Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Oral Health ; 20(1): 127, 2020 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-32345292

RESUMO

BACKGROUND: In the current study, we aimed to evaluate the accuracy of indirect bonding by either three-dimensional (3D) printing guides or double-layer guide plates. The results may serve as a clinical reference for bracket placements. METHODS: In total, 140 teeth were collected and arranged into five pairs of full dentition. The marking points were labeled on the buccal/labial surface of the crown in these orthodontic study models. (1) 3D printing guide: A digital profile was generated using an intraoral scanner. Two types of indirect bonding guide, namely the whole denture type and the single tooth type, were designed with the 3Shape TRIOS® Standard intraoral scanner and fabricated using 3D printing technology. (2) Double-layer guide plate: A working model was obtained by replicating the experimental models, and the double-layer guide plate was then made of the inner layer soft film (1.0 mm thickness) and the outer layer hard film (0.6 mm or 0.8 mm thickness). Brackets were transferred from working models to study models by the indirect bonding trays. We measured and analyzed the distance between marking points and bracket placement. Statistical analysis was done using SPSS 20.0 software. The accuracy of indirect bonding between 3D printing guide and double-layer guide plate was compared using paired t-test. RESULTS: According to our data, there was a significant difference between the 0.6 mm group and 0.8 mm group when the brackets were indirectly adhered using double-layer guide plates (p = 0.036). However, no statistical significance in bracket positioning accuracy was revealed between two types of 3D printing guide (p = 0.078), as well as between the 3D printing guide group and the 0.6 mm double-layer guide plate group (p = 0.069). CONCLUSIONS: When applying double-layer guide plates for indirect bonding, the 0.6 mm group is more accurate than the 0.8 mm group. When utilizing 3D printing guides for indirect bonding, whole denture type is more accessible than single tooth type but with no significant difference in accuracy. The accuracy of indirect bonding is comparable when using 3D printing guides (whole denture type) and double-layer guide plates (0.6 mm).


Assuntos
Colagem Dentária , Braquetes Ortodônticos , Impressão Tridimensional , Modelos Dentários , Coroa do Dente
2.
Cell Physiol Biochem ; 40(5): 944-952, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27941347

RESUMO

BACKGROUND: Osteotome sinus floor elevation is a less invasive approach to augment an insufficient alveolar bone at the posterior maxilla for dental implantation. However, this approach has some limitations due to the lack of sinus lift tools available for clinical use and the small transcrestal access to the maxillary sinus floor. We recently invented shape-memory Ni/Ti alloy wire containing tube elevators for transcrestal detaching maxillary sinus mucosa, and developed goat ex vivo models for direct visualizing the effectiveness of detaching sinus mucosa in real time during transcrestal maxillary sinus floor elevation. METHODS: We evaluated our invented elevators, namely elevator 012 and elevator 014, for their effectiveness for transcrestal detaching maxillary sinus mucosa using the goat ex vivo models. We measured the length of sinus mucosa detached in mesial and distal directions or buccal and palatal directions, and the space volume created by detaching maxillary sinus mucosa in mesial, distal, buccal and palatal directions using the invented elevators. RESULTS: Elevator 012 had a shape-memory Ni/Ti alloy wire with a diameter of 0.012 inch, while elevator 014 had its shape-memory Ni/Ti alloy wire with a diameter of 0.014 inch. Elevator 012 could detach the goat maxillary sinus mucosa in the mesial or distal direction for 12.1±4.3 mm, while in the buccal or palatal direction for 12.5±6.7 mm. The elevator 014 could detach the goat maxillary sinus mucosa for 23.0±4.9 mm in the mesial or distal direction, and for 19.0±8.1 mm in the buccal or palatal direction. An average space volume of 1.7936±0.2079 ml was created after detaching the goat maxillay sinus mucosa in both mesial/distal direction and buccal/palatal direction using elevator 012; while the average space volume created using elevator 014 was 1.8764±0.2366 ml. CONCLUSION: Both two newly invented tube elevators could effectively detach the maxillary sinus mucosa on the goat ex vivo sinus models. Moreover, elevator 014 has advantages over the elevator 012 for the capability to detach sinus mucosa.


Assuntos
Seio Maxilar/efeitos dos fármacos , Mucosa/efeitos dos fármacos , Níquel/farmacologia , Levantamento do Assoalho do Seio Maxilar/métodos , Titânio/farmacologia , Animais , Estudos de Viabilidade , Feminino , Cabras , Masculino
3.
J Appl Biomater Funct Mater ; 19: 22808000211014724, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34210203

RESUMO

PURPOSE: The effect of flushing at different temperatures on the preparation ability of rotary nickel-titanium files was investigated to provide guideline for clinical application. METHODS: Sixty ProTaper Universal F1 rotary nickel-titanium files were randomly divided into three groups treated by flushing at 6°C, 23°C, and 40°C. Root canal preparation was conducted by step-by-step method on standardized nickel-titanium instrument fracture models. During preparation, the thrust force was set as 10 N, and water was continuously flushed. The motor speed was 350 rpm (rounds per minute), and the torque was 3.0 N cm. When the set torque was reached, the motor automatically rotated in the reverse direction and was pulled out. RESULTS: Root canal preparation was performed using ProTaper Universal F1 rotary nickel-titanium files treated by flushing. The numbers of rotations before the device was fracture were 429.33 ± 214.68, 821.92 ± 410.43, and 1304.92 ± 297.81, respectively. When each root canal was completed, the numbers of instrument rotations were 272.15 ± 88.30, 188.85 ± 34.36, and 163.41 ± 16.18, respectively. Rank sum test and analysis of variance were performed by IBM SPSS Statistics v21.0 software, and both of them were p < 0.01, indicating that the number of cycles to failure (NCF) and the number of instrument rotations for each root tube were statistically different at the three temperatures. CONCLUSIONS: The self-made resin-simulated curved root canal can replace the real root canal to complete the root canal preparation experiment. The group of nickel-titanium files treated by flushing at 23°C can prepare more root canals and prolong the life of nickel-titanium files than at 6°C. When flushing was done at 40°C, the number of root canals prepared by nickel-titanium files was the highest, and it was not easy to damage the instrument, but lateral perforation occurred easily during root canal preparation.


Assuntos
Níquel , Titânio , Cavidade Pulpar , Desenho de Equipamento , Preparo de Canal Radicular , Temperatura
4.
J Appl Biomater Funct Mater ; 19: 2280800020987403, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33509031

RESUMO

OBJECTIVE: To evaluate the effect of synchronous water irrigation on the fatigue resistance of nickel-titanium instrument. METHODS: A standardized cyclic fatigue test models were established, and five types of nickel-titanium instruments (PTU F1, WO, WOG, RE, and M3) were applied. Each instrument was randomly divided into two groups (N = 12). There was synchronous water irrigation in the experimental group, and no water irrigation in the control group. Besides, ProTaper Universal F1 was randomly divided into 10 groups (N = 20). In the static group, nickel-titanium instruments were divided into one control group (no irrigation, N = 20) and six experimental group (irrigation, N = 20) based on different flow rate, angle and position; while in the dynamic group, instruments were divided into one control group (no irrigation, N = 20) and two experimental group (irrigation, N = 20) based on different flow rate. The rotation time (Time to Failure, TtF) of instruments was recorded and analyzed. RESULTS: According to the static experiments, the TtF of instruments in all experimental groups was significantly higher than that in the static control group. Besides, the dynamic tests of PTU F1 showed that the TtF in the experimental group was significantly higher than that in the dynamic control group. Compared with control group, the TtF in the experimental groups increased by at least about 30% and up to 160%. The static and dynamic tests of PTU F1 showed that the TtF of nickel-titanium instrument in all experimental groups was significantly higher than that in the control group. However, there was no significant difference between any two experimental groups. CONCLUSION: Regardless of dynamic or static model, TtF with irrigation was longer than that with non-irrigation, indicating that synchronous irrigation can increase the fatigue resistance of nickel-titanium instrument. However, different irrigation conditions may have the same effect on the fatigue resistance.


Assuntos
Níquel , Titânio , Desenho de Equipamento , Falha de Equipamento , Teste de Materiais , Preparo de Canal Radicular , Rotação , Estresse Mecânico
5.
Bioengineered ; 8(4): 359-366, 2017 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-27791456

RESUMO

The objective of this study was to comparatively evaluate 3 different sinus lift tools, namely umbrella-shaped sinus lift curette YSL-04, our recently designed probe-improved sinus lift curettes, and our newly invented elevator 014, using our previous developed goat ex vivo models for direct visualizing the effectiveness of detaching sinus mucosa in real time. Goat ex vivo models for direct visualizing the effectiveness of detaching sinus mucosa in real time were generated according to our previously developed protocol. The effectiveness for each tool was evaluated through the length of sinus mucosa detached in mesial and distal directions or buccal and palatal directions, and the space volume created by detaching maxillary sinus mucosa in mesial, distal, buccal and palatal directions. The results showed that all 3 sinus lift tools could transcrestally detach the maxillary sinus mucosa and create extra space under the elevated sinus floor on the goat ex vivo sinus models. Moreover, our newly invented elevator 014 had advantages over the other 2 in term of the capability to detach the sinus mucosa. Our newly invented elevator 014 might be a promising tool for detaching maxillary sinus mucosa in transcrestal maxillary sinus floor elevation.


Assuntos
Seio Maxilar/cirurgia , Mucosa/cirurgia , Mucosa Nasal/cirurgia , Levantamento do Assoalho do Seio Maxilar/instrumentação , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Cabras , Masculino , Seio Maxilar/anatomia & histologia , Mucosa/anatomia & histologia , Mucosa Nasal/anatomia & histologia , Levantamento do Assoalho do Seio Maxilar/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA