Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Int J Comput Dent ; 26(1): 49-60, 2023 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-36825567

RESUMO

AIM: The present study aimed to develop a method for measuring 3D maxillary tooth movement during orthodontic treatment and to verify the accuracy of the method. MATERIALS AND METHODS: A 3D model analysis method was established to measure tooth movement by combining the effects of CBCT and intraoral scans. Transformation matrices were used to abstract the motion features of the teeth and translate them into translations and rotations. To test the validity and reliability of the method for clinical application, the inclination of the central incisor was measured using a 3D model analysis method and cephalometric analysis. Measurement error, correlation, and agreement between the two methods were analyzed using the Dahlberg formula, intraclass correlation coefficient, and Bland-Altman analysis, respectively. The performance of the 3D model analysis method was evaluated by monitoring the canine movement of a patient who underwent a premolar extraction. RESULTS: The measurement error was 0.58 degrees for the 3D model analysis and 2.02 degrees for the cephalometric analysis. There was no significant difference in the central incisor inclination measurements between the cephalometric and the 3D model analyses methods. A high correlation (0.974) and narrow limits of agreement (-3.55 degrees, 4.16 degrees) were obtained between the two methods. Minute movements and additional details of orthodontic tooth movements could be observed using the 3D model analysis method. CONCLUSION: The 3D model analysis method was reliable and reproducible for clinical application in monitoring the 3D maxillary tooth movement during orthodontic treatment. The trueness should be further evaluated. (Int J Comput Dent 2023;26(1): 49-0; doi: 10.3290/j.ijcd.b3818301).


Assuntos
Imageamento Tridimensional , Técnicas de Movimentação Dentária , Dente Pré-Molar , Imageamento Tridimensional/métodos , Maxila , Reprodutibilidade dos Testes , Ortodontia
2.
Artigo em Inglês | MEDLINE | ID: mdl-25648914

RESUMO

The V-W exponential hyperelastic model is adopted to describe the instantaneous elastic response of the periodontal ligament (PDL). The general theoretical framework of constitutive modeling is described based on nonlinear continuum mechanics, and the elasticity tensor used to develop UMAT subroutine is formulated. Nanoindentation experiment is performed to characterize mechanical properties of an adult pig PDL specimen. Then the experiment is simulated by using the finite element (FE) analysis. Meanwhile, the optimized material parameters are identified by the inverse FE method. The good agreement between the simulated results and experimental data demonstrates that the V-W model is capable of describing the mechanical behavior of the PDL. Therefore, the model and its implementation into FE code are validated. By using the model, we simulate the tooth movement under orthodontic loading to predict the mechanical responses of the PDL. The results show that local concentrations of stress and strain in the PDL are found.


Assuntos
Elasticidade , Análise de Elementos Finitos , Modelos Biológicos , Ligamento Periodontal/fisiologia , Animais , Fenômenos Biomecânicos , Simulação por Computador , Teste de Materiais , Dinâmica não Linear , Estresse Mecânico , Sus scrofa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA