1.
Catheter Cardiovasc Interv ; 99(3): 593-600, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34241947

RESUMO

BACKGROUND: In patients at high bleeding risk (HBR), the LEADERS FREE (LF) trial established the safety and efficacy of a polymer-free drug coated (Biolimus-A9) stainless steel stent (SS-DCS) with 30 days of dual antiplatelet treatment (DAPT). In LEADERS FREE III, we studied a new cobalt-chromium thin-strut stent (CoCr-DCS) in HBR patients. METHODS: The CoCr-DCS shares all of the design features of the SS-DCS but has a CoCr stent platform with strut thickness of 84-88 µm. The primary safety endpoint was a composite of cardiac death, myocardial infarction (MI), and definite/probable stent thrombosis. The primary efficacy endpoint was clinically indicated target lesion revascularization. Outcomes were compared to those of LF (non-inferiority to SS-DCS for safety and superiority to SS-BMS for efficacy). Additional propensity-matched comparisons were performed to account for baseline differences. RESULTS: We recruited 401 HBR patients using identical criteria to the LF trial. At 1 year, the primary safety endpoint was reached by 31/401 (8.0%) of patients treated with the CoCr-DCS versus 35/401 (8.9%) for the propensity-matched cohort (HR: 0.89, [0.55-1.44], p < 0.001 for non-inferiority, 0.62 for superiority). The efficacy endpoint was reached by 16/401 (4.2%) of CoCr-DCS patients versus 41/401 (10.6%) in the propensity-matched cohort (HR: 0.4 [0.2:0.7]) (p = 0.007 for superiority). There was no statistical difference between CoCr-DCS and SS-DCS in terms of efficacy (HR: 1.46 [0.68-3.15], p = 0.33). CONCLUSIONS: The new thin-strut CoCr-DCS proved non-inferior to the SS-DCS for safety, and superior to the BMS for efficacy in HBR patients treated with 30 days of DAPT.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/terapia , Stents Farmacológicos/efeitos adversos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Polímeros , Desenho de Prótese , Fatores de Risco , Stents/efeitos adversos , Resultado do Tratamento
2.
N Engl J Med ; 373(21): 2038-47, 2015 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-26466021

RESUMO

BACKGROUND: Patients at high risk for bleeding who undergo percutaneous coronary intervention (PCI) often receive bare-metal stents followed by 1 month of dual antiplatelet therapy. We studied a polymer-free and carrier-free drug-coated stent that transfers umirolimus (also known as biolimus A9), a highly lipophilic sirolimus analogue, into the vessel wall over a period of 1 month. METHODS: In a randomized, double-blind trial, we compared the drug-coated stent with a very similar bare-metal stent in patients with a high risk of bleeding who underwent PCI. All patients received 1 month of dual antiplatelet therapy. The primary safety end point, tested for both noninferiority and superiority, was a composite of cardiac death, myocardial infarction, or stent thrombosis. The primary efficacy end point was clinically driven target-lesion revascularization. RESULTS: We enrolled 2466 patients. At 390 days, the primary safety end point had occurred in 112 patients (9.4%) in the drug-coated-stent group and in 154 patients (12.9%) in the bare-metal-stent group (risk difference, -3.6 percentage points; 95% confidence interval [CI], -6.1 to -1.0; hazard ratio, 0.71; 95% CI, 0.56 to 0.91; P<0.001 for noninferiority and P=0.005 for superiority). During the same time period, clinically driven target-lesion revascularization was needed in 59 patients (5.1%) in the drug-coated-stent group and in 113 patients (9.8%) in the bare-metal-stent group (risk difference, -4.8 percentage points; 95% CI, -6.9 to -2.6; hazard ratio, 0.50; 95% CI, 0.37 to 0.69; P<0.001). CONCLUSIONS: Among patients at high risk for bleeding who underwent PCI, a polymer-free umirolimus-coated stent was superior to a bare-metal stent with respect to the primary safety and efficacy end points when used with a 1-month course of dual antiplatelet therapy. (Funded by Biosensors Europe; LEADERS FREE ClinicalTrials.gov number, NCT01623180.).


Assuntos
Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Imunossupressores/administração & dosagem , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/uso terapêutico , Sirolimo/análogos & derivados , Idoso , Terapia Combinada , Doença da Artéria Coronariana/tratamento farmacológico , Método Duplo-Cego , Stents Farmacológicos/efeitos adversos , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Polímeros , Desenho de Prótese , Sirolimo/administração & dosagem , Stents/efeitos adversos
3.
Catheter Cardiovasc Interv ; 92(1): 106-114, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29521013

RESUMO

OBJECTIVES: To evaluate the clinical and health status outcomes of patients undergoing superficial femoral artery (SFA) revascularization using the Shape Memory Alloy Recoverable Technology (S.M.A.R.T.®) nitinol self-expanding stent through 3 years of follow-up. BACKGROUND: Limited long-term data are available describing the durability of benefits after femoropopliteal revascularization. METHODS: In a multicenter, prospective, core-lab adjudicated study, 250 subjects with de novo or restenotic femoropopliteal arterial lesions were treated with the S.M.A.R.T.® stent. The primary endpoint of target vessel patency, a composite of ultrasound-assessed patency and freedom from clinically driven target lesion revascularization (TLR), was evaluated through 3 years. Secondary endpoints included stent fracture and health status. Health status was measured using generic and disease-specific instruments, including the Peripheral Artery Questionnaire (PAQ). RESULTS: At 3-year follow-up, Kaplan-Meier estimated target vessel patency was 72.7%, freedom from clinically driven TLR was 78.5%, and the incidence of stent fracture was 3.6%. The PAQ summary score was markedly impaired at baseline (mean 37.3 ± 19.6 points) and improved substantially at 1 month (mean change from baseline of 31.4 points, 95% CI: 28.5-34.3; P < 0.001). Disease-specific health status benefits assessed by the PAQ were largely preserved through 3 years of follow-up (mean change from baseline, 28.0 points, 95% CI: 24.3-31.7; P < 0.0001). CONCLUSIONS: In patients undergoing revascularization for moderately complex SFA disease, use of the self-expanding S.M.A.R.T® stent was associated with a high rate of target vessel patency through 3 years and led to substantial and sustained health status benefits.


Assuntos
Procedimentos Endovasculares/instrumentação , Artéria Femoral/cirurgia , Doença Arterial Periférica/cirurgia , Artéria Poplítea/cirurgia , Qualidade de Vida , Stents Metálicos Autoexpansíveis , Idoso , Ligas , Constrição Patológica , Procedimentos Endovasculares/efeitos adversos , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Nível de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Doença Arterial Periférica/psicologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Intervalo Livre de Progressão , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Inquéritos e Questionários , Fatores de Tempo , Ultrassonografia de Intervenção , Estados Unidos , Grau de Desobstrução Vascular
4.
J Vasc Interv Radiol ; 26(1): 21-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25454735

RESUMO

PURPOSE: To assess safety and efficacy of the S.M.A.R.T. Vascular Stent System (Cordis Corp, Fremont, California) in obstructive superficial femoral artery (SFA) disease. MATERIALS AND METHODS: The single-arm, multicenter STROLL study (S.M.A.R.T. Nitinol Self-Expanding Stent in the Treatment of Obstructive Superficial Femoral Artery Disease) included 250 patients (250 lesions in SFA or proximal popliteal artery). The efficacy endpoint was primary patency defined by freedom from binary restenosis (peak systolic velocity ratio > 2.5) as derived by duplex ultrasound plus clinically driven target lesion revascularization (TLR) at 12 months. RESULTS: Mean age of patients was 67.7 years ± 10.3; 47.2% of patients had diabetes; distribution of Rutherford/Becker classes 2, 3, and 4 was 45.8%, 51.4%, and 2.8%. Mean lesion length and reference vessel diameter were 77.3 mm ± 35.3 and 4.9 mm ± 0.7, respectively (23.6% cases with total occlusions). The 30-day freedom from major adverse events (death, index limb amputation, clinically driven TLR) was 100%. The 1-year primary patency was 81.7% by Kaplan-Meier estimate. The presence of diabetes or total occlusion had no effect on primary patency. Ankle-brachial index was 0.4-0.8 in 84.6% of patients at baseline and improved to > 0.8 in 81.0% of patients at 12 months. The proportion of patients in Rutherford/Becker class 3-4 was reduced from 54.2% at baseline to 8.0% at 12 months. Four patients (2.0%) experienced single-stent strut fracture (type I) at 1 year, without associated loss of stent patency. CONCLUSIONS: The S.M.A.R.T. Vascular Stent System proved to be safe and effective for endovascular treatment of obstructive SFA and proximal popliteal artery disease, based on 1-year vessel patency and associated hemodynamic and clinical improvements.


Assuntos
Aterosclerose/diagnóstico por imagem , Aterosclerose/terapia , Artéria Femoral/diagnóstico por imagem , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Stents , Idoso , Ligas , Constrição Patológica , Feminino , Seguimentos , Humanos , Masculino , Resultado do Tratamento , Ultrassonografia de Intervenção
5.
Clin Res Cardiol ; 110(2): 162-171, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32440723

RESUMO

AIMS: To compare the outcomes of patients undergoing non-cardiac surgery (NCS) after PCI with either a drug-coated stent (DCS) or a bare-metal stent (BMS), followed by 1-month dual antiplatelet therapy and to explore the impact of the timing of NCS. METHODS: This is a subgroup analysis of the LEADERS FREE trial. The primary safety end point was a composite of cardiac death, myocardial infarction, or stent thrombosis, and the primary efficacy end point was clinically driven target lesion revascularization (TLR). RESULTS: Out of 2432 patients included in the LEADERS FREE trial, 278 (11.4%) underwent NCS within 1 year after PCI. Among NCS patients, the 1-year safety end point was numerically lower with DCS; however, this difference was not significant as compared to BMS (4.7% vs. 10.1%, HR: 0.459 [0.178-1.183], p = 0.099), clinically driven TLR was significantly lower after DCS (2.4% vs. 8.3%, HR: 0.281 [0.079-0.996], p = 0.036), and BARC 3-5 bleeding was similar with DCS vs. BMS (10.2% vs. 7.5%, p = 0.438). In patients treated with BMS, NCS within 3 months after PCI was associated with higher incidence of the safety end point than NCSs performed later: 14.9% vs. 4.4%, HR: 3.586 [1.012-12.709], p = 0.034. The timing of surgery had no impact on patients treated with DCS (4.7% vs. 4.7%, p = 0.947). CONCLUSIONS: Among patients undergoing NCS after PCI, DCS-treated patients had a lower probability of clinically driven TLR compared with BMS. However, there was no significant difference in the occurrence of the primary composite safety end point or bleeding complications. Early NCS after BMS-PCI was associated with impaired safety, while the timing of NCS had no such influence after DCS implantation.


Assuntos
Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Polímeros , Sirolimo/farmacologia , Procedimentos Cirúrgicos Operatórios , Idoso , Doença da Artéria Coronariana/complicações , Feminino , Humanos , Masculino , Prognóstico , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco
6.
EuroIntervention ; 17(3): 233-239, 2021 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-33433389

RESUMO

BACKGROUND: The BioFreedom drug-coated stent with a stainless steel platform (BF-SS) has been demonstrated to be efficacious in patients at high bleeding risk and receiv-ing only one-month dual antiplatelet therapy. AIMS: The aim of this study was to evaluate the efficacy of the new BioFreedom Ultra drug-coated stent with a thin-strut cobalt-chromium platform (BF-CoCr) compared to the BF-SS in an all-comers population undergoing percutaneous coronary intervention (PCI). METHODS: This was a prospective, multicentre, non-inferiority trial. The primary endpoint was in-stent late lumen loss (LLL) as determined by quantitative coronary angiography at nine-month follow-up. Clinical evaluation was performed at one year. RESULTS: A total of 200 patients were randomised (1:1) to either the BF-CoCr or the BF-SS stent at eight centres in Spain and Denmark. Baseline clinical and lesion characteristics were similar between the groups. Mean age was 66 years and 23% were female. The mean number of stents implanted per patient was 1.5. At nine-month follow-up, mean in-stent LLL was 0.34±0.49 mm in the BF-CoCr group versus 0.29±0.37 mm in the BF-SS group, p=0.005 for non-inferiority. At one year, target lesion failure was similar between the groups (7.3% in BF-CoCr vs 9.3% in the BF-SS group; p=0.60). CONCLUSIONS: The BF-CoCr was non-inferior to the BF-SS in terms of in-stent LLL at nine months. Larger studies powered for clinical endpoints are warranted to compare the efficacy of this new platform with currently available DES.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Idoso , Feminino , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Estudos Prospectivos , Desenho de Prótese , Sirolimo/uso terapêutico , Espanha , Stents , Resultado do Tratamento
7.
Clin Res Cardiol ; 108(1): 31-38, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29951803

RESUMO

OBJECTIVE: Diabetics are at increased risk after stent implantation and potentially sensitive to the type of stent and dual anti-platelet therapy (DAPT). The randomized, double-blind LEADERS FREE trial compared 2432 patients at high bleeding risk (HBR) receiving either a polymer-free BA9-coated stent (DCS) or a bare metal stent (BMS) with 1 month of DAPT, and showed superior safety and efficacy of the DCS at 2 years. We report outcomes at 2 years of the pre-specified diabetic subgroup. METHODS AND RESULTS: The diabetic sub-group comprised 805 (33.1%) patients; 262 (10.8%) were insulin-dependent (IDDM). Compared to non-diabetics, diabetics were younger and had more risk factors and multi-vessel disease. They suffered higher rates of death (15.6 vs. 12.2%, p = 0.01), cardiac death (8.3 vs. 5.9%, p = 0.02), myocardial infarction (MI) (11.1 vs. 7.8%, p = 0.009) and definite/probable stent thrombosis (3.1 vs. 1.7%, p = 0.01), but rates of clinically-indicated TLR (9.1 vs. 9.5%, p = 0.93) and BARC 3-5 bleeding (10.2 vs. 8.4%, p = 0.20) were comparable. Compared to diabetic patients treated with a BMS, diabetic DCS recipients required less clinically driven TLR (6.3 vs. 12.2%, p = 0.006). The primary safety endpoint (cardiac death, MI, definite/probable stent thrombosis) occurred numerically less frequently in the DCS group (14.9 vs. 19.7%, p = 0.10), and was significantly lower in IDDM patients (13.8 vs. 25.4%, p = 0.03). BARC 3-5 was similar for patients treated with DCS (9.9%) and BMS (10.5%, p = 0.84). CONCLUSIONS: In diabetic HBR patients, DCS significantly reduced re-intervention rates over BMS, and showed a strong trend towards a safety benefit at 2 years. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov number: NCT01623180.


Assuntos
Doença da Artéria Coronariana/cirurgia , Trombose Coronária/prevenção & controle , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Hemorragia Pós-Operatória/epidemiologia , Idoso , Método Duplo-Cego , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Polímeros , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
Am J Cardiol ; 101(11): 1550-9, 2008 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-18489932

RESUMO

The differential safety and efficacy profiles of sirolimus-eluting stents when implanted in patients with multivessel coronary artery disease who have increased body mass indexes (BMIs) compared with those with normal BMIs are largely unknown. This study evaluated the impact of BMI on 1-year outcomes in patients with multivessel coronary artery disease treated with sirolimus-eluting stents as part of the Arterial Revascularization Therapies Study Part II (ARTS II). From February to November 2003, 607 patients were included at 45 centers; 176 patients had normal BMIs (<25 kg/m(2)), 289 were overweight (> or =25 and < or =30 kg/m(2)), and 142 were obese (>30 kg/m(2)). At 30 days, the cumulative incidence of the primary combined end point of death, myocardial infarction, cerebrovascular accident, and repeat revascularization (major adverse cardiac and cerebrovascular events) was 3.4% in the group with normal BMIs, 3.1% in overweight patients, and 2.8% in obese patients (p = 0.76). At 1 year, the cumulative incidence of major adverse cardiac and cerebrovascular events was 10.8%, 11.8%, and 7.0% in the normal BMI, overweight, and obese groups, respectively (p = 0.31). In conclusion, BMI had no impact on 1-year clinical outcomes in patients with multivessel coronary artery disease treated with sirolimus-eluting stents in ARTS II.


Assuntos
Índice de Massa Corporal , Materiais Revestidos Biocompatíveis , Doença das Coronárias/cirurgia , Revascularização Miocárdica/instrumentação , Obesidade/complicações , Sirolimo/farmacologia , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença das Coronárias/complicações , Doença das Coronárias/mortalidade , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Mortalidade Hospitalar/tendências , Humanos , Imunossupressores/farmacologia , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
9.
EuroIntervention ; 14(4): e418-e425, 2018 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-29790477

RESUMO

AIMS: The LEADERS FREE trial has demonstrated that a polymer-free Biolimus A9-coated stent (BA9-DCS) is superior to a bare metal stent (BMS) for high bleeding risk (HBR) patients when treated with one month of dual antiplatelet therapy (DAPT). This analysis aimed to determine the impact of PCI procedure complexity on the two-year results. METHODS AND RESULTS: Six hundred and sixty-seven (667) patients enrolled in the LEADERS FREE (BA9-DCS 346, BMS 321) underwent a complex PCI, defined by one or more of eight characteristics: total stent length ≥60 mm, ≥3 vessels or lesions treated, ≥3 stents implanted, bifurcation lesion treated with ≥2 stents, chronically occluded, restenotic or saphenous vein graft lesion. Patients undergoing complex PCI were older, more often male, and presented with more ACS, diabetes, renal insufficiency, anaemia and multivessel disease. They derived major benefit from DCS over BMS for safety (16.2% vs. 21.7%, HR 0.70 [0.49-0.99], p<0.05) and for efficacy (10.8% vs. 18.1%, HR 0.54 [0.35-0.83], p<0.005). For the 1,746 patients with non-complex PCI, DCS demonstrated superior efficacy (5.3% vs. 9.9%, HR 0.52 [0.36-0.75], p<0.001, p for interaction NS) and similar safety to BMS (11.1% vs. 12.6%, NS, p for interaction NS). CONCLUSIONS: Compared to BMS, the BA9-DCS maintained both efficacy and safety benefits when used in complex PCI procedures.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Masculino , Inibidores da Agregação Plaquetária , Polímeros , Sirolimo/análogos & derivados , Resultado do Tratamento
10.
EuroIntervention ; 14(7): 780-788, 2018 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-29901444

RESUMO

AIMS: This study aimed to establish the early healing and neointimal transformation profile of the new polymer-free BioFreedom stent through sequential optical coherence tomography (OCT) within the first nine months following stent implantation. METHODS AND RESULTS: We randomly assigned 104 BFS recipients to one of five groups with angiography and OCT follow-up at 1, 2, 3, 4, or 5 months, together with another follow-up for all at nine months. The primary endpoint was the degree of OCT-detected strut coverage at nine months. From 1, 2, 3, 4, and 5 months, median neointimal strut coverage increased from 85.8, 87.0, 88.6, 96.8 to 97.1%, respectively, to 99.6% (IQR 98.2-99.9) at nine months. At nine months, median percent neointimal volume was 13.0% and angiographic late lumen loss was 0.21±0.30 mm. Major adverse cardiac events (MACE) were limited to one non-cardiac death, one non-ST-elevation myocardial infarction not related to BFS, and two target lesion revascularisations without stent thrombosis (MACE rate 4.0%). CONCLUSIONS: Neointimal strut coverage of the BFS was rapid and the BFS was shown to be clinically safe and effective.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Angiografia Coronária , Humanos , Polímeros , Estudos Prospectivos , Desenho de Prótese , Sirolimo/análogos & derivados , Tomografia de Coerência Óptica , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS