Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
2.
Zhongguo Gu Shang ; 36(9): 880-3, 2023 Sep 25.
Artigo em Zh | MEDLINE | ID: mdl-37735082

RESUMO

OBJECTIVE: To analyze the effect of lag screw and support plate through axillary approach for the treatment of Ideberg typeⅡscapular pelvis fracture. METHODS: From January 2016 to June 2021, 26 patients with Ideberg typeⅡglenoid fractures were treated with trans-axillary lag screw combined with supporting plate, including 15 males and 11 females. The age ranged from 21 to 75 years, with an average of (43.12±6.56) years old. The Constant-Murley Shoulder joint Scale and University of California at Los Angeles (UCLA) score were used to evaluate the function and clinical efficacy of shoulder joint. RESULTS: All patients were followed up, and the duration ranged from 19 to 42 months, with an average of (30.6±10.5) months. One year after surgery, the Constant-Murley score increased from preoperative 34.9±2.5(ranged, from 28 to 47) to 87.2±6.8(ranged, from 70 to 95). The UCLA score improved from preoperative 17.9±1.7(9 to 25) to 33.1±2.3(29 to 35). Seventeen patients got an excellent result, with 7 good, and 2 fair. None of the patients had infection, screw, and plate loosening, fracture, and other complications after surgery. Two patients had different degrees of Chronic pain in the shoulder during the follow-up period. CONCLUSION: The treatment of Ideberg typeⅡscapular glenoid fractures through axillary approach with lag screws and supporting steel plates has the advantages of convenient exposure, direct visual restoration of the normal anatomical shape of the scapular glenoid, selection of suitable positions for screw and steel plate placement, achieving better treatment results, and fewer complications. It is an effective and reliable surgical method.


Assuntos
Fraturas Ósseas , Escápula , Feminino , Masculino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Placas Ósseas , Parafusos Ósseos , Aço , Pelve
3.
Bioorg Med Chem ; 20(4): 1380-7, 2012 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-22289175

RESUMO

Several 1,4,7,10-tetraazacyclododecane (cyclen)-based linear (3a-c) and cross-linked (8a-d) polymers containing biodegradable ester or disulfide bonds were described. These polymeric compounds were prepared by ring-opening polymerization from various diol glycidyl ethers. The molecular weights of the title polymers were measured by GPC. Agarose gel retardation assays showed that these compounds have good DNA-binding ability and can completely retard plasmid DNA (pDNA) at weight ratio of 20 for linear polymers and 1.2 for cross-linked polymers. The degradation of these polymers was confirmed by GPC. The formed polyplexes have appropriate sizes around 400 nm and zeta-potential values about 15-40 mV. The cytotoxicities of 8 assayed by MTT are much lower than that of 25 KDa PEI. In vitro transfection toward A549 and 293 cells showed that the transfection efficiency (TE) of 8c-DNA polyplex is close to that of 25 kDa PEI at 8c/DNA weight ratio of 4. Structure-activity relationships (SAR) of these linear and cross-linked polymers were discussed in their DNA-binding, cytotoxicity, and transfection studies. In addition, in the presence of serum, the TE of 8/DNA polyplexes could be improved by introducing chloroquine or Ca(2+) to pretreated cells.


Assuntos
Implantes Absorvíveis , Reagentes de Ligações Cruzadas/química , Vetores Genéticos/química , Compostos Heterocíclicos/química , Polímeros/química , Ciclamos , Humanos , Peso Molecular , Relação Estrutura-Atividade
4.
Materials (Basel) ; 15(22)2022 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-36431463

RESUMO

High temperature and strain will occur in the cutting area during dry milling of contour bevel gears, which causes plastic deformation of the workpiece, resulting in changes in the physical properties of the machined surface's metamorphic layer, reducing the quality of the workpiece's machined surface. Therefore, it is necessary to investigate the properties of the metamorphic layer and the work hardening behavior of the machined surfaces of contour bevel gears. The paper first establishes a single-tooth finite element simulation model for a contour bevel gear and extracts the temperature field, strain field and strain rate at different depths from the machined surface. Then, based on the simulation results, the experiment of milling contour bevel gears is carried out, the microscopic properties of the machined metamorphic layer are studied using XRD diffractometer and ultra-deep field microscopy, and the work hardening behavior of the machined metamorphic layer under different cutting parameters is studied. Finally, the influence of the cutting parameters on the thickness of the metamorphic layer of the machined surface is investigated by scanning electron microscopy. The research results can not only improve the surface quality and machinability of the workpiece, but are also significant for increasing the fatigue strength of the workpiece.

5.
J Mech Behav Biomed Mater ; 136: 105532, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36283298

RESUMO

Although high-speed grinding of the enamel surface is often required in restorative dentistry, the knowledge of grinding mechanics, material removal, and fracture damage mechanism related to this process is still relatively limited; therefore, it is important to perform relevant scientific and theoretical research. As per the occlusal surface and the buccal/lingual surface of the teeth, the experimental scheme of high-speed grinding of the enamel surface using a diamond grinding bur was designed, and the grinding force, force ratio, grinding temperature, chips, surface morphology, surface damage, and other important characteristics were tested and analyzed. Furthermore, the grinding geometry model, grinding mechanics, material fracture, and removal mechanism associated with the high-speed grinding of an enamel surface were considered. The results show that the grinding force, friction coefficient, grinding temperature, and surface damage achieved through buccal/lingual surface grinding are considerably greater, and the grinding quality is worse than that obtained via occlusal surface grinding under the same grinding conditions. With the increase in the feed rate, grinding force, friction coefficient, grinding temperature, and surface damage obviously increase, and the surface quality decreases. The embrittlement effect and the ironing mechanism are present during the process of high-speed grinding of enamel. Regardless of the feed rate, the three types of material fracture modes of the buccal/lingual surface are more serious than those of the occlusal surface (making it more likely to produce unstable large chips or tearing chips); moreover, the brittle fracture and damage of the final machined surface are more obvious. The cutting mechanics and cutting mechanism identified in this study will provide scientific guidance for dental grinding operations.


Assuntos
Fenômenos Mecânicos , Dente , Odontologia , Temperatura , Esmalte Dentário
6.
Zootaxa ; 5162(4): 397-409, 2022 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-36095500

RESUMO

To date, only two whip spider species have been recorded in China. We describe a new species, Sarax sinensis sp. nov., from Fujian, China. This species is morphologically similar to S. ioanniticus (Kritscher, 1959), S. israelensis (Miranda et al., 2016), and S. seychellarum (Kraepelin, 1898), but can be distinguished by the combination of the following characters: 35 segments in leg I tarsus, eight teeth on cheliceral claw, and four dorsal and ventral spines respectively on pedipalp femur. To examine the evolutionary history of S. sinensis sp. nov., we sequenced 12S, 16S, and COI gene regions of our specimens and inferred its phylogenetic position. The inferred phylogenetic trees placed the new species within Sarax, with its closest relative being distributed across the western Asia. The type specimens are deposited in the Museum of Biology, East China Normal University (ECNU).


Assuntos
Aracnídeos , Aranhas , Distribuição Animal , Animais , Tamanho Corporal , China , Humanos , Tamanho do Órgão , Filogenia , Aranhas/genética
7.
Front Neurosci ; 16: 1019989, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36248652

RESUMO

Toothache (TA) is a common and severe pain, but its effects on the brain are somewhat unclear. In this study, functional magnetic resonance imaging (fMRI) was used to compare regional homogeneity (ReHo) between TA patients and a normal control group and to explore the brain activity changes during TA, establishing the theoretical basis for the mechanism of neuropathic pain. In total, 20 TA patients and 20 healthy controls (HCs) were recruited and underwent assessment of pain, and then resting-state fMRI (rs-fMRI). The ReHo method was used to analyze the original whole-brain images. Pearson's correlation analysis was used to assess the relationship between mean ReHo values in each brain region and clinical symptoms, and the receiver operating characteristic (ROC) curve was used to conduct correlation analysis on the brain regions studied. The ReHo values of the right lingual gyrus (RLG), right superior occipital gyrus (RSOG), left middle occipital gyrus (LMOG) and right postcentral gyrus (RPG) in the TA group were significantly higher than in HCs. The mean ReHo values in the RLG were positively correlated with the anxiety score (AS) (r = 0.723, p < 0.001), depression score (DS) (r = 0.850, p < 0.001) and visual analogue score (VAS) (r = 0.837, p < 0.001). The mean ReHo values of RSOG were also positively correlated with AS (r = 0.687, p = 0.001), DS (r = 0.661, p = 0.002) and VAS (r = 0.712, p < 0.001). The areas under the ROC curve of specific brain area ReHo values were as follows: RLG, 0.975; RSOG, 0.959; LMOG, 0.975; RPG, 1.000. Various degrees of brain activity changes reflected by ReHo values in different areas of the brain indicate the impact of TA on brain function. These findings may reveal related neural mechanisms underlying TA.

8.
Zootaxa ; 5082(1): 65-76, 2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-35390983

RESUMO

To date, only one species of whip spider has been recorded in China. Here, we describe a new species, Weygoldtia hainanensis sp. nov., from Hainan, China. The new species is morphologically similar to W. davidovi (Fage, 1946) and W. consonensis Miranda et al. 2021, but can be distinguished with a combination of the following characters: 26 segments in tibia I, 6-7 teeth on chelicerae, distitibia IV trichobothria sc and sf series each with 10-11 trichobothria. To validate our morphological inferences and support the erection of W. hainanensis sp. nov. as a new species, we sequenced the COI gene region for two individuals and performed molecular phylogenetic analyses. The inferred phylogenetic trees placed the new species within Weygoldtia and highlighted the evolutionary distinction between W. hainanensis sp. nov. and currently described whip spiders. The type specimens are deposited in the Museum of Biology, East China Normal University (ECNU).


Assuntos
Aracnídeos , Aranhas , Animais , China , Cabeça , Humanos , Filogenia , Aranhas/genética
9.
J Mech Behav Biomed Mater ; 103: 103529, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31783283

RESUMO

The cutting of tooth enamel using a high-speed air-turbine handpiece and carbide bur is a key procedure in oral surgeries, such as the minimally invasive extraction. However, presently little is known about the cutting mechanics and material removal mechanism related to tooth enamel machinability. In this study, the machinability of high-speed enamel cutting with carbide bur is studied by a computer-aided numerical control system. The dynamic cutting forces of enamel of the occlusal, buccal/lingual, and proximal surfaces were measured by the force measuring system. The force ratio, cutting torque, rotating speed, specific cutting energy, and bur wear were analyzed. The microstructure of enamel and carbide burs was observed by the scanning electron microscope, and the relationship between enamel microstructures and machinability was further analyzed. The results show that during the high-speed enamel cutting with carbide bur, the chip thickness is on the nano-scale, and the plastic deformation of the machined surface is obvious. With increased material removal rate, the cutting force, torque, specific cutting energy, and bur wear increases accordingly, whereas the rotating speed decelerates (p < 0.05). The different angles between the cutting direction and the axial direction of the enamel rods give rise to the large differences in the cutting mechanics and mechanism of the proximal, buccal/lingual, and occlusal surfaces of the teeth. When the cutting direction is parallel, vertical, and oblique 45° to the axial direction of the enamel rods, the force required for material fracture and crack propagation increases, and the cutting force increases as a consequence. Parallel and oblique 45° cutting are the main modes of tooth segmentation in the minimally invasive extraction. In comparison with the parallel cutting mode, the cutting force, torque, and cutting ratio of the oblique 45° cutting mode can be significantly increased, and the tool wear is obviously accelerated. This is the lowest priority in segmentation surgery, hence the problems of overload and temperature rise need to be considered. The cutting mechanics and cutting mechanism obtained in this study will provide scientific process guidance for dental cutting operations with the air-turbine handpiece driving bur.


Assuntos
Fenômenos Mecânicos , Dente , Esmalte Dentário , Propriedades de Superfície , Torque
10.
Shanghai Kou Qiang Yi Xue ; 29(6): 617-622, 2020 Dec.
Artigo em Zh | MEDLINE | ID: mdl-33778829

RESUMO

PURPOSE: To evaluate the clinical aesthetic effect of buccal alveolar ridge preservation (ARP) and connective tissue transplantation (CTG) in patients who received a single implant. METHODS: Forty-three patients with tooth loss admitted to the Department of Stomatology of Shunde Hospital of Southern Medical University from May 2014 to May 2016 were included in the study. Tooth extraction, ARP, implant implantation, CTG and permanent repair were performed respectively. The incidence of bleeding, depth of probing, marginal bone resorption, and red-white aesthetic effect of implants were evaluated 1 year and 3 years after surgery. The buccal mucosa thickness of implants before, immediately after CTG, 1 year and 3 years after surgery were measured. The patient satisfaction was evaluated by visual analogue scale (VAS) from masticatory function, overall aesthetics, attachment height, and color, respectively. The implant conditions at the third year after surgery were observed, and complications during follow-up were recorded. SPSS 20.0 software package was used for statistical analysis of the data. RESULTS: The follow-up rate in the first year after surgery was 100%, and that in the third year after surgery was 90.70%. One year and 3 years after operation, the aesthetic effect of the implant was satisfactory. At the 3rd year after operation, the scores of the near middle gingival papillary were significantly higher than that at the 1st year after operation (P<0.05). The buccal mucosal thickness of the implant immediately after CTG and 1 year and 3 years after surgery increased significantly compared with that before CTG (P<0.05). The buccal mucosal thickness of the implant increased 1.02 mm (relative stability: 90.12%) 1 year after operation and 1.01 mm (relative stability: 84.31%) 3 years after operation, respectively. The satisfaction scores of the patients on chewing function, overall aesthetics, attachment height and color of the implant immediately after CTG, one year after surgery and 3 years after surgery were all > 8. The 3-year survival rate of the implants was 100%, and the 3-year success rate of the implants was 97.44%. During the follow-up, two patients developed peri-implant mucositis, which was relieved after tooth cleaning, but no complications such as tissue flap necrosis, limited opening and tongue movement disorder occurred. CONCLUSIONS: ARP and CTG have good clinical and aesthetic effects on patients with tooth loss. In three years, the buccal mucosal thickness of the implant can be increased and relatively stable, which is worthy of clinical promotion and application.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Processo Alveolar , Tecido Conjuntivo/transplante , Implantação Dentária Endóssea , Estética Dentária , Humanos , Resultado do Tratamento
11.
Dis Markers ; 2020: 6683161, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33456630

RESUMO

OBJECTIVE: In order to further study the changes of cerebral functional connectivity in patients with toothache (TA), this study used the resting-state functional magnetic resonance imaging (rs-fMRI) technique and degree centrality (DC) analysis method. METHODS: Eighteen TA patients (8 males, 10 females) and 18 healthy individuals of similar age, sex, and educational levels were recruited as healthy controls (HCs) to take part in the study, and all underwent rs-fMRI examination. And DC technology was used to compare the state of their cerebral spontaneous functional activity. In order to compare the average DC values of the TA group and HC group, we used independent two-sample t-test and receiver operating characteristic (ROC) curve to compare the difference of DC values between the two groups, so as to distinguish the accuracy of TA diagnosis. Finally, we also carry out Pearson's linear regression analysis. RESULTS: The TA group showed higher DC values in the right lingual gyrus (RLG), right precentral gyrus, and left middle temporal gyrus (LMTG) than HCs. Moreover, ROC curve analysis indicated that the area under the curve (AUC) of each cerebral region studied had high accuracy. In addition, linear analysis indicated that the DC values of the RLG were positively correlated with the Hospital Anxiety and Depression Scale (HADS) (r = 0.844, p < 0.001), and the DC values of the LMTG were positively correlated with the visual analogue scale (VAS) (r = 0.723, p < 0.001). CONCLUSION: TA generates abnormal changes in the intrinsic activity patterns of pain-related and vision-related areas of the cerebral cortex, which will be beneficial to reveal the underlying neuropathic mechanisms.


Assuntos
Encéfalo/fisiologia , Conectoma , Odontalgia/fisiopatologia , Adulto , Encéfalo/diagnóstico por imagem , Encéfalo/fisiopatologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Odontalgia/diagnóstico por imagem , Percepção Visual
12.
Biomacromolecules ; 10(10): 2809-16, 2009 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-19743844

RESUMO

A p-vinylbenzyl sulfobetaine was grafted from cellulose membrane (CM) using surface-initiated atom transfer radical polymerization for blood compatibility improvement. Surface structure, wettability, morphology, and thermal stability of the CM substrates before and after modification were characterized by attenuated total reflectance Fourier transform infrared spectra, X-ray photoelectron spectroscopy measurement, water contact angle measurement, atomic force microscopy, and thermogravimetric analysis, respectively. The results showed that zwitterionic brushes were successfully fabricated on the CM surfaces, and the content of the grafted layer increased gradually with the polymerization time. The blood compatibility of the CM substrates was evaluated by protein adsorption tests and platelet adhesion tests in vitro. It was found that all the CMs functionalized with zwitterionic brush showed improved resistance to nonspecific protein adsorption and platelet adhesion, even though the grafting polymerization was conducted for several minutes.


Assuntos
Sangue , Celulose/química , Membranas Artificiais , Plaquetas/citologia , Adesão Celular , Humanos , Espectroscopia de Ressonância Magnética , Microscopia de Força Atômica , Espectroscopia de Infravermelho com Transformada de Fourier
13.
Zhongguo Shi Yan Xue Ye Xue Za Zhi ; 26(4): 1072-1078, 2018 Aug.
Artigo em Zh | MEDLINE | ID: mdl-30111410

RESUMO

OBJECTIVE: To investigate the clinical characteristics and outcome of parhents with EBV infection conbined with hemophagocytic syndrome and Hodgkin's lymphoma. METHODS: The morphotogy of bone marrow cells was observed by bone marrow smear and light microscopy, the pathologic changes of bone marrow ware analyzed by bone marrow biopsy and immunohistochemistry methord, the pathologic changes of lymphonudes ware detected by immunohistochemical methord, the paticnts were treated with ABVD (epirubicin, bleomycin, vincristine and dacarbazine) chemotherapeutic regimen. RESULTS: Fever complicatid with pancytopenia, obvious increase of ferritin and sCD25, hypofibrinogenemia, hemophogocytic phenomen of bone marrow, increase of EBV-DNA copy number ware observed, which all accorded with the criteria EBV righted hemophagocytic syndrome. The curative efficacy of amtiinfective treatmatnt was poor, After treatment with HLH-2004 regimen, the fever symptome and the laboratory indicaters such as whole blood cells, ferritin and fibrinogen all were recovered to normal levels. Left mandibular lymphadenctasis was confirmed as Hodgkin's lymphoma (mixed cell type) by pathological examination. The patient achieved complete molecular remission after 1 course chemotherapy with ABVD regimen. The level of EBV-DNA copy number were also decreased. As the reshlt, the patient's hemophagocytic syndrome had bean effectively controlled, and the Hodgkin's lymphoma is still in complete remission. CONCLUSION: Epstein-Barr virus-ratated hemophagocytic syndrome and Hodgkin's lymphoma are rare, and their long-term prognosis needs to be further explored.


Assuntos
Infecções por Vírus Epstein-Barr , Herpesvirus Humano 4 , Doença de Hodgkin , Humanos , Linfo-Histiocitose Hemofagocítica , Vincristina
14.
J Biomater Sci Polym Ed ; 29(6): 663-682, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29375018

RESUMO

Abdominal wall defects are a common medical problem, and inadequate repair methods can lead to serious complications. Abdominal wall reconstruction using autologous tissue, or non-biological, biological, or composite patches is often performed to repair defective areas. In particular, composite patches containing both polymeric and biological materials have gained increasing attention due to their good mechanical properties and biocompatibility. However, it is still unclear whether the quality of repairs using composite patches is superior to that of a biological patch. Based on the limitations of previous studies, we compared small intestinal submucosa (SIS) patches with SIS + polypropylene mesh (PPM) patches for repairing abdominal wall defects in adult beagle dogs. Forty-five female dogs were subjected to surgical resection to produce abdominal wall defects. SIS or SIS + PPM was used as patch for the defects. Morphology, biomechanics, and histological evaluations were performed to evaluate the efficacy and safety of such therapies. Our findings demonstrated that SIS had advantages over SIS + PPM considering biological activity and histocompatibility without increasing the risk of repair failure.


Assuntos
Parede Abdominal/cirurgia , Intestino Delgado/citologia , Polipropilenos/farmacologia , Telas Cirúrgicas , Adesividade , Animais , Materiais Biocompatíveis/farmacologia , Cães , Feminino , Regulação da Expressão Gênica/efeitos dos fármacos , Mediadores da Inflamação/metabolismo , Resistência à Tração
15.
Onco Targets Ther ; 11: 8555-8564, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30584316

RESUMO

OBJECTIVE: CAM2028 (Episil®; Camurus AB, Lund, Sweden) is a liquid for use in the oral cavity to treat various pains associated with mouth injuries. Upon contact with the swollen oral mucosa, the oral liquid forms a thin protective film that acts as a mechanical barrier to relieve pain. This study was the first in China to evaluate the local analgesic effect of oral liquid in cancer patients who developed oral mucositis following chemotherapy and/or radiotherapy. METHODS: A total of 60 patients were randomized in a 1:1 ratio to the CAM2028 group (the pump device was firmly pressed three times and the fluid was distributed to the painful area of the oral cavity) or KS (a mucoadhesive oral wound rinse, Kangsu™; Luye Pharmaceutical Co. Ltd, Nanjing, China) group (5 mL of the oral rinse was poured into and kept in the oral cavity for at least 1 minute). The primary endpoint was the area under the oral mucosal pain score-time curve (AUC) within 6 hours of treatment in the trial and control groups. Medical device adverse events were assessed according to the National Cancer Institute's Common Terminology Criteria for Adverse Events, version 4.0. Statistical analyses were performed using the chi-squared test (Fisher's exact test), independent-samples t-test, and analysis of covariance. RESULTS: Sixty patients were included in the per-protocol set population analysis. The average (mean ± SD) 6-hour AUC of the CAM2028 group and the KS group was 14.20±10.29 and 24.46±14.15, respectively. The difference between the groups was statistically significant (P=0.0022). The incidence of adverse events in the trial group and the control group was 16.67% and 30.0%, respectively, and there was no statistical difference. CONCLUSIONS: CAM2028 displayed an efficacious local analgesic effect in cancer patients who developed oral mucositis following chemotherapy and/or radiotherapy. The results demonstrated its potential value in clinical applications.

16.
Hepatobiliary Pancreat Dis Int ; 4(4): 582-4, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16286267

RESUMO

BACKGROUND: The configuration and course of liver blood vessels (LBVs) are involved in the study of pathogenesis of hepatic diseases including liver cirrhosis, tissue engineering of the liver and surgical treatment of diseases of the liver and gallbladder. In the study of vascularization in tissue engineering of the liver in particular, the work we should do is to get the anatomy data of LBVs for computer-aided reconstruction of digital model of LBVs. In doing so, the casting sample of rat liver blood vessels (RLBVs) is fabricated and the data of each section of the sample is harvested. METHODS: Liquid polymer preparation (8%-10%), which was made of chlorinated poly vinyl chloride (CPVC) as a solute, acetone as solvent and pigment, was injected into the RLBVs of 40 rats. Once acetone evaporated, the preparation solidified. When the cells and connective tissue were dissolved by hydrochloric acid, a casting sample of RLBV was left. The sample was embedded in paraffin and cut into sections. The data of each section of RLBVs was collected by digital camera. RESULTS: In 36 rats, the casting sample of RLBVs was made successfully by this method. The diameter of the hepatic arteries varied from 0.8 to 0.2 mm, the portal veins from 2.0 to 0.1 mm, and the hepatic veins from 2.2 to 0.2 mm. In each rat, about 150 photographs of the sections of RLBVs were taken. CONCLUSION: The method described above is feasible for getting experimental data for computer-aided reconstruction of the digital model of RLBVs.


Assuntos
Circulação Hepática , Acetona , Animais , Desenho Assistido por Computador , Processamento de Imagem Assistida por Computador/métodos , Cloreto de Polivinila , Ratos , Ratos Sprague-Dawley
17.
BMJ Case Rep ; 20152015 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-26516249

RESUMO

Posterior atlantoaxial dislocation (PAAD) without fracture of the odontoid process is a rare injury. Authors have variously reported closed or open reduction, followed by either anterior or posterior fixation, but there is no consensus on best treatment. We present a particularly unstable case of PAAD. Open reduction through a retropharyngeal approach with odontoidectomy was required for reduction. Anterior fixation with transarticular lag screws was required prior to posterior fixation with pedicle screws. Despite non-compliance with postoperative immobilisation, imaging at 20-month follow-up confirmed solid fusion. The patient is pain-free with a good range of movement of the neck and has returned to a manual job. Our case had a greater degree of instability than was previously reported, which necessitated 360° fixation. This is the first reported case of this treatment strategy, which provided a very stable fixation allowing fusion despite early movement and without causing undue stiffness.


Assuntos
Articulação Atlantoaxial/cirurgia , Luxações Articulares/cirurgia , Fusão Vertebral/métodos , Traumatismos da Coluna Vertebral/cirurgia , Adulto , Articulação Atlantoaxial/lesões , Parafusos Ósseos , Humanos , Masculino , Fusão Vertebral/instrumentação , Tempo para o Tratamento
18.
Huan Jing Ke Xue ; 35(5): 1838-42, 2014 May.
Artigo em Zh | MEDLINE | ID: mdl-25055675

RESUMO

The technology of non-water-soluble mediator anaerobic biological catalysis has attracted more and more attention in the field of environment technology. In this study, five kinds of quinonly compounds were grafted on the chloromethylation polystyrene macromolecular carrier by Friedel-Crafts reaction. Reaction factors of temperature and molar ratio for the 1,4-naphthoquinone grafting carrier were optimized, and the optimal temperature was 78 degreesC while the optimal molar ratio of 1, 4-naphthoquinone and chloromethylation polystyrene was 2: 1. Fourier infrared spectrum analysis confirmed that the quinone groups were successfully grafted on the macromolecular backbone chloromethylation polystyrene. Catalysis using the five kinds of quinonly materials as non-water-soluble redox mediators enhanced the biological denitrification rate and the decoloration of azo dyes, meanwhile these materials showed good reusability in the biodegradation of azo dye. This study developed a new method for the preparation of quinonly materials and revealed a new field in the technology of mediator catalysis.


Assuntos
Compostos Azo/química , Corantes/química , Poliestirenos/química , Eliminação de Resíduos Líquidos/métodos , Águas Residuárias/química , Biodegradação Ambiental , Catálise , Naftoquinonas/química , Oxirredução
19.
ACS Appl Mater Interfaces ; 4(8): 4031-9, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22856677

RESUMO

AB diblock copolymers comprised of poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC) and poly(3-methacryloxypropyl trimethoxysilane) (PMTSi) segments, which are used for biocompatible coatings, were investigated. Block copolymers with various compositions were synthesized by atomic transfer radical polymerization (ATRP). The obtained copolymers were dissolved in an ethanol solution, and dynamic light scattering showed that all block copolymers were capable of existing as micelles. After a convenient "one-step" reaction, the cellulose membranes could be covalently modified by these copolymers with stable chemical bonds (C-O-Si and Si-O-Si). Block copolymers with different PMPC chain length were applied to surface modification to find the most suitable copolymer. The functional MPC density can be controlled by adjusting the ratio of the two monomers (MPC and MTSi), which also affect surface properties, including the surface contact angle, surface morphology, and number of functional PC groups. The low-fouling properties were measured by protein adsorption, platelet adhesion and activation, and cell adhesion. Protein adsorption of bovine serum albumin (BSA), fibrinogen, and human plasma were also tested and a moderate monomer composite was attained. The protein adsorption behavior on the novel interfaces depends both on MPC density and PMPC chain length. Platelet adhesion and activation were reduced on all the modified surfaces. The adhesion of Human Embryonic Kidney 293 (293T) cells on the coated surfaces also decreased.


Assuntos
Materiais Biocompatíveis/química , Celulose/química , Química Farmacêutica/métodos , Metacrilatos/química , Fosforilcolina/análogos & derivados , Polímeros/química , Silanos/química , Adsorção , Animais , Plaquetas/efeitos dos fármacos , Bovinos , Adesão Celular , Fibrinogênio/química , Células HEK293 , Humanos , Micelas , Fosforilcolina/química , Adesividade Plaquetária , Proteínas/química , Albumina Sérica/química , Propriedades de Superfície
20.
Huan Jing Ke Xue ; 28(4): 886-90, 2007 Apr.
Artigo em Zh | MEDLINE | ID: mdl-17639955

RESUMO

The straw contains a high content of lignin, which cannot be well utilized by anaerobic bacteria in high solid anaerobic digestion process. This paper presents the experimental investigation of the straw pre-treatment, which aims to destroy the complex structure of the lignin to enhance its high solid anaerobic digestion. The straw is pre-treated in different solutions including NaOH, ammonia, H2SO4, and carbamide. The pre-treating effects are expressed by COD concentration dissolved in the solutions and the 14-day biogas generation in the enhanced aerogenic experiment. Different affecting factors, such as the concentration of the chemical solution, the species of the straw, the pre-treatment reaction time, the reaction temperature and the size of the straw, are investigated. The results show that NaOH solution is the most effective pre-treatment chemical among the four different solutions. The experimental results still indicate that the accumulative biogas production can be 1 500 mL (10 g straw) in 14 days after pre-treatment in 4 mg/L NaOH solution and the dissolved COD in the solution reaches 39 000 mg/L after 24 hours. In addition, the experiment shows that the lignin content in the straw is reduced from 28% to 19% after pre-treatment in 1.5% (in weight) NaOH solution, and it can improve the straw treatment efficiency using high solid anaerobic digestion process.


Assuntos
Bactérias Anaeróbias/metabolismo , Caules de Planta/química , Hidróxido de Sódio/química , Biodegradação Ambiental , Lignina/química , Lignina/metabolismo , Triticum
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA