Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Catheter Cardiovasc Interv ; 92(3): 488-496, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29068171

RESUMO

OBJECTIVES: To assess the safety and efficacy of everolimus-eluting bioresorbable scaffolds (BRS) in the treatment of chronic total occlusions (CTO) using noninvasive multislice computed tomography (MSCT) angiography at one-year follow-up. BACKGROUND: Current evidence regarding the safety and efficacy of BRS for the percutaneous treatment of CTO is limited. METHODS: Between September 2013 and January 2016, patients who received one or more ABSORB BRSs were included at three centers. MSCT (including quantitative analysis) and clinical follow-up were performed at one year. RESULTS: Forty-one CTO patients were included. Mean age was 60 ± 11 years and the majority was male (83%). Average Japanese CTO (J-CTO) score was 0.9 ± 0.9. Seventy-one BRS were implanted in total with, on average, 1.7 ± 0.8 scaffolds/patient, and a total length of 43 ± 20 mm and diameter of 3.1 ± 0.4 mm. One noncardiac death took place. MSCT angiography was performed in 34 (83%) patients: all scaffolds were patent, except in one patient, in whom a patent target vessel was present on subsequent diagnostic angiography. MSCT quality was sufficient for quantitative analyses in 27 patients (46 scaffolds): median reference versus scaffold minimal lumen diameter and minimal lumen area were measured, and showed a small difference of 0.1 mm (-0.2-0.4) (lumen diameter stenosis = 3.0%) and 0.5 mm2 (-1.0-2.0) (lumen area stenosis = 4.2%). CONCLUSIONS: The low number of events and high patency rate at 1 year are encouraging the further use of the ABSORB scaffold for CTOs with low J-CTO score. Noninvasive MSCT angiography is a valid tool to assess scaffold patency, although its image resolution limits the use for quantitative measurements.


Assuntos
Implantes Absorvíveis , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Intervenção Coronária Percutânea/instrumentação , Idoso , Fármacos Cardiovasculares/administração & dosagem , Doença Crônica , Materiais Revestidos Biocompatíveis , Oclusão Coronária/fisiopatologia , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Europa (Continente) , Everolimo/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
2.
Catheter Cardiovasc Interv ; 86(7): 1141-50, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-25044635

RESUMO

OBJECTIVES: We studied coronary vasomotion in patients treated with the Mistent(®) absorbable polymer sirolimus-eluting stent (APSES) and in patients implanted with the Endeavor(®) zotarolimus-eluting stent (ZES). BACKGROUND: First generation (1st-gen) drug-eluting stents (DES) induce persistent vasomotor dysfunction in the treated coronary artery. It is unknown whether and to what extent the implantation of an absorbable polymer DES impairs coronary vasomotion. METHODS: This sub-study of the DESSOLVE II trial included 19 APSES Mistent(®) and 10 ZES Endeavor(®) patients. Incremental atrial pacing and quantitative coronary angiography were used to assess vasomotion proximal and distal to the stent and in a reference segment at 9 months after implantation. Percent changes in vessel diameter with pacing versus baseline were calculated and compared. Vasomotor response of the APSES group was also compared with changes observed in a historical group of 17 patients implanted with a 1st-gen sirolimus-eluting stent (SES). RESULTS: Normal vasomotion (vasodilatation) was preserved and of comparable magnitude in the APSES and in the ZES group both proximally (P = 0.34) and distally (P = 0.38) to the stent. This finding was not observed in the 1st-gen SES group showing marked pacing-induced vasoconstriction at both stent edges (P < 0.05 vs. APSES). The results were practically unchanged after excluding patients with absolute changes in vessel diameter <3% between baseline and maximal pacing. CONCLUSIONS: The implantation of an absorbable polymer sirolimus-eluting stent is associated with preserved coronary vasomotion, comparable to that observed after implantation of the Endeavor(®) ZES, and distinct from 1st-gen SES which induce coronary vasomotor dysfunction.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/fisiopatologia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros , Sirolimo/administração & dosagem , Vasodilatação , Idoso , Estimulação Cardíaca Artificial , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Europa (Continente) , Feminino , Estudo Historicamente Controlado , Humanos , Masculino , Pessoa de Meia-Idade , Nova Zelândia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Método Simples-Cego , Sirolimo/análogos & derivados , Fatores de Tempo , Resultado do Tratamento , Vasoconstrição
3.
Acta Cardiol ; 68(1): 1-9, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23457903

RESUMO

OBJECTIVES: The long-term clinical outcome of covered stents in the percutaneous treatment of diseased saphenous vein graft (SVG) has been disappointing. The single self-expanding polytetrafluoroethylene (PTFE)-covered Symbiot stent with a unique profile may present advantages that translate into superior long-term clinical outcomes. This study evaluated the safety, effectiveness and clinical outcome of the Symbiot covered stent system (Boston Scientific, Natick, Mass.) and FilterWire EX (Boston Scientific, Natick, Mass.) versus bare metal stents (BMS) in SVG intervention. METHODS AND RESULTS: Between January 2003 and August 2005, 90 patients with degenerative SVG lesions were prospectively randomized at 6 study sites to Symbiot implantation (n = 30), BMS with FilterWire as embolic protection device (EPD, n = 30), or BMS without EPD (control group, n = 30). The primary end point was reduction in peri-procedural cardiac enzyme rise. The major secondary end points were in-hospital, 6-month and long-term target vessel failure rates, defined as the cumulative of death, myocardial infarction and clinically driven target lesion revascularization. There was no significant reduction in median [IQR] post-procedural troponin-I rise in the Symbiot group compared to the FilterWire or the control group (0.08 [0-1.40] microg/l; 0.06 [0-0.28] microg/l; and 0.04 [0-0.31] microg/l, P = 0.58). At 7.4 +/- 1.3 (mean +/- SD) years, there were numerically less deaths in the Symbiot group, although this did not reach statistical significance (P = 0.20). There was no significant difference in TVF-free survival between the treatment groups (P = 0.98). CONCLUSION: This study failed to show a procedural or long-term clinical advantage for the Symbiot PTFE-covered stent in the treatment of degenerated SVG.


Assuntos
Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Politetrafluoretileno , Veia Safena/transplante , Stents , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo
4.
Int J Cardiol ; 301: 50-55, 2020 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-31759686

RESUMO

OBJECTIVES: Long-term data from randomized studies on polymer-free stents are scarce. Long-term data of Cre8 amphilimus eluting stent are still not available. We sought to investigate contribution of a polymer-free design versus a permanent-polymer one on the long-term. METHODS AND RESULTS: Patients undergoing percutaneous coronary intervention for de novo lesions were randomized 1:1 to Cre8 or Taxus Liberté (323 overall, 126 Cre8). Original primary endpoint (6-month angiographic in-stent late lumen loss) already demonstrated the superiority of Cre8 vs Taxus (0.14 + 0.36 mm vs. 0.34 + 0.40 mm; p < 0.001). Secondary endpoints were the device oriented composite endpoint (DOCE), patient oriented composite endpoint (POCE) up to 5-year. Long-term follow-up data confirmed the superiority shown by Cre8 in the analysis of the angiographic endpoint at 6-month, especially in the diabetic patients, where the device strongly reduced the clinical difference with non-diabetic. Landmark analysis demonstrated that the incidence of DOCE after 1-year and up to 5-year follow up was significantly lower in patients implanted with Cre8 AES (2.1% Cre8 vs. 9.3% Taxus, p = 0.009). While no differences were found in terms of DOCE rate among diabetic and non-diabetic patients treated with the Cre8 AES (HR 1.039; 95%CI 0.320-3.374), this was not true for Taxus (HR 2.64; 95%CI 1.112-6.278). CONCLUSIONS: Cre8 showed favourable safety and efficacy results versus Taxus at 5-years follow-up, with a superior clinical performance for the DOCE endpoint from 1 to 5 years. Cre8, differently from Taxus, has been able to strongly reduce the differences in clinical outcome between diabetic and non-diabetic up to 5 years, suggesting the higher efficacy of Cre8 in the treatment of diabetic patients.


Assuntos
Doença da Artéria Coronariana , Vasos Coronários , Paclitaxel/farmacologia , Intervenção Coronária Percutânea/instrumentação , Sirolimo/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Stents Farmacológicos/classificação , Ácidos Graxos/farmacologia , Feminino , Humanos , Imunossupressores/farmacologia , Efeitos Adversos de Longa Duração , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/estatística & dados numéricos , Polímeros/farmacologia , Desenho de Prótese , Resultado do Tratamento
5.
EuroIntervention ; 13(18): e2147-e2151, 2018 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-29278354

RESUMO

AIMS: The aim of this study was to evaluate the five-year clinical results of a sirolimus-eluting stent (MiStent SES) with a bioabsorbable coating designed for sustained drug delivery during and after rapid polymer dissolution. METHODS AND RESULTS: The five-year results from the DESSOLVE I and II trials including major adverse cardiac events (MACE), target lesion failure (TLF), target vessel failure (TVF), and stent thrombosis (ST) at five-year follow-up are reported. In DESSOLVE I, 10.3% of patients receiving the MiStent SES (3/29) had a MACE event up to five years without TLF. In DESSOLVE II, 15.1% of patients in the MiStent group (18/119) had a five-year MACE event compared to 22.0% of patients in the Endeavor group (p=0.295). TLF was 9.2% in the MiStent group and 8.5% in the Endeavor group (p=1.00). TVF was 10.1% for MiStent versus 15.3% for Endeavor (p=0.331). Up to five-year follow-up, the MiStent SES has continued to demonstrate low rates of TLR across DESSOLVE I (0.0%) and DESSOLVE II (3.4%). No ST was reported with the MiStent up to five years in the DESSOLVE I trial. In DESSOLVE II, definite or probable ST was 0.0% with MiStent and 1.7% with Endeavor up to five years. CONCLUSIONS: The MiStent SES demonstrated long-term safety and effectiveness with low rates of five-year MACE, TLF, and TVF across these two clinical trials.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Sirolimo/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Cristalização , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
6.
EuroIntervention ; 14(5): e570-e579, 2018 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-28994655

RESUMO

AIMS: Quantitative flow ratio (QFR) based on three-dimensional quantitative coronary angiography (3D-QCA) is a novel method to assess physiological functionality after treatment with stents. The current study aimed to evaluate the difference in physiological functionality nine months after implantation of a bioresorbable polymer-based sirolimus-eluting stent with an electrografting base layer (BuMA Supreme: B-SES) versus a durable polymer-based zotarolimus-eluting stent (Resolute: R-ZES). METHODS AND RESULTS: The current post hoc analysis was performed in the PIONEER randomised trial (1:1 randomisation to B-SES [83 patients/95 lesions] and R-ZES [87 patients/101 lesions]). QFR was measured in stented vessels in both arms at preprocedural, post-procedural and nine-month angiography without pharmacologically induced hyperaemia (contrast QFR). At nine months, both the values of QFR distal to the stent (B-SES: 0.89±0.10 vs. R-ZES: 0.89±0.11, p=0.97) and the number of vessels with QFR ≤0.8 were not significantly different between the two groups (11.0% vs. 12.8%, p=0.72), while the in-stent binary restenosis rate was also comparable (3.7% vs. 3.5%, p=1.00). QFR gradient across the device (∆QFR) at nine months was also similar between the groups (B-SES: 0.03±0.04 vs. R-ZES: 0.03±0.07, p=0.95). CONCLUSIONS: Quantitative flow assessment nine months after stenting did not differ between B-SES and R-ZES, despite a significant difference in in-stent late lumen loss.


Assuntos
Reestenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Angiografia Coronária , Humanos , Polímeros , Desenho de Prótese , Sirolimo/análogos & derivados , Stents , Resultado do Tratamento
7.
JACC Cardiovasc Interv ; 10(20): 2029-2037, 2017 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-28964764

RESUMO

OBJECTIVES: The aim of this first-in-human study was to assess the safety and effectiveness of the Virtue sirolimus-eluting balloon in a cohort of patients with in-stent restenosis (ISR). BACKGROUND: Angioplasty balloons coated with the cytotoxic drug paclitaxel have been widely used for ISR treatment. The Virtue angioplasty balloon (Caliber Therapeutics, New Hope, Pennsylvania) delivers sirolimus in a nanoencapsulated liquid formulation. This clinical trial is the first to examine a sirolimus-eluting balloon for ISR. METHODS: In this prospective, single-arm feasibility study at 9 European centers, 50 ISR patients were treated with the Virtue balloon. Angiographic measurements at 6 months are reported, along with 12-month clinical follow-up. RESULTS: Procedural success in the intention-to-treat population was 100%. The primary safety endpoint was target lesion failure (TLF) (cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization) assessed at 30 days (0%, n = 50). The primary performance endpoint was in-segment late lumen loss (LLL) at 6 months (0.31 ± 0.52 mm; n = 47). Secondary 6-month endpoints include binary restenosis (19.1%), diameter stenosis (30.3 ± 19.9%), and major adverse cardiac events (MACE) (10.2%, n = 49). In the 36-patient per-protocol population (excluding major protocol violations and previously stented ISR), LLL was 0.12 ± 0.33 mm at 6 months. Clinical outcomes at 1 year for the intention-to-treat group were 12.2% TLF and 14.3% MACE and for the per-protocol population were 2.8% TLF and 2.8% MACE. CONCLUSIONS: This first-in-human study showed excellent procedural success for the Virtue sirolimus-eluting angioplasty balloon, 6-month LLL rates in line with current stent-free ISR treatment options, and clinical outcomes that warrant further evaluation in dedicated randomized studies.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Angiografia Coronária , Reestenose Coronária/terapia , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Stents , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Desenho de Equipamento , Europa (Continente) , Estudos de Viabilidade , Feminino , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
8.
EuroIntervention ; 11(5): 541-8, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25136883

RESUMO

AIMS: To report the six-month angiographic and two-year clinical outcome data from the first-in-man study with the Ultimaster DES, a thin-strut cobalt-chromium sirolimus-eluting stent (SES) with an innovative abluminal-gradient-coated bioresorbable polymer. METHODS AND RESULTS: CENTURY is a multicentre, single-arm, prospective study that enrolled 105 patients (113 lesions) with coronary artery disease. All patients were scheduled to have an angiographic follow-up at six months, while 45 and 20 patients respectively had IVUS and OCT assessments. The primary endpoint was six-month in-stent late lumen loss. Secondary endpoints included clinical, IVUS and OCT outcomes. Clinical follow-up is available up to two years and will continue up to five years. Procedural success was 97.1% and device success was 100%. Angiographic late loss at six months was 0.04±0.35 mm, also reflected in a low binary restenosis rate of 0.9% and confirmed by IVUS-assessed neointimal volume obstruction of 1.02±1.62%. The mean strut coverage assessed by OCT was 96.2% with 1.66±4.02 malapposed stent struts. There were no deaths in the study, three (2.9%) periprocedural and one (0.9%) spontaneous myocardial infarction, not related to the target vessel. At one and two years, the target lesion failure rate was 3.8% and 5.7%, while the TLR rate was 1.9% and 2.8%, respectively. There was one acute definite stent thrombosis. CONCLUSIONS: The Ultimaster™ novel bioresorbable polymer sirolimus-eluting stent demonstrated good performance, including high procedural success and strong suppression of neointimal proliferation at six months. Good safety and effectiveness were shown up to two years in the studied population.


Assuntos
Antibióticos Antineoplásicos/uso terapêutico , Ligas de Cromo , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Neointima , Intervenção Coronária Percutânea , Polímeros , Sirolimo/uso terapêutico , Implantes Absorvíveis , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/terapia , Estudos Prospectivos , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção
9.
EuroIntervention ; 10(12): 1383-90, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24801119

RESUMO

AIMS: To compare the efficacy and safety of the MiStent absorbable polymer sirolimus-eluting stent (APSES) with a zotarolimus-eluting stent (ZES). METHODS AND RESULTS: The trial was a 2:1 randomisation at 26 sites of 184 patients implanted with an APSES (n=123) versus a ZES (n=61). Following stent implantation, all patients underwent quantitative coronary angiography at baseline and at nine months of follow-up, while a select subgroup also underwent optical coherence tomography (OCT). The primary efficacy hypothesis was superiority of in-stent late lumen loss (LLL) of APSES compared to ZES. At nine months, the primary endpoint was met, with a mean in-stent LLL of 0.27±0.46 mm in 103 APSES patients versus 0.58±0.41 mm in 52 ZES patients (p<0.001). The proportion of uncovered stent struts by OCT at nine months was very low in both groups. The mean neointimal thickness of covered struts (p=0.002) and percent net volume obstruction (p≤0.003) were significantly lower in the APSES than in the ZES group. Major adverse cardiac event and stent thrombosis rates were low and comparable between groups. CONCLUSIONS: The DESSOLVE II trial demonstrated superiority in the primary efficacy endpoint of nine-month mean LLL for APSES compared to ZES. Strut coverage by OCT was high with both stents and the clinical safety endpoints including stent thrombosis were equally low in both groups. ClinicalTrials.gov Identifier: NCT01294748.


Assuntos
Implantes Absorvíveis , Antibióticos Antineoplásicos/uso terapêutico , Reestenose Coronária/patologia , Estenose Coronária/terapia , Stents Farmacológicos , Neointima/patologia , Intervenção Coronária Percutânea/métodos , Sirolimo/análogos & derivados , Sirolimo/uso terapêutico , Idoso , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neointima/diagnóstico por imagem , Polímeros , Método Simples-Cego , Tomografia de Coerência Óptica , Resultado do Tratamento
10.
JACC Cardiovasc Interv ; 6(10): 1026-34, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24055443

RESUMO

OBJECTIVES: This first-in-human multicenter study sought to examine prospectively the safety and efficacy of a new, cobalt chromium thin-strut, coronary absorbable polymer-coated, sirolimus-eluting stent. BACKGROUND: Bioabsorbable polymers on drug-eluting stents may lower the long-term risks of inflammation, delayed healing, and adverse events. METHODS: We enrolled patients with symptomatic coronary artery disease with stable or unstable angina pectoris and >50% diameter stenosis, amenable to coverage with a ≤23-mm long stent in a vessel 2.5 to 3.5 mm in diameter. All patients received dual antiplatelet therapy after implantation. Patients, in groups of 10, underwent repeat angiography, intravascular ultrasound, and optical coherence tomography at 4, 6, or 8 months, and all patients were seen or contacted at 18 months of follow-up. RESULTS: The median (range) in-stent late lumen loss (LLL) was 0.03 mm (-0.22 to 0.21 mm), 0.10 mm (-0.03 to 1.2 mm), and 0.08 mm (-0.01 to 0.28 mm), at 4, 6, and 8 months, respectively. At 18 months, the median in-stent LLL was 0.08 mm (-0.30 to 0.46 mm). On optical coherence tomography, the proportion of uncovered stent struts decreased from a median of 7.3% (range 0.4% to 46.3%) at 4 months to 0% (range: 0% to 3.4%) at 18 months. The percentage of neointimal volume obstruction by intravascular ultrasound increased from a median of 5.3% to 9.1% between 4 and 6 months and remained nearly unchanged thereafter through 18 months of follow-up. The only recorded major adverse cardiac event was a myocardial infarction. CONCLUSIONS: At 18 months of follow-up, this absorbable polymer-coated, cobalt chromium sirolimus-eluting stent was associated with a low and stable in-stent LLL, complete strut coverage, and no stent thrombosis. (First-In-Human Trial of the MiStent Drug-Eluting Stent [DES] in Coronary Artery Disease [DESSOLVE-I]; NCT01247428).


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros , Sirolimo/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Angina Estável/diagnóstico , Angina Estável/terapia , Angina Instável/diagnóstico , Angina Instável/terapia , Austrália , Bélgica , Ligas de Cromo , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Reestenose Coronária/etiologia , Estenose Coronária/diagnóstico , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/patologia , Quimioterapia Combinada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Neointima , Nova Zelândia , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Estudos Prospectivos , Desenho de Prótese , Índice de Gravidade de Doença , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção
11.
J Am Coll Cardiol ; 59(15): 1371-6, 2012 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-22284328

RESUMO

OBJECTIVES: This study sought to demonstrate the noninferiority of polymer-free amphilimus-eluting stents (Cre8, CID, Saluggia, Italy) versus permanent-polymer paclitaxel-eluting stents (Taxus Liberté, Boston Scientific, Natick, Massachusetts) in de novo percutaneous coronary intervention. BACKGROUND: Although the efficacy of the drug-eluting stent has been well established, the risk-benefit balance is still suboptimal, and the safety of polymers remains uncertain. METHODS: Patients undergoing percutaneous coronary intervention for de novo lesions were randomly assigned 1:1 to Cre8 or Taxus Liberté stents. Primary endpoint was 6-month angiographic in-stent late lumen loss (LLL) within a noninferiority scope. Six-month intravascular ultrasound was performed in 20% of the patients. All patients will be clinically followed up to 5 years. RESULTS: Out of 323 patients enrolled, 162 received Cre8 and 161 Taxus Liberté stents. In-stent LLL was significantly lower in Cre8 group (0.14 ± 0.36 mm vs. 0.34 ± 0.40 mm, p noninferiority <0.0001, p superiority <0.0001). Clinical endpoints (cardiac death, myocardial infarction, target lesion revascularization, and stent thrombosis) up to 12 months did not differ significantly between the groups. CONCLUSIONS: The Cre8 stent in de novo lesions showed significantly lower in-stent LLL at 6 months than the Taxus Liberté stent did, with a trend toward better 12-month clinical safety and efficacy results. (International Randomized Comparison Between DES Limus Carbostent and Taxus Drug-Eluting Stents in the Treatment of De Novo Coronary Lesions [NEXT]; NCT01373502).


Assuntos
Angioplastia Coronária com Balão/métodos , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Paclitaxel/farmacologia , Antineoplásicos Fitogênicos/farmacologia , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Método Simples-Cego , Resultado do Tratamento , Ultrassonografia de Intervenção
12.
EuroIntervention ; 7 Suppl K: K100-5, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-22027717

RESUMO

BACKGROUND: The optimal treatment of bare metal stent restenosis is still not defined. The most employed contemporary option is the implantation of a drug-eluting stent (DES). However, this procedure implies the addition of a second metal layer in the vessel wall, which is linked to delayed healing. Furthermore, there may be a increased risk of malapposition of both struts of the bare metal and the newly implanted drug-eluting stent. These phenomena may give rise to an increased risk of stent thrombosis in this patient population. Recently, drug-eluting balloons (DEB) have been proposed as a new treatment strategy for bare metal stent restenosis. The initial results of this technique look promising. OBJECTIVES: To compare healing processes after treatment of bare metal stent (BMS) in-stent restenosis (ISR) with balloon dilatation using DEB versus implantation of DES. STUDY DESIGN: This is a prospective, multicentre (University Hospitals Leuven and ZOL Hospital Genk, Belgium) randomised clinical trial with clinical, angiographic and OCT follow-up at nine months. Patients with bare metal stent restenosis and an indication for repeat PCI are randomised to treatment with a paclitaxel-eluting balloon (SeQuent Please, B-Braun, Melsungen, Germany) versus a Xience V/ Xience Prime everolimus-eluting stent (Abbott Vascular, Santa Clara, CA, USA). The primary objective of this study is to evaluate the vascular healing response of the vessel wall after balloon angioplasty with a paclitaxel-eluting balloon versus implantation of a drug-eluting stent in patients with in-stent restenosis in a coronary artery. The primary endpoint of the study is stent strut coverage and stent strut apposition at nine months, as assessed with OCT. CONCLUSIONS: Currently no prospectively collected data on vessel wall healing after treatment of in-stent restenosis, whether with DES or with DEB, are available. Therefore, the SEDUCE trial will yield pivotal insights on this important topic and guide further optimisation of the interventional treatment for this condition.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Reestenose Coronária/terapia , Sistemas de Liberação de Medicamentos/instrumentação , Paclitaxel/administração & dosagem , Projetos de Pesquisa , Stents , Tomografia de Coerência Óptica , Angioplastia Coronária com Balão/efeitos adversos , Bélgica , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/patologia , Stents Farmacológicos , Desenho de Equipamento , Everolimo , Humanos , Metais , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA