Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Infect Chemother ; 27(7): 1058-1062, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33934920

RESUMO

INTRODUCTION: Rapid antigen detection (RAD) tests are convenient tools for detecting the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in clinics, and testing using saliva samples could decrease the risk of infection during sample collection. This study aimed to assess the accuracy of the SARS-CoV-2 RAD for testing of nasopharyngeal swab specimens and saliva samples in comparison with the RT-PCR tests and viral culture for detecting viable virus. METHODS: One hundred seventeen nasopharyngeal swab specimens and 73 saliva samples with positive results on RT-PCR were used. Residual samples were assayed using a commercially available RAD test immediately, and its positivity was determined at various time points during the clinical course. The concordance between 54 nasopharyngeal swab samples and saliva samples that were collected simultaneously was determined. Viral culture was performed on 117 samples and compared with the results of the RAD test. RESULTS: The positive rate of RAD test using saliva samples was low throughout the clinical course. Poor concordance was observed between nasopharyngeal swab specimens and saliva samples (75.9%, kappa coefficient 0.310). However, a substantially high concordance between the RAD test and viral culture was observed in both nasopharyngeal swab specimens (86.8%, kappa coefficient 0.680) and saliva samples (95.1%, kappa coefficient 0.643). CONCLUSIONS: The sensitivity of the SARS-CoV-2 RAD test was insufficient, particularly for saliva samples. However, a substantially high concordance with viral culture suggests its potential utility as an auxiliary test for estimating SARS-CoV-2 viability.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Nasofaringe , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Saliva
2.
J Infect Chemother ; 24(10): 856-859, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29705391

RESUMO

Some infectious diseases, such as infective endocarditis, osteomyelitis, and abscesses, require treatment with long-term intravenous antimicrobial treatment. Therefore, the patient is required to stay in the hospital to receive therapy, which lowers their quality of life. Establishing an outpatient parenteral antimicrobial therapy (OPAT) by continuous infusion pump is desired in Japan to overcome these issues. However, the 24-h stability of antimicrobial agents dissolved in infusion solutions is unclear. Thus, we investigated the stability of antimicrobial agents in five different infusion solutions in a clinical setting. Benzylpenicillin potassium (PCG) and ampicillin (ABPC) were dissolved separately in five different infusion solutions and kept at 25 or 31.1 °C for 24 h. The residual ratios were determined by high-performance liquid chromatography (HPLC). Dissolved PCG in acetate ringer solution remained stable for 24 h at temperatures of 25 and 31.1 °C (101.7 ± 1.4% and 92.9 ± 1.3%, respectively). In addition, the PCG solution did not adsorb onto the elastomeric infusion pump after 24 h at 31.1 °C. PCG dissolved in acetate ringer solution was also stable for 10 days after being kept in an elastomeric infusion pump at 4 °C (99.7 ± 0.5%). ABPC was unstable in all of the tested infusion solutions and temperatures. Based on our results, PCG in acetate ringer solution can be used in OPAT with continuous infusion pumps.


Assuntos
Ampicilina/administração & dosagem , Ampicilina/química , Antibacterianos/administração & dosagem , Antibacterianos/química , Bombas de Infusão , Penicilina G/administração & dosagem , Penicilina G/química , Estabilidade de Medicamentos , Elastômeros , Humanos , Concentração de Íons de Hidrogênio , Infusões Intravenosas , Soluções Isotônicas/administração & dosagem , Soluções Isotônicas/química , Japão , Temperatura , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA