JACC Cardiovasc Interv ; 10(1): 42-49, 2017 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-28017311

RESUMO

OBJECTIVES: The study sought to evaluate the efficacy and safety of the Absorb everolimus-eluting bioresorbable vascular scaffold (BVS) (Abbott Vascular, Abbott Park, Illinois) in patients with diabetes mellitus. BACKGROUND: Randomized, controlled trials have demonstrated comparable clinical outcomes following percutaneous coronary intervention with either Absorb BVS or metallic Xience everolimus-eluting stent. However, these trials lack power required to provide reliable treatment effect estimates in this high-risk population. METHODS: In a pre-specified, powered analysis, patients with diabetes who received ≥1 Absorb were pooled from the ABSORB II, III, and JAPAN randomized trials and from the single arm ABSORB EXTEND registry. The study composite primary endpoint was target lesion failure (TLF) at 1 year following Absorb BVS compared with a performance goal of 12.7%. RESULTS: Among 754 diabetic patients included in analysis (27.3% insulin treated), the 1-year TLF rate was 8.3% (upper 1-sided 95% confidence limit: 10.1%; p = 0.0001 vs. performance goal). Scaffold thrombosis (definite or probable) was observed in 2.3% of patients. Multivariable regression identified older age, insulin treatment, and smaller pre-procedure reference vessel diameter as significant independent predictors of 1-year TLF. CONCLUSIONS: The Absorb diabetic substudy suggests efficacy and safety of the Absorb BVS for treatment of patients with diabetes mellitus.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Diabetes Mellitus , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Fatores Etários , Idoso , Fármacos Cardiovasculares/efeitos adversos , Distribuição de Qui-Quadrado , Doença da Artéria Coronariana/diagnóstico por imagem , Trombose Coronária/etiologia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/tratamento farmacológico , Everolimo/efeitos adversos , Feminino , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Intervenção Coronária Percutânea/efeitos adversos , Modelos de Riscos Proporcionais , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
JACC Cardiovasc Interv ; 10(18): 1881-1890, 2017 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-28935081

RESUMO

OBJECTIVES: Because females are under-represented in coronary trials, this study sought to assess the relative safety and efficacy of Absorb bioresorbable vascular scaffold (BVS) (Abbott Vascular, Santa Clara, California) and the Xience everolimus-eluting stent in females compared with males. BACKGROUND: The Absorb everolimus-eluting BVS provides drug delivery and mechanical support similar to a metallic drug-eluting stent, followed by resorption and restoration of more normal vascular structure with the potential to improve late clinical outcomes. METHODS: The ABSORB II, ABSORB III, ABSORB Japan, and ABSORB China trials were pooled. Baseline clinical, angiography, procedural variables, and 2-year outcomes were analyzed by sex and device. RESULTS: Among 3,384 randomized patients, 932 (27.5%) were female. Females were older, more often had diabetes and hypertension, but had less everolimus-eluting stent, 3-vessel disease, and smoking compared with males (all p≤0.001). The 2-year rates of target lesion failure with BVS versus everolimus-eluting stent in females were 8.9% versus 6.2% (study-level adjusted hazard ratio: 1.47; 95% confidence interval [CI]: 0.88 to 2.46) and 8.9% versus 6.4% in males (HR: 1.40; 95% CI: 1.02 to 1.92; pinteraction = 0.85). There were no significant interactions between sex and device type for any of the components of target lesion failure. CONCLUSIONS: The relative treatment effects of BVS and everolimus-eluting stent for the 2-year rates of target lesion failure and other cardiovascular outcomes were consistent in females and males.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Idoso , Fármacos Cardiovasculares/efeitos adversos , Distribuição de Qui-Quadrado , Angiografia Coronária , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Intervenção Coronária Percutânea/efeitos adversos , Modelos de Riscos Proporcionais , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Resultado do Tratamento