Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Carbohydr Polym ; 304: 120482, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36641190

RESUMO

Bacterial cellulose (BC) has been explored for use in a range of applications including tissue engineering and textiles. BC can be produced from waste streams, but sustainable approaches are needed for functionalisation. To this end, BslA, a B. subtilis biofilm protein was produced recombinantly with and without a cellulose binding module (CBM) and the cell free extract was used to treat BC either ex-situ, through drip coating or in-situ, by incorporating during fermentation. The results showed that ex-situ modified BC increased the hydrophobicity and water contact angle reached 120°. In-situ experiments led to a BC film morphological change and mechanical testing demonstrated that addition of BslA with CBM resulted in a stronger, more elastic material. This study presents a nature inspired approach to functionalise BC using a biofilm hydrophobin, and we demonstrate that recombinant proteins could be effective and sustainable molecules for functionalisation of BC materials.


Assuntos
Bactérias , Celulose , Celulose/química , Bactérias/metabolismo , Engenharia Tecidual , Fermentação
2.
Eur Biophys J ; 39(8): 1219-27, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20054686

RESUMO

Atomic force microscopy (AFM)-based dynamic force spectroscopy of single molecular interactions involves characterizing unbinding/unfolding force distributions over a range of pulling speeds. Owing to their size and stiffness, AFM cantilevers are adversely affected by hydrodynamic forces, especially at pulling speeds >10 microm/s, when the viscous drag becomes comparable to the unbinding/unfolding forces. To circumvent these adverse effects, we have fabricated polymer-based membranes capable of actuating commercial AFM cantilevers at speeds >or=100 microm/s with minimal viscous drag effects. We have used FLUENT, a computational fluid dynamics (CFD) software, to simulate high-speed pulling and fast actuation of AFM cantilevers and membranes in different experimental configurations. The simulation results support the experimental findings on a variety of commercial AFM cantilevers and predict significant reduction in drag forces when membrane actuators are used. Unbinding force experiments involving human antibodies using these membranes demonstrate that it is possible to achieve bond loading rates >or=10(6) pN/s, an order of magnitude greater than that reported with commercial AFM cantilevers and systems.


Assuntos
Membranas Artificiais , Microscopia de Força Atômica/métodos , Análise Espectral/métodos , Autoanticorpos/química , Simulação por Computador , Humanos , Imunoglobulina G/química , Imunoglobulina G/imunologia , Polímeros/química , Ligação Proteica , Software , Viscosidade , Água , Xilenos/química
3.
ACS Sens ; 5(8): 2563-2569, 2020 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-32686395

RESUMO

Versatile, in situ sensing and continuous monitoring capabilities are critically needed, but challenging, for components made of solid woven carbon fibers in aerospace, electronics, and medical applications. In this work, we proposed a unique concept of integrated sensing technology on woven carbon fibers through integration of thin-film surface acoustic wave (SAW) technology and electromagnetic metamaterials, with capabilities of noninvasive, in situ, and continuous monitoring of environmental parameters and biomolecules wirelessly. First, we fabricated composite materials using a three-layer composite design, in which the woven carbon fiber cloth was first coated with a polyimide (PI) layer followed by a layer of ZnO film. Integrated SAW and metamaterials devices were then fabricated on this composite structure. The temperature of the functional area of the device could be controlled precisely using the SAW devices, which could provide a proper incubation environment for biosampling processes. As an ultraviolet light sensor, the SAW device could achieve a good sensitivity of 56.86 ppm/(mW/cm2). On the same integrated platform, an electromagnetic resonator based on the metamaterials was demonstrated to work as a glucose concentration monitor with a sensitivity of 0.34 MHz/(mg/dL).


Assuntos
Eletrônica , Som , Fibra de Carbono , Monitorização Fisiológica
4.
ACS Appl Mater Interfaces ; 7(39): 22018-28, 2015 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-26359763

RESUMO

Ophthalmic wireless microrobots are proposed for minimally invasive vitreoretinal surgery. Devices in the vitreous experience nonlinear mobility as a result of the complex mechanical properties of the vitreous and its interaction with the devices. A microdevice that will minimize its interaction with the macromolecules of the vitreous (i.e., mainly hyaluronan (HA) and collagen) can be utilized for ophthalmic surgeries. Although a few studies on the interactions between the vitreous and microdevices exist, there is no literature on the influence of coatings on these interactions. This paper presents how coatings on devices affect mobility in the vitreous. Surgical catheters in the vasculature use hydrophilic polymer coatings that reduce biomolecular absorption and enhance mobility. In this work such polymers, polyvinylpyrrolidone (PVP), polyethylene glycol (PEG), and HA coatings were utilized, and their effects on mobility in the vitreous were characterized. Hydrophilic titanium dioxide (TiO2) coating was also developed and characterized. Collagenase and hyaluronidase enzymes were coated on probes' surfaces with a view to enhancing their mobility by enzymatic digestion of the collagen and HA of the vitreous, respectively. To model the human vitreous, ex vivo porcine vitreous and collagen were used. For studying the effects of hyaluronidase, the vitreous and HA were used. The hydrophilic and enzymatic coatings were characterized by oscillatory magnetic microrheology. The statistical significance of the mean relative displacements (i.e., mobility) of the coated probes with respect to control probes was assessed. All studied hydrophilic coatings improve mobility, except for HA which decreases mobility potentially due to bonding with vitreal macromolecules. TiO2 coating improves mobility in collagen by 28.3% and in the vitreous by 15.4%. PEG and PVP coatings improve mobility in collagen by 19.4 and by 39.6%, respectively, but their improvement in the vitreous is insignificant at a 95% confidence level (CL). HA coating affects mobility by reducing it in collagen by 35.6% (statistically significant) and in the vitreous by 16.8% (insignificant change at 95% CL). The coatings cause similar effects in collagen and in the vitreous. However, the effects are lower in the vitreous, which can be due to a lower concentration of collagen in the vitreous than in the prepared collagen samples. The coatings based on enzymatic activity increase mobility (i.e., >40% after 15 min experiments in the vitreous models) more than the hydrophilic coatings based on physicochemical interactions. However, the enzymes have time-dependent effects, and they dissolve from the probe surface with time. The presented results are useful for researchers and companies developing ophthalmic devices. They also pave the way to understanding how to adjust mobility of a microdevice in a complex fluid by choice of an appropriate coating.


Assuntos
Materiais Revestidos Biocompatíveis/química , Colagenases/química , Teste de Materiais/métodos , Reologia/métodos , Cirurgia Vitreorretiniana/instrumentação , Animais , Humanos , Hialuronoglucosaminidase/química , Interações Hidrofóbicas e Hidrofílicas , Microcirurgia , Procedimentos Cirúrgicos Robóticos , Suínos
5.
Ultramicroscopy ; 122: 26-31, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22960003

RESUMO

The authors describe a method for biomolecular force clamp measurements using atomic force microscope (AFM) cantilevers and micromachined membrane-based electrostatic actuators. The actuators comprise of Parylene membranes with embedded side actuation electrodes and are fabricated on a silicon substrate. The devices have a displacement range of 1.8 µm with 200 V actuation voltage, and displacement uncertainty is 0.8 nm, including the noise and drift. The settling time, limited by the particular amplifier is 5 ms, with an inherent range down to 20 µs. A force clamp measurement setup using these actuators in a feedback loop has been used to measure bond life-times between human IgG and anti-human IgG molecules to demonstrate the feasibility of this method for biological experiments. The experimental findings are compared with a molecular pulling experiment and the results are found to be in good agreement.


Assuntos
Microscopia de Força Atômica/instrumentação , Microscopia de Força Atômica/métodos , Anticorpos Anti-Idiotípicos/análise , Anticorpos Anti-Idiotípicos/metabolismo , Materiais Biocompatíveis/química , Desenho de Equipamento , Humanos , Imunoglobulina G/análise , Imunoglobulina G/metabolismo , Fenômenos Mecânicos , Polímeros/química , Software , Eletricidade Estática , Xilenos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA