Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de estudo
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Toxicol Pathol ; 47(3): 408-417, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30282527

RESUMO

Nitinol stents are widely used for the treatment of peripheral arterial diseases in lower extremity arteries and have shown different clinical outcomes depending on implanted arterial segments. We aimed to compare histopathological responses to nitinol stents in femoral artery (FA) with those in femoropopliteal artery (FPA), which is markedly bended during knee flexion. A single nitinol stent was implanted in FA and FPA of 21 domestic swine. The stented vessels were angiographically assessed and then harvested for histopathology at 1 and 3 months after implantation. Angiographic late lumen loss was significantly greater in FPA than in FA at 3 months. Neointimal area decreased in FA and increased in FPA from 1 to 3 months. Compared with FA, peri-strut area of FPA showed more pronounced hemorrhage and fibrin deposition at 1 month and angiogenesis and inflammation at 1 and 3 months. Injury to internal elastic lamina or media was minimal in both FA and FPA at both time points. In conclusion, vascular responses to nitinol stents were different between FA and FPA with respect to time course of neointimal formation and progress of healing, suggesting that repetitive interaction between stent and vessel wall during dynamic vessel motion affected vascular responses.


Assuntos
Ligas/toxicidade , Artéria Femoral/patologia , Artéria Poplítea/patologia , Stents/efeitos adversos , Angiografia , Animais , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Técnicas Histológicas , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/cirurgia , Suínos
2.
Toxicol Pathol ; 47(3): 401-407, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30585131

RESUMO

We have developed a new method for obtaining information on whole tissues by light microscopy (LM) and ultrastructural features by transmission electron microscopy (TEM). This method uses serial sections of a stented artery embedded in resin. Stents were implanted in porcine coronary arteries in this study. The heart was perfusion fixed in a 2% paraformaldehyde and 1.25% glutaraldehyde mixed solution. The stented artery was then removed, fixed in 1% osmium, embedded in Quetol 651 resin, and sectioned serially. For LM, the black color of osmium was removed from the section by immersion in periodic acid and hydrogen peroxide after deplasticization. These sections were stained with hematoxylin and eosin and Elastica-Masson trichrome stain. For TEM, thin sections were re-embedded in Quetol 812 resin by the resupinate method and cut into ultrathin sections. A clear, fine structure was obtained, and organelles, microvilli, and cell junctions in the endothelium were easily observed. The combined observation of adjacent specimens by LM and TEM enabled us to relate histopathological changes in the millimeter scale to those in the nanometer scale.


Assuntos
Vasos Coronários/ultraestrutura , Resinas Epóxi/química , Técnicas Histológicas/instrumentação , Técnicas Histológicas/métodos , Metacrilatos/química , Stents/efeitos adversos , Animais , Vasos Coronários/patologia , Microscopia , Microscopia Eletrônica de Transmissão , Microtomia/métodos , Suínos
3.
PLoS One ; 14(1): e0209841, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30629613

RESUMO

Current drug-eluting stents have abluminal polymer coating; however, thrombus formation in these compared with that in uniformly coated stents remains controversial. We evaluated thrombus formation and early endothelialization after using abluminal biodegradable polymer-coated sirolimus- (BP-SES), and everolimus-eluting stents (BP-EES) versus a durable polymer-coated everolimus-eluting stent (DP-EES) in an in vivo setting. BP-SES, BP-EES, and DP-EES (n = 6 each) were implanted in coronary arteries of 12 mini-pigs that were then sacrificed after 7 and 10 days. Stents were stained with hematoxylin and eosin, and a combined Verhoeff and Masson trichrome stain. Areas of fibrin deposition were digitally detected and measured with off-line morphometric software. Stents were investigated for re-endothelialization by transmission electron microscopy. At 7 days, histological analysis revealed the lowest area of fibrin deposition in BP-SES (BP-SES vs. BP-EES vs. DP-EES; 0.10 ± 0.06 mm2 vs. 0.15 ± 0.07 mm2 vs. 0.19 ± 0.06 mm2, p = 0.0004). At 10 days, the area of fibrin deposition was significantly greater in DP-EES (0.13 ± 0.04 mm2 vs. 0.14 ± 0.05 mm2 vs. 0.19 ± 0.08 mm2, p = 0.007). Endothelial cells in BP-SES demonstrated a significantly greater number of tight junctions than those in DP-EES according to by transmission electron microscopy for both days (p<0.05). Various parameters, including an inflammatory reaction and neointimal formation, were comparable among the groups at 7 and 10 days. An abluminal biodegradable polymer-coated SES showed the least fibrin deposition and greatest endothelial cell recovery at an early stage following implantation in the coronary arteries of mini-pigs.


Assuntos
Implantes Absorvíveis , Vasos Coronários/cirurgia , Stents Farmacológicos , Polímeros/química , Animais , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis/administração & dosagem , Materiais Revestidos Biocompatíveis/química , Angiografia Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Células Endoteliais/metabolismo , Everolimo/administração & dosagem , Everolimo/química , Fibrina/metabolismo , Modelos Animais , Intervenção Coronária Percutânea , Polímeros/administração & dosagem , Polímeros/efeitos adversos , Desenho de Prótese , Sirolimo/administração & dosagem , Sirolimo/química , Suínos , Porco Miniatura , Trombose/etiologia , Trombose/metabolismo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA