Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 127
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Prosthodont ; 33(3): 212-220, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37653684

RESUMO

PURPOSE: This systematic review and meta-analysis aimed to evaluate the difference in the color stability of light-cured and dual-cured resin cements. MATERIALS AND METHODS: Two separate reviewers used the PubMed, Scopus, Web of Science, Embase, and Scielo databases to execute the systematic review. For the analysis, studies that evaluated the color stability of dual-cured and light-cured resin cements over time were used. The random effects model was used in the meta-analysis. Analyses of subgroups were carried out based on the aging technique. The methodological quality of each in vitro study was evaluated in accordance with the parameters of a prior systematic review. RESULTS: From all databases, a total of 2223 articles were retrieved. Following the screening of titles and abstracts, 44 studies were selected for full text review, and a total of 27 articles were used for the qualitative analysis. Finally, 23 articles remained for the qualitative analysis. The majority of studies were labeled as having a medium risk of bias. The global analysis showed that the dual-cure resin cements had considerably greater differences in the color change (p = 0.006). A high heterogeneity index (86%) was found in the analysis. CONCLUSIONS: The best available in vitro evidence suggests that dual-polymerizing cement has higher color variation than light-polymerized materials. To reduce the likelihood of color change after the luting of thin ceramic restorations, clinicians should employ light-polymerizable resin cements.


Assuntos
Cerâmica , Cimentos de Resina , Cor , Teste de Materiais , Projetos de Pesquisa
2.
Rev Cardiovasc Med ; 24(6): 159, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39077523

RESUMO

Background: The link between dental, infective and obstructive cardiovascular diseases is debatable. Aim: To systematically review the literature to assess the association between dental conditions and development of cardiovascular disease. Methods: The systematic review was conducted following the PRISMA guidelines using PubMed (Medline), Web of Science, Scopus, EMBASE and SciELO. Results: Out of 6680 records, 82 articles were eligible for inclusion after reviewing titles and abstracts. No association between dental disease and cardiovascular disease has been observed in 10 studies while a potential link has been suggested by the remaining trials. Tooth loss and periodontitis are the main evaluated oral conditions while coronary artery disease, stroke, atherosclerosis and myocardial infarction represent the major cardiovascular events. The interaction between these two clinical entities is based on direct mechanism mediated by systemic inflammatory response, leakage of cytokines and endothelial cells invasion by oral pathogens and indirect mechanism mediated by common risk factors or confounders. Conclusions: It seems that tooth loss, periodontitis and poor oral hygiene increase the risk of atherosclerotic cardiovascular events, and subsequently oral health care professionals could contribute to public health cardiovascular control efforts.

3.
Biofouling ; 39(1): 110-120, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36946247

RESUMO

This study aimed to evaluate the antimicrobial activity and physicochemical properties of a novel dual-cure endodontic sealer containing copaiba oil. The copaiba oil was obtained and characterized by gas chromatography (GC), and the minimum inhibitory concentration (MIC) was performed. The experimental sealers were formulated with copaiba oil concentrations of 0, 0.5, 1, and 2%, and the RealSeal™ (Sybron endo, Orange, USA) and AH Plus (Dentsply De Trey Gmbh, Konstanz, Germany) were used as the commercial references. The antimicrobial activity of the sealers was evaluated by the direct contact test for 1h and 24h. To evaluate the physicochemical properties of the sealers, the degree of conversion, setting time, film thickness, dimensional stability, and radiopacity tests were performed. The data were statistically analyzed by one-way ANOVA and Tukey's test (α = 0.05). Concerning the results, the sealers containing copaiba oil showed antimicrobial activity without harming the physicochemical properties.


Assuntos
Óleos Voláteis , Materiais Restauradores do Canal Radicular , Materiais Restauradores do Canal Radicular/farmacologia , Materiais Restauradores do Canal Radicular/química , Enterococcus faecalis , Teste de Materiais , Biofilmes , Antibacterianos/farmacologia , Óleos Voláteis/farmacologia
4.
Clin Oral Investig ; 27(7): 3447-3456, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36947264

RESUMO

OBJECTIVES: To evaluate the incorporation of halloysite nanotubes (HNTs) loaded with one of two calcium sources (i.e., calcium hydroxide/CaOH2 or beta-tricalcium phosphate/ß-TCP) on the physicochemical and biological properties of an experimental resin-based dual-cured endodontic sealer. MATERIALS AND METHODS: HNTs were encapsulated with CaOH2 or ß-TCP at 10 wt.%. HNTs containing CaOH2 or ß-TCP were added into the experimental sealers at 50 wt.%. The control sealers were the calcium-free HNT-modified resin-based experimental sealer and AH Plus™, a commercially available endodontic sealer. Degree of conversion, setting time, flow, film thickness, radiopacity, dimensional stability, and calcium ions release were determined. Antibiofilm properties and cytocompatibility of the formulated sealers and commercial control were also evaluated. One and two-way ANOVA analysis followed by Tukey's post hoc test was conducted to evaluate the effect of the independent variable on the evaluated properties. RESULTS: FTIR confirmed the encapsulation of calcium sources into HNTs. Regarding flow and film thickness, the values obtained from these sealers were in accordance with the specifications provided by ISO 6876. For radiopacity, AH Plus™ achieved the highest radiopacity (p<0.05). Among the experimental formulations, all experimental HNT-containing compositions exhibited values below 3 mm Al. The experimental sealers showed greater dimensional changes when compared to the commercial (AH Plus™) control. The release of calcium ions was observed for the HNT_CaOH2 and HNT_ß-TCP sealers without statistical differences. Experimental sealers containing HNT_CaOH2 and HNT_ß-TCP significantly reduced the CFU/mL count and showed cell compatibility. CONCLUSIONS: The findings of this study demonstrate that the incorporation of HNT_CaOH2 or HNT_ß-TCP into resin-based experimental sealers promoted antimicrobial effects and gradual calcium release without impairing cytocompatibility or physicochemical properties of the sealers. Still, an adjustment to reach the minimal radiopacity established by ISO 6876 is needed. CLINICAL RELEVANCE: The experimental resin-based sealers seemed to be an alternative for endodontics. The incorporation of calcium sources exerts promising antimicrobial effects while displaying low cell toxicity.


Assuntos
Hidróxido de Cálcio , Selantes de Fossas e Fissuras , Resinas Sintéticas , Materiais Restauradores do Canal Radicular , Humanos , Materiais Restauradores do Canal Radicular/farmacologia , Hidróxido de Cálcio/farmacologia , Cálcio , Anti-Infecciosos , Teste de Materiais
5.
J Esthet Restor Dent ; 35(3): 493-500, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36260931

RESUMO

OBJECTIVE: Problems in the confection of indirect restorations may increase the marginal and internal gap. This study aimed to quantify the marginal and the internal fit of overlays fabricated with three different materials. MATERIALS AND METHODS: Standardized cavities were prepared on endodontically treated human third molars and digital impressions were done using an intraoral camera (Trios 3). Restorations were designed (n = 15) and fabricated with three materials: Hybrid ceramic (Cerasmart; GC Corp, EUROPE), high-strength lithium disilicate (GC Initial® LiSi Press; GC Corp, Tokyo, Japan), and zirconia reinforced Lithium Silicate Glass Ceramic (Vita Suprinity; Vita, Germany). Axial, marginal, pulpal, and gingival gaps were calculated by measuring the distance between the restoration and the tooth at several reference points. Two-Way analysis of variance was used for statistical analysis. The significance level was set at α = 0.05. RESULTS: Mean gap was significantly influenced by the material (p < 0.001), gap localization (p < 0.001), and interaction between the factors (p = 0.002). For all materials, the highest gap was observed at gingival and pulpal surfaces (p ≤ 0.015). LiSi Press achieved the overall lowest values at axial values measurements (p ≤ 0.003). CONCLUSIONS: The performance of a CAD/CAM system relative to marginal adaptation is influenced by the restorative material used. High-strength lithium disilicate seems to be showed the best marginal adaptation. CLINICAL SIGNIFICANCE: Marginal and internal adaptation of CAD/CAM restorations could be influenced by the type of material chosen.


Assuntos
Coroas , Planejamento de Prótese Dentária , Humanos , Adaptação Marginal Dentária , Materiais Dentários , Desenho Assistido por Computador
6.
J Esthet Restor Dent ; 35(8): 1218-1238, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37395344

RESUMO

INTRODUCTION: In a suitable condition, it is important to perform any dental restorative procedure using an operatory field isolated. Then, the aim of this study was to compare the bond strength of composite restorations to dentin affected by any contamination agent through a systematic review. METHODS: This systematic review was performed following the PRISMA 2020 guidelines. The literature search was conducted until September 2022 by scanning the following databases: Embase, PubMed, Scielo, Scopus, and Web of Science. Manuscripts evaluated the bond strength of resin-based materials to permanent human dentin contaminated with blood or saliva were selected for full-text review. The risk of bias was assessed by the RoBDEMAT tool. RESULTS: A total of 3750 papers resulted from the search from all databases. After the full-text reading, a total of 62 articles remained for the qualitative analysis. The contamination agents used were blood, saliva, and hemostatic agents. A great variety of protocols were used to contaminate the dentin surface, and the contamination process occurred in several steps of the bonding process, including before and after the etching process, after the primer application and after the adhesive application. Also, several decontamination procedures were tested, including reapplication of the etching material, rinsing with water, chlorhexidine or sodium hypochlorite and reapplication of the adhesive system. CONCLUSION: Any contamination with blood or saliva impaired the bond strength of resin-based materials to dentin. Decontamination procedures including water-spray and reapplication of the bonding system could revert the impairment produced by the saliva or blood contamination. The use of hemostatic agents as a method of blood decontamination is not recommended. CLINICAL SIGNIFICANCE: Clinicians should avoid contamination during a bonding procedure, otherwise, a reduction in the bond quality is expected.


Assuntos
Colagem Dentária , Hemostáticos , Humanos , Cimentos Dentários/química , Adesivos Dentinários/química , Cimentos de Resina/química , Resinas Compostas/química , Colagem Dentária/métodos , Propriedades de Superfície , Descontaminação , Hemostáticos/química , Dentina , Água/química , Teste de Materiais
7.
Biofouling ; 38(3): 250-259, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35332825

RESUMO

This study sought to evaluate the physical and antimicrobial properties of a thermopolymerizable acrylic resin (PMMA) modified with metallic methacrylate monomers -zirconia (ZM), tin (TM), and di-n-butyl (DNTMB) methacrylates. Color stability was evaluated before and after immersion of samples in a staining solution by a digital spectrophotometer. The mechanical brushing test was evaluated by the roughness test. The flexural strength test used a mechanical testing machine. Human keratinocytes were used to assess cell viability and the biofilm formation assay was carried out for 5 days, in a microcosms model after one year of specimen storage. For statistical analysis, the method chosen was based on adherence to the normal distribution model and equality of variances (p < 0.05). The addition of DNTMB to PMMA promoted great antimicrobial action, acceptable cytocompatibility, without hampering the physical-mechanical properties of the commercial material. Therefore, the modified PMMA proved to be a promisor alternative to conventional resins.This study sought to evaluate the physical and antimicrobial properties of a thermopolymerizable acrylic resin (PMMA) modified with metallic methacrylate monomers -zirconia (ZM), tin (TM), and di-n-butyldimethacrylate-tin (DNTMB) methacrylates. Color stability was evaluated before and after immersion of samples in a staining solution using a digital spectrophotometer. The mechanical brushing test was evaluated by the roughness test. The flexural strength test used a mechanical testing machine. Human keratinocytes were used to assess cell viability and the biofilm formation assay was carried out for 5 days in a microcosm model after one year of specimen storage. For statistical analysis, the method chosen was based on adherence to the normal distribution model and equality of variances (p < 0.05). The addition of DNTMB to PMMA promoted great antimicrobial action, acceptable cytocompatibility, without hampering the physical-mechanical properties of the commercial material. Therefore, the modified PMMA proved to be a promising alternative to conventional denture base resins for dental use.


Assuntos
Anti-Infecciosos , Polimetil Metacrilato , Resinas Acrílicas/farmacologia , Biofilmes , Humanos , Teste de Materiais , Metacrilatos/farmacologia , Propriedades de Superfície , Estanho
8.
BMC Health Serv Res ; 22(1): 393, 2022 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-35337336

RESUMO

BACKGROUND: The COVID-19 pandemic has significantly influenced the routine of healthcare workers. This study investigated the impact of the pandemic on dental practice and dentists' feelings in Latin America. METHODS: A survey was conducted with dentists from 11 Spanish-speaking Latin American countries in September-December 2020. Professionals were invited by email and via an open campaign promoted on social media. The questions investigated dental care routines, practice changes, and feelings about the pandemic. Descriptive statistics were used to identify frequencies and distributions of variables. Proportions were compared using chi-square tests. RESULTS: A total of 2127 responses were collected from a sample with diverse demographic, sex, work, and education characteristics. The impact of COVID-19 was considered high/very high by 60% of respondents. The volume of patients assisted weekly was lower compared with the pre-pandemic period (mean reduction = 14 ± 15 patients). A high rate of fear to contracting the COVID-19 at work was observed (85%); 4.9% of participants had a positive COVID-19 test. The main professional challenges faced by respondents were reduction in the number of patients or financial gain (35%), fear of contracting COVID-19 (34%), and burden with or difficulty in purchasing new personal protective equipment (22%). The fear to contracting COVID-19 was influenced by the number of weekly appointments. A positive test by the dentists was associated with their reports of having assisted COVID-19 patients. The most cited feelings about the pandemic were uncertainty, fear, worry, anxiety, and stress. Negative feelings were more prevalent for professionals who did not receive training for COVID-19 preventive measures and those reporting higher levels of fear to contract the disease. CONCLUSION: This multi-country survey indicated a high impact of the pandemic on dental care routines in Latin America. A massive prevalence of bad feelings was associated with the pandemic.


Assuntos
COVID-19 , COVID-19/epidemiologia , Odontólogos , Emoções , Humanos , América Latina/epidemiologia , Pandemias , Inquéritos e Questionários
9.
Clin Oral Investig ; 26(6): 4327-4335, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35142924

RESUMO

OBJECTIVES: To evaluate and to compare the clinical performance and survival rate of posterior monolithic and veneered zirconia fixed partial dentures (FPDs). MATERIAL AND METHODS: Sixty 3-unit posterior FPDs were included in the study. The patients were randomly distributed into two groups (n = 30 each) to receive either a monolithic (Zenostar T, Wieland Dental) or veneered zirconia (IPS e.max ZirCAD, Ivoclar Vivadent) FPD. Each patient received only 1 FPD. Tooth preparations were scanned (Trios 3, 3Shape), designed (Dental System 2016, 3 Shape), milled (Zenotec CAM 3.2, Wieland Dental), and cemented with a resin cement. Technical and biological outcomes and periodontal parameters were assessed. Data analysis was made using the Friedman and the Wilcoxon signed-rank tests with the Bonferroni correction and the Mann-Whitney U test. RESULTS: The survival rate at 3 years was 100% for veneered and 90% for monolithic zirconia restorations. Three monolithic zirconia FPDs were lost because of biologic complications. The main complication in the veneered zirconia FPDs was the fracture of the veneering ceramic in 4 of the veneered zirconia FPDs. No fracture of the frameworks was observed in any of the groups. All restorations were assessed as satisfactory after 3 years. No differences in periodontal parameters were observed between the groups. CONCLUSIONS: The results of this study suggest that monolithic zirconia and complete digital flow could be a viable alternative to veneered zirconia in the posterior regions. CLINICAL RELEVANCE: The monolithic zirconia restorations with a digital workflow can be a viable alternative in posterior fixed partial dentures, with good periodontal outcomes. CLINICAL TRIAL REGISTRATION NUMBER: ClinicalTrials.gov (Identifier NCT 04,879,498).


Assuntos
Porcelana Dentária , Falha de Restauração Dentária , Desenho Assistido por Computador , Facetas Dentárias , Prótese Parcial Fixa , Seguimentos , Humanos , Zircônio
10.
J Prosthet Dent ; 128(5): 876-885, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33838916

RESUMO

STATEMENT OF PROBLEM: Although the clinical use of self-adhesive flowable composite resins is convenient, the decision to use flowable or conventional composite resin remains controversial. PURPOSE: The purpose of this systematic review and meta-analysis was to assess the in vitro bond strength of self-adhesive flowable composite resins to enamel or dentin compared with conventional composite resins using etch-and-rinse or self-etch adhesive systems. MATERIAL AND METHODS: Two independent reviewers performed searches in the PubMed (MEDLINE), Cochrane Wiley, Web of Science, Scopus, and Google Scholar databases for studies reporting on the bond strength of self-adhesive flowable and conventional composite resins to enamel and dentin published from January 2010 up to September 2020. A meta-analysis software program was used for the meta-analysis. Comparisons were conducted using standardized mean differences considering the random-effects model (α=.05). RESULTS: Twenty-two studies were considered for the meta-analysis. Immediate and long-term bond strength to enamel was improved when a conventional composite resin was used in combination with an adhesive system (P<.001). Bond strength to dentin was improved by using an adhesive system in combination with a conventional composite resin (P<.001). CONCLUSIONS: The bond strength of self-adhesive flowable composite resins is lower than that of conventional composite resins, indicating limited ability to bond to enamel and dentin.


Assuntos
Colagem Dentária , Cimentos de Resina , Cimentos de Resina/química , Dentina/química , Cimentos Dentários , Teste de Materiais , Propriedades de Superfície , Resinas Compostas/uso terapêutico , Resinas Compostas/química , Adesivos Dentinários/química
11.
J Oral Implantol ; 48(2): 125-132, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33710306

RESUMO

The aim of this clinical report is to describe a maxillary full-arch implant supported restoration with immediate loading performed by means of an entirely digital work flow with photogrammetric system and intraoral scanning. A female patient with an edentulous maxillary arch attended the dental clinic seeking a maxillary fixed restoration. After treatment planning, 6 implants were placed using a surgical splint fabricated digitally by intraoral scanning of her previous removable prosthesis. Multiunit abutments were fitted, and 2 digital impressions were taken, one with a photogrammetric system for determining implant positions and the other with an intraoral scanner for soft tissue registration. The acrylic resin structure of the immediate prosthesis was milled and placed within 8 hours of implant surgery. This provisional structure fitted correctly and provided adequate esthetics and function. Radiographic and clinical follow-up after 24 months observed adequate implant evolution.


Assuntos
Implantes Dentários , Carga Imediata em Implante Dentário , Boca Edêntula , Técnica de Moldagem Odontológica , Prótese Dentária Fixada por Implante , Estética Dentária , Feminino , Humanos
12.
J Prosthodont ; 31(7): 606-613, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34860426

RESUMO

PURPOSE: To compare the load to fracture of cobalt-chromium (Co-Cr) 3-unit posterior fixed partial denture (FPD) frameworks manufactured by conventional and digital techniques and to evaluate the influence of the framework design on the fracture load. MATERIAL AND METHODS: Eighty 3-unit Co-Cr posterior FPD frameworks were fabricated with two designs: intermediate pontic (n = 40) and cantilever (n = 40). Each design was randomly divided into four groups (n = 10): casting, direct metal laser sintering, soft metal milling, and hard metal milling. After thermal cycling, all specimens were subjected to a 3-point bending test until fracture. Data were statistically analyzed using one-way ANOVA, Welch and Brown-Forsythe test, Ryan-Einot-Gabriel-Welsch F and Tamhane T2 post hoc test, Student's t test, and Weibull statistics (α = 0.05). RESULTS: Significant differences (p < 0.001; F = 39.59) were found among intermediate pontic frameworks (except between laser sintering and hard metal milling), and cantilevered frameworks (F = 36.75) (except between laser sintering and hard metal milling, and casting and soft metal milling). The cantilever groups showed load to fracture values significantly lower than those of the intermediate pontic (p < 0.001; F = 28.29). The Weibull statistics corroborated the results. CONCLUSIONS: Hard metal milling and laser sintered frameworks exhibited the highest load to fracture values. However, all tested frameworks demonstrated clinically acceptable load to fracture values. The framework design directly affected the fracture load, with drastically lower values in cantilevered frameworks.


Assuntos
Cromo , Tecnologia Digital , Cobalto , Desenho Assistido por Computador , Prótese Parcial Fixa , Humanos , Teste de Materiais
13.
J Evid Based Dent Pract ; 22(4): 101776, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36494107

RESUMO

OBJECTIVES: To determine the clinical performance of light-cured calcium silicate-based cement for direct or indirect pulp capping. The research question was as follows: in teeth with deep caries lesions, does the use of resin-modified calcium silicate-containing composites improve the radiological success and prevent irreversible pulpitis and pulpal necrosis compared with other pulp-capping agents? MATERIALS AND METHODS: The following databases were screened until September 2021: PubMed, Web of Science, Scielo, Scopus, Embase, and The Cochrane Library. Randomized clinical trials reporting the clinical evaluation of a resin-modified calcium silicate material as an agent for pulp therapy were included. Meta-analysis was performed using the Rev Manager v5.4.1 software. The risk difference and 95% confidence interval of the dichotomous outcome (restoration failure or success) were calculated for comparison. RESULTS: Ten studies were considered for qualitative analysis and meta-analysis. Studies evaluating the performance of light-cured calcium silicate-based cement from 1 month to a maximum follow-up period of 36 months and comparing it with the performance of CaOH, mineral trioxide aggregate, or Biodentine were included. In the global analysis for direct pulp capping at 6-month follow-up, no statistical differences were observed between the experimental group using the light-cured calcium silicate-based cement and control group (P = .28). However, at 12-month follow-up, global analysis favored the control group (P < .001). For indirect pulp capping, at 6- and 24-month follow-ups, no statistically significant differences were observed between the experimental and control groups (P = .88; P = .21). CONCLUSIONS: Light-cured calcium silicate-based cement showed a limited clinical performance as a direct pulp capping agent, especially when evaluated in the long term. However, using it as an indirect pulp capping agent may be a reliable and easy-to-use option for restoring teeth with deep caries. CLINICAL SIGNIFICANCE: This systematic review provides evidence that supports the use of light-cured calcium silicate-based cement as an indirect pulp capping agent.


Assuntos
Agentes de Capeamento da Polpa Dentária e Pulpectomia , Humanos , Agentes de Capeamento da Polpa Dentária e Pulpectomia/uso terapêutico , Capeamento da Polpa Dentária , Cimento de Silicato , Cimentos de Ionômeros de Vidro , Cimentos Dentários/uso terapêutico , Resinas Compostas
14.
Odontology ; 109(4): 904-911, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34114136

RESUMO

The objective was to evaluate the effect of the incorporation of calcium hydroxyapatite particles (HAp) in the diametral tensile strength of a conventional type II glass ionomer (GC Gold Label 2) and a resin-modified glass ionomer cement (GC Gold Label 2 LC R). Two experimental HAp (E1HAp or E2HAp) were synthesized and characterized using X-ray diffraction and Confocal Raman spectroscopy. Both HAp were added into the powder of a conventional or resin-modified glass ionomer cement at 5 or 10 wt.%. A commercial HAp (CHAp) was used as reference material. For each glass ionomer cement, a group without the incorporation of HAp was used as a control. A universal testing machine was used for the mechanical test. The results were analyzed through a two-way ANOVA test followed by a complementary Tukey test. For all analyzes, the level of significance was set at α = 0.05. The average particle size for E1Hap was 15 µm, E2HAp was 35 µm and for CHAp was 1 µm. For conventional GIC, the addition of 10% E1HAp and 5% CHAp significantly increased the diametral tensile strength values (p ≤ 0.005). On the other hand, for the resin-modified GIC, except for the 5% E2HAp group, all experimental groups significantly reduced the values of diametral tensile strength (p ≤ 0.007). The addition of HAp improved the mechanical properties only for the conventional glass ionomer cement.


Assuntos
Durapatita , Cimentos de Ionômeros de Vidro , Teste de Materiais , Resistência à Tração
15.
J Esthet Restor Dent ; 33(5): 702-712, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33973710

RESUMO

OBJECTIVE: To evaluate whether natural antioxidant treatment would enhance the immediate bond strength of dental adhesives to bleached enamel through a systematic review and meta-analysis. MATERIALS AND METHODS: Two reviewers performed a literature search up to November 2019 in seven databases. Only in vitro studies that evaluated the effect of the application of natural antioxidants in the bond strength of dental adhesives to bleached enamel were included. Analyses were carried out using RevMan 5.3.5 (The Nordic Cochrane Centre, The Cochrane Collaboration, Copenhagen, Denmark). A global analysis was performed with random-effects models at a significance level of p < 0.05. RESULTS: Twenty-four studies were included in the meta-analysis. Both in-office (p Ë‚ 0.001) and at-home (p Ë‚ 0.001) bleaching reduced the immediate bond strength. When compared to bleached enamel, all antioxidants improved the bond strength, but only grape seed extract/proanthocyanidin and lycopene restored it to the control values (p Ëƒ 0.05). CONCLUSION: In vitro available evidence suggests that the use of natural antioxidants can be beneficial when performing immediate resin-based restorations after bleaching, however, these results should be taken with caution since they are based on medium and high risk of bias studies; low bias studies are needed to draw relevant conclusions. CLINICAL SIGNIFICANCE: Despite the lack of clinical evidence, the present study confirms the benefits of applying natural antioxidant agents to enhance the in vitro bond strength when performing immediate esthetic restorations after bleaching. Since certain antioxidant agents proved more effective than others, clinical investigations may be focused on the ones that withhold the most promising results. The application of natural antioxidants after bleaching may enable immediate esthetic restorations to be performed.


Assuntos
Colagem Dentária , Clareamento Dental , Antioxidantes , Ácido Ascórbico , Resinas Compostas , Esmalte Dentário , Resistência ao Cisalhamento
16.
J Esthet Restor Dent ; 33(6): 849-855, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33615676

RESUMO

OBJECTIVE: To evaluate the whiteness index (WID ) and surface roughness (Ra) of bovine enamel after simulated tooth brushing with different commercial and experimental whitening dentifrices. MATERIALS AND METHODS: Cylindrical enamel bovine specimens were acid etched, stained, and divided in nine groups (n = 8): Colgate® Optic White®, Crest® Baking Soda and Peroxide, Arm and Hammer® Advanced White™ Extreme Whitening, Rembrandt® Deeply White® + Peroxide, Close up® White Attraction Natural Glow, Hinode Prowhite, and experimental dentifrice containing papain (PP), bromelain (PB), or papain and bromelain (PPB). Ra and WID were obtained initially and after 600, 1200, and 3,600 cycles of simulated tooth brushing. Data were analyzed using two-way analysis of variance test (α = 0.05). RESULTS: Ra was significantly influenced by both dentifrice (p = 0.043) and period of tooth-brushing simulation (p < 0.001). Except for PP and PPB, all groups showed a statistically significant increase in Ra after simulated tooth brushing. After staining and brushing, none of the materials tested increased the initial WID . CONCLUSIONS: The effect of commercial whitening dentifrices may be related to their high abrasiveness. Experimental formulations tested provided a similar effect without undesired wear of enamel. Whitening dentifrices only act through an abrasive effect rather than bleaching the tooth structures. When used, special care must be taken for avoid undesired wear of enamel. Experimental dentifrices provided similar removal of extrinsic stains without undesired abrasiveness; however, this effect may be due to the use of less aggressive abrasives in their formulations.


Assuntos
Dentifrícios , Clareamento Dental , Animais , Bovinos , Esmalte Dentário , Peptídeo Hidrolases , Peróxidos , Escovação Dentária
17.
J Prosthet Dent ; 125(2): 323.e1-323.e7, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33176924

RESUMO

STATEMENT OF PROBLEM: Marginal fit of zirconia restorations is an important criterion for their long-term success. However, in spite of the wide use of zirconia in dentistry, the relationship between marginal fit and low-temperature degradation from aging is unclear. PURPOSE: The purpose of this in vitro study was to compare the marginal adaptation of veneered and monolithic zirconia and metal-ceramic computer-aided design and computer-aided manufacturing (CAD-CAM) crowns before and after cementation and to evaluate the influence of artificial aging on the adaptation of zirconia crowns. MATERIAL AND METHODS: Seventy-two standardized dies were prepared to receive a posterior crown and randomly divided into 6 groups (n=12) as per the material and the presence or not of cement: metal-ceramic, veneered zirconia, and monolithic zirconia. The zirconia groups were subjected to accelerated low-temperature degradation through hydrothermal aging in an autoclave at 131 °C and 0.17 MPa for 5 and 20 hours. A scanning electron microscope with a magnification of ×1000 was used for marginal adaptation measurements, and X-ray diffraction (XRD) was used to characterize phase transformation degradation. The data were statistically analyzed using 2-way ANOVA, repeated measures ANOVA with Greenhouse-Geisser correction, and the t test (α=.05). RESULTS: No significant differences in the marginal discrepancy were recorded among the analyzed groups. The presence of cement did not influence marginal fit in any treatment group. No significant differences were observed in the marginal adaptation values before and after aging (P>.05). After 20 hours of aging, the monoclinic phase increase to 8.3% on veneered zirconia and to 3.1% on monolithic crowns. CONCLUSIONS: Monolithic and bilayer CAD-CAM zirconia crowns showed marginal gaps that were within an acceptable range of clinical discrepancy, regardless of cementation. Marginal adaptation was not influenced by aging. Low-temperature degradation did not lead to a significant transformation from the tetragonal to monoclinic phase.


Assuntos
Cimentação , Adaptação Marginal Dentária , Cerâmica , Desenho Assistido por Computador , Coroas , Porcelana Dentária , Planejamento de Prótese Dentária , Zircônio
18.
J Prosthet Dent ; 125(4): 706.e1-706.e6, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33581867

RESUMO

STATEMENT OF PROBLEM: The high recurrence rates of denture stomatitis may be associated with the resistance of biofilms to therapeutics. Therefore, methods that provide biomaterials with antifungal properties are an attractive solution to improving microbial control. PURPOSE: The purpose of this in vitro study was to modify conventional polymethyl methacrylate (PMMA) through the incorporation of metal methacrylate monomers and to evaluate the physicomechanical and optical properties and antifungal activity of the modified materials. MATERIAL AND METHODS: Experimental denture base acrylic resins were fabricated through the addition of zirconium methacrylate (ZM), tin methacrylate (TM), and di-n-butyldimethacrylate-tin (DNBMT) to the liquid of a commercially available denture base PMMA resin. Unmodified PMMA resin was used as the control. The degree of conversion of the materials was tested through Fourier transform infrared spectroscopy (n=3). A digital spectrophotometer was used to assess the color change of the modified materials (n=8). Differences in Knoop hardness and roughness between experimental groups were also evaluated (n=8). A biofilm accumulation test with Candida albicans (ATCC 62342) (n=4) was performed for 5 days in Sabouraud broth culture supplemented with 10% sucrose. Data were subjected to analysis of variance and the post hoc Tukey honestly significant difference test (α=.05). RESULTS: The degree of conversion and color-change values of the experimental materials were statistically similar to those of the control (P=.593). The incorporation of DNBMT significantly increased the hardness of the modified material (P=.014). The ZM, TM, and DNBMT groups had higher antifungal activity against C. albicans (P=.001) and lower roughness than the control group (control 0.65 ±0.05 µm; ZM 0.34 ±0.09 µm, TM 0.34 ±0.11 µm, and DNBMT 0.41 ±0.08 µm). CONCLUSIONS: The metal-containing methacrylate monomers provided antifungal action to the modified materials without affecting the physicomechanical or optical properties of the denture base resin. ZM, TM, and DNBMT are potential reactive agents for the fabrication of PMMA denture base resins with antifungal properties.


Assuntos
Bases de Dentadura , Polimetil Metacrilato , Resinas Acrílicas , Antifúngicos , Candida albicans , Teste de Materiais , Metacrilatos , Propriedades de Superfície
19.
J Prosthodont ; 30(4): 298-304, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32881181

RESUMO

PURPOSE: To evaluate the clinical performance and survival rate of posterior monolithic zirconia fixed partial dentures over a 2-year period. MATERIAL AND METHODS: A total of 20 patients, requiring 20 posterior fixed partial dentures were included in the study. Tooth preparations were scanned, and restorations were milled and cemented with a resin cement. The restorations were assessed for the quality of the surface and the color, anatomical form and marginal integrity. Periodontal status was assessed by determining the plaque index, gingival index, pocket depth, and margin index of the abutment teeth. Data were statistically analyzed using the Friedman and the Wilcoxon signed-rank tests with the Bonferroni correction. RESULTS: The survival rate at 2 years was 100%, and no biological or technical complications were observed. All restorations were assessed as satisfactory. The results obtained for gingival index and plaque index were better at 2 years follow-up, than at baseline. The margin index remained stable throughout the follow-up period. No differences in periodontal parameters were observed between abutment and control teeth. CONCLUSIONS: The high survival rate after 2 years suggest that monolithic zirconia may be an acceptable alternative to metal-ceramic and veneered zirconia restorations in the posterior region. Additional long-term, controlled studies are necessary to confirm the results.


Assuntos
Porcelana Dentária , Falha de Restauração Dentária , Prótese Parcial Fixa , Seguimentos , Humanos , Estudos Prospectivos , Fluxo de Trabalho , Zircônio
20.
Eur J Oral Sci ; 128(5): 436-443, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32741041

RESUMO

In this study, the cytotoxicity of different combinations of contemporary resin-based restoratives (adhesives, composites, luting agents) against human keratinocytes (HaCaT) was evaluated under two conditions, whether materials were applied to dentin or not. Adhesives (3-step etch-and-rinse/3ER: OptiBond FL; 2-step self-etch/2SE Clearfil SE Bond; Single Bond Universal/UNI), composites (conventional composite resin/CCR: Filtek Z350XT; flowable/FCR: Filtek Z350XT Flow; self-adhesive composite resin/SACR: Dyad Flow), and luting agents (conventional luting agent/CLA: Variolink-II; self-adhesive luting agent/SLA: RelyXU200) were combined according to their clinical use. Eluates from polymerized specimens applied to dentin were placed in contact with cells grown for 1 and 7 d. The controls were defined by cells without material contact. Cell viability was determined using MTT [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide)] assay. C=C conversion was investigated using Fourier-transform infrared spectroscopy. After 1 d of incubation, when dentin was not present, 2SE yielded the highest cell viability, whereas 3ER, UNI, and SACR showed higher cell viability in the presence of dentin. After 7 d, when dentin was absent, 2SE and CLA achieved significantly higher cell viability. The presence of dentin resulted in a drastically higher cell viability for all materials, except 2SE and CLA. UNI had the lowest C=C conversion. The presence of dentin was a significant factor, which resulted in higher cell viability than what was seen for the material specimens per se. All materials resulted in a lower viability of HaCaT than what was seen under the no-material control conditions, with effects mainly limited to the first 24 h.


Assuntos
Colagem Dentária , Adesivos Dentinários , Condicionamento Ácido do Dente , Resinas Compostas/toxicidade , Cimentos Dentários , Análise do Estresse Dentário , Dentina , Adesivos Dentinários/toxicidade , Humanos , Teste de Materiais , Cimentos de Resina/toxicidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA