Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Cardiovasc Intervent Radiol ; 47(6): 730-740, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38816504

RESUMO

PURPOSE: In the present trial, the 24-month safety and effectiveness of the TCD-17187 drug-coated balloon (DCB) for the treatment of atherosclerotic lesions in the superficial femoral artery (SFA) and proximal popliteal artery (PA) were evaluated in Japanese patients. METHODS: This was a prospective, multicenter, core laboratory-adjudicated, single-arm trial. From 2019 to 2020, 121 patients with symptomatic peripheral artery disease were enrolled. The primary effectiveness outcome measure was primary patency. The safety outcome measure was the major adverse event (MAE) rate. RESULTS: Age was 74.5 ± 7.3 years, and diabetes mellitus was present in 67.5%. Lesion length and reference vessel diameter (RVD) were 106.0 ± 52.6 mm and 5.2 ± 0.8 mm, respectively. Chronic total occlusion (CTO) and bilateral calcification rate (Grade 3 and 4 by peripheral arterial calcium scoring system (PACSS)) were 17.5% and 50.8%, respectively. The 24-month primary patency rate by duplex ultrasound was 71.3%, while freedom from clinically driven target lesion revascularization (CD-TLR) was 87.0%. The MAE rate was 13.2% and all events consisted of CD-TLR. There were no instances of device- or procedure-related deaths major amputations throughout the 24 months. Multivariate Cox proportional hazards regression analysis revealed significant differences associated with loss of primary patency in the following characteristics: CTO, restenotic lesion and RVD. CONCLUSION: This trial confirmed the safety and effectiveness of TCD-17187 DCB for atherosclerotic lesions of the SFA and/or proximal PA for up to 24 months. LEVEL OF EVIDENCE: Level 3, Cohort study. CLINICAL TRIAL REGISTRATION: URL: https://center6.umin.ac.jp/cgi-open-bin/ctr/ctr.cgi?function=brows&action=brows&recptno=R000038612&type=summary&language=J:Registration ID: UMIN000034122. Registration Date: September 13, 2018.


Assuntos
Angioplastia com Balão , Materiais Revestidos Biocompatíveis , Artéria Femoral , Doença Arterial Periférica , Artéria Poplítea , Grau de Desobstrução Vascular , Humanos , Masculino , Artéria Poplítea/diagnóstico por imagem , Feminino , Idoso , Artéria Femoral/diagnóstico por imagem , Estudos Prospectivos , Doença Arterial Periférica/terapia , Doença Arterial Periférica/diagnóstico por imagem , Angioplastia com Balão/métodos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Japão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA