Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Int J Mol Sci ; 22(2)2021 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-33478090

RESUMO

Magnesium (Mg)-based biomaterials hold considerable promise for applications in regenerative medicine. However, the degradation of Mg needs to be reduced to control toxicity caused by its rapid natural corrosion. In the process of developing new Mg alloys with various surface modifications, an efficient assessment of the relevant properties is essential. In the present study, a WE43 Mg alloy with a plasma electrolytic oxidation (PEO)-generated surface was investigated. Surface microstructure, hydrogen gas evolution in immersion tests and cytocompatibility were assessed. In addition, a novel in vitro immunological test using primary human lymphocytes was introduced. On PEO-treated WE43, a larger number of pores and microcracks, as well as increased roughness, were observed compared to untreated WE43. Hydrogen gas evolution after two weeks was reduced by 40.7% through PEO treatment, indicating a significantly reduced corrosion rate. In contrast to untreated WE43, PEO-treated WE43 exhibited excellent cytocompatibility. After incubation for three days, untreated WE43 killed over 90% of lymphocytes while more than 80% of the cells were still vital after incubation with the PEO-treated WE43. PEO-treated WE43 slightly stimulated the activation, proliferation and toxin (perforin and granzyme B) expression of CD8+ T cells. This study demonstrates that the combined assessment of corrosion, cytocompatibility and immunological effects on primary human lymphocytes provide a comprehensive and effective procedure for characterizing Mg variants with tailorable degradation and other features. PEO-treated WE43 is a promising candidate for further development as a degradable biomaterial.


Assuntos
Materiais Revestidos Biocompatíveis , Magnésio/química , Teste de Materiais , Animais , Células Cultivadas , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacocinética , Materiais Revestidos Biocompatíveis/farmacologia , Corrosão , Equipamentos e Provisões , Humanos , Sistema Imunitário/efeitos dos fármacos , Linfócitos/efeitos dos fármacos , Linfócitos/fisiologia , Magnésio/farmacocinética , Magnésio/farmacologia , Compostos de Magnésio/química , Compostos de Magnésio/farmacocinética , Compostos de Magnésio/farmacologia , Teste de Materiais/métodos , Camundongos , Oxirredução
2.
Int J Mol Sci ; 21(9)2020 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-32353983

RESUMO

INTRODUCTION: Bioresorbable collagenous barrier membranes are used to prevent premature soft tissue ingrowth and to allow bone regeneration. For volume stable indications, only non-absorbable synthetic materials are available. This study investigates a new bioresorbable hydrofluoric acid (HF)-treated magnesium (Mg) mesh in a native collagen membrane for volume stable situations. MATERIALS AND METHODS: HF-treated and untreated Mg were compared in direct and indirect cytocompatibility assays. In vivo, 18 New Zealand White Rabbits received each four 8 mm calvarial defects and were divided into four groups: (a) HF-treated Mg mesh/collagen membrane, (b) untreated Mg mesh/collagen membrane (c) collagen membrane and (d) sham operation. After 6, 12 and 18 weeks, Mg degradation and bone regeneration was measured using radiological and histological methods. RESULTS: In vitro, HF-treated Mg showed higher cytocompatibility. Histopathologically, HF-Mg prevented gas cavities and was degraded by mononuclear cells via phagocytosis up to 12 weeks. Untreated Mg showed partially significant more gas cavities and a fibrous tissue reaction. Bone regeneration was not significantly different between all groups. DISCUSSION AND CONCLUSIONS: HF-Mg meshes embedded in native collagen membranes represent a volume stable and biocompatible alternative to the non-absorbable synthetic materials. HF-Mg shows less corrosion and is degraded by phagocytosis. However, the application of membranes did not result in higher bone regeneration.


Assuntos
Materiais Biocompatíveis/farmacologia , Regeneração Óssea/efeitos dos fármacos , Magnésio/química , Crânio/lesões , Células 3T3 , Implantes Absorvíveis , Animais , Materiais Biocompatíveis/química , Linhagem Celular , Modelos Animais de Doenças , Feminino , Regeneração Tecidual Guiada , Ácido Fluorídrico/química , Membranas Artificiais , Camundongos , Fagocitose , Coelhos , Crânio/efeitos dos fármacos , Resultado do Tratamento
3.
Int J Mol Sci ; 20(19)2019 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-31574947

RESUMO

The degradation rate of magnesium (Mg) alloys is a key parameter to develop Mg-based biomaterials and ensure in vivo-mechanical stability as well as to minimize hydrogen gas production, which otherwise can lead to adverse effects in clinical applications. However, in vitro and in vivo results of the same material often differ largely. In the present study, a dynamic test bench with several single bioreactor cells was constructed to measure the volume of hydrogen gas which evolves during magnesium degradation to indicate the degradation rate in vivo. Degradation medium comparable with human blood plasma was used to simulate body fluids. The media was pumped through the different bioreactor cells under a constant flow rate and 37 °C to simulate physiological conditions. A total of three different Mg groups were successively tested: Mg WE43, and two different WE43 plasma electrolytically oxidized (PEO) variants. The results were compared with other methods to detect magnesium degradation (pH, potentiodynamic polarization (PDP), cytocompatibility, SEM (scanning electron microscopy)). The non-ceramized specimens showed the highest degradation rates and vast standard deviations. In contrast, the two PEO samples demonstrated reduced degradation rates with diminished standard deviation. The pH values showed above-average constant levels between 7.4-7.7, likely due to the constant exchange of the fluids. SEM revealed severe cracks on the surface of WE43 after degradation, whereas the ceramized surfaces showed significantly decreased signs of corrosion. PDP results confirmed the improved corrosion resistance of both PEO samples. While WE43 showed slight toxicity in vitro, satisfactory cytocompatibility was achieved for the PEO test samples. In summary, the dynamic test bench constructed in this study enables reliable and simple measurement of Mg degradation to simulate the in vivo environment. Furthermore, PEO treatment of magnesium is a promising method to adjust magnesium degradation.


Assuntos
Materiais Biocompatíveis/química , Hidrodinâmica , Magnésio/química , Reatores Biológicos , Materiais Revestidos Biocompatíveis , Humanos , Concentração de Íons de Hidrogênio , Teste de Materiais , Microscopia Eletrônica de Varredura
4.
Int J Mol Sci ; 20(2)2019 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-30634646

RESUMO

Magnesium (Mg)-based biomaterials are promising candidates for bone and tissue regeneration. Alloying and surface modifications provide effective strategies for optimizing and tailoring their degradation kinetics. Nevertheless, biocompatibility analyses of Mg-based materials are challenging due to its special degradation mechanism with continuous hydrogen release. In this context, the hydrogen release and the related (micro-) milieu conditions pretend to strictly follow in vitro standards based on ISO 10993-5/-12. Thus, special adaptions for the testing of Mg materials are necessary, which have been described in a previous study from our group. Based on these adaptions, further developments of a test procedure allowing rapid and effective in vitro cytocompatibility analyses of Mg-based materials based on ISO 10993-5/-12 are necessary. The following study introduces a new two-step test scheme for rapid and effective testing of Mg. Specimens with different surface characteristics were produced by means of plasma electrolytic oxidation (PEO) using silicate-based and phosphate-based electrolytes. The test samples were evaluated for corrosion behavior, cytocompatibility and their mechanical and osteogenic properties. Thereby, two PEO ceramics could be identified for further in vivo evaluations.


Assuntos
Materiais Biocompatíveis/química , Compostos de Magnésio/química , Materiais Biocompatíveis/farmacologia , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Corrosão , Humanos , Concentração de Íons de Hidrogênio , Magnésio/química , Compostos de Magnésio/farmacologia , Teste de Materiais , Fenômenos Mecânicos , Concentração Osmolar , Osteogênese/efeitos dos fármacos , Oxirredução
5.
J Biomed Mater Res B Appl Biomater ; 110(4): 898-909, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34846806

RESUMO

Implants of different material classes have been used for the reconstruction of damaged hard and soft tissue for decades. The aim is to increase and subsequently maintain the patient's quality of life through implantation. In service, most implants are subjected to cyclic loading, which must be taken particularly into consideration, since the fatigue strength is far below the yield and tensile strength. Inaccurate estimation of the structural strength of implants due to the consideration of yield or tensile strength leads to a miscalculation of the implant's fatigue strength and lifetime, and therefore, to its unexpected early fatigue failure. Thus, fatigue failure of an implant based on overestimated performance capability represents acute danger to human health. The determination of fatigue strength by corresponding tests investigating various stress amplitudes is time-consuming and cost-intensive. This study summarizes four investigation series on the fatigue behavior of different implant materials and components, following a standard and an in vitro short-time testing procedure, which evaluates the material reaction in one enhanced test set-up. The test set-up and the applied characterization methods were adapted to the respective application of the implant with the aim to simulate the surrounding of the human body with laboratory in vitro tests only. It could be shown that by using the short-time testing method the number of tests required to determine the fatigue strength can be drastically reduced. In future, therefore it will be possible to exclude unsuitable implant materials or components before further clinical investigations by using a time-efficient and application-oriented testing method.


Assuntos
Implantes Dentários , Qualidade de Vida , Análise do Estresse Dentário , Humanos , Técnicas In Vitro , Teste de Materiais , Estresse Mecânico , Resistência à Tração , Titânio
6.
Tissue Eng Part A ; 27(19-20): 1239-1249, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33397206

RESUMO

In this study, microvascular network structures for tissue engineering were generated on newly developed macroporous polydioxanone (PDO) scaffolds. PDO represents a polymer biodegradable within months and offers optimal material properties such as elasticity and nontoxic degradation products. PDO scaffolds prepared by porogen leaching and cryo-dried to achieve pore sizes of 326 ± 149.67 µm remained stable with equivalent values for Young's modulus after 4 weeks. Scaffolds were coated with fibrin for optimal cell adherence. To exclude interindividual differences, autologous fibrin was prepared out of human plasma-derived fibrinogen and proved a comparable quality to nonautologous commercially available fibrinogen. Fibrin-coated scaffolds were seeded with recombinant human umbilical vein endothelial cells expressing GFP (GFP-HUVECs) in coculture with adipose tissue-derived mesenchymal stem cells (AD-hMSCs) to form vascular networks. The growth factor content in culture media was optimized according its effect on network formation, quantified and assessed by AngioTool®. A ratio of 2:3 GFP-HUVECs/AD-hMSCs in medium enriched with 20 ng/mL vascular endothelial growth factor, basic fibroblast growth factor, and hydrocortisone was found to be optimal. Network structures appeared after 2 days of cultivation and stabilized until day 7. The resulting networks were lumenized that could be verified by dextran staining. This new approach might be suitable for microvascular tissue patches as a useful template to be used in diverse vascularized tissue constructs. Impact statement We consider this work as important for the current research in the field of tissue engineering and the development of new and functional tissue. The approach for the production of vascularized tissue patches, consisting of the biodegradable synthetic polymer polydioxanone and of the physiological, autologous, and patient-specific polymer fibrin, and seeded with endothelial cells and mesenchymal stem cells, displayed within this work, could be useful for the sustaining development of diverse and more complex tissue constructs. Therefore, these scaffolds could be used as a cornerstone for future tissue engineering approaches.


Assuntos
Polidioxanona , Alicerces Teciduais , Tecido Adiposo/citologia , Células Endoteliais , Fibrina , Fator 2 de Crescimento de Fibroblastos , Células Endoteliais da Veia Umbilical Humana , Humanos , Hidrocortisona , Células-Tronco Mesenquimais , Engenharia Tecidual , Fator A de Crescimento do Endotélio Vascular
7.
Mater Sci Eng C Mater Biol Appl ; 111: 110750, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32279822

RESUMO

A promising direction for the replacement of expanded bone defects is the development of bioimplants based on synthetic biocompatible materials impregnated with growth factors that stimulate bone remodeling. Novel biomimetic highly porous ultra-high molecular weight polyethylene (UHMWPE)/40% hydroxyapatite (HA) scaffold for reconstructive surgery with the porosity of 85 ± 1% vol. and a diameter of pores in the range of 50-800 µm was developed. The manufacturing process allowed the formation of trabecular-like architecture without additional solvents and thermo-oxidative degradation. Biomimetic UHMWPE/HA scaffold was biocompatible and provided effective tissue ingrowth on a model of critical-sized cranial defects in mice. The combined use of UHMWPE/HA with Bone Morphogenetic Protein-2 (BMP-2) demonstrated intensive mineralized bone formation as early as 3 weeks after surgery. The addition of erythropoietin (EPO) significantly enhanced angiogenesis in newly formed tissues. The effect of EPO of bacterial origin on bone tissue defect healing was demonstrated for the first time. The developed biomimetic highly porous UHMWPE/HA scaffold can be used separately or in combination with rhBMP-2 and EPO for reconstructive surgery to solve the problems associated with difference between implant architecture and trabecular bone, low osteointegration and bioinertness.


Assuntos
Materiais Biocompatíveis/química , Doenças Ósseas/cirurgia , Proteína Morfogenética Óssea 2/química , Durapatita/química , Eritropoetina/química , Polietilenos/química , Fator de Crescimento Transformador beta/química , Animais , Materiais Biocompatíveis/farmacologia , Doenças Ósseas/terapia , Proteína Morfogenética Óssea 2/metabolismo , Proteína Morfogenética Óssea 2/farmacologia , Proteína Morfogenética Óssea 2/uso terapêutico , Regeneração Óssea/efeitos dos fármacos , Osso e Ossos/patologia , Osso e Ossos/fisiologia , Portadores de Fármacos/química , Eritropoetina/metabolismo , Eritropoetina/farmacologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos ICR , Nanocompostos/química , Neovascularização Fisiológica/efeitos dos fármacos , Porosidade , Proteínas Recombinantes/química , Proteínas Recombinantes/metabolismo , Proteínas Recombinantes/farmacologia , Proteínas Recombinantes/uso terapêutico , Procedimentos de Cirurgia Plástica , Fator de Crescimento Transformador beta/metabolismo , Fator de Crescimento Transformador beta/farmacologia , Fator de Crescimento Transformador beta/uso terapêutico
8.
J Mech Behav Biomed Mater ; 85: 94-101, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29864747

RESUMO

An important research goal in the field of biomaterials lies in the progressive amendment of in vivo tests with suitable in vitro experiments. Such approaches are gaining more significance nowadays because of an increasing demand on life sciences and the ethical issues bound to the sacrifice of animals for the sake of scientific research. Another advantage of transferring the experiments to the in vitro field is the possibility of accurately control the boundary conditions and experimental parameters in order to reduce the need of validation tests involving animals. With the aim to reduce the amount of needed in vivo studies for this cause, a short-time in vitro test procedure using instrumented load increase tests with superimposed environmental loading has been developed at TUD to assess the mechanical long-term durability of ultra-high molecular weight polyethylene (UHMWPE) under fatigue loading in a biological environment.


Assuntos
Biomimética/métodos , Teste de Materiais/métodos , Fenômenos Mecânicos , Polietilenos , Próteses e Implantes , Biomimética/instrumentação , Dureza , Humanos , Teste de Materiais/instrumentação , Polietilenos/química , Suporte de Carga
9.
Materials (Basel) ; 11(11)2018 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-30445714

RESUMO

The evaluation of wear progress of gear tooth flanks made of 16MnCr5 was performed using non-destructive micro-magnetic testing, specifically Barkhausen noise (BN) and incremental permeability (IP). Based on the physical interaction of the microstructure with the magnetic field, the micro-magnetic characterization allowed the analysis of changes of microstructure caused by wear, including phase transformation and development of residual stresses. Due to wide parameter variation and application of bandpass filter frequencies of micro-magnetic signals, it was possible to indicate and separate the main damage mechanisms considering the wear development. It could be shown that the maximum amplitude of BN correlates directly with the profile form deviation and increases with the progress of wear. Surface investigations via optical and scanning electron microscopy indicated strong surface fatigue wear with micro-pitting and micro-cracks, evident in cross-section after 3 × 105 cycles. The result of fatigue on the surface layer was the decrease of residual compression stresses, which was indicated by means of coercivity by BN-analysis. The different topographies of the surfaces, characterized via confocal white light microscopy, were also reflected in maximum BN-amplitude. Using complementary microscopic characterization in the cross-section, a strong correlation between micro-magnetic parameters and microstructure was confirmed and wear progress was characterized in dependence of depth under the wear surface. The phase transformation of retained austenite into martensite according to wear development, measured by means of X-ray diffraction (XRD) and electron backscatter diffraction (EBSD) was also detected by micro-magnetic testing by IP-analysis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA