1.
Chemistry ; 14(34): 10797-807, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18942696

RESUMO

We report the synthesis of molecular sheets based on the photochemically initiated dimerization of monomers with lateral anthracene units. The film thickness and composition were investigated by ellipsometry and X-ray photoelectron spectroscopy (XPS). The mechanical stability of the film was sufficient to span it over 45x45 microm-sized holes. Several model reactions were performed to illustrate the underlying chemistry and to assist in analysis. The reported experiments are considered first steps towards the ultimate goal of the rational synthesis of laterally "infinite", one-monomer-unit-thick molecular sheets with a long-range positional order and a periodic covalent-bonding pattern. Such sheets are referred to as 2D polymers and are considered a prime goal of chemical synthesis with intriguing applications.


Assuntos
Ar , Antracenos/síntese química , Membranas Artificiais , Água/química , Antracenos/química , Dimerização , Espectroscopia de Ressonância Magnética , Estrutura Molecular , Tamanho da Partícula , Fotoquímica , Espectrofotometria , Propriedades de Superfície , Raios X
2.
J Nanosci Nanotechnol ; 6(8): 2445-50, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17037854

RESUMO

Electric fields are used to guide the assembly of biomolecules in predefined geometric patterns on solid substrates. Local surface charges serve as templates to selectively position proteins on thin-film polymeric electret layers, thereby creating a basis for site-directed layered assembly of biomolecular structures. Charge patterns are created using the lithographic capabilities of an atomic force microscope, namely by applying voltage pulses between a conductive tip and the sample. Samples consist of a poly(methyl methacrylate) layer on a p-doped silicon support. Subsequently, the sample is developed in a water-in-oil emulsion, consisting of a dispersed aqueous phase containing biotin-modified immunoglobulinG molecules, and a continuous nonpolar, insulating oil phase. The electrostatic fields cause a net force of (di)electrophoretic nature on the droplet, thereby guiding the proteins to the predefined locations. Due to the functionalization of the immunoglobulinG molecules with biotin-groups, these patterns can now be used to initiate the localized layer-by-layer assembly of biomolecules based on the avidin-biotin mechanism. By binding 40 nm sized biotin-labelled beads to the predefined locations via a streptavidin linker, we verify the functionality of the previously deposited immunoglobulinG-biotin. All assembly steps following the initial deposition of the immunoglobulinG from emulsion can conveniently be conducted in aqueous solutions. Results show that pattern definition is maintained after immersion into aqueous solution.


Assuntos
Avidina/química , Biotina/química , Microscopia de Força Atômica/métodos , Nanopartículas/química , Nanotecnologia/métodos , Materiais Biocompatíveis/química , Biotinilação , Campos Eletromagnéticos , Imunoglobulina G/química , Polimetil Metacrilato/química , Silício/química , Eletricidade Estática , Estreptavidina/química , Propriedades de Superfície , Água/química
3.
Opt Lett ; 31(17): 2610-2, 2006 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-16902635

RESUMO

We demonstrate a low-cost, electrically tunable diffraction grating that is driven by a dielectric elastomer actuator. The angular tuning range of the polymer-based device is up to 118 mrad for the first diffracted order. The achievable grating period change of 32% is an improvement by more than a factor of 150 compared with existing analog tunable diffraction gratings based on hard materials. We show that in combination with a white light source, the presented diffraction grating can be used as a wavelength-adjustable luminous source. Such an illuminant has a potential application in inexpensive color displays that could reproduce all perceivable colors.


Assuntos
Biomimética/instrumentação , Elastômeros , Eletroquímica/instrumentação , Músculo Esquelético , Refratometria/instrumentação , Biomimética/métodos , Eletroquímica/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Refratometria/métodos