Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Orthod Craniofac Res ; 27(2): 211-219, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37553952

RESUMO

BACKGROUND: Root resorption in orthodontics is associated with direction and magnitude of force application as primary etiological factors. Well-controlled trials that utilize three-dimensional segmentation to detect volumetric changes in tooth structure are required to assess the quantitative nature of root resorption. OBJECTIVE: To assess the severity of root resorption (RR) during retraction of maxillary anteriors with three different force vectors (with and without skeletal anchorage) via cone-beam computed tomography (CBCT) superimpositions. TRIAL DESIGN: Three-arm parallel randomized clinical trial (RCT). MATERIALS AND METHODS: Forty-two (16 males, 26 females) patients, (17-28 years), in permanent dentition with bimaxillary protrusion were randomly allocated to three groups of 14 patients each using block randomization (1:1:1 ratio) and allocation concealment. En-masse anterior retraction post first premolar extractions was carried out with modified force vectors in the three groups based on anchorage type [Molar, Mini-implant and Infrazygomatic crest (IZC) bone screws]. Volumetric root loss and linear dimensional changes were blindly assessed on initial (T0) and final (T1, end of space closure) CBCT scans. Normality distribution of values was done using Shapiro-Wilk's test. ANOVA and Post-hoc Tukey HSD test were done to compare measurements between groups at significance levels (P < .05). RESULTS: Forty patients were analysed (14, 14, and 12 in three groups). Significant volumetric loss was noted in all groups. Central incisors demonstrated a significant reduction in IZC group (81.5 ± 21.1 mm3 ) compared to conventional (50.1 ± 26.5 mm3 ) and mini-implant groups (76.1 ± 27.6 mm3 ). Canines demonstrated a significant reduction in mini-implant group (108.9 ± 33.9 mm3 ) compared to conventional (68.8 ± 42.5 mm3 ) and IZC groups (103.1 ± 29.1 mm3 ). Regarding linear parameters, central incisors and canines revealed significant root length reduction in both skeletal anchorage groups. Lateral incisors showed no significant changes between groups. CONCLUSIONS: Intrusive force vectors generated during skeletally anchored retraction can predispose anteriors to an increased risk of resorption. Greater loss of root volume was noted in the centrals and canines when retracted with skeletal anchorage. LIMITATIONS: Small sample size and variations during CBCT acquisition. HARMS: Low-dose CBCT scans were taken at T0 and T1 treatment intervals.


Assuntos
Procedimentos de Ancoragem Ortodôntica , Reabsorção da Raiz , Feminino , Humanos , Masculino , Tomografia Computadorizada de Feixe Cônico , Incisivo/diagnóstico por imagem , Maxila/diagnóstico por imagem , Dente Molar , Procedimentos de Ancoragem Ortodôntica/métodos , Reabsorção da Raiz/diagnóstico por imagem , Reabsorção da Raiz/etiologia , Técnicas de Movimentação Dentária/efeitos adversos , Adolescente , Adulto Jovem , Adulto
2.
Eur Rev Med Pharmacol Sci ; 27(17): 7898-7906, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37750618

RESUMO

OBJECTIVE: The aim of this study was to compare the scanning accuracy of two different intra-oral scanners- MEDIT i500 and TRIOS 3 shape in reproducing orthodontic bracket dimensions. MATERIALS AND METHODS: This in vivo cross-sectional study comprised seven subjects with a full complement of permanent dentition without third molars. Complete arch scanning was carried out with two intraoral scanners, such as MEDIT i500, TRIOS 3 shape, after bonding with brackets. The control group consisted of bracket dimensions measured directly by using Vernier calipers before bonding. Bracket dimensions of three-dimensional (3D) images were measured by using OrthoAnalyzer software. The accuracy of intraoral scanning was investigated by comparing bracket dimensions among the three groups using One-way ANOVA and Post-Hoc Tukey HSD test, and by evaluating outcomes for each quadrant and an individual tooth in complete-arch scans. RESULTS: When comparing bracket dimensions of 3D images with manual measurements using a traditional Vernier caliper, MEDIT i500 showed no significant difference when compared to the control group (p>0.05) in full arch scanning as well as the quadrant and single tooth scans in complete arch scanning. TRIOS 3 shape showed a significant difference when compared to the control and MEDIT i500 group (p<0.05) for all parameters. CONCLUSIONS: MEDIT i500 showed higher accuracy and better reproduction of orthodontic bracket dimensions than TRIOS 3 shape.


Assuntos
Braquetes Ortodônticos , Humanos , Estudos Transversais , Dente Serotino , Apego ao Objeto , Cintilografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA