Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38864592

RESUMO

Restorative material selection has become increasingly challenging due to the speed of new developments in the field of dental material science. The present narrative review gives an overview of the current indications for implant abutments and restoration materials for provisional and definitive implant-supported fixed dental prostheses in partially edentulous patients. For single implant restorations, titanium base abutments for crowns are suggested as an alternative to the conventional stock- and customized abutments made out of metal or zirconia. They combine the mechanical stability of a metallic connection with the esthetic potential of ceramics. For multiple-unit restorations, conical titanium bases especially designed for bridges are recommended, to compensate for deviating implant insertion axes and angulations. Even though titanium base abutments with different geometries and heights are available, certain clinical scenarios still benefit from customized titanium abutments. Indications for the definitive material in fixed implant restorations depend on the region of tooth replacement. In the posterior (not esthetically critical) zone, ceramics such as zirconia (3-5-Ymol%) and lithium-disilicate are recommended to be used in a monolithic fashion. In the anterior sector, ceramic restorations may be buccally micro-veneered for an optimal esthetic appearance. Lithium-disilicate is only recommended for single-crowns, while zirconia (3-5-Ymol%) is also recommended for multiple-unit and cantilever restorations. Attention must be given to the specific mechanical properties of different types of zirconia, as some feature reduced mechanical strengths and are therefore not indicated for all regions and restoration span lengths. Metal-ceramics remain an option, especially for cantilever restorations.

2.
J Esthet Restor Dent ; 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38334315

RESUMO

OBJECTIVES: Aim of this study was to assess survival rates, radiographic, and pink esthetic outcomes of a bone-level-tapered (BLT) implant following immediate or early implant placement. MATERIALS AND METHODS: Patients in need of tooth extraction and one implant in the anterior or premolar area were recruited in five centers. Patients were randomly assigned to the immediate or early placement protocol. Implants were restored with all-ceramic crowns cemented to titanium-base-abutments. Radiographic bone levels, implant stability quotient (ISQ), and pink esthetic outcomes were assessed. Data were analyzed descriptively. Level of significance was set at 0.05. Differences between groups were tested using Wilcoxon-signed-rank and Mann-Whitney-U test as nonparametric tests. RESULTS: A total of 60 patients received 60 BLT implants (Institut Straumann). At 12-months, 59 implants (98.3%) were osseointegrated. The mean distance from implant shoulder to first bone-to-implant contact was 0.15 ± 0.59 mm without significant differences between the groups. Median ISQ values increased from 75.5 to 78.5. A mean buccal recession of 0.1 ± 0.70 mm occurred with no difference between groups. The mean papilla height gain in both groups was 0.5 ± 1.47 mm mesially and 0.4 ± 1.36 mm distally. CONCLUSIONS: After 1 year, immediately and early placed BLT implants exhibit similar bone level changes, ISQ values, and pink esthetic outcomes. CLINICAL SIGNIFICANCE: The present research contributes to the knowledge on clinical outcomes of immediately and early placed BLT implants restored with buccally microveneered ceramic single crowns out of two different ceramic materials. The research shows that similar esthetic and radiographic outcomes can be reached by means of immediate implant placement compared to the conventional early placement protocol. The improvement of esthetic soft-tissue parameters over time was shown for both implant placement protocols.

3.
Clin Oral Implants Res ; 34(1): 56-65, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36321877

RESUMO

OBJECTIVES: To investigate survival rates, technical and biologic outcomes of buccally micro-veneered all-ceramic single implant crowns. MATERIAL AND METHODS: Sixty subjects randomly received immediately or early placed implants. Crowns out of lithium-disilicate (n = 30) and zirconia-ceramic (n = 30) were bonded to titanium-base-abutments. Restorations were inspected at baseline (BL) and during follow-up visits (6, 12 months). Technical and biologic parameters were recorded. Data were analysed descriptively. Differences between groups were tested with Student's t-test. Paired T-test was used when comparing data from the same implant or tooth over time. Linear model repeated measures were used to test differences between materials over time. Differences in counts were evaluated using Pearson Chi-square test. The level of significance was at p < .05. RESULTS: After a mean observation time of 13.2 ± 2.4 months, 54 restorations were re-examined. The implant survival rate was 98.3%, and the restoration survival rate was 100%. One early implant failure occurred. Two minor chippings occurred in lithium-disilicate restorations. No chippings or fractures occurred in any zirconia restorations at 1 year (0%). The technical complication rate was 3.7%, with 7.7% complications among the lithium-disilicate restorations and no differences between the two materials (p = .558). At 1-year follow-up, mean Bleeding on Probing (BOP) was higher at implants (0.27 ± 0.3) than adjacent teeth (0.17 ± 0.18) (p = .046) with no differences between materials (p = .36). Differences in pocket probing depth (PPD) between implants and adjacent teeth were significant (p < .01). Jemt Index improved significantly from BL to 1-y-follow-up (p < .001). CONCLUSIONS: Preliminary results were good, suggesting that the ceramic type does not impact technical and biologic parameters.


Assuntos
Produtos Biológicos , Titânio , Humanos , Projetos Piloto , Lítio , Falha de Restauração Dentária , Porcelana Dentária , Coroas , Zircônio , Cerâmica , Dente Suporte
4.
Artigo em Inglês | MEDLINE | ID: mdl-37929698

RESUMO

AIM: This study aimed to investigate the influence of titanium base (ti-base) abutment macro- and micro-geometry on the mechanical stability of polymer-infiltrated ceramic network (PICN) screw-retained implant-supported single crowns (iSCs). MATERIALS AND METHODS: Twelve specimens per group were used, comprising six different implant/ti-base abutment combinations restored with PICN iSCs: Nb-T (gingival height [GH]: 1.5 mm, prosthetic height [PH]: 4.3 mm), CC (GH: 0.8 mm, PH: 4.3 mm), CC-P (GH: 0.8 mm, PH: 7 mm), Nb-V (GH: 1.5 mm, PH: 6 mm), St (GH: 1.5 mm, PH: 5.5 mm), and Th (GH: 0.5 mm, PH: 9 mm). The specimens underwent thermo-mechanical aging, and those that survived were subsequently subjected to static loading until failure. The data were analyzed using a one-way ANOVA test followed by Tukey post hoc test (α = .05). RESULTS: All specimens survived thermo-mechanical aging without complications, namely, visible cracks, debonding, or screw loosening. Th group demonstrated the highest strength values among all the groups, with significant differences compared to Nb-T (p < .05), CC (p < .001), and St (p < .001). Additionally, CC-P group exhibited significantly superior fracture strength results compared to CC (p < .05) and St (p < .05). CONCLUSION: The choice of ti-base, particularly prosthetic height, had a significant influence on fracture resistance of PICN iSCs. Nevertheless, the height or geometrical features of the ti-base did not exhibit a significant influence on the mechanical behavior of the iSC/ti-base assembly under thermomechanical loading, as all specimens withstood the aging without complication or failure.

5.
Clin Oral Implants Res ; 34(9): 999-1013, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37403575

RESUMO

OBJECTIVES: To test whether soft tissue volume augmentation using a collagen matrix (VCMX) leads to noninferior results in terms of gain of mucosal thickness at single implant sites, compared to connective tissue grafts (SCTG). METHODS: The study was designed as a multi-center randomized controlled clinical trial. Subjects in need of soft tissue volume augmentation at single tooth implant sites were consecutively recruited at nine centers. The deficient mucosal thickness at the implant sites (one per patient) was augmented by applying either a VCMX or a SCTG. Patients were examined at 120 days (abutment connection = primary endpoint), 180 days (final restoration), and 360 days (1-year after insertion of the final restoration). Outcome measures included: transmucosal probing of the mucosal thickness (crestal = primary outcome), profilometric measurements of the tissue volume, and patient-reported outcome measures (PROMs). RESULTS: Out of the 88 patients, 79 attended the one-year follow-up. The median increase of the crestal mucosal thickness between pre-augmentation and 120 days was 0.3 ± 2.1 mm in the VCMX group and 0.8 ± 1.6 mm in the SCTG group (p = .455). Non-inferiority of the VCMX compared to the SCTG was not observed. The respective numbers at the buccal aspect amounted to 0.9 ± 2.0 mm (VCMX) and 1.1 ± 1.4 mm (SCTG; p = .431). PROMs including pain perception favored the VCMX group. CONCLUSION: It remains inconclusive whether soft tissue augmentation using a VCMX is noninferior to SCTG in terms of crestal mucosal thickening at single implant sites. However, the use of collagen matrices favors PROMs especially pain perception, while achieving similar buccal volume gains along with comparable clinical and aesthetic parameters to SCTG.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Humanos , Gengiva/cirurgia , Colágeno/uso terapêutico , Tecido Conjuntivo/transplante , Resultado do Tratamento
6.
J Esthet Restor Dent ; 35(1): 262-269, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36478351

RESUMO

OBJECTIVE: This study aims to validate the standardized procedure for designing soft tissue substitutes (STS) adapted to optimally fit single-tooth defects in the anterior jaws and double-tooth defects in the posterior jaw and to compare mathematically modeled average shapes. MATERIALS AND METHODS: Casts from 35 patients with 17 single-tooth defects in anterior region and 21 double-tooth defects in posterior region were scanned. STS were designed and sectioned in 3D slices meshes. Thickness values were documented respecting mesial-distal and buccal-lingual orientations. Graphs were embedded into images, and hierarchical clustering was applied to group STS according to shape and thickness. RESULTS: STS clustered into two groups per defect type. For anterior single defects, STS (n = 4) were either a small and thin oval: 7 mm buccal-lingual, 4-5 mm mesial-distal direction and 1.1-1.5 mm thick or a larger oval (n = 13): 9 mm buccal-lingual, 5-7 mm mesial-distal and 1.6 m thick. For posterior double tooth defects, STS (n = 10) were either narrow, long and thick: 6-7 mm buccal-lingual, 16-20 mm mesial-distal and 2.2 thick or a wide, thinner rectangle (n = 11): 9-11 mm buccal-lingual, 12-14 mm mesial-distal and 1.1-1.5 mm thick. CONCLUSIONS: The study validated the standardized digital method to design grafts for soft tissue volume augmentation and identified four average shapes for anterior single-tooth and posterior double-tooth soft tissue defects. CLINICAL SIGNIFICANCE: We developed and validated a standardized digital method to design an optimal geometrical shape of a soft tissue substitute for oral volume augmentation and combined it with mathematical modeling to identify average shapes for single-interior, and double-posterior tooth defects. The identified average shapes offer the possibility to produce better-fitted xenografts or synthetic STS blocks requiring minimal chair-side adaptation leading to reduced clinical time and patient discomfort and potentially improving soft tissue volume augmentation outcomes.


Assuntos
Dentes Fusionados , Dente , Humanos , Engenharia Tecidual
7.
J Esthet Restor Dent ; 34(1): 104-116, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34953109

RESUMO

OBJECTIVE: This scoping review aimed to present an overview of the literature on communication tools in esthetic dentistry. A variety of communication tools have been proposed to include patients in the shared decision-making (SDM) workflow. Only little is known about implementing communication tools in dentistry and their impact on patient communication and patient satisfaction. A systematic literature search was performed in Medline, Embase, Cochrane, and World of Science to identify if communication tools have an impact on patient satisfaction. MATERIAL AND METHODS: The search included studies from January 1, 2000 to March 3, 2020 published in English, focusing on patient communication tools and patient satisfaction in esthetic dentistry. RESULTS: Out of 6678 records, 53 full-texts were examined. Ten studies were included. Data of the included studies were extracted systematically and subsequently analyzed. All studies found that patient communication utilizing specific communication tools positively impacted either patient satisfaction, patient-dentist relationship, information retention, treatment acceptance, quality of care or treatment outcome. CONCLUSIONS: Additional communication tools besides conventional verbal communication are able to enhance patient satisfaction, improve quality of care and establish a better patient-dentist relationship. It seems essential to further develop standardized communication tools for SDM in dental medicine, which will allow the comparison of research on this topic. CLINICAL SIGNIFICANCE: This scoping review shows the importance of patient involvement in the decision-making process for improved patient satisfaction with esthetic dental treatments. With an increased implementation of communication tools, patient satisfaction and SDM may further improve in the future.


Assuntos
Participação do Paciente , Satisfação do Paciente , Comunicação , Tomada de Decisões , Humanos
8.
Clin Oral Implants Res ; 32(11): 1263-1273, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34448240

RESUMO

OBJECTIVES: Soft-tissue volume augmentation treatments do not provide the satisfactory long-term functional and esthetic outcomes. The aim of the study was to develop a standardized digital procedure to design individual soft-tissue substitutes (STS) and apply mathematical modeling to obtain average shape STS for single posterior tooth defects. MATERIAL AND METHODS: Thirty-three casts from 30 patients were scanned. STS were designed with a computer-aided design software and a systematic procedure standardized the measurements across all STS using 3D-analysis software. The occlusal, mesial-distal, and buccal-lingual planes were defined to partition, each STS and produce a mesh. The thickness values of each 3D slice were documented in a coordinate system chart to generate a scatter graph. Graphs were embedded into images (Orange software) and images were analyzed via hierarchical clustering. RESULTS: Three STS groups were identified according to shape. Two shapes corresponded to the maxilla defects: a square (n = 13) with dimensions of 10 mm in a lingual-buccal (length) and 7-10 mm in a mesial-distal (width) direction; a rectangle (n = 11) of 11 mm in length and 4-7 mm in width. The average shape for mandible defects (n = 9) was smaller (6-8 mm in length, 5-10 mm in width). The highest thickness in all STS was in the buccal portion, above the alveolar ridge, with median values of 2 mm. The lowest thickness of 0.2 mm was at the edges. CONCLUSIONS: The study developed novel methodology to design customized, as well as average shape STS for volume augmentation. Future STS harboring adapted geometry might increase volume augmentation efficiency and accuracy, while reducing surgical time.


Assuntos
Aumento do Rebordo Alveolar , Dente , Desenho Assistido por Computador , Estética Dentária , Humanos , Mandíbula/cirurgia , Maxila/cirurgia
9.
Clin Oral Implants Res ; 32 Suppl 21: 174-180, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34145925

RESUMO

OBJECTIVES: The task of working Group 2 at the 6th Consensus Meeting of the European Association for Osseointegration was to comprehensively assess the effects of soft tissue augmentation procedures at dental implant sites on clinical, radiographic and patient-reported outcome measures (PROMs) including an overview on available outcome measures and methods of assessment. MATERIALS AND METHODS: Three systematic reviews and one critical review were performed in advance on (i) the effects of soft tissue augmentation procedures on clinical, radiographic and aesthetic outcomes, (ii) reliability and validity of outcome measures and methods of assessment and (iii) PROMs applied in clinical studies for soft tissue augmentation procedures at dental implant sites. Major findings, consensus statements, clinical recommendations and implications for future research were discussed in the group and approved during the plenary sessions. RESULTS: The four reviews predominantly revealed: Soft tissue augmentation procedures in conjunction with immediate and delayed implant placement result in superior aesthetic outcomes compared to no soft tissue augmentation in the zone of aesthetic priority. Soft tissue augmentation procedures have a limited effect on marginal bone level changes compared to implant sites without soft tissue augmentation. Clinically relevant parameters (gingival index, mucosal recession) and plaque control improve at implant sites when the width of keratinised mucosa is increased. A variety of aesthetic indices have been described with good reliability. Pink Esthetic Score and Complex Esthetic Index are the most validated aesthetic indices for single implants, though. Superimposed digital surface scans are most accurate to assess profilometric tissue changes. PROMs following soft tissue augmentation procedures have been assessed using various forms of questionnaires. Soft tissue augmentation had a limited effect on PROMs. CONCLUSIONS: Soft tissue augmentation procedures are widely applied in conjunction with implant therapy. Depending on the indication of these interventions, clinical, radiographic and aesthetic outcomes may improve, whereas the effect on PROMs is limited.


Assuntos
Implantes Dentários , Estética Dentária , Humanos , Reprodutibilidade dos Testes
10.
Clin Oral Implants Res ; 29 Suppl 16: 184-198, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30328185

RESUMO

OBJECTIVES: The aim of the present review was to compare the outcomes, that is, survival and complication rates of zirconia-ceramic and/or monolithic zirconia implant-supported fixed dental prostheses (FDPs) with metal-ceramic FDPs. MATERIALS AND METHODS: An electronic MEDLINE search complemented by manual searching was conducted to identify randomized controlled clinical trials, prospective cohort studies and retrospective case series on implant-supported FDPs with a mean follow-up of at least 3 years. Patients had to have been examined clinically at the follow-up visit. Assessment of the identified studies and data extraction was performed independently by two reviewers. Failure and complication rates were analyzed using robust Poisson regression models to obtain summary estimates of 5-year proportions. RESULTS: The search provided 5,263 titles and 455 abstracts. Full-text analysis was performed for 240 articles resulting in 19 studies on implant FDPs that met the inclusion criteria. The studies reported on 932 metal-ceramic and 175 zirconia-ceramic FDPs. Meta-analysis revealed an estimated 5-year survival rate of 98.7% (95% CI: 96.8%-99.5%) for metal-ceramic implant-supported FDPs, and of 93.0% (95% CI: 90.6%-94.8%) for zirconia-ceramic implant-supported FDPs (p < 0.001). Thirteen studies including 781 metal-ceramic implant-supported FDPs estimated a 5-year rate of ceramic fractures and chippings to be 11.6% compared with a significantly higher (p < 0.001) complication rate for zirconia implant-supported FDPs of 50%, reported in a small study with 13 zirconia implant-supported FDPs. Significantly (p = 0.001) more, that is, 4.1%, of the zirconia-ceramic implant-supported FDPs were lost due to ceramic fractures compared to only 0.2% of the metal-ceramic implant-supported FDPs. Detailed analysis of factors like number of units of the FDPs or location in the jaws was not possible due to heterogeneity of reporting. No studies on monolithic zirconia implant-supported FDPs fulfilled the inclusion criteria of the present review. Furthermore, no conclusive results were found for the aesthetic outcomes of both FDP-types. CONCLUSION: For implant-supported FDPs, conventionally veneered zirconia should not be considered as material selection of first priority, as pronounced risk for framework fractures and chipping of the zirconia veneering ceramic was observed. Monolithic zirconia may be an interesting alternative, but its clinical medium- to long-term outcomes have not been evaluated yet. Hence, metal ceramics seems to stay the golden standard for implant-supported multiple-unit FDPs.


Assuntos
Cerâmica/química , Implantes Dentários , Materiais Dentários/química , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Prótese Parcial Fixa , Zircônio/química , Bases de Dados Factuais , Falha de Restauração Dentária , Estética Dentária , Humanos , Ligas Metalo-Cerâmicas/química , Análise de Sobrevida
11.
Clin Oral Implants Res ; 29 Suppl 16: 199-214, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30328190

RESUMO

OBJECTIVES: The aim of the present systematic review was to analyze the survival and complication rates of zirconia-based and metal-ceramic implant-supported single crowns (SCs). MATERIALS AND METHODS: An electronic MEDLINE search complemented by manual searching was conducted to identify randomized controlled clinical trials, prospective cohort and retrospective case series on implant-supported SCs with a mean follow-up time of at least 3 years. Patients had to have been clinically examined at the follow-up visit. Assessment of the identified studies and data extraction was performed independently by two reviewers. Failure and complication rates were analyzed using robust Poisson's regression models to obtain summary estimates of 5-year proportions. RESULTS: The search provided 5,263 titles and 455 abstracts, full-text analysis was performed for 240 articles, resulting in 35 included studies on implant-supported crowns. Meta-analysis revealed an estimated 5-year survival rate of 98.3% (95% CI: 96.8-99.1) for metal-ceramic implant supported SCs (n = 4,363) compared to 97.6% (95% CI: 94.3-99.0) for zirconia implant supported SCs (n = 912). About 86.7% (95% CI: 80.7-91.0) of the metal-ceramic SCs (n = 1,300) experienced no biological/technical complications over the entire observation period. The corresponding rate for zirconia SCs (n = 76) was 83.8% (95% CI: 61.6-93.8). The biologic outcomes of the two types of crowns were similar; yet, zirconia SCs exhibited less aesthetic complications than metal-ceramics. The 5-year incidence of chipping of the veneering ceramic was similar between the material groups (2.9% metal-ceramic, 2.8% zirconia-ceramic). Significantly (p = 0.001), more zirconia-ceramic implant SCs failed due to material fractures (2.1% vs. 0.2% metal-ceramic implant SCs). No studies on newer types of monolithic zirconia SCs fulfilled the simple inclusion criteria of 3 years follow-up time and clinical examination of the present systematic review. CONCLUSION: Zirconia-ceramic implant-supported SCs are a valid treatment alternative to metal-ceramic SCs, with similar incidence of biological complications and less aesthetic problems. The amount of ceramic chipping was similar between the material groups; yet, significantly more zirconia crowns failed due to material fractures.


Assuntos
Cerâmica/química , Coroas , Implantes Dentários , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Bases de Dados Factuais , Materiais Dentários/química , Estética Dentária , Humanos , Ligas Metalo-Cerâmicas/química , Análise de Sobrevida , Zircônio
12.
Clin Oral Implants Res ; 29 Suppl 18: 160-183, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30306682

RESUMO

OBJECTIVES: The objective of this systematic review was to assess the influence of implant-abutment connection and abutment material on the outcome of implant-supported single crowns (SCs) and fixed dental prostheses (FDPs). METHODS: An electronic Medline search complemented by manual searching was conducted to identify randomized controlled clinical trials, prospective and retrospective studies with a mean follow-up time of at least 3 years. Patients had to have been examined clinically at the follow-up visit. Failure and complication rates were analyzed using robust Poisson regression, and comparisons were made with multivariable Poisson regression models. RESULTS: The search provided 1511 titles and 177 abstracts. Full-text analysis was performed for 147 articles resulting in 60 studies meeting the inclusion criteria. Meta-analysis of these studies indicated an estimated 5-year survival rate of 97.6% for SCs and 97.0% for FDPs supported by implants with internal implant-abutment connection and 95.7% for SCs and 95.8% for FDPs supported by implants with external connection. The 5-year abutment failure rate ranged from 0.7% to 2.8% for different connections with no differences between the types of connections. The total number of complications was similar between the two connections, yet, at external connections, abutment or occlusal screw loosening was more predominant. Ceramic abutments, both internally and externally connected, demonstrated a significantly higher incidence of abutment fractures compared with metal abutments. CONCLUSION: For implant-supported SCs, both metal and ceramic abutments with internal and external connections exhibited high survival rates. Moreover, implant-supported FDPs with metal abutments with internal and external connections for also showed high survival rates.


Assuntos
Dente Suporte , Projeto do Implante Dentário-Pivô , Implantação Dentária Endóssea , Prótese Dentária Fixada por Implante , Cerâmica/efeitos adversos , Cerâmica/uso terapêutico , Coroas/efeitos adversos , Dente Suporte/efeitos adversos , Projeto do Implante Dentário-Pivô/efeitos adversos , Implantação Dentária Endóssea/efeitos adversos , Implantação Dentária Endóssea/métodos , Prótese Dentária Fixada por Implante/efeitos adversos , Falha de Restauração Dentária , Humanos , Metais/efeitos adversos , Metais/uso terapêutico
13.
J Prosthet Dent ; 119(6): 893-896, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29042114

RESUMO

Adhesive cementation is a useful procedure not only for cementing restorations onto teeth but also for attaching new ceramic restorations to existing restorations to improve their esthetics and/or function. This clinical report presents a technique for modifying an existing nonsatisfactory implant-supported fixed dental prosthesis by means of adhesively cemented veneers and onlays bonded to the pre-existing metal-ceramic surface with resin cement. This modification may avoid the replacement of the fixed dental prosthesis, reducing both treatment costs and time while fulfilling the patient's demands.


Assuntos
Prótese Dentária , Idoso , Falha de Restauração Dentária , Facetas Dentárias , Revestimento de Dentadura , Estética Dentária , Feminino , Humanos , Cimentos de Resina
14.
Materials (Basel) ; 16(16)2023 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-37629928

RESUMO

BACKGROUND: A prospective multi-center randomized controlled clinical trial was performed to digitally analyze tissue volume changes in immediately and early placed implants with simultaneous bone augmentation restored with two different all-ceramic materials. METHODS: A total of 60 patients received 60 bone-level tapered implants (BLT, Straumann AG) immediately (n = 30) or early placed, 8-10 weeks after tooth extraction, (n = 30). Implants were restored with all-ceramic single crowns fabricated out of zirconia (Lava Plus, 3M), or lithium disilicate (E.max CAD, Ivoclar Vivadent AG) bonded to titanium base abutments (Variobase for Cerec, Straumann AG). Impressions were taken at baseline (BL), 6 and 12 months, and STL data were used to define an area of interest (AOI) to analyze peri-implant volume changes and midfacial recessions. RESULTS: For immediate placement, a mean volume loss of -5.56 mm3 (±5.83 mm3) was found at 6 months, and of -6.62 mm3 (±6.56 mm3) at 12 months. For early placement, a mean volume loss of -1.99 mm3 (±5.82 mm3) at 6 months, and of -3.7 mm3 (±5.62 mm3) at 12 months was found. The differences in volume loss at 12 months between the two implant placement protocols were significant (p = 0.005). In both groups, mean midfacial recessions of 0.48 mm (±0.52) occurred. CONCLUSIONS: A more pronounced peri-implant volume loss can be expected 12 months after immediate implant placement compared with early placement.

15.
Materials (Basel) ; 15(17)2022 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-36079517

RESUMO

(1) Background: An alternative material to precious metal alloys are non-precious metal alloys. The material properties of these are different and, therefore, their clinical, biological and mechanical behaviors may also differ. Hence, the purpose of this in vivo investigation was to analyze the clinical and patient-reported outcomes of patients restored with non-precious metal alloy double crown-retained removable partial dentures (NP-D-RPDs). (2) Methods: Partially edentulous patients were restored with non-precious metal alloy partially veneered NP-D-RPDs. Survival rates, success rates, failures and patient-reported outcomes were investigated and statistically evaluated. (3) Results: A total of 61 patients (65.6 ± 10.8 years) were included and clinically and radiographically examined. The mean follow-up time was 25.2 ± 16.5 months. In total, 82 NP-D-RPDs and 268 abutment teeth were examined. The overall survival rate of the NP-D-RPDs was 100% after a mean follow-up time of 2.1 years. The overall success rate was 68.3%. The overall satisfaction with the NP-D-RPDs was 94.3%. (4) Conclusions: Non-precious metal alloy partially veneered NP-D-RPDs seem to be an efficient alternative to precious metal alloy RPDs with excellent patient-reported outcomes.

16.
Int J Prosthodont ; 34(4): 518­527, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33662059

RESUMO

Monolithic zirconia implant-supported restorations connected to titanium bases or titanium inserts are increasing in popularity due to their application in a full digital workflow. These prefabricated abutments are connected to the all-ceramic superstructure by adhesive cementation. Although limited clinical data on the outcomes of this type of restoration are available, a few laboratory studies have shown possible debonding issues. This case report presents a bonding failure of a fixed dental prosthesis supported by titanium bases after short clinical use. A treatment alternative is also proposed using the available digital dental technology.


Assuntos
Coroas , Titânio , Desenho Assistido por Computador , Dente Suporte , Cimentos Dentários , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Formicinas , Humanos , Ribonucleotídeos , Zircônio
17.
Quintessence Int ; 51(7): 566-576, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32500864

RESUMO

OBJECTIVES: Long-term retrospective evaluation of the survival rate and the technical and biologic outcomes of all-ceramic inlays and onlays in premolars and molars. METHOD AND MATERIALS: Fifty-four patients treated as part of a prospective clinical trial and having received 157 inlays and 27 onlays made out of a leucite-reinforced glass-ceramic (IPS Empress) in premolars and molars, were invited to the present follow-up examination. The survival of the restorations was evaluated. The biologic outcomes were assessed by measuring the pocket probing depth (PPD), the Plaque Index (PI), and the Sulcus Bleeding Index (SBI). The technical behavior was evaluated using modified US Public Health Service criteria (modUSPHS). Finally, patient satisfaction was recorded with a questionnaire. Data of patients and restored teeth were analyzed descriptively, and continuous variables were given in mean values and standard deviations. For the analysis of the restoration survival over time, the Kaplan-Meier survival estimate was calculated. The level of statistical significance was set at P < .05. RESULTS: Thirty-six patients (20 women, 16 men; mean age 50.9 years) with 132 restorations, 107 inlays and 25 onlays, were examined after a mean observation time of 11.2 ± 4.3 years. The overall 11-year survival rate of the 132 restorations was 80.3%. Inlays exhibited an 11-year survival rate of 80.4% and onlays of 80.0%. Twenty-two technical complications occurred. Ceramic fractures (10.6%) and chipping (2.3%) were the most frequent complications. Six biologic complications occurred (4.5%). CONCLUSION: Glass-ceramic inlays and onlays presented favorable long-term clinical survival and success rates. Technical complications were predominant, and biologic problems remained rare. More clinical long-term data are needed.


Assuntos
Porcelana Dentária , Restaurações Intracoronárias , Cerâmica , Falha de Restauração Dentária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos
18.
J Vis Exp ; (150)2019 08 13.
Artigo em Inglês | MEDLINE | ID: mdl-31475980

RESUMO

The basic principle of the rabbit calvarial model is to grow new bone tissue vertically on top of the cortical part of the skull. This model allows assessment of bone substitution materials for oral and craniofacial bone regeneration in terms of bone growth and neovascularization support. Once animals are anesthetized and ventilated (endotracheal intubation), four cylinders made of polyether ether ketone (PEEK) are screwed onto the skull, on both sides of the median and coronal sutures. Five intramedullary holes are drilled within the bone area delimited by each cylinder, allowing influx of bone marrow cells. The material samples are placed into the cylinders which are then closed. Finally, the surgical site is sutured, and animals are awaken. Bone growth may be assessed on live animals by using microtomography. Once animals are euthanized, bone growth and neovascularization may be evaluated by using microtomography, immune-histology and immunofluorescence. As the evaluation of a material requires maximum standardization and calibration, the calvarial model appears ideal. Access is very easy, calibration and standardization are facilitated by the use of defined cylinders and four samples may be assessed simultaneously. Furthermore, live tomography may be used and ultimately a large decrease in animals to be euthanized may be anticipated.


Assuntos
Desenvolvimento Ósseo/fisiologia , Regeneração Óssea/fisiologia , Substitutos Ósseos/administração & dosagem , Neovascularização Fisiológica/fisiologia , Crânio/fisiologia , Animais , Desenvolvimento Ósseo/efeitos dos fármacos , Regeneração Óssea/efeitos dos fármacos , Neovascularização Fisiológica/efeitos dos fármacos , Coelhos , Crânio/efeitos dos fármacos , Crânio/cirurgia , Titânio/administração & dosagem
20.
Eur J Oral Implantol ; 10 Suppl 1: 47-65, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28944368

RESUMO

AIM: The impact of prosthetic material selection on implant survival is not clear. The current criteria for choosing a prosthetic material seem to be based on clinician preferences. This systematic review aims to evaluate the impact of restorative materials on the mid- and long-term survival of implants supporting single crowns and fixed partial dentures. MATERIALS AND METHODS: Hand and MEDLINE searches were performed to identify relevant literature for single crowns (SC) and fixed partial dentures (FPD). Further inclusion criteria were a mean follow-up period of at least 3 years, the inclusion of at least 10 patients in a relevant study cohort, and a clear description of prosthesis type and prosthetic material. RESULTS: A total of 63 studies for the SC group and 11 studies for the FPD group were included. Full arch restorations were not included. The materials utilised in the SC group were metal-ceramic (precious and non-precious), lithium-disilicate, veneered zirconia, veneered alumina, and nanoceramics. The materials used in the FPD group were metal-ceramic (precious), veneered titanium, metal-resin (precious), and veneered zirconia. No significant impact on the prosthetic material relating to mid- or long-term implant survival was identified. Furthermore, there were no statistically significant differences between the survival rates of the dental prostheses made from different materials (SC and FPD group). Single crowns made of nanoceramics showed a higher risk for decementation relative to other materials (0.80, 95% CI [0.67; 0.89]; P < 0.0001), whereas metal-resin FPDs showed a higher risk for chipping (0.36, 95% CI [0.23; 0.52]; P = 0.0072). CONCLUSION: The current evidence suggests that prosthetic material selection has no influence on mid- and long-term survival of implants restored with single crowns and fixed partial dentures. Similarly, the prosthetic material seems to have no significant impact on prosthetic survival rates. Further research is required to provide more evidence regarding the impact of the prosthetic material on long-term outcome. Conflict-of-interest statement: The authors declare that they have no conflict of interest.


Assuntos
Coroas , Materiais Dentários , Prótese Parcial Fixa , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Planejamento de Dentadura , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA