Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 83(4): 581-6, 2014 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-24115686

RESUMO

BACKGROUND: Percutaneous closure of atrial defects (ASD) has evolved as the treatment of choice for the majority of defects and patent oval foramens. The Gore Septal Occluder (GSO) is an innovative device consisting mostly of a folded thin GoreTex tube for use in the closure of septal defects. METHODS: Reviewed is the multicenter UK experience of the first 22 ASD occlusions with the GSO(TM) device. All implantations were performed by consultant operators experienced in ASD device closure. The inclusion criterion was the presence of a hemodynamically significant secundum ASD with a diameter of <18 mm. Procedural data and acute and mid-term closure rates were retrospectively matched to a cohort of patients having defect closure using the Amplatzer Septal Occluder(TM) (ASO(TM) ). RESULTS: Acute and 3-month follow-up closure rates for the GSO(TM) were 100% and 100% vs. 100% and 100% closure with the ASO(TM) implants. The difference in paired procedure times was not statistically significant (56 min: GSO(TM) ; 42 min: ASO(TM) device P = ns), nor was the paired difference in fluoroscopic screening times (12 min: GSO(TM) vs. 8.4 min: ASO(TM) , P = ns). One GSO device embolized immediately after deployment and was successfully retrieved at the same procedure. There were no other significant complications in either group. CONCLUSIONS: The GSO(TM) implant can achieve comparable closure rates to the ASO(TM) in small to moderate atrial septal defects after 3 months. Longer fluoroscopy and procedure times are a drawback; however these should improve with familiarity with the implant and deployment system. The larger sheath size was not associated with increased complications in our cohort.


Assuntos
Cateterismo Cardíaco/instrumentação , Comunicação Interatrial/terapia , Dispositivo para Oclusão Septal , Adulto , Fatores Etários , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Fluoroscopia , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/fisiopatologia , Hemodinâmica , Humanos , Pessoa de Meia-Idade , Politetrafluoretileno , Desenho de Prótese , Radiografia Intervencionista , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Reino Unido
2.
J Am Coll Cardiol ; 70(25): 3127-3136, 2017 12 26.
Artigo em Inglês | MEDLINE | ID: mdl-29268926

RESUMO

BACKGROUND: The CENTERA transcatheter heart valve (THV) is a low-profile, self-expanding nitinol valve made from bovine pericardial tissue that is 14-F compatible with a motorized delivery system allowing for repositionability. OBJECTIVES: The pivotal study evaluated safety and efficacy of this THV in high-surgical-risk study patients with severe symptomatic aortic stenosis. METHODS: Implantations were completed in 23 centers. Clinical and echocardiographic outcomes were assessed at baseline, discharge, and 30 days. Major events were adjudicated by an independent clinical events committee. Echocardiograms and computed tomography scans were reviewed by core laboratories. The primary endpoint was all-cause mortality at 30 days. RESULTS: Between March 25, 2015 and July 5, 2016, 203 patients with severe symptomatic aortic stenosis and increased surgical risk, as determined by the heart team, were treated by transfemoral THV implantation (age 82.7 ± 5.5 years, 67.5% female, 68.0% New York Heart Association functional class III/IV). At 30 days, mortality was 1%, disabling stroke occurred in 2.5% of patients, and New York Heart Association functional class I/II was observed in 93.0% of patients. Effective orifice area increased from 0.71 ± 0.20 cm2 to 1.88 ± 0.43 cm2 (p < 0.001). Mean aortic transvalvular gradient decreased from 40.5 ± 13.2 mm Hg to 7.2 ± 2.8 mm Hg at 30 days post-procedure (p < 0.001). Paravalvular aortic regurgitation at 30 days was moderate or higher in 0.6% of patients. A new permanent pacemaker was implanted in 4.5% of patients receiving the THV (4.9% for patients at risk). CONCLUSIONS: The herein described THV is safe and effective at 30 days with low mortality, significant improvements in hemodynamic outcomes, and low incidence of adverse events. Of particular interest is the low incidence of permanent pacemaker implantations. (Safety and Performance Study of the Edwards CENTERA-EU Self-Expanding Transcatheter Heart Valve [CENTERA-2]; NCT02458560).


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Ligas , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Causas de Morte/tendências , Ecocardiografia , Desenho de Equipamento , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Índice de Gravidade de Doença , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA