Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Surg Res ; 195(1): 246-56, 2015 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-25634828

RESUMO

BACKGROUND: According to some clinical studies, insufficient cement distribution (ID) in the fractured area and asymmetrical cement distribution around the fractured area were thought to be the reasons for unrelieved pain and recollapse after percutaneous vertebral augmentation (PVA) in the treatment of symptomatic osteoporotic vertebral compression fractures. METHODS: Finite element methods were used to investigate the biomechanical variance among three patterns of cement distribution (ID and sufficient cement distribution in the fractured area and asymmetrical cement distribution around the fractured area including upward [BU] and downward [BD] cement distribution). RESULTS: Compared with fractured vertebra before PVA, distribution of von Mises stress in the cancellous bone was transferred to be concentrated at the cancellous bone surrounding cement after PVA, whereas it was not changed in the cortical bone. Compared with sufficient cement distribution group, maximum von Mises stress in the cancellous bone and cortical bone and maximum displacement of augmented vertebra increased significantly in the ID group, whereas asymmetrical cement distribution around the fractured area in BU and BD groups mainly increased maximum von Mises stress in the cancellous bone significantly. Similar results could be seen in all loading conditions. CONCLUSIONS: ID in the fractured area may lead to unrelieved pain after PVA in the treatment of symptomatic osteoporotic vertebral compression fractures as maximum displacement of augmented vertebral body increased significantly. Both ID in the fractured area and asymmetrical cement distribution around the fractured area are more likely to induce recollapse of augmented vertebra because they increased maximum von Mises stress in the cancellous bone and cortical bone of augmented vertebra significantly.


Assuntos
Cimentos Ósseos , Fraturas por Compressão/terapia , Modelos Biológicos , Fraturas por Osteoporose/terapia , Fraturas da Coluna Vertebral/terapia , Fenômenos Biomecânicos , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional
2.
Zhongguo Gu Shang ; 35(8): 732-5, 2022 Aug 25.
Artigo em Zh | MEDLINE | ID: mdl-35979765

RESUMO

OBJECTIVE: To explore the risk factors of hidden blood loss in osteoporosis vertebral compression fractures during percutaneous vertebral augmentation. METHODS: From October 2018 to December 2019, 360 patients with osteoporosis vertebral compression fractures who received percutaneous vertebral augmentation were enrolled in this study. The factors analyzed included gender, age, surgical methods, disease course, height, weight, the operative segment, bone mineral density, amount of bone cement, operative time, percentage of height loss, percentage of vertebral height restoration, cement leakage, blood clotting function, preoperative and postoperative hemoglobin and hematocrit and other internal diseases. Total blood loss was calculated by Gross's formula, influential factors of the hidden blood loss were further analyzed by t-test, multivariate linear regression and one-way ANOVA analysis. RESULTS: Surgical methods, the operative segment, disease course, cement leakage, preoperative hemoglobin, cement leakage via the basivertebral and segmental vein were significantly correlated with hidden blood loss(P<0.05). CONCLUSION: Patients with percutaneous kyphoplasty, two-level and multi-level surgery, the course of the disease beyond 6 weeks, cement leakage via the basivertebral and segmental vein, and lower preoperative hemoglobin had more perioperative hidden blood loss.


Assuntos
Fraturas por Compressão , Cifoplastia , Osteoporose , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Vertebroplastia , Cimentos Ósseos/efeitos adversos , Fraturas por Compressão/etiologia , Humanos , Cifoplastia/efeitos adversos , Cifoplastia/métodos , Osteoporose/complicações , Fraturas por Osteoporose/cirurgia , Estudos Retrospectivos , Fatores de Risco , Fraturas da Coluna Vertebral/etiologia , Resultado do Tratamento , Vertebroplastia/efeitos adversos
3.
Pain Physician ; 21(1): E33-E42, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29357338

RESUMO

BACKGROUND: Insufficient cement distribution (ICD) in the fractured area has been advocated to be responsible for unsatisfied pain relief after percutaneous vertebroplasty (PVP) for osteoporotic vertebral compression fractures (OVCFs). However, little is known about risk factors for the occurrence of ICD. OBJECTIVE: The present study aimed to identify independent risk factors of the emergence of ICD. STUDY DESIGN: A retrospective cohort study. SETTING: Department of spinal surgery, an affiliated hospital of a medical university. METHODS: Patients who underwent PVP for single-level OVCF from January 2012 to September 2014 and met this study's inclusion criteria were retrospectively reviewed. Associations of ICD with co-variates (age, gender, bone mass density with a T-score, amount of injected cement, cement leakage, fracture level, fracture age, fracture severity grade, and location of the fractured area) and the influence of ICD on pain relief were analyzed. RESULTS: A total of 225 patients were included. ICD was found in 26 (11.6%) patients. Fractured area located in the superior portion of the index vertebra was significantly associated with occurrence of ICD. No further significant associations between the studied co-variates and emergence of ICD were seen in the adjusted analysis. In addition, patients with ICD had significantly higher immediate postoperative visual analog scale scores of back pain compared with those with sufficient cement distribution in the fractured area. LIMITATION: Location of the fractured area and cement distribution in the fractured area could not be evaluated quantitatively. CONCLUSIONS: The incidence of ICD is higher in patients with the fractured area located in the superior portion of the index vertebra and ICD might be responsible for unsatisfied pain relief after PVP for OVCFs. KEY WORDS: Percutaneous vertebroplasty, insufficient cement distribution, fractured area, risk factor, osteoporosis, vertebral compression fracture, spine, unsatisfied pain relief, cement augmentation.


Assuntos
Cimentos Ósseos/efeitos adversos , Fraturas por Compressão/cirurgia , Fraturas por Osteoporose/cirurgia , Complicações Pós-Operatórias/etiologia , Fraturas da Coluna Vertebral/cirurgia , Vertebroplastia/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA