCB group (n = 278) and 79.9 ± 49.3 mm for the control group (n = 98). Ranger DCB was superior to PTA (82.9% [n = 194 of 234] vs. 66.3% [n = 57 of 86]) with observed 12-month primary patency rates yielding a difference of 16.6% (95% confidence interval: 5.5% to 27.7%; p = 0.0013). Noninferior freedom from major adverse events (94.1% [n = 241 of 256] vs. 83.5% [n = 76 of 91]) was demonstrated with a difference of 10.6% (95% confidence interval: 2.5% to 18.8%; noninferiority p < 0.0001). Primary patency rate curves showed significant separation by Kaplan-Meier analysis (log-rank p = 0.0005), with rates of 89.8% and 74.0% estimated at day 365 for the Ranger DCB and PTA cohorts, respectively. CONCLUSIONS: The low-dose Ranger DCB demonstrated significantly better effectiveness than standard PTA through 1 year and a good safety profile. (Ranger™ Paclitaxel Coated Balloon vs Standard Balloon Angioplasty [RANGER II SFA]; NCT03064126).


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Preparações Farmacêuticas , Angioplastia com Balão/efeitos adversos , Materiais Revestidos Biocompatíveis , Artéria Femoral/diagnóstico por imagem , Humanos , Paclitaxel/efeitos adversos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Artéria Poplítea/diagnóstico por imagem , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
7.
J Endovasc Ther ; 16(3): 261-9, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19642788

RESUMO

PURPOSE: To evaluate the long-term efficacy and integrity of the PROTEGE EverFlex stent in superficial femoral artery (SFA) lesions in symptomatic patients with peripheral artery disease (PAD). METHODS: A prospective, multicenter, nonrandomized study enrolled 151 subjects (111 men; mean age 67.8 years, range 42-93) undergoing percutaneous treatment of de novo, restenotic, or reoccluded SFA lesions between August 11, 2006, and June 26, 2007. Subjects were scheduled to receive a single stent and be evaluated through 12 months following the implant procedure. Occlusions were present in 40% of the patients. Mean lesion length was 96.4 mm (range 10-150). RESULTS: A total of 161 stents (158 EverFlex) were implanted in the 151 patients: single stents in 93.4% (141/151) and a second stent in 6.6% (10/151). One-year follow-up information was available for 88.7% (134/151) of the study participants; of the remaining 17 subjects, 6 subjects withdrew from the study, 2 were lost to follow-up, and 9 died. Freedom from restenosis data were available for 99.3% (133/134) of the subjects who completed a 12-month follow-up visit. The mean Rutherford classification fell from 2.8+/-0.8 (range 1-5) at baseline to 0.6+/-1.1 (range 0-5) at 12 months. The mean ankle-brachial index rose from 0.6+/-0.2 (range 0-1.4) at baseline to 0.9+/-0.2 (range 0-1.2) at 12 months. The rates for freedom from >50% restenosis at 6 and 12 months were 91.3% (95% CI 84.9% to 95.2%) and 72.2% (95% CI 63.8% to 79.6%), respectively. The freedom from target lesion revascularization rate at 12 months was 79.1% (95% CI 71.2% to 85.6%). The 1-year stent fracture rate was 8.1% (95% CI 4.0% to 14.4%). CONCLUSION: The high freedom from >50% restenosis and low fracture rate at 12 months suggests that the PROTEGE EverFlex stent offers a safe and acceptably efficacious means of treating SFA lesions in symptomatic subjects with PAD.


Assuntos
Ligas , Angioplastia com Balão , Aterosclerose/terapia , Artéria Femoral , Doenças Vasculares Periféricas/terapia , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Seguimentos , Oclusão de Enxerto Vascular/epidemiologia , Oclusão de Enxerto Vascular/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
8.
J Vasc Surg ; 43(2): 313-8; discussion 318-9, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16476607

RESUMO

OBJECTIVE: Several prosthetic materials have been used for femoropopliteal bypass grafting in patients with peripheral vascular disease in whom a venous bypass is not possible. Expanded polytetrafluoroethylene (ePTFE) is the most commonly used, but patency results have not always equaled those achieved with vein, especially in below-knee reconstructions. This study assessed the performance of a new heparin-bonded ePTFE vascular graft that was designed to provide resistance to thrombosis and thereby decrease early graft failures and possibly prolong patency. METHOD: From June 2002 to June 2003, 86 patients (62 men and 24 women; mean age, 70 years; 99 diseased limbs) were enrolled prospectively in a nonrandomized, multicenter study of the heparin-bonded ePTFE graft. Fifty-five above-knee and 44 below-knee (including 21 femorocrural) procedures were performed. Follow-up evaluations consisted of clinical examinations, ultrasonographic studies, and distal pulse assessments. Patency and limb salvage rates were assessed by using life-table analyses. RESULTS: All grafts were patent immediately after implantation. There were no graft infections or episodes of prolonged anastomotic bleeding. During the 1-year follow-up, 10 patients died, 15 grafts occluded, and 5 major amputations were performed. The overall primary and secondary 1-year patency rates were 82% and 97%, respectively. The limb salvage rate in patients with critical limb ischemia (n = 41) was 87%. Primary patency rates according to bypass type were 84%, 81%, and 74% for above-knee femoropopliteal, below-knee femoropopliteal, and femorocrural bypasses, respectively; the corresponding secondary patency rates were 96%, 100%, and 100%. CONCLUSIONS: In this study, the heparin-bonded ePTFE graft provided promising early patency and limb salvage results, with no device-related complications, in patients with occlusive vascular disease. Longer-term and randomized studies are warranted to determine whether this graft provides results superior to those achieved with other prostheses, especially in patients at increased risk of early graft failure, such as those undergoing below-knee bypass and those with poor run-off or advanced vascular disease.


Assuntos
Anticoagulantes/administração & dosagem , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Artéria Femoral/cirurgia , Heparina/administração & dosagem , Doenças Vasculares Periféricas/cirurgia , Politetrafluoretileno , Artéria Poplítea/cirurgia , Idoso , Idoso de 80 Anos ou mais , Amputação Cirúrgica , Bélgica/epidemiologia , Implante de Prótese Vascular/efeitos adversos , Feminino , Artéria Femoral/fisiopatologia , Seguimentos , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/prevenção & controle , Humanos , Tábuas de Vida , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Doenças Vasculares Periféricas/mortalidade , Doenças Vasculares Periféricas/fisiopatologia , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Índice de Gravidade de Doença , Trombose/etiologia , Trombose/fisiopatologia , Trombose/prevenção & controle , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA