J Spinal Disord Tech ; 24(6): E49-56, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21685804

RESUMO

STUDY DESIGN: An in vitro biomechanical cadaver study. OBJECTIVES: To evaluate the pull-out strength after 5000 cyclic loading among 4 revision techniques for the loosened iliac screw using corticocancellous bone, longer screw, traditional cement augmentation, and boring cement augmentation. SUMMARY OF BACKGROUND DATA: Iliac screw loosening is still a clinical problem for lumbo-iliac fusion. Although many revision techniques using corticocancellous bone, larger screw, and polymethylmethacrylate (PMMA) augmentation were applied in repairing pedicle screw loosening, their biomechanical effects on the loosened iliac screw remain undetermined. METHODS: Eight fresh human cadaver pelvises with the bone mineral density values ranging from 0.83 to 0.97 g/cm were adopted in this study. After testing the primary screw of 7.5 mm diameter and 70 mm length, 4 revision techniques were sequentially established and tested on the same pelvis as follows: corticocancellous bone, longer screw with 100 mm length, traditional PMMA augmentation, and boring PMMA augmentation. The difference of the boring technique from traditional PMMA augmentation is that PMMA was injected into the screw tract through 3 boring holes of outer cortical shell without removing the screw. On an MTS machine, after 5000 cyclic compressive loading of -200∼-500 N to the screw head, axial maximum pull-out strengths of the 5 screws were measured and analyzed. RESULTS: The pull-out strengths of the primary screw and 4 revised screws with corticocancellous bone, longer screw and traditional and boring PMMA augmentation were 1167 N, 361 N, 854 N, 1954 N, and 1820 N, respectively. Although longer screw method obtained significantly higher pull-out strength than corticocancellous bone (P<0.05), the revised screws using these 2 techniques exhibited notably lower pull-out strength than the primary screw and 2 PMMA-augmented screws (P<0.05). Either traditional or boring PMMA screw showed obviously higher pull-out strength than the primary screw (P<0.05); however, no significant difference of pull-out strength was detected between the 2 PMMA screws (P>0.05). CONCLUSIONS: Wadding corticocancellous bone and increasing screw length failed to provide sufficient anchoring strength for a loosened iliac screw; however, both traditional and boring PMMA-augmented techniques could effectively increase the fixation strength. On the basis of the viewpoint of minimal invasion, the boring PMMA augmentation may serve as a suitable salvage technique for iliac screw loosening.


Assuntos
Cimentos Ósseos , Parafusos Ósseos , Ílio/cirurgia , Vértebras Lombares/cirurgia , Falha de Prótese , Idoso , Fenômenos Biomecânicos , Feminino , Humanos , Fixadores Internos , Masculino , Pessoa de Meia-Idade , Reoperação
2.
Clin Biomech (Bristol, Avon) ; 26(6): 556-61, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21345556

RESUMO

BACKGROUND: Iliac screw loosening has been a clinical problem in the lumbo-pelvic reconstruction. Although iliac screws are commonly inserted into either upper or lower iliac column, the biomechanical effects of the two fixations and their revision techniques with bone cement remain undetermined. The purpose of this study was to compare the anchoring strengths of the upper and lower iliac screws with and without cement augmentation. METHODS: 5 pairs of formalin fixed cadaveric ilia with the bone mineral density values ranged from 0.82 to 0.97 g/cm(2) were adopted in this study. Using screws with 70-mm length and 7.5-mm diameter, 2 conventional iliac screw fixations and their revision techniques with cement augmentation were sequentially established and tested on the same ilium as follows: upper screw, upper cement screw, lower screw, and lower cement screw. Following 2000 cyclic compressive loading of -300 N to -100 N to the screw on a material testing machine, the maximum pull-out strengths were measured and analyzed. FINDINGS: The average pull-out strengths of upper, upper cement, lower, and lower cement screws were 964 N, 1462 N, 1537 N, and 1964 N, respectively. The lower screw showed significantly higher pull-out strength than the upper one (P=0.008). The cement augmentation notably increased the pull-out strengths of both upper and lower screws. The positive correlation between pull-out strength and bone mineral density value was obtained for the 4 fixations. INTERPRETATION: The lower iliac screw technique should be the preferred choice in lumbo-pelvic stabilization surgery; cement augmentation may serve as a useful salvage technique for iliac screw loosening; preoperative evaluation of bone quality is crucial for predicting fixation strength of iliac screw.


Assuntos
Cimentos Ósseos/química , Parafusos Ósseos , Idoso , Fenômenos Biomecânicos , Densidade Óssea , Feminino , Humanos , Ílio/química , Masculino , Pessoa de Meia-Idade , Ossos Pélvicos/patologia , Pelve/patologia , Estresse Mecânico