Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Foot Ankle Surg ; 49(2): 128-34, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20137980

RESUMO

The primary goal of this study was to evaluate a cross-linked acellular porcine dermal patch (APD), as well as platelet-rich plasma fibrin matrix (PRPFM), for repair of acute Achilles tendon rupture in a sheep model. The 2 surgically transected tendon ends were reapproximated in groups 1 and 2, whereas a gap was left between the tendon ends in group 3. APD was used to reinforce the repair in group 2, and autologous PRPFM was used to fill the gap, which was also reinforced with APD, in group 3. All sheep were humanely euthanized at 24 weeks after the repair, and biomechanical and histological testing were performed. Tensile strength testing showed a statistically significant difference in elongation between the operated limb and the unoperated contralateral limb in groups 1 and 3, but not in group 2. All operated tendons appeared healed with no apparent fibrosis under light and polarized microscopy. In group 1, all surgical separation sites were identifiable, and healing occurred via increasing tendon thickness. In group 2, healing occurred with new tendon fibers across the separation, without increasing tendon thickness in 2 out of 6 animals. Group 3 showed complete bridging of the gap, with no change in tendon thickness in 2 out of 6 animals. In groups 2 and 3, peripheral integration of the APD to tendon fibers was observed. These findings support the use of APD, alone or with PRPFM, to augment Achilles tendon repair in a sheep model.


Assuntos
Tendão do Calcâneo/cirurgia , Materiais Biocompatíveis , Tendão do Calcâneo/lesões , Tendão do Calcâneo/patologia , Animais , Fenômenos Biomecânicos , Colágeno , Reagentes de Ligações Cruzadas , Feminino , Fibrina , Plasma Rico em Plaquetas , Ruptura , Ovinos , Resistência à Tração , Alicerces Teciduais , Cicatrização
2.
J Arthroplasty ; 24(2): 303-9, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18524532

RESUMO

Clinically retrieved highly cross-linked ultrahigh molecular weight polyethylene (HXPE) acetabular liners have demonstrated scratching, whereas conventional ultrahigh-molecular-weight polyethylene (UHMWPE) implants show a smoother surface early after implantation. In the present study, the potential of bone particles and soft tissues, rather than cement, to scratch the articular surface of HXPE and UHMWPE (gamma radiated) acetabular components was evaluated; multiple bone particles located at the articular surface for 3600 simulated walking cycles replicated the scratches observed on retrieved implants. By remelting, these scratches were confirmed to be due to plastic deformation of the polyethylene, not wear. Furthermore, it was shown using wear testing that these scratches did not affect the subsequent wear rate of HXPE or conventional UHMWPE. Wear rates of scratched conventional and cross-linked polyethylene were not significantly different from unscratched conventional and cross-linked polyethylene, respectively.


Assuntos
Acetábulo , Artroplastia de Quadril/instrumentação , Teste de Materiais/métodos , Polietileno , Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Fenômenos Biomecânicos , Feminino , Prótese de Quadril , Humanos , Pessoa de Meia-Idade , Peso Molecular , Polietileno/química , Caminhada
3.
J Knee Surg ; 22(3): 196-204, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19634722

RESUMO

The primary objective of this study was to determine the retention rate of neocartilage constructs in caprine full-thickness cartilage defects by fibrin sealant alone. Two defects, one each on the trochlea and the medial femoral condyle, were created in the stifle joint in 12 goats. Eight goats (16 defects) were treated with neocartilage constructs and 4 goats (8 defects) with fibrin glue alone. Postoperative activity was protected weight bearing for 6 weeks and then unrestricted for 18 weeks. At 24-week procurement, 4 neocartilage constructs were retained in 8 medial femoral defects and 4 in 8 trochlear defects. In gross comparison, the defects that retained the construct had a mean grade significantly higher than defects treated with fibrin glue alone. The mean histological score of defects with retained constructs was also higher than those treated with fibrin sealant alone. There was no appreciable immunologic reaction to the human neocartilage xenograft or human fibrin sealant.


Assuntos
Cartilagem Articular/fisiologia , Cartilagem Articular/cirurgia , Condrócitos/citologia , Adesivo Tecidual de Fibrina/administração & dosagem , Adesivos Teciduais/administração & dosagem , Engenharia Tecidual , Animais , Cartilagem Articular/citologia , Cartilagem Articular/lesões , Células Cultivadas , Feminino , Cabras , Humanos , Articulação do Joelho/patologia , Articulação do Joelho/cirurgia , Modelos Animais , Distribuição Aleatória , Regeneração
4.
J Arthroplasty ; 23(5): 751-61, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18534394

RESUMO

This article reports on a commercially available extensively cross-linked ultrahigh molecular-weight polyethylene (HXPE) produced by subjecting molded GUR 1050 ultrahigh molecular-weight polyethylene (UHMWPE) to 100 +/- 10 kGy of electron beam radiation followed by melt annealing and sterilization by gas plasma. When compared to contemporary conventional molded GUR 1050 UHMWPE sterilized by 37 kGy of gamma radiation, the HXPE material has enhanced wear properties, has no detectable free radicals, and is resistant to oxidation and oxidative-related material property changes. The relative wear improvement of the HXPE is maintained in the presence of bone cement or alumina particles. The HXPE produced greater than 90% fewer wear particles in all size ranges and statistically significantly (P < .0001) smaller average-size particles than did the conventional UHMWPE.


Assuntos
Resinas Acrílicas , Artroplastia de Quadril/instrumentação , Polietileno , Resinas Acrílicas/química , Resinas Acrílicas/efeitos da radiação , Fenômenos Biomecânicos , Cabeça do Fêmur/anatomia & histologia , Raios gama , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Peso Molecular , Oxirredução , Material Particulado , Polietileno/química , Polietileno/efeitos da radiação
5.
J Shoulder Elbow Surg ; 16(5 Suppl): S184-90, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17574876

RESUMO

In this study we evaluated 2 commercially available rotator cuff repair augmentation patches in an in vivo sheep model using mechanical testing and histologic techniques. Bilateral infraspinatus tears were created and repaired in 2 groups of 8 adult ewes. Each group (killed at 9 or 24 weeks) included 5 repaired with suture alone, 6 repaired and augmented with a cross-linked acellular porcine dermal (PD) patch (Zimmer Collagen Repair Patch), and 5 repaired and augmented with a porcine small intestine submucosa (SIS) patch (Restore Orthobiologic Soft Tissue Implant; DePuy Orthopaedics). At 3 weeks, sheep with suture repair and an SIS patch had significant elevation of plasma fibrinogen levels (P < .05) whereas sheep with suture repair and a PD patch elicited no elevation in plasma fibrinogen levels. At 9 weeks, the mean failure load was 201 +/- 60 lb for suture repairs, 182 +/- 63 lb for PD repairs, and 137 +/- 16 lb for SIS repairs. Within any individual sheep, the shoulder undergoing PD repair always had a higher failure load than the contralateral suture or shoulder undergoing SIS repair. At 9 weeks, macrophages were seen on all PD surfaces whereas most of the SIS materials were resorbed. At 24 weeks, failure loads were identical between groups. Macrophages had disappeared from the PD groups, and integration of the PD patch into the surrounding tissue with vascular and fibroblastic invasion was seen. For the SIS group, diverse tissue types (including ectopic bone) were seen.


Assuntos
Materiais Biocompatíveis , Manguito Rotador/cirurgia , Traumatismos dos Tendões/cirurgia , Animais , Fenômenos Biomecânicos , Modelos Animais de Doenças , Feminino , Fibrinogênio/análise , Mucosa Intestinal/transplante , Intestino Delgado/transplante , Manguito Rotador/patologia , Manguito Rotador/fisiopatologia , Lesões do Manguito Rotador , Ovinos , Traumatismos dos Tendões/patologia , Cicatrização/fisiologia
6.
J Biomed Mater Res B Appl Biomater ; 97(2): 355-63, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21442745

RESUMO

The purpose of the study was to design and develop unique drug delivery systems with controllable multiple burst releases of drugs for treating osteoarthritis. Chondroitin sulfate (CS) was encapsulated into four types of PLGA materials, that is, PLGA 50:50, PLGA 65:35, PLGA 75:25, and PLGA 85:15. The effects of microsphere size and various combinations of blend PLGA microspheres on CS release were investigated. The cytotoxicity of the CS-encapsulated microspheres was investigated according to the ISO 10993 guideline. Our study showed that the encapsulation efficiency of CS into PLGA 50:50 microspheres varied with the size of microspheres; however, the encapsulation efficiencies of CS into PLGA microspheres were independent of the types of PLGA materials. The size of PLGA microspheres was shown to affect the rate of CS release. With the increase of microsphere size from 75-150 µm to 300-355 µm, the initial CS release decreased. Further increase in microsphere size led to an increase in the initial CS release. In addition, combination of different types of PLGA microspheres was shown to be capable of achieving multiple burst CS releases. Moreover, the CS encapsulated PLGA microspheres were shown to be non-cytotoxic. This study proved the concept of multiple burst drug releases that were achieved by encapsulating CS into different types of PLGA microspheres and delivering CS from systems consisting of mixed types of PLGA microspheres, which may be applied to treat osteoarthritis by mimicking multiple intra-joint injection of therapeutic agents.


Assuntos
Sulfatos de Condroitina/química , Sulfatos de Condroitina/uso terapêutico , Sistemas de Liberação de Medicamentos , Ácido Láctico/química , Microesferas , Osteoartrite/tratamento farmacológico , Ácido Poliglicólico/química , Materiais Biocompatíveis/química , Materiais Biocompatíveis/metabolismo , Sulfatos de Condroitina/metabolismo , Composição de Medicamentos , Humanos , Ácido Láctico/metabolismo , Teste de Materiais , Microscopia Eletrônica de Varredura , Tamanho da Partícula , Ácido Poliglicólico/metabolismo , Copolímero de Ácido Poliláctico e Ácido Poliglicólico
7.
J Orthop Res ; 28(9): 1120-6, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20162713

RESUMO

The wear, delamination, and fatigue resistance of artificially aged gamma irradiation-sterilized conventional polyethylene (CPE) and gas-plasma-sterilized melt-annealed highly crosslinked polyethylene tibial inserts (HXPE) were compared. Six CPE and 12 HXPE (six irradiated at 58 kGy and six at 72 kGy) left knee inserts were wear tested for 5.5 million cycles (Mc) under loads and motions that mimic activities of daily living, such as walking, chair rise, stair ascent, and deep squatting. Another six HXPE (72 kGy) and six CPE inserts were also tested under conditions that could produce severe delamination for 8 Mc. Ten other knees (five 72 kGy HXPE and five CPE) were subjected to posterior edge loading fatigue testing for 5 Mc. The HXPE inserts had an average wear rate reduction of about 80% relative to their CPE counterparts during all activities. All of the CPE inserts delaminated and fractured during high cycle deep squat (152 degrees flexion) motions, while all the HXPE remained intact. None of the HXPE inserts delaminated after 8 Mc, while all of the CPE inserts developed delamination damage within 1.5-5.8 Mc of delamination testing. All CPE inserts developed subsurface cracks and delamination within 2.8 Mc during posterior edge loading fatigue studies, while none of the HXPE inserts showed cracking or delamination after 5 Mc. These results show that aged HXPE has higher wear and fatigue resistance than aged CPE, and offers potential long-term advantages for young active patients with sustained activities of daily living.


Assuntos
Resinas Acrílicas , Atividades Cotidianas , Análise de Falha de Equipamento , Prótese do Joelho , Polietilenos , Ligamento Cruzado Anterior , Artroplastia do Joelho , Reagentes de Ligações Cruzadas , Raios gama , Humanos , Teste de Materiais , Osteoartrite do Joelho/cirurgia , Oxirredução , Ligamento Cruzado Posterior , Esterilização , Tíbia/cirurgia , Caminhada , Suporte de Carga
8.
J Biomed Mater Res B Appl Biomater ; 93(1): 164-74, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20091911

RESUMO

Tissue-engineered osteochondral grafts have been synthesized from a variety of materials, with some success at repairing chondral defects in animal models. We hypothesized that in tissue-engineered osteochondral grafts synthesized by bonding mesenchymal stem cell-loaded hydrogels to a porous material, the choice of the porous scaffold would affect graft healing to host bone, and the quality of cell restoration at the hyaline cartilage surface. Bone marrow-derived allogeneic mesenchymal stem cells were suspended in hydrogels that were attached to cylinders of porous tantalum metal, allograft bone, or a bioactive glass. The tissue-engineered osteochondral grafts, thus created were implanted into experimental defects in rabbit knees. Subchondral bone restoration, defect fill, bone ingrowth-implant integration, and articular tissue quality were compared between the three subchondral materials at 6 and 12 weeks. Bioactive glass and porous tantalum were superior to bone allograft in integrating to adjacent host bone, regenerating hyaline-like tissue at the graft surface, and expressing type II collagen in the articular cartilage.


Assuntos
Cartilagem Articular/cirurgia , Engenharia Tecidual/métodos , Animais , Materiais Biocompatíveis , Cartilagem Articular/citologia , Condrogênese , Vidro , Hidrogéis , Teste de Materiais , Transplante de Células-Tronco Mesenquimais , Células-Tronco Mesenquimais/citologia , Microscopia Eletrônica de Varredura , Modelos Animais , Osseointegração , Porosidade , Coelhos , Alicerces Teciduais , Transplante Homólogo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA