Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Int J Comput Dent ; 25(1): 57-70, 2022 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-35322653

RESUMO

AIM: The aim of the present study was to review the current development status of additive manufacturing (AM) technology for fabricating frameworks for removable partial dentures (RPDs) considering fit accuracy, surface condition, and mechanical strength. METHODS: A search of the databases of MEDLINE, Cochrane Library, and Science Direct was conducted using definite keywords ("removable partial denture" or "framework" or "dental prosthesis design") and ("additive manufacturing technology" or "rapid prototyping" or "3D-printing"). RESULT: A total of 23 articles were selected according to certain inclusion criteria. The direct AM techniques were applied to manufacture metal RPD frameworks consisting of selective laser melting (SLM), selective laser sintering (SLS), and metal binder jetting (MBJ). The SLM technique showed a good surface and mechanical strength, but low accuracy. The SLS technique showed higher accuracy than indirect AM, but further studies are required. The MBJ technique showed lower accuracy and a rougher surface than the conventional method. CONCLUSION: AM techniques can produce RPD frameworks within the acceptable range for clinical practice; however, more clinical studies are needed.


Assuntos
Prótese Parcial Removível , Humanos , Lasers , Impressão Tridimensional
2.
Clin Oral Implants Res ; 25(11): 1307-1310, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25279692

RESUMO

OBJECTIVE: The purpose of this systematic review was to survey evidence pertaining to the sensation differences between natural teeth and osseointegrated dental implants. MATERIAL AND METHODS: Using the MEDLINE (online PubMed) database, Cochrane Library, and Scientific Citation index, we performed a systematic search of articles. We used the following search terms: "perception or sensation and dental implant." The systematic review of the extracted articles was performed to see the sensation differences between natural teeth and dental implants. RESULTS: A total of six studies on oral sensation, "tactile sensibility," and "thickness discrimination" were included in the meta-analysis. As to the "tactile sensibility", all studies indicated the threshold levels of the implants were about 4-20 times higher than that of natural teeth. The tactile sensibility of an implant was significantly higher than that of a natural tooth, with an standardized mean difference (SMD) of 8.3619 (95% CI, 6.3920-10.3317) and a P < 0.0001. As to the "thickness discrimination", all studies indicated the threshold levels of implants were about 1.2-2.3 times higher than that of natural teeth. The thickness discrimination was significantly higher than that of natural teeth with an SMD of 1.2368 (95% CI, 0.8699-1.6038) and a P < 0.0001. CONCLUSION: This meta-analysis suggested that both tactile sensibility and thickness discrimination thresholds of implants were significantly higher than those of natural teeth. This meta-analysis reconfirms that sensation differences between dental implants and natural teeth exist.


Assuntos
Implantes Dentários , Sensação/fisiologia , Dente/fisiologia , Humanos , Osseointegração/fisiologia , Limiar Sensorial/fisiologia , Estereognose/fisiologia , Tato/fisiologia
3.
Dent J (Basel) ; 11(3)2023 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-36975559

RESUMO

BACKGROUND: Robotics is progressing rapidly. The aim of this study was to provide a comprehensive overview of the basic and applied research status of robotics in dentistry and discusses its development and application prospects in several major professional fields of dentistry. METHODS: A literature search was conducted on databases: MEDLINE, IEEE and Cochrane Library, using MeSH terms: ["robotics" and "dentistry"]. RESULT: Forty-nine articles were eventually selected according to certain inclusion criteria. There were 12 studies on prosthodontics, reaching 24%; 11 studies were on dental implantology, accounting for 23%. Scholars from China published the most articles, followed by Japan and the United States. The number of articles published between 2011 and 2015 was the largest. CONCLUSIONS: With the advancement of science and technology, the applications of robots in dental medicine has promoted the development of intelligent, precise, and minimally invasive dental treatments. Currently, robots are used in basic and applied research in various specialized fields of dentistry. Automatic tooth-crown-preparation robots, tooth-arrangement robots, drilling robots, and orthodontic archwire-bending robots that meet clinical requirements have been developed. We believe that in the near future, robots will change the existing dental treatment model and guide new directions for further development.

4.
J Prosthodont Res ; 67(3): 384-391, 2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-36288959

RESUMO

PURPOSE: We aimed to evaluate the effectiveness of photoreactive 2-methacryloyloxyethyl phosphorylcholine (MPC) in inhibiting Candida albicans biofilm formation on polymethyl methacrylate (PMMA) and assess its mechanism and need for re-application by evaluating its interaction with salivary mucin and durability during temperature changes. METHODS: PMMA discs were used as specimens. The MPC coating was applied using the spray and cure technique for the treatment groups, whereas no coating was applied to the control. The MPC treatment (MT) groups were further differentiated based on the number of thermal cycles involved (0, 1000, 2500, and 5000). The optical density was measured to assess mucin adsorption (MA). Contact angle (CA) was calculated to evaluate surface hydrophilicity. The presence of MPC components on the PMMA surface was assessed using X-ray photoelectron spectroscopy (XPS). C. albicans biofilms were evaluated qualitatively (scanning electron microscope images) and quantitatively (colony-forming units (CFUs)). Statistical analysis was conducted using two-way analysis of variance and Tukey's multiple comparison test. RESULTS: MA rate and CA increased significantly in the MT groups, which exhibited significantly fewer CFUs and thinner biofilms than those of the control group. Based on the XPS, MA, and CFU evaluations, the durability and efficacy of the MPC coating were considered stable up to 2500 thermal cycles. Additionally, a significant interaction was observed between mucin concentration and MPC efficacy. CONCLUSIONS: The photoreactive MPC coating, which was resistant to temperature changes for approximately 3 months, effectively prevented C. albicans biofilm formation by modifying surface hydrophilicity and increasing mucin adsorption.


Assuntos
Resinas Acrílicas , Candida albicans , Resinas Acrílicas/química , Polímeros , Polimetil Metacrilato/farmacologia , Polimetil Metacrilato/química , Propriedades de Superfície , Biofilmes , Mucinas
5.
Commun Biol ; 5(1): 671, 2022 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-35798870

RESUMO

Metal allergy is one of the typical immune disorders encountered during the application of dental/medical materials and has a highly complex pathogenic mechanism. Semaphorin 3A (Sema3A), a member of the semaphorin family, is reported to be involved in various immune disorders. However, its role in metal allergy has not been clarified yet. Herein, we show that Sema3A expression was upregulated in nickel (Ni) allergy-induced mouse ear tissue and in NiCl2-stimulated mouse keratinocytes. Moreover, Sema3A regulated tumor necrosis factor-alpha production and mitogen-activated protein kinase activation in keratinocytes. The specific deletion of Sema3A in keratinocytes did not affect immune cell infiltration but reduced edema and ear swelling; it also impeded Th1 responses to cause a slight alleviation in Ni allergy in mice. Our results demonstrate that Sema3A promotes the development of metal allergy and should be explored as a potential target for the prevention and treatment of metal allergy.


Assuntos
Hipersensibilidade , Níquel , Semaforina-3A , Animais , Hipersensibilidade/prevenção & controle , Queratinócitos/metabolismo , Camundongos , Níquel/toxicidade , Semaforina-3A/genética , Semaforina-3A/metabolismo
6.
Dent J (Basel) ; 10(5)2022 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-35621528

RESUMO

Recently, a novel magnetic attachment with extremely low cost and high performance was developed. This article aims to introduce a novel magnetic attachment and to evaluate its basic eligibility for denture retention in clinical practice. The novel magnetic attachment system used in this study was the direct-bonding root-keeper-type Magteeth™ MT800 (MagneDesign, Nagoya, Japan). The retentive force without displacement (position 0) and after horizontal displacement to positions 0.5, 1, 1.5, 2, 2.5, and 3 mm were measured. The values relative to the retentive force without displacement were gradually decreased to 82.7 ± 16.3%, 68.8 ± 17.1%, 62.4 ± 15%, 47.2 ± 13.1%, 35.7 ± 9.9%, and 20.7 ± 6.5%, respectively. The retentive force and magnetic field strength did not change significantly after the load test (100 N load, 10,000 times). No new gap between the metal and resin was found in the root keeper- and magnet assembly-embedded blocks after the load test. Some scratches on magnetic assembly and root keeper surface, while no change in the resin texture after the load test were observed. Based on the findings of this preliminary study, this novel low-cost magnetic attachment exhibited favorable retention, strength, and durability for clinical use.

7.
Int J Implant Dent ; 7(1): 111, 2021 11 13.
Artigo em Inglês | MEDLINE | ID: mdl-34773513

RESUMO

BACKGROUND: Implant-assisted removable partial dentures (IARPDs) have recently become popular, but little information is available on the treatment outcomes based on the Kennedy classification and attachment types. OBJECTIVE: The objective of this review was to evaluate the treatment outcomes of IARPD delivered for distal extension edentulous areas based on the differences in the Kennedy classification and attachment type. MATERIALS AND METHODS: English-language clinical studies on IARPD published between January 1980 and February 2020 were collected from MEDLINE (via PubMed), the Cochrane Library (via the Cochrane Central Register of Controlled Trials), Scopus online database, and manual searching. Two reviewers selected the articles based on pre-determined inclusion and exclusion criteria, followed by data extraction and analysis. RESULTS: Eighty-one studies were selected after evaluating the titles and abstracts of 2410 papers. Nineteen studies were finally included after the perusal of the full text. Fourteen studies focused on Class I, 4 studies investigated both Class I and II, and only 1 study was conducted on Kennedy's class II. Eight types of attachments were reported. The ball attachment was the most frequently used attachment, which was employed in 8 of the included studies. The implant survival rate ranged from 91 to 100%. The reported marginal bone loss ranged from 0.3 mm to 2.30 mm. The patient satisfaction was higher with IARPD than with conventional RPDs or that before treatment. The results of prosthetic complications were heterogeneous and inconclusive. CONCLUSION: IARPD exhibited favorable clinical outcomes when used as a replacement for distal extension edentulous areas. The comparison between the clinical outcomes of Kennedy's class I and II was inconclusive owing to the lack of studies focusing on Kennedy Class II alone. The stud attachment was the most commonly used type in IARPDs. Overall, the different attachment systems did not influence the implant survival rate and patient satisfaction. Further high-quality studies are needed to investigate the attachment systems used in IARPD.


Assuntos
Implantes Dentários , Prótese Parcial Removível , Prótese Dentária Fixada por Implante , Humanos , Satisfação do Paciente , Resultado do Tratamento
8.
J Prosthodont ; 17(6): 487-9, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18544129

RESUMO

This article discusses two methods for improving the retrievability of cement-retained implant superstructures. One method involves incorporating a removal screw in the superstructure and the second method uses a small dimple on the abutment, accessed through a vent in the superstructure.


Assuntos
Cimentos Dentários/química , Descolagem Dentária/métodos , Implantes Dentários , Retenção em Prótese Dentária , Prótese Dentária Fixada por Implante , Coroas , Dente Suporte , Descolagem Dentária/instrumentação , Planejamento de Prótese Dentária , Humanos , Propriedades de Superfície
9.
Dent J (Basel) ; 5(4)2017 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-29563441

RESUMO

Polyetheretherketone (PEEK) is a semi-crystalline linear polycyclic thermoplastic that has been proposed as a substitute for metals in biomaterials. PEEK can also be applied to dental implant materials as a superstructure, implant abutment, or implant body. This article summarizes the current research on PEEK applications in dental implants, especially for the improvement of PEEK surface and body modifications. Although various benchmark reports on the reinforcement and surface modifications of PEEK are available, few clinical trials using PEEK for dental implant bodies have been published. Controlled clinical trials, especially for the use of PEEK in implant abutment and implant bodies, are necessary.

10.
J Texture Stud ; 48(2): 171-177, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28370114

RESUMO

The purpose of this study was to survey the changes that occur in bolus texture from intake to swallowing during the mastication process for four types of food materials and to identify how texture is related to the number of chews. We recruited 15 young Japanese participants for this study. The subjects were asked to spit the food bolus just before swallowing when eating four different foods: cracker, boiled rice, hard gelatine gel, and soft gelatine gel. Three physical properties (hardness, adhesiveness, and cohesiveness) were measured in the bolus after being chewed for 25, 50, 75, 100, and 125% of the normal number of chews. Occlusal force and pressure as well as stimulated whole saliva volume were also measured. Extensive variation in the number of chews existed between subjects, but minimal intra-subject variation was observed. Hardness was observed to decrease, whereas cohesiveness and adhesiveness increased in a chew-dependent manner for the cracker, soft gelatine gel, and hard gelatine gel, but not boiled rice. Bolus texture appears to be largely related to the number of chews. Hardness also tended to be influenced by occlusion. The adhesiveness and hardness of the boiled rice were also greatly influenced by saliva volume and occlusal force, respectively. Hardness is an important rheological factor in food bolus texture and likely plays a significant role in determining the appropriate number of chews. Adhesiveness and cohesiveness appear to be secondary factors in this process. PRACTICAL APPLICATIONS: We propose a model of oral processing for application in determining the appropriate number of chews for an individual. Hardness appears to be an important rheological factor in food bolus texture, with adhesiveness and cohesiveness being secondary aspects. When food is hard or difficult to swallow, chewing behavior will likely be more influenced by the perception of bolus texture.


Assuntos
Deglutição/fisiologia , Ingestão de Alimentos/fisiologia , Comportamento Alimentar/fisiologia , Alimentos , Mastigação/fisiologia , Adesividade , Adulto , Povo Asiático , Fenômenos Biomecânicos , Força de Mordida , Feminino , Géis , Dureza , Humanos , Masculino , Oryza , Reologia , Saliva , Inquéritos e Questionários , Fatores de Tempo , Adulto Jovem
11.
J Prosthodont Res ; 60(3): 206-12, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26822762

RESUMO

PURPOSE: The aim of this study was to compare 3-dimensional surfaces of study and working casts for edentulous jaws and to evaluate the accuracy of preliminary impressions with a view to the future application of digital dentistry for edentulous jaws. METHODS: Forty edentulous volunteers were serially recruited. Nine dentists took preliminary and final impressions in a routine clinical work-up. The study and working casts were digitized using a dental 3-dimensional scanner. The two surface images were superimposed through a least-square algorithm using imaging software and compared qualitatively. Furthermore, the surface of each jaw was divided into 6 sections, and the difference between the 2 images was quantitatively evaluated. RESULTS: Overall inspection showed that the difference around residual ridges was small and that around borders were large. The mean differences in the upper and lower jaws were 0.26mm and 0.45mm, respectively. The maximum values of the differences showed that the upward change mainly occurred in the anterior residual ridge, and the downward change mainly in the posterior border seal, and the labial and buccal vestibules, whereas every border of final impression was shortened in the lower jaw. The accuracy in all areas except the border, which forms the foundation, was estimated to be less than 0.25mm. CONCLUSION: Using digital technology, we here showed the overall and sectional accuracy of the preliminary impression for edentulous jaws. In our clinic, preliminary impressions have been made using an alginate material while ensuring that the requisite impression area was covered.


Assuntos
Revestimento para Fundição Odontológica , Técnica de Moldagem Odontológica , Imageamento Tridimensional , Arcada Edêntula , Idoso , Idoso de 80 Anos ou mais , Humanos , Software
12.
Dent J (Basel) ; 4(4)2016 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-29563476

RESUMO

The mechanical properties of seven denture adhesives and eight oral moisturizers, all of which are commercially available, were evaluated using a texture profile analysis. A new assessment chart is proposed for the selection criteria of denture adhesive and oral moisturizers using a radar chart with three axes: hardness, cohesiveness, and adhesiveness.

13.
Dent J (Basel) ; 4(4)2016 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-29563477

RESUMO

Two-implant overdentures have become the accepted treatment for restoring mandibular edentulism. The dimensions of regular implants sometimes limit their use, such as in the case of narrow ridges. Mini-implants with reduced diameters (less than 3.0 mm) enable insertion into narrow ridges. A magnet-retained two-mini-implant overdenture system was developed and is described in this paper. Additionally, we describe a clinical mandibular procedure using the system and evaluate its biomechanical performance.

14.
PLoS One ; 8(12): e84327, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24358355

RESUMO

BACKGROUND: Many studies on surface modifications of titanium have been performed in an attempt to accelerate osseointegration. Recently, anatase titanium dioxide has been found to act as a photocatalyst that expresses antibiotic properties and exhibits hydrophilicity after ultraviolet exposure. A blue-violet semiconductor laser (BV-LD) has been developed as near-ultraviolet light. The purpose of this study was to investigate the effects of exposure to this BV-LD on surface modifications of titanium with the goal of enhancing osteoconductive and antibacterial properties. METHODS: The surfaces of pure commercial titanium were polished with #800 waterproof polishing papers and were treated with anatase titania solution. Specimens were exposed using BV-LD (λ = 405 nm) or an ultraviolet light-emitting diode (UV-LED, λ = 365 nm) at 6 mW/cm(2) for 3 h. The surface modification was evaluated physically and biologically using the following parameters or tests: surface roughness, surface temperature during exposure, X-ray diffraction (XRD) analysis, contact angle, methylene blue degradation tests, adherence of Porphyromonas gingivalis, osteoblast and fibroblast proliferation, and histological examination after implantation in rats. RESULTS: No significant changes were found in the surface roughness or XRD profiles after exposure. BV-LD exposure did not raise the surface temperature of titanium. The contact angle was significantly decreased, and methylene blue was significantly degraded. The number of attached P. gingivalis organisms was significantly reduced after BV-LD exposure compared to that in the no exposure group. New bone was observed around exposed specimens in the histological evaluation, and both the bone-to-specimen contact ratio and the new bone area increased significantly in exposed groups. CONCLUSIONS: This study suggested that exposure of titanium to BV-LD can enhance the osteoconductivity of the titanium surface and induce antibacterial properties, similar to the properties observed following exposure to UV-LED.


Assuntos
Antibacterianos , Lasers , Osseointegração , Titânio/química , Animais , Aderência Bacteriana/efeitos da radiação , Masculino , Camundongos , Ratos , Propriedades de Superfície , Titânio/efeitos da radiação
15.
J Prosthodont Res ; 55(3): 141-5, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21300587

RESUMO

PURPOSE: The purpose of this retrospective study was to assess the implant survival rate and the risk factors associated with implant failure in patients who had undergone immediate implant restoration. MATERIALS AND METHODS: We performed a retrospective review and an outcome assessment of all patients who received immediate implant restoration between 2000 and 2010 in our department at Tokushima University Hospital. The patients were divided into groups on the basis of the predictor variables: age, gender, implant location, and number of implants per jaw. The cumulative implant survival rate in the paired groups was determined by using Kaplan-Meier analysis and the log-rank test. Cox proportional hazards model was subsequently used to identify exposures associated with implant failure. RESULTS: Using the Kaplan-Meier method, the survival rates at 1, 3, and 9 years were calculated to be 98.8%, 98.0%, and 94.7%, respectively. No statistically significant association was observed between the implant survival rates and the predictor variables: gender, age, location, and number of implants. CONCLUSIONS: Immediate implant restoration is a reliable prosthetic procedure with an acceptable survival rate compared to the conventional implant procedure.


Assuntos
Implantes Dentários , Adulto , Idoso , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Falha de Prótese , Estudos Retrospectivos , Fatores de Tempo
16.
Int J Oral Maxillofac Implants ; 26(3): 657-64, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21691614

RESUMO

PURPOSE: Retrievability, connecting strength, and ease of laboratory work are important but conflicting prerequisites for the success of an implant superstructure, particularly with regard to immediate function. To resolve this issue, a telescopic magnetic attachment system has been developed for implant-supported removable dentures. The splinting effect of the attachment was evaluated for stress distribution and elevation with an in vitro model of three implants in an edentulous mandible. MATERIALS AND METHODS: Two types of telescopic magnetic attachments were prepared; the inclination angles of the axial wall of the abutment were 2.5 and 6.0 degrees. Three types of three-unit superstructures--a screw-retained superstructure and two telescopic magnet-retained superstructures--were fabricated. Static loads of 24.5, 49, and 98 N were applied vertically at three loading points on one side of each occlusal table. The elevation was measured as the height at which the magnet-retained superstructure detached from the abutment (on the other side of the prosthesis). In addition, by means of strain gauges, the stress distribution around the implants was evaluated and compared among the superstructures with the same three loads applied at six different points. RESULTS: The magnet-retained superstructure with the axial wall inclined at 2.5 degrees did not detach from the abutment. The differences in stress distribution between the screw-retained and magnet-retained superstructures with a 2.5-degree inclination were found to be statistically insignificant. The magnet-retained superstructure with a 6-degree inclination detached from the abutment, and the stress was concentrated during loading to a cantilever site. CONCLUSION: Because of its stress distribution and elevation, the new telescopic magnetic attachment, which has properties such as splinting the implants, ease of fabrication, and retrievability, is expected to be a viable alternative for the retention of implant-supported removable dentures.


Assuntos
Grampos Dentários , Implantação Dentária Endóssea/instrumentação , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Retenção de Dentadura/instrumentação , Dente Suporte , Implantação Dentária Endóssea/métodos , Implantes Dentários , Análise do Estresse Dentário , Humanos , Magnetismo , Mandíbula , Teste de Materiais , Modelos Dentários , Estatísticas não Paramétricas , Estresse Mecânico , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA