Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Eur Heart J ; 41(27): 2541-2552, 2020 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-31989155

RESUMO

AIMS: Drug-coated balloons (DCBs) for femoropopliteal interventions have not been tested against each other. We aimed to directly compare efficacy and safety of a high-dose (In.Pact™) vs. low-dose (Ranger™) DCB with nominal paclitaxel densities of 3.5 vs. 2.0 µg/mm2. METHODS AND RESULTS: Within a prospective, multicentre, non-inferiority, clinical trial 414 patients with symptomatic femoropopliteal lesions (Rutherford classification 2-4) were randomly assigned in a 1:1 ratio to endovascular treatment with either high- or low-dose DCB after stratification for lesion length. Primary efficacy and safety endpoints comprised primary patency and freedom from major adverse events (i.e. device and procedure-related deaths through 1 month, major amputations, and clinically driven target lesion revascularization through 12 months). We set a non-inferiority margin of -10% at 12 months. Total occlusions were observed frequently (>40%) and provisional stenting was performed in every fourth intervention. Non-inferiority was determined for both primary efficacy and safety endpoints at 12 months. Primary patency was 81.5% in the high-dose and 83.0% in low-dose DCB group {difference: 1.5% [lower bound of the 90% two-sided confidence interval (CI) -5.2%]; Pnon-inferiority < 0.01}. Freedom from major adverse events was determined in 92.6% in high-dose and in 91.0% in low-dose DCB group [difference -1.6% (lower bound of the 90% two-sided CI -6.5%); Pnon-inferiority < 0.01]. Overall death rate was low (2.0%) and no major amputation occurred. CONCLUSION: Two DCBs with different coating characteristics exhibited comparable results with excellent effectiveness and safety through 12 months for femoropopliteal interventions including a wide range of lesion lengths. CLINICAL TRIAL REGISTRATION: The trial is registered with ClinicalTrials.gov (NCT02701543).


Assuntos
Angioplastia com Balão , Fármacos Cardiovasculares , Doença Arterial Periférica , Preparações Farmacêuticas , Materiais Revestidos Biocompatíveis , Artéria Femoral , Humanos , Paclitaxel , Doença Arterial Periférica/terapia , Artéria Poplítea , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
2.
J Endovasc Ther ; 23(3): 409-16, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27117972

RESUMO

PURPOSE: To report a subanalysis of the German centers enrolling patients in the prospective, global, multicenter, randomized LEVANT 2 pivotal trial (ClinicalTrials.gov identifier NCT01412541) of the Lutonix drug-coated balloon (DCB) for the treatment of femoropopliteal occlusive disease. METHODS: Among the 476 patients in LEVANT 2, 126 patients (mean age 67.1±9.6 years; 79 men) were enrolled at the 8 participating German sites between August 2011 and July 2012 and were randomized 2:1 to treatment with the Lutonix DCB (n=83) vs an uncoated balloon during percutaneous transluminal angioplasty (PTA, n=43). All patients had intermittent claudication or rest pain (Rutherford categories 2-4). Average lesion length was 58 mm and average treated length was 100 mm. Severe calcification was present in 11% of lesions, and 23% were total occlusions. The efficacy outcome was primary patency at 12 months, and the safety outcome was 12-month freedom from a composite of perioperative death, index limb-related death, amputation (below or above the ankle), and index limb revascularization. Secondary endpoints included target lesion revascularization (TLR), major adverse events, and functional outcomes. RESULTS: Demographic, clinical, and lesion characteristics were matched between Lutonix DCB and PTA groups, as were the final percent diameter stenosis (19%) and procedure success (91%). By Kaplan-Meier analysis, the 12-month primary patency rate was 80% vs 58% (p=0.015) and the composite safety endpoint rate was 94% vs 72% (p=0.001), respectively. Freedom from TLR was higher for DCBs (96%) vs PTA (82%, p=0.012). Major adverse events were similar for both groups. The benefit favoring DCB over PTA was observed in German men and women. Compared to the non-German LEVANT 2 cohort, there was a shorter time between insertion and inflation of treatment balloons (21.8 vs 39.5 seconds, p<0.001) in the German cohort. Balloons were inflated to higher pressures (9.0 vs 7.7 atm, p<0.001) but for a shorter period of time (130 vs 167 seconds, p<0.001), and although treated lesions in the German cohort had a higher baseline stenosis, final postprocedure diameter stenosis was lower (19% vs 22%, p=0.04) than in the non-German patients. CONCLUSION: Superiority of DCB over PTA in the German cohort of LEVANT 2 was demonstrated for primary patency, composite safety, and freedom from TLR. The benefit of DCB was also consistent for both genders. Geographic or regional differences in procedural variables may account for the different outcomes between the German and non-German cohorts.


Assuntos
Angioplastia com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Artéria Femoral , Claudicação Intermitente/terapia , Paclitaxel/administração & dosagem , Doença Arterial Periférica/terapia , Artéria Poplítea , Dispositivos de Acesso Vascular , Idoso , Angioplastia com Balão/efeitos adversos , Constrição Patológica , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Alemanha , Humanos , Claudicação Intermitente/diagnóstico por imagem , Claudicação Intermitente/fisiopatologia , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Recidiva , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
3.
JACC Cardiovasc Interv ; 15(20): 2093-2102, 2022 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-36265942

RESUMO

BACKGROUND: So far only 1-year data have been reported for direct comparisons of paclitaxel-coated balloons (PCBs) using different coating technologies. OBJECTIVES: The aim of this study was to report the 24-month results on the efficacy and safety of low-dose vs high-dose PCBs with nominal paclitaxel densities of 2.0 and 3.5 µg/mm2 and different coating technologies for femoropopliteal interventions from the COMPARE (Compare I Pilot Study for the Treatment of Subjects With Symptomatic Femoropopliteal Artery Disease) trial. Procedural characteristics of clinically driven (CD) target lesion revascularization (TLR) were analyzed. METHODS: Within a prospective, multicenter, clinical trial, 414 patients with symptomatic femoropopliteal lesions (Rutherford categories 2-4, maximum lesion length 30 cm) were randomly assigned in a 1:1 ratio to endovascular treatment with either a low-dose (Ranger) or a high-dose (IN.PACT) PCB after stratification for lesion length. Two-year follow-up included assessment of primary patency (defined as absence of CD TLR or binary restenosis with a peak systolic velocity ratio >2.4 by duplex ultrasound), safety, and functional and clinical outcomes. RESULTS: At 2 years, the Kaplan-Meier estimates of primary patency were 70.6% and 71.4% for the low-dose and high-dose PCBs (log-rank P = 0.96), respectively. One major amputation occurred in the high-dose group, and rates of all-cause mortality (3.6% vs 2.2%; P = 0.55) and CD TLR (17.3% vs 13.0%; P = 0.31) were similar between the groups. Among a total of 57 CD TLRs, 44.6% were performed for reocclusion and 28.1% for in-stent restenosis. Functional and clinical benefits over baseline were sustained in both groups. CONCLUSIONS: The 2-year results of the COMPARE trial demonstrate a sustained treatment benefit of both low-dose and high-dose PCBs for femoropopliteal interventions including a wide range of lesion lengths. (Compare I Pilot Study for the Treatment of Subjects With Symptomatic Femoropopliteal Artery Disease; NCT02701543).


Assuntos
Angioplastia com Balão , Fármacos Cardiovasculares , Doença Arterial Periférica , Bifenilos Policlorados , Dispositivos de Acesso Vascular , Humanos , Paclitaxel/efeitos adversos , Artéria Poplítea/diagnóstico por imagem , Angioplastia com Balão/efeitos adversos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Estudos Prospectivos , Projetos Piloto , Fármacos Cardiovasculares/efeitos adversos , Materiais Revestidos Biocompatíveis , Grau de Desobstrução Vascular , Resultado do Tratamento , Fatores de Tempo , Artéria Femoral/diagnóstico por imagem , Constrição Patológica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA