Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Am J Kidney Dis ; 60(6): 966-75, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22835900

RESUMO

BACKGROUND: The benefits of biocompatible peritoneal dialysis (PD) fluids, particularly for residual renal function (RRF), are controversial. Moreover, the clinical effects of a PD regimen consisting of different biocompatible PD fluids have not been fully established. STUDY DESIGN: Prospective, randomized, controlled, open-label study. SETTING & PARTICIPANTS: Patients with end-stage kidney disease newly started on continuous ambulatory PD therapy (N = 150). INTERVENTION: A 12-month intervention with 3 biocompatible PD fluids (a neutral-pH, low glucose degradation product, 1.5% glucose solution; a solution with 1.1% amino acid; and a fluid with 7.5% icodextrin) or conventional PD fluid. OUTCOMES: The primary outcome was change in RRF and daily urine volume. Secondary outcomes were peritoneal transport and inflammation markers. MEASUREMENTS: RRF, daily urine volume, serum and dialysate cytokine levels. RESULTS: RRF(3.24 ± 1.98 vs 2.88 ± 2.43 mL/min/1.73 m(2); P = 0.9) and rate of decline in RRF (-0.76 ± 1.77 vs -0.91 ± 1.92 mL/min/1.73 m(2) per year; P = 0.6) did not differ between the biocompatible- and conventional-PD-fluid groups. However, patients using the biocompatible PD fluids had better preservation of daily urine volume (959 ± 515 vs 798 ± 615 mL/d in the conventional group, P = 0.02 by comparison of difference in overall change by repeated-measures analysis of variance). Their dialysate-plasma creatinine ratio at 4 hours was higher at 12 months (0.78 ± 0.13 vs 0.68 ± 0.12; P = 0.01 for comparison of the difference in overall change by repeated-measures analysis of variance). They also had significantly higher serum levels of adiponectin and overnight spent dialysate levels of cancer antigen 125, adiponectin, and interleukin 6 (IL-6). No differences between the 2 groups were observed for serum C-reactive protein and IL-6 levels. LIMITATIONS: Unblinded, relatively short follow-up; no formal sample-size calculations. CONCLUSIONS: Use of a combination of 3 biocompatible PD fluids for 12 months compared with conventional PD fluid did not affect RRF, but was associated with better preservation of daily urine volume. The biocompatible PD fluids also lead to changes in small-solute transport and an increase in dialysate cancer antigen 125, IL-6, adiponectin, and systemic adiponectin levels, but have no effect on systemic inflammatory response. The clinical significance of these changes, while of great interest, remains to be determined by further studies.


Assuntos
Materiais Biocompatíveis/uso terapêutico , Soluções para Diálise/uso terapêutico , Mediadores da Inflamação/sangue , Falência Renal Crônica/sangue , Falência Renal Crônica/fisiopatologia , Testes de Função Renal , Diálise Peritoneal , Adulto , Idoso , Materiais Biocompatíveis/farmacologia , Transporte Biológico Ativo/efeitos dos fármacos , Transporte Biológico Ativo/fisiologia , Biomarcadores/sangue , Soluções para Diálise/farmacologia , Feminino , Seguimentos , Humanos , Mediadores da Inflamação/fisiologia , Falência Renal Crônica/terapia , Testes de Função Renal/métodos , Masculino , Pessoa de Meia-Idade , Diálise Peritoneal/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA