Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Dent Sci ; 19(2): 878-884, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38618079

RESUMO

Background/purpose: The possibility of triggering the trigeminocardiac reflex (TCR) during oral surgery is considerably lower than that during other surgeries. A reduced heart rate (HR) of ≥20% from baseline is usually considered a diagnostical criterion for the TCR. Our automated anesthesia charting system often revealed cases of slight transient HR decrease during sedation. We aimed to explore its incidence and associated factors during local anesthesia administration under intravenous sedation. Materials and methods: This study analyzed the data of 2636 cases that received infiltration anesthesia under intravenous sedation from 2008 to 2010 and had vital signs recorded using an automated anesthesia charting system. Especially, data concerning the average HR before anesthesia and the minimum HR between the initiation and end of anesthesia from anesthetic records were extracted. Moreover, data regarding patients' medical history and unusual reactions during dental treatment were collected. Multivariate logistic regression analysis was performed to identify factors associated with transient bradycardia (TB). Results: TB occurred in 472 patients (17.9%); no patient developed hypotension or any associated symptoms, suggesting that intravenous sedation was effective in stabilizing vital signs. The factors associated with TB were younger age, gag reflex, and allergy to local anesthetics. There were no differences in sex, patient history, or dose of sedatives between patients with TB and those without TB. Conclusion: The incidence of TB during infiltration anesthesia under sedation was found to be higher than that previously reported. Additionally, young age and gag reflex were identified as factors associated with bradycardia development.

2.
Spec Care Dentist ; 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38698537

RESUMO

AIMS: Potocki-Lupski syndrome (PTLS), which is caused by the partial duplication of the short arm of autosome 17, is characterized by feeding difficulties associated with muscle hypotonia and dysphagia in infancy, followed by growth retardation and low body weight in later stages. Speech and motor developmental disorders are observed in childhood, accompanied by autism spectrum disorders in several cases. Other disorders include dental and skeletal abnormalities, and associated sleep apnea. Herein, we describe the first case of dental evaluation and treatment under intravenous sedation in a patient with PTLS. METHODS: A 13-year-old boy with PTLS and intellectual disability was referred for the treatment of dental caries. Routine intraoral examination and dental treatment were not feasible. As the patient had no muscle hypotonia, dysphagia, or severe growth delay, intraoral examination and dental treatment were successfully performed under intravenous sedation. No incidence of intraoral airway obstruction or aspiration was reported. The patient was followed-up post-operatively. CONCLUSION: PTLS, a newly identified syndrome, is associated with cardiovascular abnormalities, dysphagia, failure to thrive, and sleep apnea, which are potential risk factors for sedation. This case report highlights the importance of facial and oral findings in determining the risks of difficulties in airway management.

3.
Anesth Prog ; 70(1): 25-30, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36995959

RESUMO

Sudden cardiac arrest (SCA) is an uncommon event in dental practice; however, the frequency of dentists encountering SCA and other major medical emergencies is increasing. We report the successful resuscitation of a patient who developed SCA while awaiting examination and treatment at a dental hospital. The emergency response team was called upon, and cardiopulmonary resuscitation/basic life support (CPR/BLS), including chest compression and mask ventilation, was promptly initiated. An automated external defibrillator was used, which indicated that the patient's cardiac rhythm was unsuitable for electrical defibrillation. The patient returned to spontaneous circulation after 3 cycles of CPR and intravenous epinephrine. The knowledge and skill levels of dentists regarding resuscitation under emergency circumstances should be addressed. Emergency response systems must be well established, and CPR/BLS knowledge and training should be updated regularly, including optimal management of both shockable and nonshockable rhythms.


Assuntos
Reanimação Cardiopulmonar , Serviços Médicos de Emergência , Parada Cardíaca , Humanos , Parada Cardíaca/diagnóstico , Parada Cardíaca/etiologia , Parada Cardíaca/terapia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores
4.
J Pers Med ; 13(3)2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36983643

RESUMO

Implant surgery is a lengthy dental procedure, and sedation is often used to reduce discomfort. The effectiveness of sedation has traditionally been evaluated in terms of patient and surgeon satisfaction, but the most important goal is not to induce a deep sleep in the patient, but rather to ensure that the surgery is performed safely and as planned. Additionally, adequate pain control is a necessary requirement for patient and surgeon satisfaction. Most patients undergoing implant surgery are middle-aged or older, and a relatively large number of them have cardiovascular disease. Infiltration anesthesia using articaine or lidocaine in combination with adrenaline is widely used, but its use in patients with cardiovascular disease is limited because of adrenaline's effects on the cardiovascular system. The use of long-acting local anesthetics and the potential efficacy of ultrasound-guided jaw nerve block have been investigated to enhance analgesia without resorting to adrenaline. Midazolam and propofol are usually used for sedation, but dexmedetomidine, which causes less respiratory depression, and the ultrashort-acting benzodiazepine remimazolam are emerging as potential alternatives. Monitoring of anesthetic depth using electroencephalography is effective in maintaining a constant level of sedation. In addition, sedation promotes the stabilization of heart rate and blood pressure, reducing the risks associated with adrenaline and allowing for safer management.

5.
Anesth Prog ; 59(2): 62-8, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22822992

RESUMO

Dexmedetomidine (DEX) has a minimal respiratory depressive effect, which is beneficial for dentistry; however, it has the disadvantage of permitting an intraoperative arousal response such that the patient appears to be suddenly no longer sedated, and it has a variable amnestic effect. Since midazolam (MDZ) in an appropriate dose has a profound amnesic effect, we investigated whether additional MDZ compensates for the disadvantage of DEX and enables a better quality of sedation. Forty-three subjects were randomly divided into 4 groups. In group 1, MDZ (0.02 mg/kg) was administered intravenously, followed by a dose of 0.01 mg/kg every 45 minutes. After the first dose of MDZ, preloading with DEX (2 µg/kg/h for 10 minutes) was started and maintained with a dosage of 0.5 µg/kg/h. In group 2, MDZ was infused in the same manner as in group 1, followed by preloading with DEX (1 µg/kg/h for 10 minutes) and maintenance (0.3 µg/kg/h). In group 3, MDZ was infused 0.03 mg/kg, and a dose of 0.01 mg/kg was given every 30 minutes; DEX was administered at the same as in group 2. In group 4, DEX was infused using the same method as in group 1 without MDZ. The sedation levels, amnesia, and patient satisfaction were also investigated. Group 2 had a lower sedation level and a poor evaluation during the first half of the operation. Group 4 did not exhibit an amnesic effect at the beginning of the operation. An evaluation of the degree of patient satisfaction did not reveal any differences among the groups. Optimal sedation was achieved through the combined use of MDZ (0.02 mg/kg with the addition of 0.01 mg/kg every 45 minutes) and DEX (2 µg/kg/h for 10 minutes followed by 0.5 µg/kg/h).


Assuntos
Anestesia Dentária/métodos , Anestésicos Combinados/administração & dosagem , Sedação Consciente/métodos , Dexmedetomidina/administração & dosagem , Hipnóticos e Sedativos/administração & dosagem , Midazolam/administração & dosagem , Adulto , Idoso , Amnésia/induzido quimicamente , Análise de Variância , Anestesia Intravenosa/métodos , Implantação Dentária Endóssea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Estatísticas não Paramétricas , Adulto Jovem
6.
J Clin Med ; 11(14)2022 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-35887725

RESUMO

Pulse wave transit time (PWTT) is the time difference between the occurrence of an R-wave on an electrocardiogram and the detection of pulsatile signals on a pulse oximeter, which reflects changes in blood pressure (BP) corresponding to the vessel wall compliance. However, the factors affecting PWTT variability have not been determined. Thus, we investigated the BP changes associated with variations in PWTT and identified the clinical characteristics associated with these variations. Data related to 605 cases of dental procedures performed under intravenous conscious sedation from April 2020 to November 2021 were collected, and 485 cases were enrolled. Heart rate, systolic blood pressure before and after local anesthesia (LA) administration, and crest and trough PWTT waves during LA administration were recorded. Thereafter, PWTT variability was calculated; cases were divided into two groups: large PWTT variability (LPV, n = 357) and small PWTT variability (SPV, n = 128). The index of large PWTT variability could not detect changes in BP. Logistic regression analysis revealed that factors, such as LA use, age, hypertension, and dental treatment phobia were associated with PWTT variability. The use of epinephrine more than 36.25 µg in each LA resulted in PWTT variability of more than 15 ms.

7.
J Mater Chem B ; 7(44): 7026-7032, 2019 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-31638628

RESUMO

Lidocaine has been used as a local anesthetic by injection. The controlled release of lidocaine loaded into nanospheres is necessary to reduce the onset time of the anesthetic effect or increase the anesthetic analgesia duration. In this study, mesoporous silica nanoparticles (MSNs) with a large specific surface area were prepared by a sol-gel method, and the interfacial interaction between MSNs and lidocaine positively charged in aqueous solutions at different concentrations was investigated by adsorption tests, Fourier-transformed infrared spectroscopy, thermogravimetry-differential thermal analysis, and Brunauer-Emmett-Teller (BET) measurements. The electrostatic interaction between Si-OH on MSNs and lidocaine-NH+ was of importance for the adsorption phenomenon in aqueous solutions, indicating the monolayer adsorption of lidocaine. BET measurements also supported the decrease of pore volumes, and the hysteresis loop of the isotherm curve was not closed since the condensation of lidocaine in the mesopores formed micropores of less than 1.5 nm in size. The release profiles in phosphate buffered saline containing calcium and magnesium ions showed a rapid and higher release of lidocaine compared with that in phosphate buffered saline without divalent cations. The released lidocaine concentrations were sufficient for the expression of the anesthetic effect in dental anesthesia.


Assuntos
Anestésicos Locais/química , Lidocaína/química , Nanopartículas/química , Dióxido de Silício/química , Adsorção , Liberação Controlada de Fármacos
8.
J Clin Anesth ; 20(2): 146-9, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18410873

RESUMO

Patients with intermittent Wolff-Parkinson-White (WPW) syndrome, defined as intermittent loss of the delta waves, can show occasional conduction through the accessory pathway. WPW syndrome often causes paroxysmal supraventricular tachycardia or atrial fibrillation. However, it may be difficult to identify the abnormalities preoperatively because of their only intermittent occurrence. We report a case in which exogenously administered epinephrine and an autonomic imbalance may have precipitated the abrupt occurrence and disappearance of the delta waves.


Assuntos
Anestésicos Intravenosos , Sedação Consciente/efeitos adversos , Propofol , Síndrome de Wolff-Parkinson-White/fisiopatologia , Eletrocardiografia , Epinefrina/farmacologia , Feminino , Humanos , Hiperventilação/fisiopatologia , Pessoa de Meia-Idade , Dente Molar/cirurgia , Resultado do Tratamento
9.
J Med Dent Sci ; 63(4): 71-77, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28049939

RESUMO

The present study investigates how effectively lidocaine ions are transported across a cellophane membrane through the application of either a direct current (DC) or alternating current (AC). The cellophane membrane was set on a parallelplate- type acrylic cell with platinum electrodes at both ends, filled with a donor cell of a 1 % aqueous solution of lidocaine and a receptor cell with distilled water. Lidocaine concentrations were measured for 60 min while the following voltages were applied, with changes every 10 min: 3 V DC and 7.5 V sine wave AC; frequency at 1 kHz. As a result, lidocaine concentrations in the receptor cell increased in a time-dependent manner. Significant increases in lidocaine concentrations were observed in groups where the voltage combination consisted of DC 30 min/AC 30 min, DC 50 min/AC 10 min, DC 60 min and AC 10 min/DC 50 min, compared with the passive diffusion group or in groups where voltage application was performed for 20, 30 , 40, 50 and 60 min. Significant increases were also observed in groups where the voltage combination consisted of A C 6 0 min, D C 10 min/AC 5 0 min, AC 3 0 min/ DC 30 min and AC 50 min/DC 10 min, compared with the passive diffusion group or in groups where voltage application was performed for 40, 50 and 60 min. These results suggest that lidocaine was delivered more rapidly with DC than with AC, and that its ions are transported faster when voltage is switched from DC to AC than from AC to DC, which is presumably due to the contribution of electrorepulsion by DC voltage application and the vibration energy infiltration mechanism owning to AC. Iontophoresis in combination with DC and AC was found to enable highly efficient drug delivery that shares the benefits of both forms of current application.


Assuntos
Anestésicos Locais/administração & dosagem , Sistemas de Liberação de Medicamentos/métodos , Iontoforese/métodos , Lidocaína/administração & dosagem , Anestésicos Locais/química , Celofane/química , Eletricidade , Lidocaína/química , Membranas/química , Membranas Artificiais , Temperatura , Água/química
10.
J Med Dent Sci ; 61(2): 41-8, 2014 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-25952356

RESUMO

Iontophoresis (IOP) is a noninvasive method of delivering medication transcutaneously through the skin. The electrodes used in this method should tightly fit to rough and irregular surfaces and be biologically safe, easy to handle and prepare, and cost-effective. To satisfy these requirements, calcium alginate gel can be a candidate electrode for IOP. Using calcium alginate gel electrodes, we examined whether lidocaine can be effectively transported across an excised rat skin by squarewave alternating current (AC) application. A squarewave AC with either a 70% or 80% duty cycle was continuously applied to 0.5% calcium alginate gel electrodes containing 10% lidocaine at 10 V and 1 kHz for 60 min. Lidocaine concentration was measured using a spectrophotometer and the temperature of the gel was determined. The lidocaine concentrations for AC-IOP at the 70% and 80% duty cycles were significantly higher than that without AC-IOP. Furthermore, the group with the 80% duty cycle showed higher lidocaine concentrations than the group with the 70% duty cycle. The temperatures of all the groups were lower than 28 °C throughout the procedure. In conclusion, the calcium alginate gel can be used as a possible matrix for IOP electrodes.


Assuntos
Alginatos/química , Anestésicos Locais/administração & dosagem , Materiais Biocompatíveis/química , Eletrodos , Iontoforese/instrumentação , Lidocaína/administração & dosagem , Animais , Difusão , Sistemas de Liberação de Medicamentos , Desenho de Equipamento , Géis , Ácido Glucurônico/química , Ácidos Hexurônicos/química , Técnicas In Vitro , Iontoforese/métodos , Masculino , Teste de Materiais , Ratos , Ratos Wistar , Absorção Cutânea/efeitos dos fármacos , Espectrofotometria/métodos , Temperatura , Fatores de Tempo
11.
J Med Dent Sci ; 60(3): 63-71, 2013 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-24146168

RESUMO

The aim of this study was to determine transport of lidocaine ions through a hairless rat skin in vivo and to compare the efficacy of alternating current (AC) with that of direct current (DC) iontophoresis (IOP). We measured the concentration of lidocaine transported through a cellophane membrane or a hairless rat dorsal skin applying either AC-IOP or DC-IOP. The results revealed that lidocaine concentration increased in a time-dependent manner in vitro in both DC-IOP and AC-IOP. However, the in vivo study showed different tendencies in lidocaine concentration. In the DCIOP group, lidocaine concentration reached its maximum 20 min after current application and then decreased rapidly; the AC-IOP group showed an increase in lidocaine concentration in a time-dependent manner. There were no side effects such as electrical burns in the rats. In conclusion, AC can be applied for long periods and DC for short periods, or their application time can be appropriately scheduled. Our study also suggests the mechanism by which voltage waveforms affect the skin when applied by IOP. In the future, these findings will be a solid foundation for developing various kinds of medical equipment such as scheduled drug delivery system that can easily deliver various types of drug.


Assuntos
Anestésicos Locais/administração & dosagem , Iontoforese/métodos , Lidocaína/administração & dosagem , Administração Cutânea , Anestésicos Locais/química , Animais , Celofane/química , Eletricidade , Lidocaína/química , Masculino , Membranas Artificiais , Microdiálise/métodos , Ratos , Ratos Pelados , Absorção Cutânea , Fatores de Tempo
12.
Artigo em Inglês | MEDLINE | ID: mdl-17138162

RESUMO

Two cases of vasovagal syncope (VVS) during venous access are reported. Both patients had a history of fainting episodes and experienced bradycardia with asystole, hypotension, and fainting. Pain and phobic stress during venous access triggered an increase in parasympathetic tone, resulting in bradycardia with asystole and hypotension in both cases. Hypotension and bradycardia likely caused cerebral hypoperfusion, leading to fainting. The intense parasympathetic tone triggered by somatic or emotional stress was likely responsible for directly depressing the sinus node, leading to asystole and bradycardia. Bradycardia with asystole progressing to syncope is a potentially fatal dysrhythmia in patients with cardiovascular disease or older patients with decreased cardiac function. Appropriate treatment for VVS includes the administration of intravenous fluids, vagolytics, ephedrine, and the rapid use of the Trendelenburg position. Intravenous fluids and atropine were used to treat the present patients.


Assuntos
Anestesia Dentária/efeitos adversos , Parada Cardíaca/etiologia , Procedimentos Cirúrgicos Bucais/efeitos adversos , Flebotomia/efeitos adversos , Síncope Vasovagal/etiologia , Adulto , Anestesia Dentária/métodos , Atropina/uso terapêutico , Bradicardia/etiologia , Sedação Consciente/efeitos adversos , Ansiedade ao Tratamento Odontológico/complicações , Humanos , Masculino , Parassimpatolíticos/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA