Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 92(2): 253-259, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-28940882

RESUMO

OBJECTIVES: To assess the safety and efficacy of the novel Resolute (R-) Onyx drug-eluting stent (DES). BACKGROUND: The R-Onyx DES consists of a composite wire with an outer shell of cobalt chromium alloy and a platinum-iridium inner core to enhance radiopacity, with thinner, swaged struts and modified stent geometry compared with the predicate Resolute DES, resulting in a slightly lower total drug load in most sizes. METHODS: This was a prospective, single-arm non-inferiority trial compared with a historical control. Patients with stable angina/ischemia and up to 2 de novo target lesions ≤35 mm long with reference vessel diameter (RVD) of 2.25-4.2 mm were enrolled. The primary endpoint was late lumen loss at 8-month follow-up. Propensity-score adjusted outcomes from the single-arm RESOLUTE-US trial served as the control. RESULTS: Seventy-five patients (85 lesions) were enrolled. Mean patient age was 66 ± 9 years, 73% were male, and 32% had diabetes. Mean lesion length was 14.28 ± 6.68 mm, mean RVD was 2.57 ± 0.48 mm, and 86% of lesions were class B2/C. In-stent late lumen loss at 8 months was 0.24 ± 0.39 mm with R-Onyx DES compared with 0.36 ± 0.52 mm with Resolute DES (P < 0.001 for noninferiority, P = 0.029 for superiority). At 8 months, clinically driven target lesion revascularization occurred in 3 patients (4.0%) and target lesion failure occurred in 5 patients (6.7%). CONCLUSIONS: In-stent late lumen loss is non-inferior, and appears to be superior, with the thin-strut novel composite wire R-Onyx DES compared with Resolute DES. Continued evolution of stent design can improve angiographic outcomes in complex lesions, even in the current era of next-generation DES.


Assuntos
Angina Estável/cirurgia , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Angina Estável/diagnóstico por imagem , Fármacos Cardiovasculares/efeitos adversos , Ligas de Cromo , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/etiologia , Feminino , Humanos , Irídio , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Platina , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção , Estados Unidos
2.
JAMA ; 294(10): 1215-23, 2005 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-16160130

RESUMO

CONTEXT: Compared with bare metal stents, drug-eluting stents reduce restenosis in noncomplex lesions. The utility of drug-eluting stents has not been evaluated in more difficult stenoses. OBJECTIVE: To investigate the safety and efficacy of the polymer-based, slow-release paclitaxel-eluting stent in a patient population with more complex lesions than previously studied. DESIGN, SETTING, AND PATIENTS: Prospective, placebo-controlled, double-blind, multicenter randomized trial conducted from February 2003 to March 2004 at 66 academic and community-based institutions with 1156 patients who underwent stent implantation in a single coronary artery stenosis (vessel diameter, 2.25-4.0 mm; lesion length, 10-46 mm), including 664 patients (57.4%) with complex or previously unstudied lesions (requiring 2.25-mm, 4.0-mm, and/or multiple stents) and 9-month clinical and angiographic follow-up. INTERVENTIONS: Patients were randomly assigned to receive 1 or more bare metal stents (n = 579) or identical-appearing paclitaxel-eluting stents (n = 577). MAIN OUTCOME MEASURE: Ischemia-driven target vessel revascularization at 9 months. RESULTS: Baseline characteristics were well matched. Diabetes was present in 31% of patients. The mean (SD) reference vessel diameter was 2.69 (0.57) mm, the reference lesion length was 17.2 (9.2) mm, and 78% of lesions were type B2/C. A mean (SD) of 1.38 (0.58) stents (total mean [SD] length, 28.4 [13.1] mm) were implanted per lesion; 33% of lesions required multiple stents. Stents that were 2.25 mm and 4.0 mm in diameter were used in 18% and 17% of lesions, respectively. Compared with bare metal stents, paclitaxel-eluting stents reduced the 9-month rate of target lesion revascularization from 15.7% to 8.6% (P<.001) and target vessel revascularization from 17.3% to 12.1% (P = .02). Similar rates were observed for cardiac death or myocardial infarction (5.5% for bare metal stent group vs 5.7% for paclitaxel-eluting stent group) and stent thrombosis (0.7% in both groups). Angiographic restenosis was reduced from 33.9% to 18.9% in the entire study cohort (P<.001), including among patients receiving 2.25-mm stents (49.4% vs 31.2%; P = .01), 4.0-mm stents (14.4% vs 3.5%; P = .02), and multiple stents (57.8% vs 27.2%; P<.001). CONCLUSION: Compared with a bare metal stent, implantation of the paclitaxel-eluting stent in a patient population with complex lesions effectively reduces clinical and angiographic restenosis.


Assuntos
Doença da Artéria Coronariana/terapia , Imunossupressores/administração & dosagem , Paclitaxel/administração & dosagem , Stents , Idoso , Angioplastia Coronária com Balão , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/prevenção & controle , Método Duplo-Cego , Sistemas de Liberação de Medicamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polímeros , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA