Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
N Engl J Med ; 350(3): 221-31, 2004 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-14724301

RESUMO

BACKGROUND: Restenosis after coronary stenting necessitates repeated percutaneous or surgical revascularization procedures. The delivery of paclitaxel to the site of vascular injury may reduce the incidence of neointimal hyperplasia and restenosis. METHODS: At 73 U.S. centers, we enrolled 1314 patients who were receiving a stent in a single, previously untreated coronary-artery stenosis (vessel diameter, 2.5 to 3.75 mm; lesion length, 10 to 28 mm) in a prospective, randomized, double-blind study. A total of 652 patients were randomly assigned to receive a bare-metal stent, and 662 to receive an identical-appearing, slow-release, polymer-based, paclitaxel-eluting stent. Angiographic follow-up was prespecified at nine months in 732 patients. RESULTS: In terms of base-line characteristics, the two groups were well matched. Diabetes mellitus was present in 24.2 percent of patients; the mean reference-vessel diameter was 2.75 mm, and the mean lesion length was 13.4 mm. A mean of 1.08 stents (length, 21.8 mm) were implanted per patient. The rate of ischemia-driven target-vessel revascularization at nine months was reduced from 12.0 percent with the implantation of a bare-metal stent to 4.7 percent with the implantation of a paclitaxel-eluting stent (relative risk, 0.39; 95 percent confidence interval, 0.26 to 0.59; P<0.001). Target-lesion revascularization was required in 3.0 percent of the group that received a paclitaxel-eluting stent, as compared with 11.3 percent of the group that received a bare-metal stent (relative risk, 0.27; 95 percent confidence interval, 0.16 to 0.43; P<0.001). The rate of angiographic restenosis was reduced from 26.6 percent to 7.9 percent with the paclitaxel-eluting stent (relative risk, 0.30; 95 percent confidence interval, 0.19 to 0.46; P<0.001). The nine-month composite rates of death from cardiac causes or myocardial infarction (4.7 percent and 4.3 percent, respectively) and stent thrombosis (0.6 percent and 0.8 percent, respectively) were similar in the group that received a paclitaxel-eluting stent and the group that received a bare-metal stent. CONCLUSIONS: As compared with bare-metal stents, the slow-release, polymer-based, paclitaxel-eluting stent is safe and markedly reduces the rates of clinical and angiographic restenosis at nine months.


Assuntos
Reestenose Coronária/prevenção & controle , Estenose Coronária/terapia , Paclitaxel/administração & dosagem , Stents , Idoso , Angioplastia Coronária com Balão , Angiografia Coronária , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Polímeros , Risco
2.
J Am Coll Cardiol ; 45(8): 1201-5, 2005 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-15837249

RESUMO

OBJECTIVES: The aim of this study was to use serial volumetric intravascular ultrasound (IVUS) to evaluate the effects of polymer-based, paclitaxel-eluting stents on in-stent neointima formation and late incomplete stent apposition. BACKGROUND: The TAXUS-IV trial demonstrated that the slow-release, polymer-based, paclitaxel-eluting stent reduces angiographic restenosis and the need for repeat revascularization procedures. Serial IVUS studies reveal details of the pattern of vascular responses provoked by stent implantation that provide insight into device safety and efficacy. METHODS: In the TAXUS-IV trial, patients were randomized to the slow-release, polymer-based, paclitaxel-eluting TAXUS stent or a bare-metal EXPRESS stent (Boston Scientific Corp., Natick, Massachusetts). As part of a formal substudy, complete volumetric IVUS data were available in 170 patients, including 88 TAXUS patients and 82 controls, at implantation and at nine-month follow-up. RESULTS: No baseline differences were present in the clinical characteristics or IVUS parameters between the control and TAXUS groups. At nine-month follow-up, IVUS lumen volumes were larger in the TAXUS group (123 +/- 43 mm(3) vs. 104 +/- 44 mm(3), p = 0.005), due to a reduction in neointimal volume (18 +/- 18 mm(3) vs. 41 +/- 23 mm(3), p < 0.001). Millimeter-by-millimeter analysis within the stent demonstrated uniform suppression of neointimal growth along the entire stent length. Late lumen loss was similar at the proximal edge of the stent between the two groups, and reduced with the TAXUS stent at the distal edge (p = 0.004). Incomplete stent apposition at nine months was observed in only 3.0% of control and 4.0% of TAXUS stents (p = 0.12). CONCLUSIONS: Polymer-based, paclitaxel-eluting TAXUS stents are effective in inhibiting neointimal tissue proliferation, and do not result in late incomplete stent apposition.


Assuntos
Antineoplásicos/administração & dosagem , Vasos Coronários/diagnóstico por imagem , Paclitaxel/administração & dosagem , Stents , Ultrassonografia de Intervenção , Doença das Coronárias/terapia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Polímeros , Túnica Íntima/diagnóstico por imagem
3.
Am J Cardiol ; 98(3): 331-7, 2006 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-16860018

RESUMO

We determined the outcomes of patients with acute ST-segment elevation (STE) myocardial infarction (STEMI) and non-STEMI (NSTEMI) after primary percutaneous coronary intervention (PCI). The prognosis after primary PCI in STEMI has been extensively studied and defined. Outcomes of patients who undergo primary PCI for NSTEMI are less well established. In total, 2,082 patients with ongoing chest pain for > 30 minutes consistent with acute MI were randomized to balloon angioplasty versus stenting, each with/without abciximab. Of 1,964 patients, STEMI was present in 1,725 (87.8%) and NSTEMI in 239 (12.2%). Compared with STEMI, those with NSTEMI were more likely to have delayed time-to-hospital arrival (2.4 vs 1.8 hours, p = 0.0002) and increased door-to-balloon time (3.2 vs 1.9 hours, p < 0.0001). Patients with NSTEMI were more likely to have Thrombolysis In Myocardial Infarction grade 3 flow at baseline (37.3% vs 19.4%, p < 0.0001) and higher ejection fraction (58.7% vs 55.8%, p = 0.001), but similar rates of postprocedural Thrombolysis In Myocardial Infarction grade 3 flow. At 1 year, patients with NTEMI had similar mortality (3.4% vs 4.4%, p = 0.40) but higher rates of major adverse cardiac events (24.0% vs 16.6%, p = 0.007) that was driven by more frequent ischemic target vessel revascularization (21.8% vs 11.9%, p <0.0001). In conclusion, patients with acute MI without STE who are treated with primary PCI have marked delays to treatment, similar late mortality, and increased rates of ischemic target vessel revascularization compared with patients with STEMI, despite more favorable angiographic features at presentation and similar reperfusion success. The adverse prognosis of patients with NSTEMI should be recognized and efforts made to decrease reperfusion times.


Assuntos
Angioplastia Coronária com Balão , Implante de Prótese Vascular/métodos , Eletrocardiografia , Infarto do Miocárdio/terapia , Abciximab , Idoso , Anticorpos Monoclonais/uso terapêutico , Anticoagulantes/uso terapêutico , Materiais Revestidos Biocompatíveis , Feminino , Seguimentos , Humanos , Fragmentos Fab das Imunoglobulinas/uso terapêutico , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/fisiopatologia , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/antagonistas & inibidores , Stents , Volume Sistólico/fisiologia , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
4.
Circulation ; 109(16): 1942-7, 2004 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-15078803

RESUMO

BACKGROUND: The safety and efficacy of the slow-release, polymer-based, paclitaxel-eluting stent after implantation in a broad cross section of de novo coronary lesions at 1 year are unknown. METHODS AND RESULTS: In the TAXUS-IV trial, 1314 patients with single de novo coronary lesions 10 to 28 mm in length, with reference-vessel diameter 2.5 to 3.75 mm, coverable by a single study stent, were prospectively randomized to the slow-release, polymer-based, paclitaxel-eluting TAXUS stent or an identical-appearing bare-metal EXPRESS stent. By actuarial analysis, the TAXUS stent compared with the bare-metal stent reduced the 12-month rates of target-lesion revascularization by 73% (4.4% versus 15.1%, P<0.0001), target-vessel revascularization by 62% (7.1% versus 17.1%, P<0.0001), target-vessel failure by 52% (10.0% versus 19.4%, P<0.0001), and composite major adverse cardiac events by 49% (10.8% versus 20.0%, P<0.0001). The 1-year rates of cardiac death (1.4% versus 1.3%), myocardial infarction (3.5% versus 4.7%), and subacute thrombosis (0.6% versus 0.8%) were similar between the paclitaxel-eluting and control stents, respectively. Between 9 and 12 months, there were significantly fewer myocardial infarctions (0% versus 1.1%, P=0.007), target-vessel revascularizations (2.4% versus 5.8%, P=0.002), and major adverse cardiac events (2.4% versus 6.3%, P=0.0009) in the paclitaxel-eluting stent than in the control stent group, respectively. CONCLUSIONS: The relative efficacy reported at 9 months for the polymer-based, paclitaxel-eluting TAXUS stent compared with the EXPRESS stent is preserved and continues to increase at 1 year, with no safety concerns apparent.


Assuntos
Reestenose Coronária/prevenção & controle , Estenose Coronária/terapia , Paclitaxel/administração & dosagem , Stents , Terapia Combinada , Angiografia Coronária , Reestenose Coronária/diagnóstico , Reestenose Coronária/epidemiologia , Preparações de Ação Retardada , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/uso terapêutico , Polímeros/química , Fatores de Risco , Stents/efeitos adversos , Resultado do Tratamento
5.
Expert Rev Med Devices ; 8(3): 303-6, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21542702

RESUMO

The Integrity Coronary Stent System (Medtronic Vascular, CA, USA) is a low-profile, open-cell, cobalt-chromium-alloy advanced bare-metal iteration of the well-known Driver/Micro-Driver Coronary Stent System (Medtronic Vascular). The Integrity stent is made with a process called continuous sinusoid technology. This process allows stent construction via wrapping a single thin strand of wire around a mandrel in a sinusoid configuration, with laser fusion of adjacent crowns. The wire-forming process and fusion pattern provide the stent with a continuous preferential bending plane, intended to allow easier access to, and smoother tracking within, distal and tortuous vessels while radial strength is maintained. Continuous sinusoid technology represents innovation in the design of stent platforms and will provide a future stent platform for newer technology, including drug-eluting stent platforms, drug-filled stents and core wire stents.


Assuntos
Desenho de Prótese/métodos , Stents , Ligas de Cromo , Ensaios Clínicos como Assunto , Humanos
6.
J Am Coll Cardiol ; 51(16): 1543-52, 2008 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-18420096

RESUMO

OBJECTIVES: The aim was to compare safety and effectiveness of the CoStar drug-eluting stent (DES) (Conor MedSystems, Menlo Park, California) with those of the Taxus DES (Boston Scientific, Maple Grove, Minnesota) in de novo single- and multivessel percutaneous coronary intervention (PCI). BACKGROUND: Paclitaxel elution from a stent coated with biostable polymer (Taxus) reduces restenosis after PCI. The CoStar DES is a novel stent with laser-cut reservoirs containing bioresorbable polymer loaded to elute 10 microg paclitaxel/30 days. METHODS: Patients undergoing PCI for a single target lesion per vessel in up to 3 native epicardial vessels were randomly assigned 3:2 to CoStar or Taxus. Primary end point was 8-month major adverse cardiac events (MACE), defined as adjudicated death, myocardial infarction (MI), or clinically driven target vessel revascularization (TVR). Protocol-specified 9-month angiographic follow-up included 457 vessels in 286 patients. RESULTS: Of the 1,700 patients enrolled, 1,675 (98.5%) were evaluable (CoStar = 989; Taxus = 686), including 1,330 (79%) single-vessel and 345 (21%) multivessel PCI. The MACE rate at 8 months was 11.0% for CoStar versus 6.9% for Taxus (p < 0.005), including adjudicated death (0.5% vs. 0.7%, respectively), MI (3.4% vs. 2.4%, respectively), and TVR (8.1% vs. 4.3%, respectively). Per-vessel 9-month in-segment late loss was 0.49 mm with CoStar and 0.18 mm with Taxus (p < 0.0001). Findings were consistent across pre-specified subgroups. CONCLUSIONS: The CoStar DES is not noninferior to the Taxus DES based on per-patient clinical and per-vessel angiographic analyses. The relative benefit of Taxus is primarily attributable to reduction in TVR. Follow-up to 9 months showed no apparent difference in death, MI, or stent thrombosis rates.


Assuntos
Implantes Absorvíveis , Antineoplásicos Fitogênicos/administração & dosagem , Ligas de Cromo , Doença da Artéria Coronariana/tratamento farmacológico , Reestenose Coronária/tratamento farmacológico , Paclitaxel/administração & dosagem , Polímeros , Angioplastia Coronária com Balão , Antineoplásicos Fitogênicos/uso terapêutico , Clopidogrel , Angiografia Coronária , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Reestenose Coronária/mortalidade , Reestenose Coronária/fisiopatologia , Diabetes Mellitus , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/uso terapêutico , Inibidores da Agregação Plaquetária/administração & dosagem , Risco , Tromboembolia/prevenção & controle , Ticlopidina/administração & dosagem , Ticlopidina/análogos & derivados , Fatores de Tempo
7.
J Am Coll Cardiol ; 49(16): 1676-83, 2007 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-17448368

RESUMO

OBJECTIVES: The goal of this research was to assess non-inferiority of the next-generation TAXUS Liberté stent (Boston Scientific Corp., Natick, Massachusetts) versus the TAXUS Express stent (Boston Scientific Corp.). BACKGROUND: The introduction of drug-eluting stents (DES) has shifted clinical practice towards more complex lesion subsets, prompting the need for more deliverable DES. TAXUS Liberté was designed to combine the established polymer-based, paclitaxel-elution TAXUS technology with the more advanced Liberté stent platform. METHODS: The TAXUS ATLAS study is a global, prospective, single-arm trial evaluating outcomes in de novo coronary lesions visually estimated to be 10 to 28 mm in length in vessels 2.5 to 4.0 mm in diameter. The control group is an entry-criteria-matched population of TAXUS Express patients from the TAXUS IV and V trials. The primary end point is non-inferiority of TAXUS Liberté versus TAXUS Express for 9-month target vessel revascularization. RESULTS: Despite similar inclusion criteria, quantitative coronary angiography-determined baseline lesion characteristics were significantly more complex for TAXUS Liberté than TAXUS Express. The primary non-inferiority end point was met with the 1-sided 95% confidence bound of 2.98% less than the pre-specified non-inferiority margin of 3% (p = 0.0487). CONCLUSIONS: Despite the treatment of more complex lesions with TAXUS Liberté, the primary end point was met, demonstrating that TAXUS Liberté is non-inferior to TAXUS Express. The successful transfer of the proven TAXUS technology to the more advanced TAXUS Liberté platform was demonstrated. (TAXUS ATLAS: TAXUS Liberté-SR Stent for the Treatment of De Novo Coronary Artery Lesions; http://www.clinicaltrials.gov/ct/show/NCT00371709?order=1; NCT00371709).


Assuntos
Estenose Coronária/tratamento farmacológico , Neovascularização Fisiológica/efeitos dos fármacos , Paclitaxel/administração & dosagem , Stents , Moduladores de Tubulina/administração & dosagem , Idoso , Determinação de Ponto Final , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polímeros , Estudos Prospectivos
8.
Catheter Cardiovasc Interv ; 68(3): 379-88, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16892434

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the clinical and angiographic outcomes of the Symbiot ePTFE covered stent versus bare metal stents (BMS) for the treatment of saphenous vein graft (SVG) disease. BACKGROUND: The Symbiot stent was developed to reduce periprocedural complications, by potentially preventing distal embolization, and to serve as a possible barrier to cell migration, thus reducing restenosis. METHODS: Symbiot III is a prospective, randomized trial of 400 patients at 45 US sites, with 201 patients in the Symbiot group and 199 in the BMS group. Randomization was stratified based on the intended use of embolic protection devices and glycoprotein IIb/IIIa inhibitors. The primary endpoint was percent diameter stenosis (%DS) as measured by quantitative coronary angiography at 8 months. Secondary endpoints included MACE (cardiac death, MI, TVR). RESULTS: The groups were well matched for all baseline clinical and lesion characteristics. At 8 months, %DS was comparable between groups (30.9% Symbiot, 31.9% BMS, P = 0.80). Although the rates of binary restenosis in the stented segment were similar (29.1% Symbiot, 21.9% BMS, P = 0.17), more patients in the Symbiot group had binary restenosis at the proximal edge (9.0% Symbiot, 1.8% BMS, P = 0.0211). There was no difference in the incidence of MACE between groups (30.6% Symbiot, 26.6% BMS, P = 0.43). CONCLUSIONS: This study failed to show an advantage for the Symbiot stent in the treatment of degenerated SVGs. This PTFE covered stent does not appear to act as a barrier to prevent restenosis.


Assuntos
Materiais Revestidos Biocompatíveis/uso terapêutico , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Veia Safena/transplante , Stents , Adulto , Idoso , Implante de Prótese Vascular , Canadá , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Determinação de Ponto Final , Seguimentos , Humanos , Pessoa de Meia-Idade , Politetrafluoretileno/uso terapêutico , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA