Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Mech Behav Biomed Mater ; 146: 106097, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37678107

RESUMO

OBJECTIVE: Mandibular reconstruction using patient-specific cage implants is a promising alternative to the vascularized free flap reconstruction for nonirradiated patients with adequate soft tissues, or for patients whose clinical condition is not conducive to microsurgical reconstruction. This study aimed to assess the biomechanical performance of 3D printed patient-specific cage implants designed with a semi-automated workflow in a combined cadaveric and retrospective case series study. METHODS: We designed cage implants for two human cadaveric mandibles using our previously developed design workflow. The biomechanical performance of the implants was assessed with the finite element analysis (FEA) and quasi-static biomechanical testing. Digital image correlation (DIC) was used to measure the full-field strains and validate the FE models by comparing the distribution of maximum principal strains within the bone. The retrospective study of a case series involved three patients, each of whom was treated with a cage implant of similar design. The biomechanical performance of these implants was evaluated using the experimentally validated FEA under the scenarios of both mandibular union and nonunion. RESULTS: No implant or screw failure was observed prior to contralateral bone fracture during the quasi-static testing of both cadaveric mandibles. The FEA and DIC strain contour plots indicated a strong linear correlation (r = 0.92) and a low standard error (SE=29.32µÎµ), with computational models yielding higher strain values by a factor of 2.7. The overall stresses acting on the case series' implants stayed well below the yield strength of additively manufactured (AM) commercially pure titanium, when simulated under highly strenuous chewing conditions. Simulating a full union between the graft and remnant mandible yielded a substantial reduction (72.7±1.5%) in local peak stresses within the implants as compared to a non-bonded graft. CONCLUSIONS: This study shows the suitability of the developed semi-automated workflow in designing patient-specific cage implants with satisfactory mechanical functioning under demanding chewing conditions. The proposed workflow can aid clinical engineers in creating reconstruction systems and streamlining pre-surgical planning. Nevertheless, more research is still needed to evaluate the osteogenic potential of bone graft insertions.


Assuntos
Parafusos Ósseos , Mandíbula , Humanos , Estudos Retrospectivos , Fluxo de Trabalho , Mandíbula/cirurgia , Cadáver
2.
Acta Biomater ; 151: 628-646, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35940565

RESUMO

The treatment of femoral nonunion with large segmental bone defect is still challenging. Although magnesium alloys have been considered potential materials for such a treatment, their application is limited by their fast degradation. Adding bioceramic particles into magnesium to form Mg-matrix composites is a promising strategy to adjust their biodegradation rates and to improve their mechanical properties and cytocompatibility further. Here, we developed an extrusion-based additive manufacturing technique to fabricate biodegradable Mg-Zn/bioceramic composite scaffolds ex-situ. Inks carrying a Mg-Zn powder and 5, 10 and 15% ß-tricalcium phosphate (TCP) powder particles were investigated regarding the dispersion of ß-TCP particles in the inks and viscoelastic properties. Optimally formulated inks were then employed for subsequent 3D printing of porous composite scaffolds. The in vitro biodegradation rate of the scaffolds containing 5% ß-TCP decreased to 0.5 mm/y, which falls within the range desired for critical-sized bone substitution. As compared to the monolithic Mg-Zn scaffolds, the elastic moduli and yield strengths of the composite scaffolds were much enhanced, which remained in the range of the cancellous bone properties even after 28 d of in vitro degradation. The Mg-Zn/5TCP and Mg-Zn/10TCP scaffolds also exhibited improved biocompatibility when cultured with preosteoblasts, as compared to Mg-Zn scaffolds. In addition, the ALP activity and mineralization level of the composite scaffolds were much enhanced in the extracts of the composite scaffolds. Taken together, this research marks a great breakthrough in fabricating porous Mg-matrix composite scaffolds that meet several design criteria in terms of appropriate biodegradation rate, mechanical properties, and bioactivity. STATEMENT OF SIGNIFICANCE: The treatment of posttraumatic femoral nonunion with large segmental bone defect is still challenging. In this study, we developed a multi-material extrusion-based additive technique to fabricate porous Mg/bioceramic composite scaffolds for such a treatment. The technique allowed for the fine-tuning of printable inks to optimize the dispersion of micro-sized particles. The relative densities of the struts of the fabricated composite scaffolds reached 99%. The added bioceramic particles (ß-TCP) exhibited proper interfacial bonding with the Mg alloy matrix. The porous Mg-based composite possessed desired biodegradability, bone-mimicking mechanical properties throughout the in vitro biodegradation period and improved bioactivity to bone cells. These results demonstrated great prospects of extrusion-based 3D printed porous Mg materials to be developed further as ideal biodegradable bone-substituting materials.


Assuntos
Magnésio , Alicerces Teciduais , Ligas/farmacologia , Materiais Biocompatíveis , Fosfatos de Cálcio , Magnésio/farmacologia , Porosidade , Pós , Impressão Tridimensional , Zinco
3.
J Mech Behav Biomed Mater ; 132: 105291, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35660552

RESUMO

The reconstruction of large mandibular defects with optimal aesthetic and functional outcomes remains a major challenge for maxillofacial surgeons. The aim of this study was to design patient-specific mandibular reconstruction implants through a semi-automated digital workflow and to assess the effects of topology optimization on the biomechanical performance of the designed implants. By using the proposed workflow, a fully porous implant (LA-implant) and a topology-optimized implant (TO-implant) both made of Ti-6Al-4V ELI were designed and additively manufactured using selective laser melting. The mechanical performance of the implants was predicted by performing finite element analysis (FEA) and was experimentally assessed by conducting quasi-static and cyclic biomechanical tests. Digital image correlation (DIC) was used to validate the FE model by comparing the principal strains predicted by the FEM model with the measured distribution of the same type of strain. The numerical predictions were in good agreement with the DIC measurements and the predicted locations of specimen failure matched the actual ones. No statistically significant differences (p < 0.05) in the mean stiffness, mean ultimate load, or mean ultimate displacement were detected between the LA- and TO-implant groups. No implant failures were observed during quasi-static or cyclic testing under masticatory loads that were substantially higher (>1000 N) than the average maximum biting force of healthy individuals. Given its relatively lower weight (16.5%), higher porosity (17.4%), and much shorter design time (633.3%), the LA-implant is preferred for clinical application. This study clearly demonstrates the capability of the proposed workflow to develop patient-specific implants with high precision and superior mechanical performance, which will greatly facilitate cost- and time-effective pre-surgical planning and is expected to improve the surgical outcome.


Assuntos
Reconstrução Mandibular , Fenômenos Biomecânicos , Análise de Elementos Finitos , Humanos , Estresse Mecânico , Titânio , Fluxo de Trabalho
4.
J Mech Behav Biomed Mater ; 119: 104512, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33930652

RESUMO

Additive manufacturing (AM) offers great design freedom that enables objects with desired unique and complex geometry and topology to be readily and cost-effectively fabricated. The overall benefits of AM are well known, such as increased material and resource efficiency, enhanced design and production flexibility, the ability to create porous structures and on-demand manufacturing. When AM is applied to medical devices, these benefits are naturally assumed. However, hard clinical evidence collected from clinical trials and studies seems to be lacking and, as a result, systematic assessment is yet difficult. In the present work, we have reviewed 23 studies on the clinical use of AM patient-specific surgical guides (PSGs) for the mandible surgeries (n = 17) and temporomandibular joint (TMJ) patient-specific implants (PSIs) (n = 6) with respect to expected clinical outcomes. It is concluded that the data published on these AM medical devices are often lacking in comprehensive evaluation of clinical outcomes. A complete set of clinical data, including those on time management, costs, clinical outcomes, range of motion, accuracy of the placement with respect to the pre-operative planning, and extra complications, as well as manufacturing data are needed to demonstrate the real benefits gained from applying AM to these medical devices and to satisfy regulatory requirements.


Assuntos
Prótese Articular , Humanos , Porosidade , Articulação Temporomandibular/cirurgia
5.
Acta Biomater ; 114: 497-514, 2020 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-32771594

RESUMO

Biodegradable porous magnesium (Mg) scaffolds are promising for application in the regeneration of critical-sized bone defects. Although additive manufacturing (AM) carries the promise of offering unique opportunities to fabricate porous Mg scaffolds, current attempts to apply the AM approach to fabricating Mg scaffolds have encountered some crucial issues, such as those related to safety in operation and to the difficulties in composition control. In this paper, we present a room-temperature extrusion-based AM method for the fabrication of topologically ordered porous Mg scaffolds. It is composed of three steps, namely (i) preparing a Mg powder loaded ink with desired rheological properties, (ii) solvent-cast 3D printing (SC-3DP) of the ink to form scaffolds with 0 °/ 90 °/ 0 ° layers, and (iii) debinding and sintering to remove the binder in the ink and then get Mg powder particles bonded by applying a liquid-phase sintering strategy. A rheological analysis of the prepared inks with 54, 58 and 62  vol% Mg powder loading was performed to reveal their viscoelastic properties. Thermal-gravimetric analysis (TGA), Fourier transform infrared spectroscopy (FTIR), carbon/sulfur analysis and scanning electron microscopy (SEM) indicated the possibilities of debinding and sintering at one single step for fabricating pure Mg scaffolds with high fidelity and densification. The resulting scaffolds with high porosity contained hierarchical and interconnected pores. This study, for the first time, demonstrated that the SC-3DP technique presents unprecedented possibilities to fabricate Mg-based porous scaffolds that have the potential to be used as a bone-substituting material. STATEMENT OF SIGNIFICANCE: Biodegradable porous magnesium scaffolds are promising for application in the regeneration of critical-sized bone defects. Although additive manufacturing (AM) carries the promise of offering unique opportunities to fabricate porous magnesium scaffolds, current attempts to apply the AM approach to fabricating magnesium scaffolds still have some crucial limitations. This study demonstrated that the solvent-cast 3D printing technique presents unprecedented possibilities to fabricate Mg-based porous scaffolds. The judicious chosen of formulated binder system allowed for the negligible binder residue after debinding and the short-time liquid-phase sintering strategy led to a great success in sintering pure magnesium scaffolds. The resulting scaffolds with hierarchical and interconnected pores have great potential to be used as a bone-substituting material.


Assuntos
Substitutos Ósseos , Magnésio , Porosidade , Impressão Tridimensional , Solventes , Engenharia Tecidual , Alicerces Teciduais
6.
Acta Biomater ; 83: 153-166, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-30389577

RESUMO

Recently, lattice titanium manufactured by additive manufacturing (AM) techniques has been utilized in various applications, including biomedical. The effects of topological design and processing parameters on the fatigue behaviour of such meta-biomaterials have been studied before. Most studies show that the fatigue life of additively manufactured lattice structures is limited. Post-processing techniques could play a major role in improving the fatigue of these promising biomaterials. This study aims to provide an in-depth investigation into the effects of heat treatments, hot isostatic pressing (HIP), sand blasting, and chemical etching on the microstructure, surface morphology, strength and fatigue resistance of selective laser melted titanium meta-biomaterials. It was found that the combination of microstructural design and surface engineering, induced by HIP and sand blasting respectively, allows to increase the endurance limit of these lattice meta-biomaterials by a factor of two. HIP treatment substantially decreased the internal porosity and transformed the microstructure to a more ductile mixture of α +â€¯ß phases. Sand blasting allowed to eliminate surface imperfections and induced favourable compressive stress in the surface layer of the struts. STATEMENT OF SIGNIFICANCE: Additively manufactured metallic meta-biomaterials are progressively being used as bone replacement orthopedic implants. While there is a great amount of research related to topological designs and their effect on mechanical (e.g. stiffness), physical (e.g. mass transport), and biological (e.g. osseointegration) properties, fatigue lifetime of such structures remains limited. This study provides fundamental investigation into the combined effect of microstructural design and surface engineering of titanium meta-biomaterial, enabled through various post treatment methods ranging from heat treatments to physical and chemical surface modifications. The findings show that fatigue life is significantly improved by applying developed herein novel method, which effortlessly can be used on other bone-mimicking metallic meta-biomaterials.


Assuntos
Materiais Biocompatíveis/química , Substitutos Ósseos/química , Teste de Materiais , Titânio/química , Força Compressiva , Estresse Mecânico , Resistência à Tração
7.
J Biomed Mater Res A ; 106(7): 1798-1811, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29468807

RESUMO

Magnesium and its alloys have the intrinsic capability of degrading over time in vivo without leaving toxic degradation products. They are therefore suitable for use as biodegradable scaffolds that are replaced by the regenerated tissues. One of the main concerns for such applications, particularly in load-bearing areas, is the sufficient mechanical integrity of the scaffold before sufficient volumes of de novo tissue is generated. In the majority of the previous studies on the effects of biodegradation on the mechanical properties of porous biomaterials, the change in the elastic modulus has been studied. In this study, variations in the static and fatigue mechanical behavior of porous structures made of two different Mg alloys (AZ63 and M2) over different dissolution times ( 6, 12, and 24 h) have been investigated. The results showed an increase in the mechanical properties obtained from stress-strain curve (elastic modulus, yield stress, plateau stress, and energy absorption) after 6-12 h and a sharp decrease after 24 h. The initial increase in the mechanical properties may be attributed to the accumulation of corrosion products in the pores of the porous structure before degradation has considerably proceeded. The effects of mineral deposition was more pronounced for the elastic modulus as compared to other mechanical properties. That may be due to insufficient integration of the deposited particles in the structure of the magnesium alloys. While the bonding of the parts being combined in a composite-like material is of great importance in determining its yield stress, the effects of bonding strength of both parts is much lower in determining the elastic modulus. The results of the current study also showed that the dissolution rates of the studied Mg alloys were too high for direct use in human body. © 2018 Authors Journal of Biomedical Materials Research Part A Published by Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 1798-1811, 2018.


Assuntos
Ligas/química , Materiais Biocompatíveis/química , Magnésio/química , Estresse Mecânico , Módulo de Elasticidade , Porosidade , Espectrometria por Raios X , Fatores de Tempo , Microtomografia por Raio-X
8.
Acta Biomater ; 65: 292-304, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29127065

RESUMO

Additive manufacturing (AM) techniques enable fabrication of bone-mimicking meta-biomaterials with unprecedented combinations of topological, mechanical, and mass transport properties. The mechanical performance of AM meta-biomaterials is a direct function of their topological design. It is, however, not clear to what extent the material type is important in determining the fatigue behavior of such biomaterials. We therefore aimed to determine the isolated and modulated effects of topological design and material type on the fatigue response of metallic meta-biomaterials fabricated with selective laser melting. Towards that end, we designed and additively manufactured Co-Cr meta-biomaterials with three types of repeating unit cells and three to four porosities per type of repeating unit cell. The AM meta-biomaterials were then mechanically tested to obtain their normalized S-N curves. The obtained S-N curves of Co-Cr meta-biomaterials were compared to those of meta-biomaterials with same topological designs but made from other materials, i.e. Ti-6Al-4V, tantalum, and pure titanium, available from our previous studies. We found the material type to be far more important than the topological design in determining the normalized fatigue strength of our AM metallic meta-biomaterials. This is the opposite of what we have found for the quasi-static mechanical properties of the same meta-biomaterials. The effects of material type, manufacturing imperfections, and topological design were different in the high and low cycle fatigue regions. That is likely because the cyclic response of meta-biomaterials depends not only on the static and fatigue strengths of the bulk material but also on other factors that may include strut roughness, distribution of the micro-pores created inside the struts during the AM process, and plasticity. STATEMENT OF SIGNIFICANCE: Meta-biomaterials are a special class of metamaterials with unusual or unprecedented combinations of mechanical, physical (e.g. mass transport), and biological properties. Topologically complex and additively manufactured meta-biomaterials have been shown to improve bone regeneration and osseointegration. The mechanical properties of such biomaterials are directly related to their topological design and material type. However, previous studies of such biomaterials have largely neglected the effects of material type, instead focusing on topological design. We show here that neglecting the effects of material type is unjustified. We studied the isolated and combined effects of topological design and material type on the normalized S-N curves of metallic bone-mimicking biomaterials and found them to be more strongly dependent on the material type than topological design.


Assuntos
Ligas/química , Materiais Biocompatíveis/química , Teste de Materiais , Estresse Mecânico , Cromo/química , Cobalto/química , Manufaturas , Microscopia Eletrônica de Varredura , Porosidade
9.
Acta Biomater ; 67: 378-392, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29242158

RESUMO

An ideal bone substituting material should be bone-mimicking in terms of mechanical properties, present a precisely controlled and fully interconnected porous structure, and degrade in the human body to allow for full regeneration of large bony defects. However, simultaneously satisfying all these three requirements has so far been highly challenging. Here we present topologically ordered porous magnesium (WE43) scaffolds based on the diamond unit cell that were fabricated by selective laser melting (SLM) and satisfy all the requirements. We studied the in vitro biodegradation behavior (up to 4 weeks), mechanical properties and biocompatibility of the developed scaffolds. The mechanical properties of the AM porous WE43 (E = 700-800 MPa) scaffolds were found to fall into the range of the values reported for trabecular bone even after 4 weeks of biodegradation. Scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), electrochemical tests and µCT revealed a unique biodegradation mechanism that started with uniform corrosion, followed by localized corrosion, particularly in the center of the scaffolds. Biocompatibility tests performed up to 72 h showed level 0 cytotoxicity (according to ISO 10993-5 and -12), except for one time point (i.e., 24 h). Intimate contact between cells (MG-63) and the scaffolds was also observed in SEM images. The study shows for the first time that AM of porous Mg may provide distinct possibilities to adjust biodegradation profile through topological design and open up unprecedented opportunities to develop multifunctional bone substituting materials that mimic bone properties and enable full regeneration of critical-size load-bearing bony defects. STATEMENT OF SIGNIFICANCE: The ideal biomaterials for bone tissue regeneration should be bone-mimicking in terms of mechanical properties, present a fully interconnected porous structure, and exhibit a specific biodegradation behavior to enable full regeneration of bony defects. Recent advances in additive manufacturing have resulted in biomaterials that satisfy the first two requirements but simultaneously satisfying the third requirement has proven challenging so far. Here we present additively manufactured porous magnesium structures that have the potential to satisfy all above-mentioned requirements. Even after 4 weeks of biodegradation, the mechanical properties of the porous structures were found to be within those reported for native bone. Moreover, our comprehensive electrochemical, mechanical, topological, and biological study revealed a unique biodegradation behavior and the limited cytotoxicity of the developed biomaterials.


Assuntos
Materiais Biocompatíveis/farmacologia , Magnésio/farmacologia , Morte Celular/efeitos dos fármacos , Linhagem Celular Tumoral , Eletroquímica , Humanos , Porosidade , Propriedades de Superfície , Alicerces Teciduais/química , Microtomografia por Raio-X
10.
Am J Orthod Dentofacial Orthop ; 116(4): 460-8, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10511676

RESUMO

Functional appliances, which are used in the early treatment period of skeletal Class II malocclusions, induce the forward displacement of the mandible by altering the postural activity of the muscles and causing some changes in both skeletal and dentoalveolar structures. The purpose of this investigation was to evaluate the differences between monoblock and twin-block appliances. Two treatment groups composed of 26 growing patients with skeletal and dental Class II, Division 1, malocclusions, were compared to an untreated control group of 13 patients with the same morphologic characteristics and growth rate. These groups were matched according to their age, sex, and vertical and sagittal skeletal cephalometric and dental characteristics. Monoblock was worn by the subjects for 16 hours/day, whereas twin-block was worn 24 hours/day, even while eating. Patients of the control group were followed without any intervention. Treatment effects were identified with a conventional cephalometric analysis. The findings of this study revealed that by using these different functional appliances, the stimulation of the growth of the lower jaw and the correction of Angle Class II relationship were achieved. In the twin-block group, the mandibular plane angle and gonial angle increased, although a decrease in the degree of overbite occurred. In the monoblock group, upper incisors demonstrated a greater degree of retrusion. However, within the twin-block group, the lower incisors showed a greater degree of proclination.


Assuntos
Ossos Faciais/patologia , Má Oclusão Classe II de Angle/terapia , Mandíbula/patologia , Desenho de Aparelho Ortodôntico , Aparelhos Ortodônticos Funcionais , Dente/patologia , Estudos de Casos e Controles , Cefalometria , Feminino , Humanos , Incisivo/patologia , Masculino , Mandíbula/crescimento & desenvolvimento , Dente Molar/patologia , Fatores de Tempo , Dimensão Vertical
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA