Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Biomed Eng Online ; 20(1): 15, 2021 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-33546713

RESUMO

BACKGROUND: The objective of the study was to validate biomechanical characteristics of a 3D-printed, novel-designated fixation plate for treating mandibular angle fracture, and compare it with two commonly used fixation plates by finite element (FE) simulations and experimental testing. METHODS: A 3D virtual mandible was created from a patient's CT images as the master model. A custom-designed plate and two commonly used fixation plates were reconstructed onto the master model for FE simulations. Modeling of angle fracture, simulation of muscles of mastication, and defining of boundary conditions were integrated into the theoretical model. Strain levels during different loading conditions were analyzed using a finite element method (FEM). For mechanical test design, samples of the virtual mandible with angle fracture and the custom-designed fixation plates were printed using selective laser sintering (SLS) and selective laser melting (SLM) printing methods. Experimental data were collected from a testing platform with attached strain gauges to the mandible and the plates at different 10 locations during mechanical tests. Simulation of muscle forces and temporomandibular joint conditions were built into the physical models to improve the accuracy of clinical conditions. The experimental vs the theoretical data collected at the 10 locations were compared, and the correlation coefficient was calculated. RESULTS: The results show that use of the novel-designated fixation plate has significant mechanical advantages compared to the two commonly used fixation plates. The results of measured strains at each location show a very high correlation between the physical model and the virtual mandible of their biomechanical behaviors under simulated occlusal loading conditions when treating angle fracture of the mandible. CONCLUSIONS: Based on the results from our study, we validate the accuracy of our computational model which allows us to use it for future clinical applications under more sophisticated biomechanical simulations and testing.


Assuntos
Placas Ósseas , Análise de Elementos Finitos , Fixação Interna de Fraturas/instrumentação , Fraturas Mandibulares/cirurgia , Fenômenos Biomecânicos , Humanos , Estresse Mecânico
2.
Technol Health Care ; 30(4): 1017-1030, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35275582

RESUMO

BACKGROUND: Customized prosthetic joint replacements have crucial applications in severe temporomandibular joint problems, and the combined use of porous titanium scaffold is a potential method to rehabilitate the patients. OBJECTIVE: The objective of the study was to develop a design method to obtain a titanium alloy porous condylar prosthesis with good function and esthetic outcomes for mandibular reconstruction. METHODS: A 3D virtual mandibular model was created from CBCT data. A condylar defect model was subsequently created by virtual condylectomy on the initial mandibular model. The segmented condylar defect model was reconstructed by either solid or porous condyle with a fixation plate. The porous condyle was created by a density-driven modeling scheme with an inhomogeneous tetrahedral lattice structure. The porous condyle, supporting fixation plate, and screw locations were topologically optimized. Biomechanical behaviors of porous and solid condylar prostheses made of Ti-6Al-4V alloy were compared. Finite element analysis (FEA) was used to evaluate maximum stress distribution on both prostheses and the remaining mandibular ramus. RESULTS: The FEA results showed levels of maximum stresses were 6.6%, 36.4% and 47.8% less for the porous model compared to the solid model for LCI, LRM, and LBM loading conditions. Compared to the solid prosthesis, the porous prosthesis had a weight reduction of 57.7% and the volume of porosity of the porous condyle was 65% after the topological optimization process. CONCLUSIONS: A custom-made porous condylar prosthesis with fixation plate was designed in this study. The 3D printed Ti-6Al-4V porous condylar prosthesis had reduced weight and effective modulus of elasticity close to that of cortical bone. The.


Assuntos
Prótese Articular , Titânio , Análise de Elementos Finitos , Humanos , Mandíbula , Porosidade , Impressão Tridimensional , Desenho de Prótese , Articulação Temporomandibular/cirurgia , Titânio/química
3.
3D Print Med ; 5(1): 5, 2019 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-30874929

RESUMO

BACKGROUND: Our long-term goal is to design and manufacture a customized graft with porous scaffold structure for repairing large mandibular defects using topological optimization and 3D printing technology. The purpose of this study is to characterize the mechanical behavior of 3D printed anisotropic scaffolds as bone analogs by fused deposition modeling (FDM). METHODS: Cone beam computed tomography (CBCT) images were used to reconstruct a 3D mandible and finite element models. A virtual sectioned-block of the mandible was used as the control group and the trabecular portion of the block was modified by topological optimization methods as experimental groups. FDM (FDM) printed samples at 0, 45 and 90 degrees with Poly-lactic acid (PLA) material under a three-point bending test. Finite element analysis was also used to validate the data obtained from the physical model tests. RESULTS: The ultimate load, yield load, failure deflection, yield deflection, stress, strain distribution, and porosity of scaffold structures were compared. The results show that the topological optimized graft had the best mechanical properties. CONCLUSIONS: The results from mechanical tests on physical models and numerical simulations from this study show a great potential for topological optimization and 3D printing technology to be served in design and rapidly manufacturing of artificial porous grafts.

4.
J Plast Reconstr Aesthet Surg ; 72(2): 281-289, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30482534

RESUMO

BACKGROUND: For large mandibular defects, surgical reconstruction using microvascular fibular grafts has advantages over other alternatives in terms of blood supply and good quality of grafted bone. However, the fibular segment is usually lower in height than that of the original mandible, meaning that the vertical positioning of the fibular graft is variable, with different biomechanical consequences on the reconstructed mandible. OBJECTIVES: To use finite element method (FEM) to evaluate stress distribution and displacement of a reconstructed mandible versus an intact mandible under occlusal loads. METHODS: A three-dimensional intact edentulous mandibular bone (Model I) and a reconstructed mandible bone with fibular graft were created from CBCT images. Calculation models were generated with fibular bone graft extracted from the reconstructed mandible of identical length placed into a mimicked defect area on the right-hand side of the mandible at three different vertical positions: superior (Model II), intermediate (Model III), and inferior (Model IV). Forces were applied at lower left first molar region and lower left central incisor area. Von Mises stresses and mandibular displacement were calculated as outcome measurements during loadings. RESULTS: Maximum stress and strain within the reconstructed mandible were identified at the posterior border of the graft and the contralateral condyle. Maximum displacement occurred near the interface of fibular graft and anterior segment of the mandible. Stress distribution in the graft under functional loads is much higher than that in the residual mandibular segments from Models II to IV. The combined average maximum stress from anterior and posterior loads is 10.66 times higher in the mandible with inferiorly positioned graft (Model IV), 8.72 times for superior graft (Model II), and 3.68 times for intermediate graft (Model III) than that in the control group (Model I). The worst displacement result during functional loadings was in the group with fibular graft located at the inferior border of the mandible. CONCLUSIONS: The position of fibular graft placed in the surgical resection site has significant effects on the mechanical behavior of the reconstructed mandible. The fibular graft aligned with the inferior border of the mandible, the most common site designated location by clinicians, has the worst effects on the stress distribution and displacement to the mandibular under functional loads. The fibular graft placed at the intermediate location has the best biomechanics and provides favorable condition for subsequent prosthetic reconstruction.


Assuntos
Fíbula/transplante , Mandíbula/fisiologia , Mandíbula/cirurgia , Reconstrução Mandibular/métodos , Fenômenos Biomecânicos , Fíbula/irrigação sanguínea , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional , Mandíbula/irrigação sanguínea , Mandíbula/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA