Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
ACS Appl Mater Interfaces ; 12(42): 47245-47255, 2020 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-32955238

RESUMO

In this work, nitrogen-doped carbon quantum dots from poly(ethyleneimine) (PQDs) were synthesized by a low-cost and facile one-step hydrothermal method without other reagents. A quantum yield (QY) of up to 23.2% with maximum emission at 460 nm under an excitation wavelength of 340 nm was ascribed to the high nitrogen doping (20.59%). The PQDs selectively form a blue complex with Cu2+ accompanied by strong quenching of the fluorescence emission. Meanwhile, the PQD-Cu2+ complex exhibited selective fluorescence recovery and color disappearance on exposure to l-cysteine (Cys). The electron transfer from amino or oxygen groups on the PQDs to Cu2+ leads to fluorescence quenching, and a chromogenic reaction of the cuprammonium complex results in a color change. The strong affinity between Cys and Cu2+ causes the detachment of Cu2+ from the surface of PQDs, so the color of the solution disappears and the fluorescence of PQDs recovers. Under the optimized condition, the proposed sensor was applied to detect Cu2+ in the linear range of 0-280 µM. A detection limit of 4.75 µM is achieved using fluorescence spectroscopy and 4.74 µM by monitoring the absorbance variation at 272 nm. For Cys detection, the linear range of 0-800 µM with detection limits of 28.11 µM (fluorescence determination) and 19.74 µM (peak shift determination at 272 nm) was obtained. Meanwhile, the PQD-Cu2+ system exhibits distinguishable responses to other biothiols such as l-glutathione (GSH) and dl-homocysteine (Hcy). Based on the multimode signals, an "AND" logic gate was constructed successfully. Interestingly, besides Cu2+, Fe3+ can also quench the fluorescence of PQDs and the PQD-Fe3+ system exhibits superior selectivity for Cys detection. Most importantly, the proposed assay is not only simple, cheap, and stable but also suitable for detecting Cu2+ and Cys in some real samples.


Assuntos
Cobre/análise , Cisteína/análise , Poluentes Radioativos da Água/análise , Carbono/química , Colorimetria , Fluorescência , Lagos , Nitrogênio/química , Tamanho da Partícula , Polietilenoimina/química , Pontos Quânticos/química , Propriedades de Superfície , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA