Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Tipo de estudo
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Masui ; 63(8): 927-30, 2014 Aug.
Artigo em Japonês | MEDLINE | ID: mdl-25199336

RESUMO

BACKGROUND: KingVision (KV) is a new videolaryngoscope. In this study, we compared the ease of use of the KV with the Airwayscope (AWS) by experienced personnel in a simulated manikin. METHODS: Twenty-eight anesthesiologists participated in this study. We used an advanced patient simulator (AIRSIM) to simulate normal manikin and difficult airway scenarios including cervical spine rigidity and limited mouth opening. We compared the time required for visualization of the glottis (Tv) and tracheal intubation (Ti), and analyzed the percentage of glottic opening (POGO) score and the success rates for tracheal intubation. RESULTS: In normal manikin, the Tv and Ti with the KV were significantly shorter than with the AWS (P < 0.05). The POGO score with the KV was higher than with the AWS (P < 0.05). In difficult airway scenarios including both cervical spine rigidity and limited mouth opening, the Tv and Ti with the KV were shorter than with only the AWS (P < 0.05). There is not much difference between KV and AWS regarding the POGO score in difficult airway. CONCLUSIONS: KV may be a suitable device for routine anesthesia care and difficult airway intubation. Further studies in a clinical setting are necessary to confirm these findings.


Assuntos
Anestesiologia/instrumentação , Intubação Intratraqueal/instrumentação , Laringoscópios , Manequins , Simulação de Paciente , Gravação em Vídeo/instrumentação , Anestesiologia/métodos , Glote/patologia , Glote/fisiopatologia , Humanos , Intubação Intratraqueal/métodos , Fatores de Tempo
2.
JA Clin Rep ; 1(1): 5, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-29497637

RESUMO

An optical surgical navigation system is used as a navigator to facilitate surgical approaches, and pulse oximeters provide valuable information for anesthetic management. However, saw-tooth waves on the monitor of a pulse oximeter and the inability of the pulse oximeter to accurately record the saturation of a percutaneous artery were observed when a surgeon started an optical navigation system. The current case is thought to be the first report of this navigation system interfering with pulse oximetry. The causes of pulse jamming and how to manage an optical navigation system are discussed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA