Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Biomech Eng ; 145(9)2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37195691

RESUMO

Short dental implants with platform matching connection have been used for the rehabilitation of atrophic jaws whenever standard-length dental implants cannot be placed without prior bone augmentation. Yet, there remains a lack of data regarding the risk of technical failures when the all-on-4 configuration is performed in atrophic jaws with platform-switching distal short dental implants. Thus, the current study used the finite element method to evaluate the mechanical behavior at the level of the prosthetic components of the all-on-4 concept performed in atrophic mandible using short-length distal implants with platform switching (PSW) connection. Three models of the all-on-4 configuration were generated in human atrophic mandibles. The geometric models consisted of PSW connection tilted standard (AO4T; θ = 30 deg; 11 mm-length), straight standard (AO4S; θ = 0 deg; 11 mm-length) and straight short (AO4Sh; θ = 0 deg; 8 mm-length) distal implants. A resultant force of 300 N was performed obliquely in the left side and posterior region of the prosthetic bar. The von Mises equivalent stress (σvm) and maximum and minimum principal stresses (σmax and σmin) were performed at level of the prosthetic components/implants and peri-implant bone crest, respectively. The general displacement of the models was also evaluated. The stress analysis was performed on the side of load application. The AO4S configuration showed the lowest values of σvm in the mesial left (ML) and distal left (DL) abutments (37.53 MPa and 232.77 MPa, respectively) and dental implants (91.53 MPa and 231.21 MPa, respectively). The AO4Sh configuration showed the highest values of σvm in the bar screw (102.36 MPa), abutment (117.56 MPa), and dental implant (293.73 MPa) of the ML area. Among the models, the highest values of σmax and σmin were noticed in the peri-implant bone crest of the AO4T design (131.48 MPa and 195.31 MPa, respectively). All models showed similar values of general displacements, which were concentrated in the mandible symphysis. The all-on-4 configurations designed with PSW connection and tilted standard (AO4T; θ = 30 deg; 11 mm-length), straight standard (AO4S; θ = 0 deg; 11 mm-length) or straight short (AO4Sh; θ = 0 deg; 8 mm-length) distal implants were not associated with higher odds of technical failures. The AO4Sh design may be a promising option for the prosthetic rehabilitation of atrophic jaws.


Assuntos
Implantes Dentários , Humanos , Estresse Mecânico , Análise de Elementos Finitos , Mandíbula/cirurgia , Análise do Estresse Dentário
2.
J Mater Sci Mater Med ; 34(5): 21, 2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37118367

RESUMO

High implant survival rates have been achieved in recent decades due to continual modifications in implant design and surface topography, however there is still an ongoing quest to control peri-implant bone loss. The objective of this work was to develop Ti-35Nb-7Zr-5Ta (TNZT) alloys, perform physicochemical and morphological characterization of their surface modified by electrolytic oxidative plasma technique with ions related to osseointegration and lastly evaluate bacterial colonization in vitro. Three groups were evaluated: C group (polished TNZT), CaP group (sodium ß glycerophosphate + calcium acetate) and Mg group (magnesium acetate). Before and after anodizing the surfaces, physicochemical and morphological analyses were performed: scanning electron microscopy with field emission gun (FEG-SEM), energy dispersion spectroscopy (EDS), X-ray diffraction (DRX), wettability (goniometer) and roughness (rugometer). Controlled and treated specimens were contaminated with unstimulated saliva collected from 10 healthy volunteers. Then, biofilm samples were collected and up to 35 microbial species, including commensal and pathogenic microorganisms, were identified and quantified by the Checkerboard DNA-DNA Hybridization method. The CaP group modified the surface morphology in the form of pores, while the Mg group modified it in the form of flakes. The contact angle was significantly smaller in the CaP group. The average roughness was higher in the CaP and Mg groups. A smaller total amount of bacteria was identified in the Mg group and relevant differences were found in the microbial profile associated with different surface treatments. Therefore, considering the microbiological profile and for the prevention of peri-implantitis, the Mg group presented more satisfactory and encouraging results for the manufacture of dental implants.


Assuntos
Cálcio , Implantes Dentários , Humanos , Fosfatos , Magnésio , Ligas/química , Microscopia Eletrônica de Varredura , DNA , Titânio/química , Propriedades de Superfície
3.
Am J Orthod Dentofacial Orthop ; 159(1): 86-96, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33223377

RESUMO

INTRODUCTION: Computer-aided design and manufacturing (CAD-CAM) systems have assisted orthodontists to position brackets virtually. The purpose of this study was to evaluate if a CAD-CAM system could predict the orthodontic treatment outcome of patients with Angle Class I malocclusion with mild crowding or spacing and with no need for orthodontic extraction. METHODS: Using the American Board of Orthodontics Cast-Radiograph Evaluation (ABO-CRE) and color map superimposition, the treated occlusion was compared with the virtual final occlusion of 24 young adults with Class I occlusion. Using eXceed software (eXceed, Witten, Germany), we created the final occlusion prediction for each patient (virtual set up group). A digital model of the final occlusion of each patient was created (treated occlusion group). ABO-CRE score was used to compare groups. In addition, a color map was created for all subjects to access the mean and range values between the virtual set up model and treated occlusion model of each patient. Random and systematic errors were calculated. In addition, chi-square and t test were used. RESULTS: Comparisons between virtual set up occlusion and treated occlusion showed statistically significant differences in 3 out of 7 measurements: interproximal contact score was larger for treated than virtual occlusion (0.45 mm and 0.04 mm, respectively), and the treated occlusion showed larger values than the virtual occlusion for occlusal contacts (14.13 mm and 7.62 mm, respectively) and overjet (7.37 mm and 0.66 mm, respectively). Although the treated occlusion showed a larger score than the virtual occlusion (50.41 mm and 34.58 mm, respectively), there is no significant difference between both. Root angulation decreased (from 1.95 ± 1.29 to 0.65 ± 0.71) because of the treatment. CONCLUSIONS: ABO-CRE overall score presents no difference between groups. In addition, CAD-CAM setup occlusion closely predicts the final teeth alignment and leveling with interarch relationships showing less ABO-CRE score deduction.


Assuntos
Má Oclusão Classe I de Angle , Má Oclusão , Sobremordida , Desenho Assistido por Computador , Humanos , Má Oclusão Classe I de Angle/diagnóstico por imagem , Má Oclusão Classe I de Angle/terapia , Modelos Dentários , Adulto Jovem
4.
Biofouling ; 35(2): 173-186, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30935231

RESUMO

The chemical composition of biomaterials can drive their biological responses; therefore, this in vitro study aimed to evaluate the proteomic profile of the salivary pellicle formed on titanium (Ti) alloys containing niobium (Nb) and zirconium (Zr). The experimental groups consisted of Ti35NbxZr (x = 5 and 10 wt%) alloys, and commercially pure titanium (cpTi); titanium aluminium vanadium (Ti6Al4V) alloys were used as controls. The physical and chemical characteristics of the Ti materials were analysed. The proteomic profile was evaluated by liquid chromatography coupled with tandem mass spectrometry. Bacterial adhesion (2 h) of mixed species (Streptococcus sanguinis and Actinomyces naeslundii) was investigated as colony-forming units (n = 6). This paper reports the finding that salivary pellicle composition can be modulated by the composition of the Ti material. The Ti35NbxZr group showed a significant ability to adsorb proteins from saliva, which can favour interactions with cells and compatibility with the body.


Assuntos
Ligas/química , Película Dentária/química , Nióbio/química , Proteoma/análise , Proteínas e Peptídeos Salivares/análise , Titânio/química , Zircônio/química , Adsorção , Aderência Bacteriana , Materiais Biocompatíveis/química , Proteômica
5.
J Prosthet Dent ; 111(4): 301-9, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24355510

RESUMO

STATEMENT OF PROBLEM: In dental rehabilitations that involve implants, the number of implants is sometimes smaller than the number of lost teeth. This fact can affect the biomechanical behavior and success of the implants. PURPOSE: The purpose of this study was to investigate the mechanical behavior of different implant positions in the rehabilitation of the anterior maxilla. MATERIAL AND METHODS: Three-dimensional models of the maxilla were created based on computed tomography images for 3 different anterior prosthetic rehabilitations. In group IL, the implants were placed in the lateral incisor positions with pontics in the central incisor positions; in group IC, the implants were in the central incisor positions with cantilevers in the lateral incisor positions; and, in group ILIC, one implant was in a lateral incisor position and one was in a central incisor position, with a pontic and a cantilever in the remaining positions. A 150 N load was distributed and applied at the center of the palatal surface of each tooth at a 45-degree angle to the long axis of the tooth. The resulting stress-strain distribution was analyzed for each group. RESULTS: The lowest displacement of the prosthetic structure was observed in group IC, although the same group exhibited the largest displacement of the bone tissue. In the bone tissue, the von Mises stress was mainly observed in the cortical bone in all groups. The maximum value of the von Mises stress shown in the cortical tissue was 35 MPa in the implant that neighbors the cantilever in group ILIC. The maximum von Mises stress in the trabecular bone was 3.5 MPa. CONCLUSION: The prosthetic configuration of group IC limited the displacement of the prosthetic structure but led to greater displacement of the bone structure. The use of a cantilever increased the stress concentration in the implant and in the bone structure adjacent to the cantilever under the conditions studied here.


Assuntos
Arco Dental/patologia , Implantes Dentários , Arcada Parcialmente Edêntula/reabilitação , Maxila/patologia , Fenômenos Biomecânicos , Ligas de Cromo/química , Simulação por Computador , Dente Suporte , Materiais Dentários/química , Prótese Dentária Fixada por Implante , Planejamento de Dentadura , Prótese Parcial , Módulo de Elasticidade , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional/métodos , Incisivo , Modelos Biológicos , Estresse Mecânico , Propriedades de Superfície , Titânio/química , Tomografia Computadorizada por Raios X/métodos
6.
Dent Mater J ; 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38825448

RESUMO

The aim of this study was to evaluate the effects of the application of universal adhesive in the etch-and-rinse (ER) strategy with a manual brush (MB) or rotary brush (RB) in adhesion to dentin impregnated (WB) or not (NB) with bioceramic sealer, at 24 h and 1 year. Eighty-eight crowns of bovine incisors were divided into four groups (n=22): WB-MB, WB-RB, NB-MB, NB-RB. After the restorative protocol, dentin penetrability was evaluated by confocal microscopy. Bond strength was evaluated by microtensile test. Data were analyzed using one-way ANOVA/Tukey tests (α=0.05). NB-RB and WB-RB exhibited greater extensions of resin tags in dentin. At 24 h, WB-RB and NB-MB showed the highest and lowest values of bond strength, respectively. At 1 year, WB-MB and WB-RB demonstrated the highest bond strength values. The RB increases the formation of resin tags and residues of bioceramic sealer provides higher bond strength in the ER strategy.

7.
Dent Mater J ; 43(1): 126-135, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38072410

RESUMO

The objective of the study was to evaluate the effects of dentin deproteinization protocols for post space using different formulations containing sodium hypochlorite before fiber post cementation with self-adhesive resinous cement. The groups were divided according to the irrigation protocol (DWC, SHS, SHT and SHG). The residue cleanliness, bond strength, adhesive failure pattern, and tag formation at the adhesive interface between the self-adhesive cement and the dentin were evaluated. For this, analysis in scanning electron microscope, push-out test and confocal laser scanning microscopy were performed. The SHT protocol showed the highest residue cleanliness on the dentin surface of the post space (p<0.05). In addition, SHT protocol showed highest bond strength and tag formation in the cervical and middle thirds (p<0.05). Dentin deproteinization with sodium hypochlorite with surfactant provided the best dentin cleaning of residues, bond strength and tag formation after cementation of the fiber post with self-adhesive cement.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Cimentação/métodos , Tensoativos/farmacologia , Hipoclorito de Sódio/farmacologia , Hipoclorito de Sódio/química , Cimentos de Resina/química , Dentina , Teste de Materiais
8.
Dent Mater J ; 43(1): 112-118, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38072411

RESUMO

This study evaluated the influence of different translucent resins (Z350 and Opallis) for customizing fiber posts and light-curing the cementation system using different LED equipment (V, Valo or R, Radii-Cal) on the bond strength and adhesive failure pattern at 24 h and 6 months. Eighty roots were prepared and divided into 4 groups (n=20): ZV (Z350 resin and LED Valo), ZR (Z350 resin and LED Radii-Cal), OV (Opallis resin and LED Valo), OR (Opallis resin and LED Radii-Cal). After post space preparation, the fiber post was customized and cemented with self-adhesive cement and light-curing using V or R LED equipment. Bond strength values were submitted to 2-way ANOVA test. ZV and ZR showed higher bond strength values than the other groups at 6 months of evaluation (p<0.05). The Z350 resin has a favorable influence on the bond strength of self-adhesive cement to root dentin, regardless of the LED polymerization equipment used.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Resinas Compostas/química , Cimentação , Cimentos de Resina/química , Dentina , Teste de Materiais , Vidro/química
9.
Dent Mater J ; 42(6): 878-885, 2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-37793825

RESUMO

The study evaluated the persistence of residues, bond strength and tags formation of a cementation system after post-space irrigation with different sodium hypochlorite-based irrigants. The groups were divided according to the irrigation protocol (DW: distilled water; SHS: sodium hypochlorite solution; SHG: sodium hypochlorite gel; and, SHT: sodium hypochlorite with surfactant). Forty roots (n=10) were used to evaluate the persistence of residues by scanning electron microscopy. Other forty roots were used to the push-out bond strength test, failure mode and tag formation analyses. Non-parametric data were submitted to Kruskal Wallis and Dunn tests, while parametric data were evaluated by one-way ANOVA. No difference was observed in the persistence of residues. DW showed the highest bond strength and tag formation. Type 2 failure mode was the most frequent in the experimental groups. Compared to control, SHT showed the best performance, since less negative effects on adhesive interface was observed.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Cimentação/métodos , Hipoclorito de Sódio/farmacologia , Hipoclorito de Sódio/química , Dentina , Irrigantes do Canal Radicular , Cimentos de Resina/química , Teste de Materiais
10.
Dent Mater J ; 42(5): 654-658, 2023 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-37460305

RESUMO

This study evaluated the variation of surface and intra-pulpal temperature, during bleaching protocol, using LED/laser. The 35% (HP35), 15% (HP15) and 6% (HP6) gels were used associated with LED/laser applied every 1 min for 30 min in a human canine. The evaluation of surface temperature variation (∆Ts) was performed using a pHmeter and the intra-pulpal temperature variation (∆Ti) was performed using a digital thermometer, at times of 1-, 5-, 10- 15- and 30-min. Statistical analysis was performed using the two-way repeated measures ANOVA test and Bonferroni post-hoc test was used at a significance level of 5%. HP35 and HP15 showed greater temperature variation than HP6 up to 10 min of surface evaluation, showing no differences between them. In the intra-pulpal evaluation, no group showed differences throughout the procedure.


Assuntos
Clareadores Dentários , Clareamento Dental , Humanos , Temperatura , Peróxido de Hidrogênio , Luz , Lasers
11.
Biomed Phys Eng Express ; 8(4)2022 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-35594845

RESUMO

The titanium alloy composition and microdesign affect the dynamic interplay between the bone cells and titanium surface in the osseointegration process. The current study aimed to evaluate the surface physicochemical properties, electrochemical stability, and the metabolic response of the MC3T3-E1 cells (pre-osteoblast cell line) cultured onto titanium-15molybdenum (Ti-15Mo) discs treated with phosphoric acid (H3PO4) and sodium hydroxide (NaOH) and/or strontium-loading by the hydrothermal method. The x-ray dispersive energy spectroscopy (EDS) and x-ray diffraction (XRD) analysis showed no trace of impurities and the possible formation of hydrated strontium oxide (H2O2Sr), respectively. The confocal laser microscopy (CLSM) analysis indicated that titanium samples treated with strontium (Sr) showed greater surface roughness. The acid/alkali treatment prior to the hydrothermal Sr deposition improved the surface free energy and resistance to corrosion of the Ti-15Mo alloy. The acid/alkali treatment also provided greater retention of the Sr particles on the Ti-15Mo surfaces accordingly with inductively coupled plasma optical emission spectrometry (ICP-OES) analysis. The AlamarBlue and fluorescence analysis indicated noncytotoxic effects against the MC3T3-E1 cells, which allowed cells' adhesion and proliferation, with greater cells' spreading in the Sr-loaded Ti-15Mo samples. These findings suggest that Sr deposition by the hydrothermal method has the potential to enhance the physicochemical properties of the Ti-15Mo previously etched with H3PO4and NaOH, and also improve the initial events related to cell-mediated bone deposition.


Assuntos
Estrôncio , Titânio , Ligas/farmacologia , Proliferação de Células , Hidróxido de Sódio/farmacologia , Estrôncio/química , Estrôncio/farmacologia , Propriedades de Superfície , Titânio/química , Titânio/farmacologia
12.
Microorganisms ; 9(10)2021 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-34683474

RESUMO

This study evaluated the microbial colonization (adhesion and biofilm) on modified surfaces of a titanium alloy, Ti-35Nb-7Zr-5Ta, anodized with Ca and P or F ions, with and without silver deposition. The chemical composition, surface topography, roughness (Ra), and surface free energy were evaluated before and after the surface modifications (anodizing). Adhesion and biofilm formation on saliva-coated discs by primary colonizing species (Streptococcus sanguinis, Streptococcus gordonii, Actinomyces naeslundii) and a periodontal pathogen (Porphyromonasgingivalis) were assessed. The surfaces of titanium alloys were modified after anodizing with volcano-shaped micropores with Ca and P or nanosized with F, both with further silver deposition. There was an increase in the Ra values after micropores formation; CaP surfaces became more hydrophilic than other surfaces, showing the highest polar component. For adhesion, no difference was detected for S. gordonii on all surfaces, and some differences were observed for the other three species. No differences were found for biofilm formation per species on all surfaces. However, S. gordonii biofilm counts on distinct surfaces were lower than S. sanguinis, A. naeslundii, and P. gingivalis on some surfaces. Therefore, anodized Ti-35Nb-7Zr-5Ta affected microbial adhesion and subsequent biofilm, but silver deposition did not hinder the colonization of these microorganisms.

13.
Int J Oral Maxillofac Implants ; 25(5): 911-9, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20862404

RESUMO

PURPOSE: To evaluate the influence of platform switching on the biomechanical environment of implants in different placement and loading protocols. MATERIALS AND METHODS: A computed tomography-based finite element model of a maxillary central incisor extraction socket was constructed containing a conical 13-mm external-hex implant with a 4.3-mm-diameter shoulder. Abutment models that were 4.3 mm and 3.8 mm in diameter were then imported and aligned to the implant. The 4.3-mm abutment edge matched perfectly the edge of the implant shoulder, while the 3.8-mm abutment assumed a platform-switching configuration. Then, immediately placed, immediately loaded, and osseointegrated (ie, conventional delayed loaded) protocols were simulated. Analysis of variance was used to interpret the data for peak equivalent strain (EQV strain) in the bone, bone-to-implant relative displacement, peak von Mises stress (EQV stress) in the abutment screw, and implant-abutment gap. RESULTS: In the same clinical situation, the differences in the values of the assessed results were minor for abutments of different diameters. In addition, no statistically significant influence of the abutment diameter was seen on any of the evaluated biomechanical parameters, except for the bone-to-implant displacement, although this was observed in a rather low percentage. Nevertheless, a slightly higher EQV stress in the abutment screw was seen in all cases for the 3.8-mm-diameter abutment, although this was not statistically significant. CONCLUSION: Within the limitation of this finite element analysis, it can be concluded that a circumferential horizontal mismatch of 0.5 mm does not make an important contribution to the biomechanical environment of implants. Also, there seems to be no significant biomechanical drawback to the design rationale of reducing the abutment diameter to move the implant-abutment gap area away from the implant-bone interface.


Assuntos
Simulação por Computador , Dente Suporte , Implantes Dentários , Planejamento de Prótese Dentária , Análise do Estresse Dentário , Alvéolo Dental/cirurgia , Fenômenos Biomecânicos , Implantação Dentária Endóssea/métodos , Análise do Estresse Dentário/métodos , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional , Carga Imediata em Implante Dentário , Maxila/diagnóstico por imagem , Modelos Biológicos , Osseointegração , Tomografia Computadorizada por Raios X
14.
Dental Press J Orthod ; 25(1): 28-35, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32215475

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the effect of the Yd:YAG laser irradiation on orthodontic bracket base surface. Shear bond strength (SBS) values and sites of the bonding failure interfaces were quantified. METHODS: Brackets were divided into two groups: OP (One Piece - integral sandblast base) and OPL (One Piece - laser irradiation). The brackets were randomly bonded on an intact enamel surface of 40 bovine incisors. The SBS tests were carry out using a universal test machine. A stereomicroscopy was used to evaluate the adhesive remnant index (ARI), and surface characterization was performed by scanning electron microscopy (SEM). Student's t-test was used to compare the SBS between the two groups (p< 0.05). Frequencies and chi-square analysis were applied to evaluate the ARI scores. RESULTS: OPL group showed higher value (p< 0.001) of SBS than OP group (43.95 MPa and 34.81 MPa, respectively). ARI showed significant difference (p< 0.001) between OPL group (ARI 0 = 100%) and OP group (ARI 0 = 15%). SEM showed a higher affinity between the adhesive and the irradiated laser base surface. CONCLUSIONS: Yd:YAG laser irradiation on bracket base increased SBS values, showing that bonding failure occurs at the enamel/adhesive interface. Laser-etched bracket base may be used instead of conventional bases in cases where higher adhesion is required, reducing bracket-bonding failure.


Assuntos
Colagem Dentária , Lasers de Estado Sólido , Braquetes Ortodônticos , Animais , Bovinos , Humanos , Metais , Resistência ao Cisalhamento , Propriedades de Superfície
15.
Braz Dent J ; 31(6): 657-663, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33237238

RESUMO

The aim of this study was to evaluate the effect of cleaning solutions on the retention force of o-ring-type overdenture attachments. The effect of four solutions on nitrile rings were evaluated: Cepacol (C), Cepacol with fluoride (CF), Listerine (L) and 0.05% sodium hypochlorite (SH); deionized water (DW) was used as a control. Matrices containing two implants and abutments and acrylic specimens with the metal capsules were obtained and divided into the groups. A simulation of 90 overnight immersions (8 h) was performed, and the tensile strength value was obtained at the beginning (T0) and in every 30 days (T1, T2 and T3) (n=6). In order to analyze o-ring surface damage after the immersions, a scanning electron microscopy (SEM) was used (n=1). For statistical analysis of the results, analysis of variance (ANOVA) and multiple comparisons with Bonferroni adjustment (test power=1.000; a=0.05) were used. There was a significant difference for the factors time (p<0.001), solution (p<0.001) and for the interaction time × solution (p<0.001). Considering the times of each solution, only for DW there was no significant loss of retention over time. Comparing the solutions in each moment, there was no difference among the solutions in T0. From T1, CF and SH provided less retention than DW (p<0.005). Through SEM it was possible to observe changes in the surface of the CF and SH nitrile o-rings. CF and SH should be avoided due to deleterious action in o-rings.


Assuntos
Revestimento de Dentadura , Hipoclorito de Sódio , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Retenção de Dentadura , Teste de Materiais , Resistência à Tração
16.
J Mater Sci Mater Med ; 20(8): 1629-36, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19337820

RESUMO

Titanium is used due its excellent properties in medical and dentistry areas. With the objective of exploiting better mechanical properties, not altering its biocompatibility, it was intended to add niobium and zirconium to the titanium, being formulated two alloys Ti-35%Nb-5%Zr (alloy 1) and Ti-35%Nb-10%Zr (alloy 2) wt% produced by an arc melting method. The chemical analysis of the samples was accomplished by X-ray fluorescence, and the microstrutural evaluation by scanning electron microscopy and X-ray diffraction. The mechanical tests were: Vickers hardness, tensile strength, mechanical cycling, and fracture analysis. The results allowed characterizing the alloy 1 as alpha + beta type and the alloy 2 as beta type. It is found that the alloy 1 presented larger hardness and smaller tensile strength than the alloy 2. The fractures, after the tensile test, were of the ductile type and, after the mechanical cycling, they were of the mixed type for both alloys.


Assuntos
Ligas/química , Moldes Cirúrgicos , Nióbio/química , Titânio/química , Zircônio/química , Ligas/síntese química , Ligas Dentárias/síntese química , Ligas Dentárias/química , Técnica de Fundição Odontológica/instrumentação , Dureza/fisiologia , Teste de Materiais , Estresse Mecânico , Resistência à Tração/fisiologia , Difração de Raios X
17.
J Prosthet Dent ; 102(2): 74-80, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19643220

RESUMO

STATEMENT OF PROBLEM: Implant-retained overdentures are a treatment option for patients who are not satisfied with conventional complete dentures. Although implant-retained overdentures are widely used, little data are available or provided by implant manufacturers about retentive strength and wear of attachments. PURPOSE: The purpose of this study was to evaluate retentive strength and fatigue resistance of 4 overdenture bar-and-clip attachment systems. MATERIAL AND METHODS: Forty bar-and-clip attachment system specimens were tested (n=10): Conexão Bar Clip (polymer clip), Sterngold Hader Bar (polymer clip), 3i Gold Hader Type Clip (metal clip), or SIN Clipo (metal clip). Specimens immersed in artificial saliva were tested to 5500 cycles at 0.8 Hz using a servohydraulic universal testing machine. Retention strength values (N) were recorded initially and after 1100, 2200, 3300, 4400, and 5500 insertion and removal cycles during the tensile test using a speed of 1 mm/min and a load cell of 1 kN. Data were submitted to a 2-way repeated-measures ANOVA and the Tukey A post hoc test (alpha = .05). RESULTS: An increase in retention strength values was observed during the fatigue test after 5500 cycles of insertion and removal. No significant difference in retentive strength was observed in the groups using polymer clips (Conexão Bar Clip and Sterngold Hader Bar) (P=.729); the same occurred with metal clip systems (SIN Clipo and 3i Gold Hader Type Clip) (P=.068). The SIN Clipo system demonstrated the smallest retention strength values, which were significantly different from the other 2 attachment systems, the Sterngold Hader Bar (P<.01) and the Conexão Bar Clip (P<.01). Although the 3i Gold Hader Type Clip did not differ significantly, in terms of retentive strength, from the Sterngold Hader Bar (P=.258), its retentive strength was significantly lower than the retentive strength of the Conexão Bar Clip system (P=.030). CONCLUSIONS: The systems evaluated demonstrated satisfactory retention for all time periods tested, as retention strengths from 5 to 7 N should be sufficient to stabilize overdentures. No component fracture or compromise in retention was found for any of the systems tested.


Assuntos
Prótese Dentária Fixada por Implante , Retenção de Dentadura/instrumentação , Revestimento de Dentadura , Análise do Estresse Dentário , Teste de Materiais , Metais , Polímeros , Saliva Artificial , Resistência à Tração
18.
J Prosthodont ; 18(2): 130-4, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19054308

RESUMO

PURPOSE: The objective of this study was to assess the influence of a fluoride medium with different pHs on the corrosion resistance of three commercially pure titanium-based dental implant commercial brands, under scanning electron microscopy (SEM) and EDS. MATERIALS AND METHODS: Forty-two dental implants, from three commercial brands, were used. Five years of regular use of mouth rinsing, with NaF 1500 ppm content and two different pHs, were simulated by immersing the specimens into that medium for 184 hours. RESULTS: SEM and EDS analyses demonstrated no evidence of corrosion on the specimens' surfaces after being submitted to fluoride ions or incorporation of fluoride ions to the set surface. CONCLUSION: It was possible to conclude that both the fluoride concentration and the pH of the solutions did not exert any influence upon implant corrosion resistance.


Assuntos
Cariostáticos/química , Implantes Dentários , Materiais Dentários/química , Fluoretos/química , Titânio/química , Corrosão , Planejamento de Prótese Dentária , Microanálise por Sonda Eletrônica , Humanos , Concentração de Íons de Hidrogênio , Imersão , Teste de Materiais , Microscopia Eletrônica de Varredura , Antissépticos Bucais/química , Propriedades de Superfície , Fatores de Tempo
19.
J Prosthodont ; 18(5): 382-7, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19432761

RESUMO

PURPOSE: The influence of fatigue and the fluoride ion corrosion process on Streptococcus mutans adherence to commercially pure Titanium (Cp Ti) implant/component set surfaces were studied. MATERIALS AND METHODS: Thirty Nobel implants and 30 Neodent implants were used. Each commercial brand was divided into three groups. Group A: control, Group B: sets submitted to fatigue (10(5) cycles, 15 Hz, 150 N), and Group C: sets submitted to fluoride (1500 ppm, pH 5.5) and fatigue, simulating a mean use of 5 years in the oral medium. Afterward, the sets were contaminated with standard strains of S. mutans (NTCC 1023) and analyzed by scanning electronic microscopy (SEM) and colony-forming unit counts (CFU/mL). RESULTS: By SEM, bacterial adherence was verified only in group C in both brands. By CFU/mL counts, S. mutans was statistically higher in both brands in group C than in groups A and B (p < 0.05, ANOVA). CONCLUSION: The process of corrosion by fluoride ions on Cp Ti implant/component sets allowed greater S. mutans adherence than in the absence of corrosion and with the fatigue process in isolation.


Assuntos
Aderência Bacteriana , Implantes Dentários/microbiologia , Fluoretos/química , Titânio/química , Análise de Variância , Cariostáticos/química , Corrosão , Materiais Dentários/química , Análise do Estresse Dentário , Eletroquímica , Contaminação de Equipamentos , Teste de Materiais , Streptococcus mutans , Estresse Mecânico , Propriedades de Superfície
20.
Clin Implant Dent Relat Res ; 20(3): 274-279, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29380490

RESUMO

BACKGROUND: Changes in the macrogeometry of dental implants are known to influence primary stability and the osseointegration process. PURPOSE: The purpose of the present in vitro study was to evaluate the mechanical behavior of geometric changes in the apex region of dental implants. METHODS: Thirty-five cylindrical dental implants (Titamax Ti; Neodent) were machined at the apical third to reproduce the experimental groups: without apical cut (Wc), apical bi-split cut, apical tri-split cut, apical quadri-split cut (Qs). One (control group) (Titamax Ti Ex) (n = 7) without any modifications was added. The implants had the same final dimensions (4.1 x 11 mm2 ). All implants were inserted into artificial bone blocks and were evaluated by insertion torque and resonance frequency by ISQ values (Osstell). Two-tailed analysis of variance (One-way ANOVA) and Tukey's post-test (P < .05). RESULTS: Control and Qs implants showed a significant increase of the insertion torque (P < .001). For the resonance frequency, Wc and (control) implants had the greatest ISQ values. However, there's no significant difference between (control) and Qs for the ISQ values (P < .001). CONCLUSION: Within the limitations of the present study, the proposed geometries at the apical third of dental implants greatly influenced its insertion torque and primary stability in vitro.


Assuntos
Implantação Dentária Endóssea , Implantes Dentários , Retenção em Prótese Dentária , Torque , Vibração , Fenômenos Químicos , Planejamento de Prótese Dentária , Análise do Estresse Dentário , Fenômenos Geológicos , Técnicas In Vitro , Osseointegração , Propriedades de Superfície , Titânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA