Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Nanobiotechnology ; 22(1): 337, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38886712

RESUMO

BACKGROUND: Molybdenum disulfide (MoS2) has excellent physical and chemical properties. Further, chiral MoS2 (CMS) exhibits excellent chiroptical and enantioselective effects, and the enantioselective properties of CMS have been studied for the treatment of neurodegenerative diseases. Intriguingly, left- and right-handed materials have different effects on promoting the differentiation of neural stem cells into neurons. However, the effect of the enantioselectivity of chiral materials on peripheral nerve regeneration remains unclear. METHODS: In this study, CMS@bacterial cellulose (BC) scaffolds were fabricated using a hydrothermal approach. The CMS@BC films synthesized with L-2-amino-3-phenyl-1-propanol was defined as L-CMS. The CMS@BC films synthesized with D-2-amino-3-phenyl-1-propanol was defined as D-CMS. The biocompatibility of CMS@BC scaffolds and their effect on Schwann cells (SCs) were validated by cellular experiments. In addition, these scaffolds were implanted in rat sciatic nerve defect sites for three months. RESULTS: These chiral scaffolds displayed high hydrophilicity, good mechanical properties, and low cytotoxicity. Further, we found that the L-CMS scaffolds were superior to the D-CMS scaffolds in promoting SCs proliferation. After three months, the scaffolds showed good biocompatibility in vivo, and the nerve conducting velocities of the L-CMS and D-CMS scaffolds were 51.2 m/s and 26.8 m/s, respectively. The L-CMS scaffolds showed a better regenerative effect than the D-CMS scaffolds. Similarly, the sciatic nerve function index and effects on the motor and electrophysiological functions were higher for the L-CMS scaffolds than the D-CMS scaffolds. Finally, the axon diameter and myelin sheath thickness of the regenerated nerves were improved in the L-CMS group. CONCLUSION: We found that the CMS@BC can promote peripheral nerve regeneration, and in general, the L-CMS group exhibited superior repair performance. Overall, the findings of this study reveal that CMS@BC can be used as a chiral nanomaterial nerve scaffold for peripheral nerve repair.


Assuntos
Celulose , Dissulfetos , Molibdênio , Regeneração Nervosa , Células de Schwann , Alicerces Teciduais , Regeneração Nervosa/efeitos dos fármacos , Animais , Ratos , Alicerces Teciduais/química , Dissulfetos/química , Dissulfetos/farmacologia , Células de Schwann/efeitos dos fármacos , Molibdênio/química , Molibdênio/farmacologia , Celulose/química , Celulose/farmacologia , Celulose/análogos & derivados , Ratos Sprague-Dawley , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Nervo Isquiático/efeitos dos fármacos , Nervo Isquiático/fisiologia , Proliferação de Células/efeitos dos fármacos , Engenharia Tecidual/métodos , Masculino , Traumatismos dos Nervos Periféricos , Estereoisomerismo
2.
Nano Lett ; 18(10): 6164-6174, 2018 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-30207473

RESUMO

Cell membrane-camouflaged nanoparticles have appeared as a promising platform to develop active tumor targeting nanomedicines. To evade the immune surveillance, we designed a composite cell membrane-camouflaged biomimetic nanoplatform, namely, leutusome, which is made of liposomal nanoparticles incorporating plasma membrane components derived from both leukocytes (murine J774A.1 cells) and tumor cells (head and neck tumor cells HN12). Exogenous phospholipids were used as building blocks to fuse with two cell membranes to form liposomal nanoparticles. Liposomal nanoparticles made of exogenous phospholipids only or in combination with one type of cell membrane were fabricated and compared. The anticancer drug paclitaxel (PTX) was used to make drug-encapsulating liposomal nanoparticles. Leutusome resembling characteristic plasma membrane components of the two cell membranes were examined and confirmed in vitro. A xenograft mouse model of head and neck cancer was used to profile the blood clearance kinetics, biodistribution, and antitumor efficacy of the different liposomal nanoparticles. The results demonstrated that leutusome obtained prolonged blood circulation and was most efficient accumulating at the tumor site (79.1 ± 6.6% ID per gram of tumor). Similarly, leutusome composed of membrane fractions of B16 melanoma cells and leukocytes (J774A.1) showed prominent accumulation within the B16 tumor, suggesting the generalization of the approach. Furthermore, PTX-encapsulating leutusome was found to most potently inhibit tumor growth while not causing systemic adverse effects.


Assuntos
Biomimética/métodos , Membrana Celular/metabolismo , Lipossomos/metabolismo , Melanoma Experimental/tratamento farmacológico , Animais , Linhagem Celular Tumoral , Membrana Celular/química , Sistemas de Liberação de Medicamentos , Humanos , Leucócitos , Lipossomos/química , Melanoma Experimental/metabolismo , Melanoma Experimental/patologia , Camundongos , Nanopartículas/química , Paclitaxel/química , Paclitaxel/farmacologia , Distribuição Tecidual , Ensaios Antitumorais Modelo de Xenoenxerto
3.
J Spinal Disord Tech ; 27(3): E88-93, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-23563348

RESUMO

STUDY DESIGN: A retrospective comparative study. OBJECTIVE: The purpose of this study is to assess radiologic features of intravertebral cleft (IVC) in nonacute osteoporotic vertebral compression fractures (OVCFs) patients, and analyze the existence of IVC impact on outcomes of percutaneous kyphoplasty (PKP). SUMMARY OF BACKGROUND DATA: The IVC sign is regarded as vertebral instability and the cause of persisting pain. It is more likely to happen at nonacute OVCFs patients. Patients with IVC sign have different outcomes from these without IVC treated by percutaneous vertebroplasty. There were rare reports about the outcomes of patients with IVC sign treated by PKP. MATERIALS AND METHODS: We divided 92 nonacute OVCFs patients (total of 113 vertebrae) into 2 groups according to the existence of IVC. Preoperative and postoperative Visual Analogue Scales, Oswestry Disability Index, kyphotic angulation (KA), and anterior vertebral height were recorded; the incidence and radiologic features of IVC were analyzed. RESULTS: The diagnostic sensitivity of IVC on plain radiograph, computed tomography, and magnetic resonance imaging were 35.4%, 89.3%, and 83.3%, respectively. The IVC group had an average correction KA of 9.14 degrees and reduction of ratio of compression of 20.09%, and the non-IVC group was 8.76 degrees and 20.23%, respectively. Cleft pattern of cement accounted for 64.6% in IVC group and 27.7% in non-IVC group. Five/7 of cement leakage in IVC group was intradiscal leakage, whereas 7/9 of cement leakage in non-IVC group was perivertebral leakage. CONCLUSIONS: Computed tomography and magnetic resonance imaging were more sensitivity to diagnose IVC sign than X-ray. PKP could improve pain, functional activity, KA, and anterior height of both IVC and non-IVC groups, however, there was more cleft pattern of cement and higher intradiscal cement leakage in the IVC group.


Assuntos
Fraturas por Compressão/cirurgia , Cifoplastia/métodos , Fraturas por Osteoporose/cirurgia , Fraturas da Coluna Vertebral/cirurgia , Coluna Vertebral/patologia , Coluna Vertebral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Cimentos Ósseos/efeitos adversos , Força Compressiva , Avaliação da Deficiência , Feminino , Fraturas por Compressão/complicações , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/fisiopatologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Fraturas por Osteoporose/complicações , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/fisiopatologia , Medição da Dor , Estudos Retrospectivos , Fraturas da Coluna Vertebral/complicações , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/fisiopatologia , Coluna Vertebral/fisiopatologia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
4.
Orthop Surg ; 14(2): 443-450, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34914198

RESUMO

This study sought to investigate and evaluate a modified axial translaminar screw fixation for treating odontoid fractures. We performed a retrospective study at Wenzhou Medical University Affiliated Second Hospital between March 2016 and June 2018. We retrospectively collected and analyzed the medical records of 23 cases with odontoid fractures. All patients were identified as type II odontoid fractures without neurological deficiency and serious diseases following the classification of Anderson. The average age, gender ratio, and body mass index (BMI) were 54.3 ± 11.1 years, 12 men to 11 women, and 22.6 ± 2.4 kg/m2 , respectively. Patients in this study accepted screw fixation using our modified axial translaminar screw fixation combined with atlas pedicle or lateral mass screw fixation. Within the technique, a small cortical "window" was dug in the middle of the axial contralateral lamina, such that the screws in the lamina were visualized to prevent incorrectly implanting the posterior spinal canal through the visualized "window." A total of 46 bone screws were accurately inserted into the axial lamina without using fluoroscopy. The length of all translaminar screws ranged between 26 and 30 mm, while the diameter was 3.5 mm. During the follow-up survey, the visual analog scale (VAS) and neck disability index (NDI) were measured. We provide a simple modification of Wright's elegant technique with the addition of "visualized windows" at the middle of the axial lamina. In all patients, screws were inserted accurately without bony breach and the screw angle was 56.1 ± 3.0°. Mean operative time was 102 ± 28 min with an average blood loss of 50 ± 25 mL. Postoperative hemoglobin and mean length of hospital stay were 12.0 ± 1.4 g/dL and 10.4 ± 3.4 days, respectively. The average follow-up time of all cases was 14.7 months and no internal fixation displacement, loosening, or breakage was found. All patients with odontoid fractures reported being satisfied with the treatment during the recheck period and good clinical outcomes were observed. At 1, 6, and 12 months, NDI and VAS showed that the symptoms of neck pain and limitations of functional disability improved significantly during follow-up. Our results suggest that the modified translaminar screw fixation technique can efficiently treat Anderson type II odontoid fracture, followed by the benefits of less soft tissue dissection, simple operation, no fluoroscopy, and accurate placement of screws.


Assuntos
Processo Odontoide , Fraturas da Coluna Vertebral , Fusão Vertebral , Adulto , Idoso , Parafusos Ósseos , Feminino , Fixação Interna de Fraturas/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Processo Odontoide/diagnóstico por imagem , Processo Odontoide/lesões , Processo Odontoide/cirurgia , Estudos Retrospectivos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Fusão Vertebral/métodos , Resultado do Tratamento
5.
J Spinal Disord Tech ; 23(2): 113-20, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20051922

RESUMO

STUDY DESIGN: Surgical techniques and preliminary results. OBJECTIVE: To describe and evaluate the safety and efficacy of a new minimal invasive technique for the irreducible atlantoaxial dislocation (IADD). SUMMARY OF BACKGROUND DATA: Endoscope has been widely used in minimal invasive spinal surgery. However, there are no clinical reports regarding anterior approach for IADD in the literature. METHODS: Ten consecutive patients with IADD were treated by anterior release with microendoscopic aide and subsequently reduction, anterior transarticular screw fixation and morselized autologous bone grafts. There were 3 cases of odontoid dysplasia, 4, chronic odontoid fracture, 1, odontoid absence, 1 fasilar impression, and 1 malunion of odontoid fracture. According to Symon and Lavender's classification of disability, 6 cases were moderate disability, 3 severe nonbedbound, and 1 severe bedridden. The procedure was performed by the same surgeon (Yong-Long Chi). RESULTS: The new technique was performed successfully in all cases. All the patients underwent transarticular screw fixation and anterior morselized autograft fusion. The average operation time was 120 min (range, 90 to 150 min) and the mean estimated blood loss was 150 mL (range, 100 to 250 mL). Postoperative radiographs demonstrated that 9 cases restored anatomic position and 1 had partial reduction. According to the postoperative computed tomography all the screws were appropriately placed. Follow-up after surgery, longest is 16 months and minimal 8 months with a mean of 12 months, neurologic status was improved in all patients. There was no loss of fixation and solid fusion was achieved in all cases. CONCLUSIONS: Surgical technique of microendoscopic anterior release, reduction, fixation, and fusion is safe and reliable minimally invasive for treating IADD.


Assuntos
Articulação Atlantoaxial/cirurgia , Endoscopia/métodos , Luxações Articulares/cirurgia , Instabilidade Articular/cirurgia , Microcirurgia/métodos , Fusão Vertebral/métodos , Adulto , Articulação Atlantoaxial/diagnóstico por imagem , Articulação Atlantoaxial/patologia , Vértebra Cervical Áxis/diagnóstico por imagem , Vértebra Cervical Áxis/patologia , Vértebra Cervical Áxis/cirurgia , Parafusos Ósseos , Transplante Ósseo , Atlas Cervical/diagnóstico por imagem , Atlas Cervical/patologia , Atlas Cervical/cirurgia , Feminino , Humanos , Fixadores Internos , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/patologia , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/patologia , Masculino , Microcirurgia/instrumentação , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Neurocirúrgicos/instrumentação , Procedimentos Neurocirúrgicos/métodos , Processo Odontoide/diagnóstico por imagem , Processo Odontoide/patologia , Processo Odontoide/cirurgia , Radiografia , Estudos Retrospectivos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/patologia , Fraturas da Coluna Vertebral/cirurgia , Fusão Vertebral/instrumentação , Resultado do Tratamento
6.
J Invest Surg ; 33(2): 134-140, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29883213

RESUMO

ABSTRACTPurpose: To measure the projection of the most anterior line of the spinal canal on lateral radiographs of the vertebra (C3-L5) and evaluate the efficacy of the safety line (SL) in preventing intraspinal cement leakage in percutaneous kyphoplasty (PKP) and percutaneous vertebroplasty (PVP). Materials and Methods: Fifteen adult dry-bone spine specimens were analyzed. The projection of the SL was viewed on lateral radiographs. The distance between the SL and the posterior vertebral body line (PVBL) was measured. Two groups of patients were treated by PKP, and cement injection was stopped either before the PBVL (group 1) or before the SL (group 2) under lateral fluoroscopy. The rate of cement leakage was compared between the two groups. Results: The largest distance between the SL and PVBL was at L1 (5.22 ± 0.62 mm). From L1 to L5, the distance decreased progressively to 1.05 ± 0.64 mm. Similar variation was also observed from L1 to T1 (0.19 ± 0.18 mm). The postoperative computed tomography scan was more sensitive and accurate in detecting intraspinal leakage than radiography in group 1 (p = 0.000); however, there was no significant difference in sensitivity or accuracy between methods in group 2 (p = 0.063). The rate of intraspinal cement leakage was significantly higher in group 1 than group 2 (p = 0.000). Conclusions: The operator should frequently check to ensure that cement injection has stopped upon reaching the SL. Surgeons may benefit from this quantitative anatomical study of PKP and PVP.


Assuntos
Cifoplastia/métodos , Complicações Pós-Operatórias/prevenção & controle , Canal Medular/anatomia & histologia , Vertebroplastia/métodos , Adulto , Idoso , Cimentos Ósseos/efeitos adversos , Cadáver , Fluoroscopia , Humanos , Cifoplastia/efeitos adversos , Masculino , Pessoa de Meia-Idade , Fraturas por Osteoporose/cirurgia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Canal Medular/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Vertebroplastia/efeitos adversos
7.
World Neurosurg ; 114: e66-e69, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29476998

RESUMO

PURPOSE: We sought to report a minimum 12 months' follow-up results of our improved bone graft method for upper cervical surgery with the posterior approach. METHODS: Among 52 consecutive cases, odontoid nonunion occurred in 33 patients, atlantoaxial instability in 11 patients, and occipitocervical deformity in 8 patients who underwent posterior C1-C2 transarticular screw/screw-rod internal fixation (41 cases) and occipitocervical fusion (11 cases) with the improved bone graft technique. Each surgical procedure was performed by the same senior spine surgeon. We took lateral cervical standing roentgenograms before surgery and immediately after surgery. Then we conducted craniocerebral computed tomography examination with reconstruction at 3, 6, 12, and 24 months and annually thereafter. The postoperative follow-up times are about 12-38 months. RESULTS: All cases showed satisfactory screw fixation by radiographic examination, and there were no postoperative neurologic complications. One case had postoperative retropharyngeal infection after the transoral release and posterior reduction by pedicle screw instrumentation. All patients got solid fusions, and no pseudarthrosis occurred. All cases had solid fusions at the 3-month follow-up. CONCLUSION: Good bone graft bed, enough bone graft material, solid local fixation, and effective bone graft method are prerequisites for a successful bone graft. By analyzing postoperative follow-up in the consecutive cases in this study, our bone graft method describing a new bone graft structure is a reliable posterior fusion technique. It is worth considering, and further research is needed.


Assuntos
Articulação Atlantoaxial/cirurgia , Transplante Ósseo , Vértebras Cervicais/cirurgia , Instabilidade Articular/cirurgia , Adulto , Idoso , Articulação Atlantoaxial/diagnóstico por imagem , Transplante Ósseo/efeitos adversos , Transplante Ósseo/métodos , Vértebras Cervicais/diagnóstico por imagem , Feminino , Fixação Interna de Fraturas/métodos , Humanos , Instabilidade Articular/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Fusão Vertebral/métodos
8.
World Neurosurg ; 120: e488-e496, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30149177

RESUMO

OBJECTIVE: We sought to acquire the whole sagittal spine parameters and investigated the acceptable chin-brow vertical angle (CBVA) for neutral position radiography in an asymptomatic Chinese population. METHODS: The parameters measured in 257 asymptomatic volunteers included CBVA, occipital slope, orbital tilt, occipital incidence, C0-C2 Cobb angle, C2-C7 Cobb angle, C1-C7 Cobb angle, C2-C7 sagittal vertical axis and absolute rotation angle, cervical tilt, cranial tilt, T1 slope, and thoracic kyphosis, and others. We used Pearson correlation analyses to find relationships between CBVA and other variables. The subjects were divided into 5 groups according to the CBVA percentile: group A, 0%-20% CBVA; group B, 20%-40% CBVA; group C, 40%-60% CBVA; group D, 60%-80% CBVA; and group E, 80%-100% CBVA. We used analysis of variance to analyze differences among the 5 groups. RESULTS: Orbital tilt, Occipital incidence, C1-C7 Cobb angle, C2-C7 sagittal vertical axis, and cranial tilt all increased with increasing CBVA (P < 0.001). The occipital slope, C2-C7 Cobb angle, C2-C7 absolute rotation angle, cervical tilt, T1 slope, and thoracic kyphosis decreased with decreasing CBVA (P < 0.05). No correlations between other sagittal parameters and the CBVA were found. A slight deviation was found in groups B-D, with a greater deviation in groups A, C, and E. CONCLUSIONS: An acceptable range of -1.5° to 5.8° is recommended for the CBVA for cervical radiography in the neutral position. When spinal surgeons evaluate the cervical plane, the effects of the CBVA deviation on cervical curvature must be considered.


Assuntos
Queixo/anatomia & histologia , Sobrancelhas/anatomia & histologia , Radiografia/métodos , Coluna Vertebral/diagnóstico por imagem , Adulto , Idoso , Povo Asiático , Vértebras Cervicais/diagnóstico por imagem , Estudos Transversais , Feminino , Voluntários Saudáveis , Humanos , Cifose/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Posicionamento do Paciente , Estudos Retrospectivos , Adulto Jovem
9.
Zhonghua Wai Ke Za Zhi ; 45(6): 383-6, 2007 Mar 15.
Artigo em Zh | MEDLINE | ID: mdl-17537322

RESUMO

OBJECTIVE: To evaluate the safety and efficacy of one-stage percutaneous microendoscopic anterior release, trans-articular fixation and fusion to reduce and stabilize for irreducible atlanto-axial dislocation. METHODS: Eight consecutive patients were treated by percutaneous microendoscopic anterior release, trans-articular C(1-2) fixation and bone graft fusion. The mean age was 33 years (range, 28-52 years). The pathology included odontoid dysplasia in 3 patients, chronic odontoid fractures in 2, odontoid absence in 1, fasilar impression in 1 and malunion of odontoid fracture in 1. The classification of disability was that proposed by Symon and Lavender. There were moderate disability in 4, severe non-bedbound in 3, and severe bedridden in 1. RESULTS: The new technique was performed successfully in all cases. All patients underwent trans-articular C(1-2) screw fixation and anterior bone graft fusion. The average operation time was 120 min (90-150 min), and the average estimated blood loss was 150 ml (100-250 ml). Seven cases resulted in anatomic reduction, 1 had partial reduction. The follow-up period was 8-16 months. The effective rate was 100%, and the excellent rate was 51.25%; the average improvement rate for the spinal canal decompression was 76.5%. There was no instrument failure or pseudarthrosis, and solid fusion was achieved in the all cases. The loss of axial rotation of cervical spine was 30-40 degrees . CONCLUSION: Percutaneous microendoscopic anterior release, fixation and fusion is an effective, reliable, and safe procedure for the treatment of irreducible atlanto-axial dislocation.


Assuntos
Articulação Atlantoaxial , Fixação Interna de Fraturas/métodos , Luxações Articulares/cirurgia , Fusão Vertebral/métodos , Adulto , Endoscopia/métodos , Feminino , Seguimentos , Humanos , Masculino , Microcirurgia , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Resultado do Tratamento
10.
Medicine (Baltimore) ; 96(46): e8509, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29145253

RESUMO

RATIONALE: The complication of iatrogenic distraction of odontoid fracture after anterior screw fixation has not been reported in the literature. We treated the patient with endoscopically assisted bone grafting with good results. The new technique was not reported in the management of odontoid fracture or nonunion before. PATIENT CONCERNS: A 22-year-old man presented with neck pain after a motorcycle crash. The cervical spine radiograph and computed tomographic scan demonstrated the base of dens displaced 2 mm anteriorly. DIAGNOSES: Radiographic images showed a type II odontoid fracture. INTERVENTIONS: The patient was treated by percutaneous anterior screw fixation. The postoperative radiograph and CT demonstrated an iatrogenic distraction of the odontoid with a gap of 6 mm.The follow-up radiograph did not show any sign of bone union 1 month and a half later. A revision surgery was given by anterior endoscopically assisted bone grafting. The patient was encouraged to sit out of bed immediately after the surgery with the protection of a soft cervical collar for 3 months. OUTCOMES: No complications such as neural structures or vascular injuries were found. Bone union was achieved at the 1-year follow-up CT scans. Physical examination showed a full range of motion in the neck. LESSONS: We reported a case of iatrogenic odontoid distraction that was managed by anterior endoscopically assisted bone grafting. It is a technically feasible and minimally invasive procedure.


Assuntos
Transplante Ósseo/métodos , Processo Odontoide/lesões , Endoscopia , Fixação de Fratura/efeitos adversos , Humanos , Doença Iatrogênica , Masculino , Processo Odontoide/cirurgia , Adulto Jovem
11.
J Orthop Surg Res ; 12(1): 141, 2017 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-28962628

RESUMO

BACKGROUND: The objective of this study is to investigate the outcomes and safety of using percutaneous anterior C1/2 transarticular screw fixation as a salvage technique for odontoid fracture if percutaneous odontoid screw fixation fails. METHODS: Fifteen in 108 odontoid fracture patients (planned to be treated by percutaneous anterior odontoid screw fixation) were failed to introduce satisfactory odontoid screw trajectory. To salvage this problem, we chose the percutaneous anterior C1/2 transarticular screw fixation technique in treatment of these patients. The visual analogue score (VAS) of neck pain and Neck Disability Index (NDI) of all patients were scored at pre-operation, 3 months after operation, and final follow-up. Additional, technique-related complications were recorded and collected. RESULTS: Percutaneous C1/2 transarticular screw fixation was performed successfully in all 15 patients whose odontoid screw fixation failed. No technique-related complications (such as nerve injury, spinal cord injury, and esophageal injury) occurred. The VAS of neck pain and NDI score improved significantly (P = 0.000) after operation, and no significant differences were found when compared to 93 non-salvage patients who successfully performed the percutaneous anterior odontoid screw fixation. No screw loose or breakage occurred, all of the odontoid fractures achieve radiographic fusion, bony fusion bridge could be observed at the C1/2 lateral articular facet on 9/15 patients. CONCLUSIONS: We suggest that percutaneous anterior C1/2 transarticular screw fixation is a good alternative salvage technique if percutaneous odontoid screw fixation failed, and it is a minimally invasive, feasible, and safe technique.


Assuntos
Vértebras Cervicais/cirurgia , Fixação Interna de Fraturas/métodos , Processo Odontoide/lesões , Processo Odontoide/cirurgia , Fraturas da Coluna Vertebral/cirurgia , Adulto , Idoso , Parafusos Ósseos , Feminino , Seguimentos , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Cervicalgia/diagnóstico por imagem , Cervicalgia/etiologia , Cervicalgia/cirurgia , Processo Odontoide/diagnóstico por imagem , Medição da Dor/métodos , Radiografia , Terapia de Salvação/métodos , Fraturas da Coluna Vertebral/complicações , Fraturas da Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Resultado do Tratamento
12.
Zhonghua Yi Xue Za Zhi ; 86(43): 3047-50, 2006 Nov 21.
Artigo em Zh | MEDLINE | ID: mdl-17288834

RESUMO

OBJECTIVE: To investigate the therapeutic effects and complications of percutaneous anterior screw fixation for odontoid fractures. METHODS: Twenty-eight patients with odontoid fractures, 21 males and 7 females, aged 38.6 (21-72), 12 with type II fractures and 16 with type III fractures, including 10 cases with shallow type III fractures, according to Anderson's classification system, underwent percutaneous anterior odontoid screw fixation with one screw implant. Five to seven days after the operation the patients got out of bed to conduct dirigation. Prostheses were used for 8-12 weeks post-operationally. The patients were followed up for 43.2 months (26-62 months). Radiological examination, including X-ray and CT examinations, and clinical examinations were carried out to observe the therapeutic effects. RESULTS: Radiological examination showed bony union in 25 cases (89.3%), and non-union developed in 2 cases, 1 case was switched to posterior fusion surgery because of redisplaced fracture. The union rate was 83.3% in the type II fracture, and was 93.8% in the type III. Majority of the patients resumed an excellent cervical motion. No severe complication such as esophagus and carotid artery injury related with puncture was found. One patient had temporary superior laryngeal nerve paralysis, The screw tail was detained at the superior margin of C3 vertebral body in 5 cases, the screw penetrate the tip of odontoid process in 1 case, and the screw thread failed to pass the fracture site entirely in 1 case. CONCLUSION: An innovative alternative method with the advantages of convenient procedure, less bleeding, gentle injury for surrounding tissue, and rapid recovery, percutaneous anterior odontoid screw fixation is similarly effective as open anterior odontoid screw fixation, for the treatment of odontoid fractures. Related complication is rare and not severe. The surgery has.


Assuntos
Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Fraturas da Coluna Vertebral/cirurgia , Adulto , Idoso , Vértebras Cervicais/lesões , Feminino , Seguimentos , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/instrumentação , Humanos , Fixadores Internos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Retrospectivos , Fraturas da Coluna Vertebral/etiologia
13.
J Spinal Cord Med ; 39(2): 234-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-25659962

RESUMO

CONTEXT/OBJECTIVE: To describe the technique and clinical results of percutaneous atlantoaxial anterior transarticular fixation combined with limited exposure posterior C1/2 arthrodesis in patients with a high-riding vertebral artery. DESIGN SETTING: Zhejiang Spine Center, China. PARTICIPANTS: Five patients with a high-riding vertebral artery and an upper cervical fracture. INTERVENTIONS: Percutaneous atlantoaxial anterior transarticular screw fixation combined with limited exposure posterior C1/2 wire fusion. OUTCOME MEASURES: Computed tomography scans were used to assess the high-riding vertebral artery and feasibility of anterior transarticular screw fixation preoperatively. A Philadelphia collar was used to immobilize the neck postoperatively. Anteroposterior (open-mouth) and lateral views were obtained at pre/postoperation and at the follow-up. RESULTS: The operation was performed successfully on all of the patients, and no intraoperative operation-related complications such as nerve injury, vertebral artery, and soft tissue complications occurred. The mean follow-up period was 33.8 months (range: 24 to 58 months). No screw breakage, loosening, pullout, or cutout was observed. Bone union was achieved in all patients at the last follow-up. CONCLUSIONS: Our small case series results suggested that percutaneous anterior transarticular screw fixation combined with mini-open posterior C1/2 wire fusion is a technically minimally invasive, safe, feasible, and useful method to treat patients with a high-riding vertebral artery.


Assuntos
Articulação Atlantoaxial/cirurgia , Parafusos Ósseos/efeitos adversos , Fraturas da Coluna Vertebral/cirurgia , Fusão Vertebral/métodos , Cirurgia Assistida por Computador/métodos , Artéria Vertebral/patologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Traumatismos dos Nervos Periféricos/etiologia , Complicações Pós-Operatórias , Fusão Vertebral/efeitos adversos , Cirurgia Assistida por Computador/efeitos adversos
14.
PLoS One ; 11(2): e0148610, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26866593

RESUMO

BACKGROUND CONTEXT: Animals are commonly used to model the human spine for in vitro and in vivo experiments. Many studies have investigated similarities and differences between animals and humans in the lumbar and thoracic vertebrae. However, a quantitative anatomic comparison of calf, pig, and human cervical spines has not been reported. PURPOSE: To compare fundamental structural similarities and differences in vertebral bodies from the cervical spines of commonly used experimental animal models and humans. STUDY DESIGN: Anatomical morphometric analysis was performed on cervical vertebra specimens harvested from humans and two common large animals (i.e., calves and pigs). METHODS: Multiple morphometric parameters were directly measured from cervical spine specimens of twelve pigs, twelve calves and twelve human adult cadavers. The following anatomical parameters were measured: vertebral body width (VBW), vertebral body depth (VBD), vertebral body height (VBH), spinal canal width (SCW), spinal canal depth (SCD), pedicle width (PW), pedicle depth (PD), pedicle inclination (PI), dens width (DW), dens depth (DD), total vertebral width (TVW), and total vertebral depth (TVD). RESULTS: The atlantoaxial (C1-2) joint in pigs is similar to that in humans and could serve as a human substitute. The pig cervical spine is highly similar to the human cervical spine, except for two large transverse processes in the anterior regions ofC4-C6. The width and depth of the calf odontoid process were larger than those in humans. VBW and VBD of calf cervical vertebrae were larger than those in humans, but the spinal canal was smaller. Calf C7 was relatively similar to human C7, thus, it may be a good substitute. CONCLUSION: Pig cervical vertebrae were more suitable human substitutions than calf cervical vertebrae, especially with respect to C1, C2, and C7. The biomechanical properties of nerve vascular anatomy and various segment functions in pig and calf cervical vertebrae must be considered when selecting an animal model for research on the spine.


Assuntos
Vértebras Cervicais/anatomia & histologia , Animais , Fenômenos Biomecânicos , Cadáver , Bovinos , Humanos , Modelos Anatômicos , Modelos Animais , Canal Medular/anatomia & histologia , Coluna Vertebral/anatomia & histologia , Sus scrofa
15.
Spine J ; 15(5): 1141-5, 2015 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-25681228

RESUMO

BACKGROUND CONTEXT: Surgical stabilization is recommended for odontoid fractures with mechanical instability. Compared with C1-C2 fusion, percutaneous anterior odontoid screw fixation has the advantages of preserving C1/C2 motion and being a minimally invasive procedure. However, determining the optimal screw trajectory is often difficult. When an initial suboptimal K-wire hole is drilled, it is especially difficult to drill a second optimal K-wire trajectory because the initial hole will be entered inadvertently. PURPOSE: To design a novel device, two-hole guide tube, to make drilling a second optimal K-wire trajectory easier, and thus, avoid unnecessary additional surgical time and reduce the likelihood of needing to change the procedure to traditional open surgery. STUDY DESIGN: A technical report. METHODS: Fifty-three patients with odontoid fractures were treated by percutaneous anterior odontoid screw fixation in our hospital, and the initial K-wire trajectories of 16 cases (12 men and 4 women) among the 53 patients were imperfect. The two-hole guide tube was applied for drilling the second trajectory in each of these 16 cases. RESULTS: No complications associated with this technique occurred. Satisfactory results and good screw placement was achieved in all patients. Radiographic fusion was confirmed for 15 of 16 patients. None of the patients experienced clinical symptoms or screw loosening or breakage in this study. CONCLUSIONS: Our novel device, two-hole guide tube, can be used to reduce the difficulty associated with redrilling an optimal K-wire trajectory if the initial trajectory is imperfect during percutaneous anterior odontoid screw fixation. Moreover, by referring to the initial misplaced K-wire, a more accurate trajectory for the second K-wire can be achieved.


Assuntos
Parafusos Ósseos , Fios Ortopédicos , Processo Odontoide/cirurgia , Procedimentos Ortopédicos/métodos , Fraturas da Coluna Vertebral/cirurgia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Ortopédicos/instrumentação
16.
Zhonghua Wai Ke Za Zhi ; 42(8): 469-73, 2004 Apr 22.
Artigo em Zh | MEDLINE | ID: mdl-15144641

RESUMO

OBJECTIVE: Creating the method of transcutaneous anterior lateral mass fixation for instability of C(1,2). METHODS: The regular and safe angle and the distance between the median margin of vertebral artery and median line of superior and inferior margin of axis were measured with computerized tomography. Fifteen cases of C(1,2) instability including 7 cases atlanto-axial dislocation, 3 cases of Jefferson's fracture, 1 case of dental fracture and dislocation and 4 cases of fractures of anterior arch of C1 were treated with pertacuneous anterior lateral mass screws and bone grafting with new-designed hole instrumentations according to the measurement of 40 normal atlanto-axial vertebrae. RESULTS: In posterior-anterior ray the regular angle was 24.0 degrees +/- 3.7 degrees (right side), and 23.8 degrees +/- 1.8 degrees (left side); safe angle is 15.2 degrees - 30.3 degrees (left side) and 14.8 degrees - 32.1 degrees (right side), respectively. The distance between the median margin of vertebral artery and median line of superior and inferior margin of vertebral artery and median line of superior and inferior margin of lateral mass was (5.6 +/- 2.2) mm (right) and (5.8 +/- 1.9) mm (left). In lateral ray the regular angle was 24.1 degrees +/- 1.8 degrees, and safe angle 12.6 degrees - 26.8 degrees. All cases reach a satisfactory result of fixation without the injury of vertebral artery, spinal cord and esophagus. The acupuncture point recovers without infection. CONCLUSIONS: This operation procedure for instability of C(1,2) has the advantage of less trauma and bleeding, simply operation and bone grafting at the same time. The operation procedure is safe with reasonable instrument and selecting the correct puncture point, angle and depth.


Assuntos
Articulação Atlantoaxial/cirurgia , Instabilidade Articular/cirurgia , Fusão Vertebral/métodos , Adulto , Idoso , Articulação Atlantoaxial/diagnóstico por imagem , Parafusos Ósseos , Transplante Ósseo , Vértebras Cervicais/lesões , Feminino , Humanos , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/etiologia , Masculino , Pessoa de Meia-Idade , Radiografia , Traumatismos da Coluna Vertebral/complicações
17.
Spine (Phila Pa 1976) ; 39(3): E147-52, 2014 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-24173015

RESUMO

STUDY DESIGN: This study is a computed tomographic (CT)-based morphometric analysis of the pediatric occipital condyles as related to occipital condyle screw placement. OBJECTIVE: To quantify reference data concerning the dimensions of the immature occipital condyles to guide the placement of occipital condyle screw. SUMMARY OF BACKGROUND DATA: To the best of our knowledge, no published study has provided insight into the anatomy of occipital condyle of the pediatric population with different age groups. METHODS: Sixty-nine pediatric patients were divided into 4 age groups, and their occipital condyles were studied on CT scans. Condylar length, width, height, sagittal angle, and sagittal angle lengths were measured on Philips Brilliance 16 CT. RESULTS: The mean pediatric coronal height, sagittal length, and axial width noted statistically significant age-related differences were 9.0 mm, 21.3 mm, and 9.8 mm, respectively. The mean sagittal angle for all patients was 27.2 ± 5.1° (range, 15.1-41.0°). In 82.6% (114/138) of the occipital condyles, the anatomy could accept the occipital condyle screw (width ≥8 mm and height ≥6.5 mm). CONCLUSION: Our investigation provides insight into the anatomy of occipital condyle of the pediatric population with different age groups. As the pediatric occipital condyles have sufficient occipital bone for appropriate fixation or fusion, the occipital condyle screws fixation is a feasible technique for children. Even so, given the evolution of this technique being still in its infancy and the complexity inherent to the craniovertebral junction, a careful radiological analysis of occipital condyle must be required in preoperative planning and feasibility determination. LEVEL OF EVIDENCE: N/A.


Assuntos
Parafusos Ósseos , Côndilo Mandibular/diagnóstico por imagem , Osso Occipital/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Côndilo Mandibular/cirurgia , Osso Occipital/cirurgia , Estudos Retrospectivos
18.
PLoS One ; 9(7): e103065, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25058011

RESUMO

BACKGROUND: Anterior odontoid screw fixation (AOSF) has been one of the most popular treatments for odontoid fractures. However, the true efficacy of AOSF remains unclear. In this study, we aimed to provide the pooled rates of non-union, reoperation, infection, and approach related complications after AOSF for odontoid fractures. METHODS: We searched studies that discussed complications after AOSF for type II or type III odontoid fractures. A proportion meta-analysis was done and potential sources of heterogeneity were explored by meta-regression analysis. RESULTS: Of 972 references initially identified, 63 were eligible for inclusion. 54 studies provided data regarding non-union. The pooled non-union rate was 10% (95% CI: 7%-3%). 48 citations provided re-operation information with a pooled proportion of 5% (95% CI: 3%-7%). Infection was described in 20 studies with an overall rate of 0.2% (95% CI: 0%-1.2%). The main approach related complication is postoperative dysphagia with a pooled rate of 10% (95% CI: 4%-17%). Proportions for the other approach related complications such as postoperative hoarseness (1.2%, 95% CI: 0%-3.7%), esophageal/retropharyngeal injury (0%, 95% CI: 0%-1.1%), wound hematomas (0.2%, 95% CI: 0%-1.8%), and spinal cord injury (0%, 95% CI: 0%-0.2%) were very low. Significant heterogeneities were detected when we combined the rates of non-union, re-operation, and dysphagia. Multivariate meta-regression analysis showed that old age was significantly predictive of non-union. Subgroup comparisons showed significant higher non-union rates in age ≥ 70 than that in age ≤ 40 and in age 40 to <50. Meta-regression analysis did not reveal any examined variables influencing the re-operation rate. Meta-regression analysis showed age had a significant effect on the dysphagia rate. CONCLUSIONS/SIGNIFICANCES: This study summarized the rates of non-union, reoperation, infection, and approach related complications after AOSF for odontoid fractures. Elderly patients were more likely to experience non-union and dysphagia.


Assuntos
Transtornos de Deglutição/fisiopatologia , Fixação Interna de Fraturas/efeitos adversos , Fraturas não Consolidadas/cirurgia , Fraturas Maxilomandibulares/cirurgia , Osteíte/fisiopatologia , Complicações Pós-Operatórias , Adulto , Fatores Etários , Idoso , Parafusos Ósseos , Transtornos de Deglutição/etiologia , Feminino , Fixação Interna de Fraturas/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Osteíte/etiologia , Reoperação/estatística & dados numéricos , Resultado do Tratamento
19.
Zhongguo Gu Shang ; 24(3): 227-30, 2011 Mar.
Artigo em Zh | MEDLINE | ID: mdl-21485573

RESUMO

OBJECTIVE: To explore the efficacy of anterior percutaneous screw fixation in the treatment of odontoid process fractures in aged people. METHODS: From February 2001 to April 2009, 15 elderly patients with odontoid fracture were treated with anterior percutaneous screw fixation,including 13 males and 2 females; the average age was 69.3 years (ranged, 60 to 86 years). According to Anderson classification, there were 10 patients with type II fractures (type II A in 7 cases, type II B in 3 cases, based on Eysel and Roosen classification), 4 patients with shallow type III fractures, 1 patient with deep type III fractures. Thirteen patients were fresh fractures, 2 patients were obsolete fractures. All patients had varying degrees of neck or shoulder pain, and limit activity of neck. There were 4 patients with neural symptoms including 2 grade D and 2 grade C according to Frankel classification. All the patients were followed up and were assessed by radiology. Clinical examination included neck activity, neurological function and the degree of neck pain. Radiology examinations including anteroposterior, lateral, open mouth position and flexion-extension radiographs of cervical vertebra were performed. RESULTS: After surgery, all patients were followed up,and the duration ranged from 6 to 60 months (averaged 31.3 months). Two patients died of other diseases during the follow-up period (18 and 22 months after surgery respectively). All patients got satisfactory results, and all screws were in good position. As the screw was too long, esophagus was compressed by screw tail in one case. One case showed fibrous union, 12 cases had achieved solid bony union, 2 cases showed nonunion without clinical symptoms. The rotation of neck in 3 cases was mildly limited,the neck function of the remaining patients were normal. Four patients with symptoms nerve injuries improved after operation (Frankel E in 3 cases, Frankel D in 1 case). The symptom of neck pain had a significant improvement after surgery (P < 0.001). The VAS score decreased from preoperative (6.07 +/- 1.44) (4 to 8 scores),to postoperative (1.13 +/- 0.92) (0 to 3 scores). And there were no severe postoperative complications. CONCLUSION: The anterior percutaneous screw fixation is less traumatic than conventional approaches for aged people in dealing with odontoid process fractures. Most patients will achieve satisfactory clinical results, as long as the general conditions of them are comprehensively assess. However, this procedure should not be used in patients with comminuted odontoid fractures or severe osteoporosis.


Assuntos
Parafusos Ósseos , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Processo Odontoide/lesões , Pele , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Processo Odontoide/diagnóstico por imagem , Processo Odontoide/fisiopatologia , Processo Odontoide/cirurgia , Tomografia Computadorizada por Raios X
20.
Zhongguo Gu Shang ; 21(4): 279-81, 2008 Apr.
Artigo em Zh | MEDLINE | ID: mdl-19102189

RESUMO

OBJECTIVE: To investigate the biomechanical effect of anterior screw fixation on the type II fractured odontoid process. METHODS: Twenty fresh human C1-C2 vertebrae specimens were harvested and randomly divided into three groups. The angle of type II fracture line was 0 degree in group I (n=6), 17 degrees in group II (n=8) and 25 degrees in group III (n=6). The fractures were treated by anterior screw fixation. Insertion torque,maximal axial pullout force and stiffness of the bone-screw were tested. RESULTS: There was no significant difference of screw insertion torque and the pull-out strength between each group. The displacement of the odontoid fragment had an association to the angle of the fracture line,the displacement of the small angle was significantly higher than that of the large one (P < 0.5). No significant difference of structure stiffness of the bone-screw was found between each group. CONCLUSION: Anterior screw fixation is feasible for type II odontoid fracture with certain fracture line extends from anteroinferior to posterosuperior.


Assuntos
Parafusos Ósseos , Vértebras Cervicais/lesões , Fixação Interna de Fraturas/métodos , Fraturas da Coluna Vertebral/cirurgia , Fenômenos Biomecânicos , Humanos , Fraturas da Coluna Vertebral/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA