Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Ann Plast Surg ; 90(1 Suppl 1): S2-S9, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36752416

RESUMO

BACKGROUND: LeFort I osteotomy changes the morphology of the nose. The cinch suture has been proven to prevent the increase in nasal base and alar width. Different types of cinch sutures have been proposed. However, their effectiveness is unclear. AIM AND OBJECTIVES: The aim of this study was to compare the surgical outcomes between conventional and modified cinch techniques through a systematic review and meta-analysis of randomized control trials (RCTs). MATERIAL AND METHODS: We performed systematic search from Embase, PubMed, and the Cochrane Library according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement up to March 2021. The surgical techniques of different cinch sutures were reviewed, and the outcomes of nasal alar width and alar base width were compared between modified and conventional methods. RESULTS: A total of 4 eligible RCTs were included in this meta-analysis. Pooled data showed no significant difference in alar base width change between modified and conventional methods (mean difference, -0.37; 95% confidence interval, -1.32 to 0.57; P = 0.44). Pooled data of 3 studies also showed no significant difference in nasal alar width change (mean difference, -0.11; 95% confidence interval, -1.18 to 0.95; P = 0.83). CONCLUSION: Based on the current data pooled from the available RCTs, no significant difference was found between the conventional cinch technique and the modified technique.


Assuntos
Maxila , Cartilagens Nasais , Humanos , Cartilagens Nasais/cirurgia , Maxila/cirurgia , Osteotomia de Le Fort/métodos , Nariz/cirurgia , Técnicas de Sutura
2.
Ann Plast Surg ; 82(1S Suppl 1): S77-S85, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30516560

RESUMO

BACKGROUND AND PURPOSE: Extensive orbital floor and medial wall fractures compared with isolated orbital wall fractures are more likely to require surgical correction because of a higher possibility of complications like diplopia, enophthalmos, or numbness. The unique and complex contours of the orbital anatomy limit the intraoperative view of the intraorbital anatomy, and complex orbital fractures involving the buttress of the transition zone area all make orbital reconstruction surgery more challenging. The aim of this study was to describe our experience with surgical approaches using navigation- and endoscope-assisted guidance for extensive orbital floor and medial wall fracture reconstruction. PATIENTS AND METHODS: A retrospective study was conducted on consecutive 17 patients from 2015 to 2017 presenting with unilateral extensive orbital floor and medial wall fractures at the Chang Gung Memorial Hospital, Linkou Branch. The fractures were treated surgically with a preformed mesh plate and layered Medpor (Porex Surgical Inc, Atlanta, Ga) through navigation and endoscopy. The preoperative and postoperative functional and aesthetic outcomes were described. RESULTS: All extensive orbital floor and medial wall fractures were successfully reconstructed. Of the 17 patients, 11 experienced diplopia preoperatively, and for 2 of the 11 patients, diplopia improved immediately after surgery. In the remaining 9 patients, diplopia still persisted after surgery; however, diplopia recovered after an average of 3.44 months (range, 1-9 months). Average enophthalmos among the 10 patients, evaluated by postoperative follow-up computed tomography scan, improved from 2.99 to 0.68 mm. There were no major complications during follow-up, and all patients were satisfied with their final appearance and function. CONCLUSIONS: On the basis of the results, our surgical approach using preformed titanium mesh plates and Medpor under the assistance of navigation and endoscopy can be a safe, accurate, and effective method for the management of extensive orbital floor and medial wall fractures and clearly optimizes functional and aesthetic outcomes.


Assuntos
Endoscopia/métodos , Fraturas Orbitárias/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Implantação de Prótese/métodos , Cirurgia Assistida por Computador/métodos , Telas Cirúrgicas , Adulto , Estudos de Coortes , Feminino , Seguimentos , Fixação de Fratura/métodos , Consolidação da Fratura/fisiologia , Humanos , Escala de Gravidade do Ferimento , Masculino , Fraturas Orbitárias/diagnóstico por imagem , Segurança do Paciente , Polietilenos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/fisiopatologia , Prognóstico , Estudos Retrospectivos , Medição de Risco , Cirurgia Assistida por Computador/efeitos adversos , Titânio , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA