Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 93(2): 208-215, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30298593

RESUMO

OBJECTIVES: To compare the effectiveness and safety of self-expandable, sirolimus-eluting Stentys stents (SES) and second-generation drug-eluting stents (DES-II) for the treatment of the unprotected left main (ULM). BACKGROUND: SES may provide a valuable option to treat distal ULM, particularly when significant caliber gaps with side branches are observed. METHODS: Patients from the multicenter SPARTA (clinicaltrials.gov: NCT02784405) and FAILS2 registries were included. Propensity-score with matching was performed to account for the lack of randomization. Primary end-point was the rate of major adverse cardiovascular events (MACE, a composite of all cause death, myocardial infarction, target lesion revascularization [TLR], unstable angina and definite stent thrombosis [ST]). Single components of MACE were the secondary end-points. RESULTS: Overall, 151 patients treated with SES and 1270 with DES-II were included; no differences in MACE rate at 250 days were observed (9.8% vs. 11.5%, P = 0.54). After propensity score with matching, 129 patients treated with SES and 258 with DES-II, of which about a third of female gender, were compared. After a follow-up of 250 days, MACE rate did not differ between the two groups (9.9% vs. 8.5%, P = 0.66), as well as the rate of ULM TLR (1.6% vs. 3.1%, P = 0.36) and definite ST (0.8% vs. 1.2%, P = 0.78). These results were consistent also when controlling for the treatment with provisional vs. 2-stents strategies for the ULM bifurcation. CONCLUSION: SES use for ULM treatment was associated with a similar MACE rate compared to DES-II at an intermediate-term follow-up. SES might represent a potential option in this setting.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Stents Metálicos Autoexpansíveis , Sirolimo/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Ligas , Fármacos Cardiovasculares/efeitos adversos , Pesquisa Comparativa da Efetividade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 92(7): 1247-1255, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-30244520

RESUMO

BACKGROUND: Covered stent (CS) implantation is considered a useful device in the setting of Grade III Coronary Perforation (G3CP), one of the most harmful PCI complication. However, data regarding efficacy of this device and clinical outcomes are still limited. METHODS AND RESULTS: From 1993 to 2015, among 97,779 patients from 9 European centres undergoing PCI, 224 patients had G3CP (0.23%), and 102 patients were managed with CS implantation (96 with PTFE, 6 with pericardium). Device oriented composite endpoint (DOCE), a composite of cardiac death, target lesion revascularization, and stent thrombosis (ST) in-hospital and at long term follow-up were evaluated. G3-CP perforations were successfully sealed with CS in 88 patients (86.3%) with need of intraprocedural pericardiocentesis in one-third of cases. Protamine as heparin reversal agent was administered in 36 (35%) of cases. The cumulative incidence of in-hospital DOCE were 16.6% (17/102): death 14.7%, TLR 2.9%, ST 3.9%. At long-term follow-up (mean 42 ± 38 months), DOCE rates occurred in 19.7%: death 7.4%, TLR 11%, and ST 6.2%. Indication to Dual Antiplatelet Therapy (DAPT) was lifelong in 20% of cases, 1 to 6 months in 22.5% and 12-months in 57.5% without differences in long-term DOCE before and after DAPT interruption (8.0 vs. 6.6%, respectively, P = 0.20). CONCLUSIONS: Use of CS was successful in sealing grade 3 coronary artery perforations in the majority of cases. Beside the high rate of clinical events at short and long-term, ST remains the leading cause of device failure.


Assuntos
Vasos Coronários/lesões , Traumatismos Cardíacos/terapia , Intervenção Coronária Percutânea/instrumentação , Pericárdio/transplante , Politetrafluoretileno , Stents , Lesões do Sistema Vascular/terapia , Idoso , Idoso de 80 Anos ou mais , Vasos Coronários/diagnóstico por imagem , Europa (Continente) , Feminino , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/mortalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA